• 제목/요약/키워드: Liquid Silicone

검색결과 88건 처리시간 0.037초

Preparation and Characteristics of High Voltage Liquid Silicone Rubber by Modified Cross-linking Agent

  • Jung, Se-Young;Kim, Byung-Kyu
    • Transactions on Electrical and Electronic Materials
    • /
    • 제10권1호
    • /
    • pp.9-15
    • /
    • 2009
  • There is a growing demand for a high voltage silicone rubber composite with high mechanical property and high electrical property. The effect of modified cross-linking agent on the mechanical, electrical properties, and short-circuit test performance of silicone rubber insulators have been investigated. To use base polymer, the various silicone polymers were prepared by the equilibrium polymerization. Aluminum trihydrate surface was treated by vinyl silane. Liquid silicone rubber nanocomposite was prepared from the compounding of VPMPS, HPDMS, catalyst, and alumina trihydrate modified with 1,3,5-trivinyl-l,3,5-trimethylcyclotrisiloxane. The mechanical property and electrical property for insulation materials were measured, indicating the high tensile strength and the good short-circuit property.

Blends of Silicone Rubber and Liquid Crystalline Polymer

  • Shivakumar E.;Das C. K.;Pandey K. N.;Alam S.;N.Mathur G.
    • Macromolecular Research
    • /
    • 제13권2호
    • /
    • pp.81-87
    • /
    • 2005
  • Blends of silicone rubber (VMQ) and liquid crystalline polymer (LCP) were prepared by the melt mixing technique. Mechanical, XRD, thermal and dynamic mechanical investigations are reported for the pure silicone rubber and blends. The mechanical properties, viz. the tensile strength, tear strength and elongation at break, of the silicone rubber decreased with the addition of LCP. The SEM study on the tensile fractured surface of the blends revealed that they had a two phase structure, and that the failure was mainly due to fiber pull out, which suggests that the VMQ and LCP are incompatible in all of the proportions examined in this study. However, the FTIR study shows that there was a partial interaction between the VMQ and LCP, but which may not be sufficient to grip the fibrils under the applied load. In the XRD analysis, it was observed that the crystalline structure of the silicone rubber deteriorated in the presence of LCP. The DMA study suggested that the storage modulus of the silicone rubber was improved with the addition of LCP, due to the high modulus of the LCP phase. The thermal stability of the silicone rubber was greatly reduced by the addition of LCP, due to the latter having a thermal stability lower than that of silicone rubber.

플라스틱 직물 코팅재료에 관한 연구 (Study on Plastic Fiber Coating Materials)

  • 김동학;김태완
    • 한국산학기술학회논문지
    • /
    • 제4권1호
    • /
    • pp.42-46
    • /
    • 2003
  • 섬유 코팅제로 널리 쓰이고 있는 액상 PVC는 여러 가지 특성 중 무광택 효과가 뛰어나지만 코팅된 섬유 표면의 유연성이 감소된다. 이런 결함을 대체할 수 코팅 물질로 Elastomer계열의 액상 실리콘 고무를 사용했다. 기존 액상 PVC공정과 동일하게 진행했으며, 로울러의 압축력과 공정상의 예비경화를 이용했다. 실험 결과 액상 PVC로 코팅된 직물의 경도는 70E, 인장강도는 10.3 MPa, 신율은 200%로 측정되었다. 액상 실리콘 고무로 코팅된 직물의 경도는 40도, 인장강도는 5.1 MPa, 신율은 460%,였다. 따라서 액상 실리콘 고무 코팅은 3차 가공 없이 액상 PVC 코팅보다 플라스틱 직물 표면의 무광택성과 유연성을 증가시켰다.

  • PDF

The Effect of Glass Fiber and Coupling Agents in the Blends of Silicone Rubber and Liquid Crystalline Polymers

  • Das T.;Banthia A.K.;Adhikari B.;Jeong Hye-Won;Ha Chang-Sik;Alam S.
    • Macromolecular Research
    • /
    • 제14권3호
    • /
    • pp.261-266
    • /
    • 2006
  • Blends of silicone rubber (VMQ) and liquid crystalline polymer (LCP) were prepared using a melt blending technique in the presence and absence of glass fiber and coupling agents. The effect of glass fiber and coupling agents on the thermal, dynamic mechanical, morphological pro-perties and cure characteristics of VMQ/LCP blends were studied. The vinyl silane coupling agent showed a significant effect on the above mentioned properties of VMQ/LCP blends by reacting at the interface between VMQ and LCP. The viscosity of the VMQ/LCP blends decreased with the addition of a coupling agent. A substantial improvement in storage modulus of VMQ/LCP blends was observed in the presence of glass fiber and coupling agents. However, as a coupling agent vinyl silane proved to be better than amine for the VMQ/LCP-glass-containing blends. The thermal stability of the pure silicone rubber was higher than those of the blends. This high thermal stability of silicone rubber was attributed to the Si-O-Si bonds. However, the thermal stability of the blends decreased further in the presence of a coupling agent, possibly due to a decrease in blend crystallinity.

Encapsulation용 silicone을 사용한 모듈제조 공정에 대한 연구 (The study on PV module development using the silicone encapsulation)

  • 정인성;이우진;이범수;양오봉;정은석;김종일
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2011년도 춘계학술대회 초록집
    • /
    • pp.130.1-130.1
    • /
    • 2011
  • Nowadays, the number of PV module corporation is increasing due to demand growth of silicon solar module. However almost study of module is research about increasing of efficiency for it. This study is evaluation and development for process of module using the silicone encapsulation material instead of existing EVA sheet. We are changed adding material ratio on silicone and thickness of silicone. So we get better efficiency than EVA sheet through the evaluation for silicone liquid and modulation. Also, we are test after establishing manufacture system being able to quicker than existing modules line. The result of EVA sheet is average 207.47W and silicone material is 211.32W so we think that silicone is better than EVA sheet.

  • PDF

Effect of Lecithin on Dermal Safety of Nanoemulsion Prepared from Hydrogenated Lecithin and Silicone Oil

  • Bae, Duck-Hwan;Shin, Jae-Sup;Shin, Gwi-Su;Jin, Fan-Long;Park, Soo-Jin
    • Bulletin of the Korean Chemical Society
    • /
    • 제30권4호
    • /
    • pp.821-824
    • /
    • 2009
  • In this study, a hydrogenated lecithin-containing nanoemulsion was prepared from hydrogenated lecithin and silicone oil. Tween-60 and liquid paraffin, widely known emulsifiers, were used as standard substances, and high shear was produced by utilizing a high shear homogenizer and microfluidizer. The properties of the nanoemulsion prepared with hydrogenated lecithin were evaluated by measuring interfacial tension, dynamic interfacial tension, droplet size, zeta-potential, friction force, skin surface hygrometery, and dermal safety. The interfacial tension of lecinol S10/silicone oil was lower than that of lecinol S10/liquid paraffin. The nanoemulsion prepared from hydrogenated lecithin shows lower zeta-potential, skin surface hygrometery, and friction force compared with a general emulsion. The silicone nanoemulsion prepared from hydrogenated lecithin showed a zero value in the patch test and thus exhibits high dermal safety.

Unique Fluid Ensemble including Silicone Oil for the Application of Optical Liquid Lens

  • Bae, Jae-Young;Park, Sung-Soo;Kim, Jae-Hong;Park, Chin-Ho;Choi, Young-Chul;Jung, Ha-Yong
    • Bulletin of the Korean Chemical Society
    • /
    • 제29권4호
    • /
    • pp.731-735
    • /
    • 2008
  • The fluid ensemble in the liquid lens, which is composed of electrolyte and silicone oil, is the key material system to vary the focal length processing of the electrochemical desorption. In order to characterize the capability of the liquid lens according to response time and optical range, we prepared a fluid ensemble comprising the electrolyte and oil. To elucidate the physical mechanism of the effective response time, we examined the viscosity dependency while satisfying the requirements for the density and refractive index of the electrolyte and oil, respectively. The characterization results indicated that the response time (up and down) is influenced by the viscosity of the electrolyte and oil. On this basis, we prepared a fluid ensemble capable of reversibly adjusting for the focal length of the liquid lens, as well as the response time. The ensemble is applicable to various systems such as micro-lens and optical sensors.

A Photochromic Dye Activation Method for Measuring the Thickness of Liquid Films

  • Kim, Jeong-Bae;Kim, Moo-Hwan
    • Bulletin of the Korean Chemical Society
    • /
    • 제26권6호
    • /
    • pp.966-970
    • /
    • 2005
  • To measure the thickness of liquid films from 10 to 60 ${\mu}m$, we used photochromic dye activation. And we used silicone oil with 10 centi-Stokes and commercial photochromic dyes. To make films with exact and known thicknesses, we used two glass wafers. A film formed between two wafers after placing a drop of liquid of known volume on one wafer and covering the other. The film thickness could be estimated from the diameter of wafer and the dropped liquid volume. To quantitatively evaluate the result, captured the images using digital camera then analyzed the images using the image tool. The gray scale intensity using the captured images of activated dye with these thicknesses showed the repeatability below ${\pm}$ 1.0% when measured with a silicone oil solution containing 0.1% SO and SO-ANTH dyes. And we showed that photochromic dye activation method could be used to measure our liquid film thickness ranges.