• Title/Summary/Keyword: Liquid Transient

Search Result 394, Processing Time 0.024 seconds

Analysis of Startup Characteristics for Turbo Pump Unit-Gas Generator Closed Loop Test (터보펌프 조립체-가스발생기 연계 폐회로 시험에서의 시동특성 분석)

  • Moon, Yoon-Wan;Kim, Seung-Han;Seol, Woo-Seok
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2008.11a
    • /
    • pp.19-22
    • /
    • 2008
  • This study fulfilled analysis of startup characteristics of Turbo pump unit-Gas generator closed loop test from the viewpoint of simulation. The test results were investigated and the calculated results were compared to test results. The curve for RPM developing predicted by simulation agreed well with test result. The slope of transient combustion pressure of gas generator correspond with test result.

  • PDF

The Performance Characteristics of Anti-Surge Devices for High Head Cooling Water Systems in 1,000 MW Thermal Power plants (고수두 1,000 MW 석탄화력발전소 냉각수계통 수격방지장치의 성능특성)

  • Kim, Keun-Pil;Yoo, Hoseon
    • Plant Journal
    • /
    • v.15 no.4
    • /
    • pp.36-42
    • /
    • 2019
  • In recent, according to the tightening of environment regulation policy, the height of the site of the power plant is increased and the length of the cooling water pipe is increased. This has a serious impact on the stability of the plant. This study analyzes the transient phenomenon using LIQT 7.2, an unsteady state one-dimensional analysis software, to secure the stability of 1,000 MW high-capacity coal-fired power plant cooling water system with high head. To prevent water hammer, The effects on performance characteristics were predicted by individual and combination application. The surge pressure of the cooling water which occurs when the pump was stopped without installing the anti-surge devices was the largest at the pump outlet side. The most effective and simple way to reduce surge pressure in these cooling water systems is to combine a vacuum breaker with a hydraulic non-return valve, which is an essential device for pump protection.

Transient Performance Analysis of the Reactor Pool in KALIMER-600 with an Inertia Moment of a Pump Flywheel (펌프 회전차의 관성모멘트 제공에 의한 KALIMER-600 원자로 풀 과도 성능 분석)

  • Han, Ji-Woong;Eoh, Jae-Hyuk;Lee, Tea-Ho;Kim, Seong-O
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.33 no.6
    • /
    • pp.418-426
    • /
    • 2009
  • The effect of an inertia moment of a pump flywheel on the thermal-hydraulic behaviors of the KALIMER-600(Korea Advanced LIquid MEtal Reactor) reactor pool during an early-phase of a loss of normal heat sink accident was investigated. The thermal-hydraulic analyses for a steady and a transient state were made by using the COMMIX-1AR/P code. In the present analysis a quarter of the reactor geometry was modeled in a cylindrical coordinate system, which includes a quarter of a reactor core and a UIS, a half of a DHX and a pump and a full IHX. In order to evaluate the effects of an inertia moment of the pump flywheel, a coastdown flow whose flow halving time amounts to 3.69 seconds was supplied to a natural circulation flow in the reactor vessel. Thermal-hydraulic behaviors in the reactor vessel were compared to those without the flywheel equipment. The numerical results showed a good agreement with the design values in a steady state. It was found that the inertia moment contributes to an increase in the circulation flow rate during the first 40 seconds, however to a decrease of it there after. It was also found that the flow stagnant region induced by a core exit overcooling decelerated the flow rate. The appearance of the first-peak temperature was delayed by the flow coastdown during the initial stages after a reactor trip.

Measurement of thermal conductivity of fluid by unsteady hot wire method (非定常 熱線法 에 의한 流體 의 熱傳達率 測定)

  • 고상근;양상식;노승탁
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.8 no.2
    • /
    • pp.154-161
    • /
    • 1984
  • A modified technique of the transient hot wire method to measure the thermal conductivity of fluid has been described in this paper. The thermal conductivity of fluid can be obtained by acquiring wire temperature as a function of time. Multiplication of the inverse slope of the temperature versus logarithm of time by an instrumental constant gives the thermal conductivity. The constant voltage was applied to Wheatstone bridge circuit. The wire temperature can be measured as a function of time precisely with the aid of the data acquisition system composed of a microprocessor and an analog-digital converter. The thermal conductivity of the electrically conducting fluid has been measured with the insulated hot wire coated by electrically non-conducting material. The effect of the coated insulation layer on the thermal conductivity has been examined, in which it is confirmed that the thermal conductivity of electrically conducting liquid can be determined by the transient coated hot wire method. Thermal conductivities of methanol, carbontetrachrolide, Freon-22 and glycerin have been measured at room temperature in the pressure from 0.1MPa to 35.1MPa. The experiment has been performed to compare the data from the bare and the coated wires, and the results are satisfactory.

Development of NO2/NOx Ratio Estimation Model for Urea-SCR System Application on Non-road Diesel Engine (비도로용 디젤엔진의 Urea SCR system 적용을 위한 NO2/NOx ratio 예측모델 개발에 관한 연구)

  • Kang, Seokho;Kim, Hoonmyung;Kang, Jeongho;Park, Eunyong;Kwon, Ohyun;Kim, Daeyeol
    • Journal of ILASS-Korea
    • /
    • v.25 no.4
    • /
    • pp.178-187
    • /
    • 2020
  • The current emission regulations, US Tier-4 and EU Stage-V, are only able to satisfy the regulations when all currently mass-produced emission reduction technologies such as EGR, DOC, DPF, and SCR are applied. Therefore, in this study, for the application of the Urea-SCR system to non-road diesel engines, the database was established by measuring the NO, NO2 concentration and calculating the NO2/NOx ratio based on the catalyst temperature and exhaust mass flow rate. Also, based on the measured NO2/NOx ratio data, a mathematical model was proposed to predict the NO2/NOx ratio at SCR catalyst, and the suitability of the model was verified through steady-state and transient mode. As a result of comparing the NO2/NOx ratio measured at the DOC outlet under the steady-state condition to two model values separately, the R2 was 0.9811 for the 3D map model and 0.9303 for the mathematical model. And in the case of the NO2/NOx ratio measured at the DPF outlet, the R2 was 0.9797 for the 3D map model and 0.935 for the mathematical model. It was confirmed that the R2 with the model value of the 3D Map of the mathematical model in the transient mode is 0.957, which shows high reliability.

A Study on Heat Transfer According to Inclined Angle and Surface Performance Using Turbulent Impingement Jet with a Liquid Crystal Transient Method (형상 및 경사 각도에 따른 난류 충돌 제트에 의한 과도 액정 기법을 이용한 열전달 특성에 대한 연구)

  • Lim, Kyoung-Bin;Lee, Chang-Hee;Lee, Sang-Hoon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.30 no.12 s.255
    • /
    • pp.1164-1172
    • /
    • 2006
  • Measurements of the local heat transfer coefficients on hemispherical convex and concave surfaces with a turbulent impinging jet were made. The Reynolds number used was 11000, 23000, 50000 and the nozzle- to- surface distance was L/d=2, 4, 6, 8, and 10 and the jet angle was a = $0^{\circ}$, $15^{\circ}$, $30^{\circ}$ and $40^{\circ}$. In case of concave surface, the Nusselt number at the stagnation point decreases as the jet angle increases and has the maximum value for L/d=6. The X-axis Nusselt number distributions exhibit secondary maxima at $0^{\circ}$ $\leq$ a $\leq$ $15^{\circ}$, L/d $\leq$ 4 for X/d<0(upstream) and at $0^{\circ}$ $\leq$ a $\leq$ $40^{\circ}$, L/d $\leq$ 4 and at $30^{\circ}$ $\leq$ a $\leq$ $40^{\circ}$, 4 < L/d $\leq$ 6 for X/d<0(downstream). The secondary maximum occurs at long distance from the stagnation point as the jet angle increases or the nozzle-to-surface distance decreases. In case of convex, correlations of the stagnation point Nusselt number according to Reynolds number, jet-to-surface distance ratio and dimensionless surface angle are presented. In the stagnation point, in term of Ren, n ranges from 0.43 in case of 2 $\leq$ L/d $\leq$ 6 to 0.45 in case of 6 < L/d $\leq$ 10, there agrees roughly appears to be laminar boundary layer result. The maximum Nusselt number, in this experiment, occurred in the direction of upstream. The displacement of the maximum Nusselt number from the stagnation point increases with increasing surface angle or decreasing nozzle-to-surface distance. On this condition about surface curvature D/d=10, the maximum displacement is about 0.7 times of the jet nozzle diameter. The ratio of the maximum Nusselt number to the stagnation Nusselt number increases as the jet angle increases.

Highly power-efficient and reliable light-emitting diode backlight driver IC for the uniform current driving of medium-sized liquid crystal displays

  • Hong, Seok-In;Nam, Ki-Soo;Jung, Young-Ho;Ahn, Hyun-A;In, Hai-Jung;Kwon, Oh-Kyong
    • Journal of Information Display
    • /
    • v.13 no.2
    • /
    • pp.73-82
    • /
    • 2012
  • In this paper, a light-emitting diode (LED) backlight driver integrated circuit (IC) for medium-sized liquid crystal displays (LCDs) is proposed. In the proposed IC, a linear current regulator with matched internal resistors and an adaptive phase-shifted pulse-width modulation (PWM) dimming controller are also proposed to improve LED current uniformity and reliability. The double feedback loop control boost converter is used to achieve high power efficiency, fast transient characteristic, and high dimming frequency and resolution. The proposed IC was fabricated using the 0.35 ${\mu}m$ bipolar-CMOS-DMOS (BCD) process. The LED current uniformity and LED fault immunity of the proposed IC were verified through experiments. The measured power efficiency was 90%; the measured LED current uniformity, 97%; and the measured rising and falling times of the LED current, 86 and 7 ns, respectively. Due to the fast rising and falling characteristics, the proposed IC operates up to 39 kHz PWM dimming frequency, with an 8-bit dimming resolution. It was verified that the phase difference between the PWM dimming signals is changed adaptively when LED fault occurs. The experiment results showed that the proposed IC meets the requirements for the LED backlight driver IC for medium-sized LCDs.

Numerical Analysis on Depressurization of High Pressure Carbon Dioxide Pipeline (고압 이산화탄소 파이프라인의 감압거동 특성에 관한 수치해석적 연구)

  • Huh, Cheol;Cho, Meang Ik;Kang, Seong Gil
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.19 no.1
    • /
    • pp.52-61
    • /
    • 2016
  • To inject huge amount of $CO_2$ for CCS application, high pressure pipeline transport is accompanied. Rapid depressurization of $CO_2$ pipeline is required in case of transient processes such as accident and maintenance. In this study, numerical analysis on the depressurization of high pressure $CO_2$ pipeline was carried out. The prediction capability of the numerical model was evaluated by comparing the benchmark experiments. The numerical models well predicted the liquid-vapor two-phase depressurization. On the other hands, there were some limitations in predicting the temperature behavior during the supercritical, liquid phase and gaseous phase expansions.

A Comparison Study of CFD Analysis and Flow Visualization on Behavior of Liquid Water in Cathode Channels of PEM Fuel Cells (PEM 연료전지 공기극 유로에서 물의 거동에 대한 CFD 해석과 가시화 실험의 비교 연구)

  • Kim, Hyun-Il;Nam, Jin-Hyun;Shin, Dong-Hoon;Chung, Tae-Yong;Kim, Young-Gyu;Seo, Won-Seok;Lee, Jung-Woon
    • Proceedings of the Korea Society for Energy Engineering kosee Conference
    • /
    • 2008.04a
    • /
    • pp.101-108
    • /
    • 2008
  • Polymer electrolyte membrane (PEM) fuel cells are promising power generation devices which are ideal for residential and automobile applications, thanks to their fast transient characteristics. However, liquid water produced in PEM fuel cells should be properly managed to enhance the performances and durabilities of the cells. In this study, a visualization experiment was conducted to investigate the flow behavior of water droplets in cathode channels. The visualization experiment was done with four different model flow channels which were made by varying the material (Acrylic and Teflon) and the channel width (1 mm and 2 mm). Acrylic is hydrophilic (contact angle is about $80^{\circ}$) while Teflon is hydrophobic (contact angle is about $120^{\circ}$). A computational fluid dynamics (CFD) analysis was also performed to compare the observed and the simulated two-phase water/air flow characteristics in cathode channels. The computational models were made to be consistent with the geometries and surface properties of the model flow channels. Both the experimental and numerical results showed that the Teflon cathode channel with 1 mm width has the best water management performance among four model flow channels considered. A close correlation was found between the experimental visualization results and the numerical CFD simulation results.

  • PDF

Closing Characteristics of a Main Oxidizer Shut-off Valve (연소기 산화제 개폐밸브 닫힘 작동특성)

  • Hong, Moongeun
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.48 no.9
    • /
    • pp.717-724
    • /
    • 2020
  • We study the closing characteristics of a self-sustainable poppet valve which serves as a main oxidizer shut-off valve for liquid rocket engines. Numerical analysis for predicting closing transient responses are presented and the calculated results have been verified by a comparison with experimental data. The effective area of a pilot gas discharge system and the pressure distribution of passage flow around the valve moving part are shown to be main parameters in determining the closing characteristics for dry and cryogenic conditions, respectively. Moreover, it is presented that the passage flow pressure at the valve closing moment as well as the valve closing velocity can be effectively adjusted by the appropriate employment of the pilot gas.