• Title/Summary/Keyword: Liquid ambient

Search Result 286, Processing Time 0.03 seconds

Atmospheric Distribution of PCDD/F Concentrations in Gyeonggi-do, South Korea (경기도 내 대기 중 다이옥신 분포 특성에 관한 연구)

  • Heo, Jong-Won;Min, Yoon-Ki;Kim, Dong-Gi;Choi, Il-Woo;Kim, Jong-Soo;Song, Il-Seok;Lee, Gangwoong
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.31 no.6
    • /
    • pp.548-561
    • /
    • 2015
  • Atmospheric concentrations of polychlorinated dibezo-p-dioxins and furans (PCDD/Fs) were investigated at urban-residential (Group I: Suwon, Guri and Goyang), industrial (Group II: Ansan, Siheung and Bucheon), urban-rural mixed (Group III: Yangju, Pocheon and Dongducheon) and rural regions (Group IV: Yangpyeong) in Gyeonggi-do from February 2012 to November 2012 quarterly. The concentrations of PCDD/Fs ranged from 0.018 to $0.109pgTEQm^{-3}$ in Group I (mean value: $0.061pgTEQm^{-3}$), 0.059 to $0.367pgTEQm^{-3}$ in Group II (mean value: $0.179pgTEQm^{-3}$), 0.072 to $0.836pgTEQm^{-3}$ in Group III (mean value: $0.334pgTEQm^{-3}$) and 0.014 to $0.066pgTEQm^{-3}$ in Group IV (mean value: $0.034pgTEQm^{-3}$), respectively. In spite of the less PCDD/F emission sources than Group II (industrial regions), the level of PCDD/Fs in urban-rural mixed area showed the highest values with high fluctuation. It's likely that the Group III was affected by fugitive emissions such like biomass burning and unregulated open burning. The mean contribution of particle phase to total PCDD/F concentration was above 83% because most of PCDD/F congeners were partitioned into particle phase. We evaluated their gas-to-particles equilibriums with the regression between the particle-gas partition coefficient, $K_P(m^3{\mu}g^{-1})$ and corresponding subcooled liquid vapor pressure ($P_L$). The logarithm-$K_P$ of PCDD/Fs was poorly correlated with $P_L$ at low ambient temperature (below $10^{\circ}C$) and the slope (m) values for log-log plots of the $K_P$ vs. $P_L$ was steeper in the Group 2 and Group 3 than residential area. It implies that the slope values were likely influenced by both the direct emission source of PCDD/Fs and ambient temperature.

Phytochemical analysis of Panax species: a review

  • Yang, Yuangui;Ju, Zhengcai;Yang, Yingbo;Zhang, Yanhai;Yang, Li;Wang, Zhengtao
    • Journal of Ginseng Research
    • /
    • v.45 no.1
    • /
    • pp.1-21
    • /
    • 2021
  • Panax species have gained numerous attentions because of their various biological effects on cardiovascular, kidney, reproductive diseases known for a long time. Recently, advanced analytical methods including thin layer chromatography, high-performance thin layer chromatography, gas chromatography, high-performance liquid chromatography, ultra-high performance liquid chromatography with tandem ultraviolet, diode array detector, evaporative light scattering detector, and mass detector, two-dimensional high-performance liquid chromatography, high speed counter-current chromatography, high speed centrifugal partition chromatography, micellar electrokinetic chromatography, high-performance anion-exchange chromatography, ambient ionization mass spectrometry, molecularly imprinted polymer, enzyme immunoassay, 1H-NMR, and infrared spectroscopy have been used to identify and evaluate chemical constituents in Panax species. Moreover, Soxhlet extraction, heat reflux extraction, ultrasonic extraction, solid phase extraction, microwave-assisted extraction, pressurized liquid extraction, enzyme-assisted extraction, acceleration solvent extraction, matrix solid phase dispersion extraction, and pulsed electric field are discussed. In this review, a total of 219 articles published from 1980 to 2018 are investigated. Panax species including P. notoginseng, P. quinquefolius, sand P. ginseng in the raw and processed forms from different parts, geographical origins, and growing times are studied. Furthermore, the potential biomarkers are screened through the previous articles. It is expected that the review can provide a fundamental for further studies.

Fracture Behaviour of Lubricants in ABS Terpolymer (ABS 중에 첨가된 저분자 화합물의 파단 거동에 미치는 영향)

  • Don, Yoon-Seung;Shim, Mi-Ja;Kim, Sang-Wook
    • Applied Chemistry for Engineering
    • /
    • v.5 no.5
    • /
    • pp.878-888
    • /
    • 1994
  • In order to investigate the fracture behavior of ABS terpolymer under the tension and impact load, varing the content of rubber, molecular weight of SAN, content and kinds of lubricant, tension speed, the mechanical properties were measured and SEM pictures of fracture area were taken. Under the tension, the tensile strength increased as rubber content and lubricant content decreased, while molecular weight and tension speed increased. The deformation of area near fracture site did not occur as rubber content, tension speed and molecular weight decreased and liquid lubricant was used. And in the shape of fracture seemed phase seperation. Under the impact load, the notched izod impact strength increased as rubber content, molecular weight, ambient temperature and lubricant content increased. In the SEM picture, the strength was high white the fracture surface was small.

  • PDF

Spray Characteristics of the Oxidizer-rich Preburner Injector in High Pressure Environments (로켓 산화제 과잉 예연소기용 분사기의 고압 분무특성 연구)

  • Yang, Joon-Ho;Choi, Seong-Man
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.12 no.2
    • /
    • pp.48-56
    • /
    • 2008
  • In the rocket preburner, oxidizer-rich combustion with liquid oxygen and kerosene is very challenging work. The key factor of stable flame is good mixing and that is controlled by the injector performance. We have studied spray characteristics of the oxidizer-rich rocket preburner injector in high pressure environments. The injector is composed of fuel orifices, oxidizer orifices and cooling skirt with liquid oxygen. By using this apparatus, we have taken photographs and measured Sauter mean diameter with changing ambient pressure from 0 to 30 kgf/cm2[g]. Droplet diameter is measured by the image processing technique. From the test results, we could understand spray characteristics of the oxidizer-rich preburner injector and this result could be applied to the development of the oxidizer rich preburner system.

Numerical Investigation on the Urea Melting Characteristics with Coolant and Electric Heaters (냉각수 및 전기 가열 방식에 따른 요소수 해동 특성에 관한 수치해석 연구)

  • Lee, Seung Yeop;Kim, Man Young
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.40 no.1
    • /
    • pp.1-7
    • /
    • 2016
  • A Urea-SCR(Selective Catalytic Reactor) system, which converts nitrogen oxides into nitrogen and water in the presence of a reducing agent, creates a major exhaust gas aftertreatment system for NOx reduction among other compounds. With regard to vehicle applications, a urea solution was chosen based on its eutectic composition of a 32.5wt% urea-water solution. An important advantage of this eutectic composition is that its melting point of $-11.7^{\circ}C$ is sufficiently low to avoid solidification in cold environments. However, the storage tanks must be heated separately in case of low ambient temperature levels to ensure a sufficient amount of liquid is available during scheduled start ups. In this study, therefore, a numerical investigation of three-dimensional unsteady heating problems analyzed to understand the melting processes and heat transfer characteristics including liquid volume fraction, temperature distributions, and temperature profiles. The investigations were performed using Fluent 6.3 commercial software that modeled coolant and electric heater models based on a urea solution. It is shown that the melting performance with the electric heater is higher than a coolant heater and is more efficient.

Effect of injection pressure on the atomization characteristics of a liquid sheet-type swirl injector for Urea-SCR system (Urea-SCR시스템 액막형 선회분사기의 분사압력변화에 따른 무특성에 관한 연구)

  • Kim, Duckjin;Yang, Donguk;Lee, Jeekeun
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.37 no.5
    • /
    • pp.510-519
    • /
    • 2013
  • In this study, the spray characteristics of a pressure swirl atomizer classified into a liquid sheet-type swirl nozzle for Urea-SCR system were investigated experimentally with the variation of injection pressure. The length to diameter ratio ($l_o/d$) of the nozzle was 3.1, and the swirler was set inside the nozzle tip to give injecting fluid angular momentum. The injection duration of the nozzle was controlled by PWM (pulse width modulation) modes. The development processes of the spray were imaged by a 2-D PIV system, and the change of spray angle was measured. The atomization characteristics, including axial velocity and SMD, were measured using a 2-D PDA system with the injection pressures at room temperature and ambient pressure conditions. As the experimental results, the injection pressure had a significant impact on the spray structure showing a different shape around the spray leading edge, and the smaller SMD was observed with increasing injection pressures, which was similar to that of the previous work.

Experimental Study on the Two Phase Thermosyphone Loop with Parallel Connected Multiple Evaporators under Partial Load and Low Temperature Operating Condition (병렬 연결된 다중 증발기 구조 2상 유동 순환형 열사이폰의 부분부하 및 저온운전 특성에 관한 실험적 연구)

  • Kang In-Seak;Choi Dong-Kyu;Kim Taig-young
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.11
    • /
    • pp.1051-1059
    • /
    • 2004
  • Two phase thermosyphone loop for electronics cooling are designed and manufactured to test its performance under the partial load and low environment temperature conditions. The thermosyphone device has six evaporators connected parallel for the purpose of cooling six power amplifier units (PAU) independently. The heater modules for simulating PAUs are adhered with thermal pad to the evaporator plates to reduce the contact resistance. There are unbalanced distributions of liquid refrigerant in the differently heated evaporators due to the vapor pressure difference. To reduce the vapor pressure differences caused by partial heating, two evaporators are connected each other using the copper tube. The pressure regulation tube successfully reduces these unbalances and it is good candidates for a field distributed systems. Under the low environment temperature operating condition, such as $-30^{\circ}C$, there may be unexpected subcooling in condenser. It leads the very low saturation pressure, and under this condition there exists explosive boiling in evaporator. The abrupt pressure rise due to the explosive boiling inhibits the supplement of liquid refrigerant to the evaporator for continuous cooling. Finally the cooling cycle will be broken. For the normal circulation of refrigerant there may be an optimum cooling air flow rate in condenser to adjust the given heat load.

Study on the Heat Transfer Phenomenon around Underground Concrete Digesters for Bigas Production Systems (생물개스 발생시스템을 위한 지하매설콘크리트 다이제스터의 열전달에 관한 연구)

  • 김윤기;고재균
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.22 no.1
    • /
    • pp.53-66
    • /
    • 1980
  • The research work is concerned with the analytical and experimental studies on the heat transfer phenomenon around the underground concrete digester used for biogas production Systems. A mathematical and computational method was developed to estimate heat losses from underground cylindrical concrete digester used for biogas production systems. To test its feasibility and to evaluate thermal parameters of materials related, the method was applied to six physical model digesters. The cylindrical concrete digester was taken as a physical model, to which the model,atical model of heat balance can be applied. The mathematical model was transformed by means of finite element method and used to analyze temperature distribution with respect to several boundary conditions and design parameters. The design parameters of experimental digesters were selected as; three different sizes 40cm by 80cm, 80cm by 160cm and l00cm by 200cm in diameter and height; two different levels of insulation materials-plain concrete and vermiculite mixing in concrete; and two different types of installation-underground and half-exposed. In order to carry out a particular aim of this study, the liquid within the digester was substituted by water, and its temperature was controlled in five levels-35。 C, 30。 C, 25。 C, 20。C and 15。C; and the ambient air temperature and ground temperature were checked out of the system under natural winter climate conditions. The following results were drawn from the study. 1.The analytical method, by which the estimated values of temperature distribution around a cylindrical digester were obtained, was able to be generally accepted from the comparison of the estimated values with the measured. However, the difference between the estimated and measured temperature had a trend to be considerably increased when the ambient temperature was relatively low. This was mainly related variations of input parameters including the thermal conductivity of soil, applied to the numerical analysis. Consequently, the improvement of these input data for the simulated operation of the numerical analysis is expected as an approach to obtain better refined estimation. 2.The difference between estimated and measured heat losses was shown to have the similar trend to that of temperature distribution discussed above. 3.It was found that a map of isothermal lines drawn from the estimated temperature distribution was very useful for a general observation of the direction and rate of heat transfer within the boundary. From this analysis, it was interpreted that most of heat losses is passed through the triangular section bounded within 45 degrees toward the wall at the bottom edge of the digesten Therefore, any effective insulation should be considered within this region. 4.It was verified by experiment that heat loss per unit volume of liquid was reduced as the size of the digester became larger For instance, at the liquid temperature of 35˚ C, the heat loss per unit volume from the 0. 1m$^3$ digester was 1, 050 Kcal/hr m$^3$, while at for 1. 57m$^3$ digester was 150 Kcal/hr m$^3$. 5.In the light of insulation, the vermiculite concrete was consistently shown to be superior to the plain concrete. At the liquid temperature ranging from 15。 C to 350 C, the reduction of heat loss was ranged from 5% to 25% for the half-exposed digester, while from 10% to 28% for the fully underground digester. 6.In the comparison of heat loss between the half-exposed and underground digesters, the heat loss from the former was fr6m 1,6 to 2, 6 times as much as that from the latter. This leads to the evidence that the underground digester takes advantage of heat conservation during winter.

  • PDF

A Dry-patterned Cu(Mg) Alloy Film as a Gate Electrode in a Thin Film Transistor Liquid Crystal Displays (TFT- LCDs) (TFT-LCDs 게이트 전극에 적용한 Cu(Mg) 합금 박막의 건식식각)

  • Yang Heejung;Lee Jaegab
    • Korean Journal of Materials Research
    • /
    • v.14 no.1
    • /
    • pp.46-51
    • /
    • 2004
  • The annealing of a Cu(4.5at.% Mg)/$SiO_2$/Si structure in ambient $O_2$, at 10 mTorr, and $300-500^{\circ}C$, allows for the outdiffusion of the Mg to the Cu surface, forming a thin MgO (15 nm) layer on the surface. The surface MgO layer was patterned, and successfully served as a hard mask, for the subsequent dry etching of the underlying Mg-depleted Cu films using an $O_2$ plasma and hexafluoroacetylacetone [H(hfac)] chemistry. The resultant MgO/Cu structure, with a taper slope of about $30^{\circ}C$ shows the feasibility of the dry etching of Cu(Mg) alloy films using a surface MgO mask scheme. A dry-etched Cu(4.5at.% Mg) gate a-Si:H TFT has a field effect mobility of 0.86 $\textrm{cm}^2$/Vs, a subthreshold swing of 1.08 V/dec, and a threshold voltage of 5.7 V. A novel process for the dry etching of Cu(Mg) alloy films, which eliminates the use of a hard mask, such as Ti, and results in a reduction in the process steps is reported for the first time in this work.

Liquid-Phase Sintered SiC Ceramics with Oxynitride Additives

  • Rixecker, G.;Biswas, K.;Wiedmann, I.;Sldinger, F.
    • Proceedings of the Korea Association of Crystal Growth Conference
    • /
    • 2000.06a
    • /
    • pp.1-33
    • /
    • 2000
  • Silicon carbide ceramics with sintering additives from the system AlN-Y$_2$O$_3$ can be gas-pressure sintered to theoretical density. While commonly a combination of sesquioxides is used such as Al$_2$O$_3$-Y$_2$O$_3$, the oxynitrid additives offer the advantage that only a nitrogen atmosphere is require instead of a powder. By starting form a mixture of ${\beta}$-SiC and ${\alpha}$-SiC, and by performing dedicated heat treatments after densification, anisotropic grain growth is obtained which leads to a platelet microstructure showing enhance fracture toughness. In the present work, recent improvement of the mechanical behaviour of these materials at ambient and high temperatures is reported. By means of a surface oxidation treatment in air it is possible to obtain four-point bending strengths in excess of 1 GPa, and the strength retention at high temperatures is significantly improved.

  • PDF