• Title/Summary/Keyword: Liquid Lens

Search Result 108, Processing Time 0.025 seconds

A Study on the Fabrication Method of Mold for 2 inch LCD-BLU by 50μm Microlens : Effect of Different Aspect Ratio (50μm급 마이크로렌즈 적용 2인치 휴대폰 LCD-BLU 금형 개발 : 광학패턴의 세장비 영향)

  • Kim, J.S.;Ko, Y.B.;Min, I.K.;Yu, J.W.;Heo, Y.M.;Yoon, K.H.;Hwang, C.J.
    • Transactions of Materials Processing
    • /
    • v.16 no.1 s.91
    • /
    • pp.48-53
    • /
    • 2007
  • LCD-BLU(Liquid Crystal Display - Back Light Unit) consists of several optical sheets: LGP(Light Guiding Plate), light source and mold frame. The LGP of LCD-BLU is usually manufactured by etching process and forming numerous dots with $50{\mu}m$ in diameter on the surface. But the surface roughness of LGP with etched dots is very high, so there is much loss of light. In order to overcome the limit of current etched dot patterned LGP, optical pattern design with microlens of $50{\mu}m$ diameter was applied in the present study. The microlens pattern fabricated by modified LiGA with thermal reflow process was applied to the optical design of LGP and optical simulation was carried out to know tendency of microlens patterned LGP simultaneously. The attention was paid to the effects of different aspect ratio(i.e. $0.2\sim0.5$) of optical pattern conditions to the brightness distribution of BLU with microlens patterned LGP. Finally, high aspect ratio microlens patterned LGP showed superior results to the one made by low aspect ratio in average luminance.

Development of the Real-time Concentration Measurement Method for Evaporating Binary Mixture Droplet using Surface Plasmon Resonance Imaging (표면플라즈몬공명 가시화 장치를 이용한 증발하는 이종혼합물 액적의 실시간 농도 가시화 기법 개발)

  • Jeong, Chan Ho;Lee, Hyung Ju;Choi, Chang Kyoung;Lee, Hyoungsoon;Lee, Seong Hyuk
    • Journal of ILASS-Korea
    • /
    • v.26 no.4
    • /
    • pp.212-218
    • /
    • 2021
  • The present study aims to develop the Surface Plasmon Resonance (SPR) imaging system facilitating the real-time measurement of the concentration of evaporating binary mixture droplet (BMD). We introduce the theoretical background of the SPR imaging technique and its methodology for concentration measurement. The SPR imaging system established in the present study consists of a LED light source, a polarizer, a lens, and a band pass filter for the collimated light of a 589 nm wavelength, and a CCD camera. Based on the Fresnel multiple-layer reflection theory, SPR imaging can capture the change of refractive index of evaporating BMD. For example, the present study exhibits the visualization process of ethylene glycol (EG)-water (W) BMD and measures real-time concentration change. Since the water component is more volatile than the ethylene glycol component, the refractive index of EG-W BMD varies with its mixture composition during BMD evaporation. We successfully measured the ethylene glycol concentration within the evaporating BMD by using SPR imaging.

Study on the Pattern of Internal Flow inside a water droplet placed on Vibrating Hydrophobic Surface (진동하는 소수성 표면 위에 놓인 액적의 모드별 내부유동 패턴변화에 관한 연구)

  • Kim, Hun;Shin, Young Sub;Lim, Hee Chang
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.38 no.4
    • /
    • pp.329-335
    • /
    • 2014
  • This study aimed to understand the internal flow characteristics of a liquid droplet subject to periodic forced vibration. In order to predict the resonance frequency of a droplet, a high-speed camera and macro lens were used to capture internal flow characteristics of a droplet placed on a vibrating hydrophobic surface. Results showed that the droplet assumed a variety of shapes depending on the resonance mode of free droplet, particularly in modes 2, 4, 6, and 8. In addition, the induced internal vortex flow inside the droplet was also observed in each mode. Typically, the induced flow moved upwards along the axis of symmetry and downwards along the surface of the droplet, that is, from the apex to the contact line in modes 2 and 4, after which it broke into a smaller vortex. On the other hand, the large-scale vortex always remained steady in modes 6 and 8. The speed of the flow in mode 4 was always greater than that in mode 2, but those in modes 6 and 8 were similar.

Quantitative Determination of the Marker Components in Pyungwi-San Using LC-ESI-MS/MS (LC-ESI-MS/MS를 이용한 평위산 주요 성분의 함량 분석)

  • Seo, Chang-Seob;Shin, Hyeun-Kyoo
    • Korean Journal of Pharmacognosy
    • /
    • v.49 no.3
    • /
    • pp.270-277
    • /
    • 2018
  • Pyungwi-san has been used to treat the digestive system diseases, physconia, nausea, anorexia, and dyspepsia in Korea. In this study, an ultra-performance liquid chromatography-electrospray ionization-mass spectrometry (UPLC-ESI-MS/MS) method was optimized for simultaneous determination of the 14 marker components, spinosin, liquiritirn apioside, liquiritin, narirutin, 6'''-feruloylspinosin, hesperidin, liquiritigenin, glycyrrhizin, 6-gingerol, atractylenolide III, honokiol, atractylenolide II, magnolol, and atractylenolide I in Pyungwi-san extract. All analytes were separated on a Waters Acquity UPLC BEH $C_{18}$ analytical column ($2.1{\times}100mm$, $1.7{\mu}m$) with maintained at $45^{\circ}C$. The mobile phase consisted of 0.1% (v/v) aqueous formic acid and acetonitrile. The MS conditions were as follows: capillary voltage 3.3 kV, extractor voltage 3.0 V, RF lens voltage 0.3 V, source temperature $120^{\circ}C$, desolvation temperature $300^{\circ}C$, desolvation gas 600 L/h, cone gas 50 L/h and collision gas 0.14 mL/min. The coefficient of determination of 14 analytes was 0.9989-1.0000. The limits of detection and quantification values of the all analytes were 0.04-2.56 and 0.13-7.69 ng/mL, respectively. As a result of the analysis using the established LC-ESI-MS/MS method, the 5 components, spinosin, 6'''-feruloylspinosin, atractylenolide III, II, and I derived from Zizyphi Fructus and Atractylodis Rhizoma, were not detected in this extract. On the other hand, the 9 components except for the 5 components were 4.15-498.87 mg/kg in lyophilized Pyungwi-san extract. Among these components, glycyrrhizin, marker compound of Glycyrrhizae Radix et Rhizoma, was detected the most amount as a 498.87 mg/kg.

New BLU Sheet with Linear Arrays of Deformed Bar Prism for Direct Back Light Unit (직하형 Back Light Unit에 사용하는 변형 막대프리즘의 1차원 배열로 구성한 새로운 BLU 필름)

  • Jang, Sun-Young;Jo, Jae-Heung;Baek, Seung-Sun
    • Korean Journal of Optics and Photonics
    • /
    • v.18 no.6
    • /
    • pp.401-409
    • /
    • 2007
  • A new sheet of back light unit(BLU) to reduce the number of sheets and enhance the optical performances of direct back light unit(BLU) in a liquid crystal display is proposed and designed. In order to improve the straightness and spatial uniformity of brightness of the BLU, we design the new sheet with linear arrays of complicated bar prism by using the fusion of cylindrical lens and bar prism. Then, we investigate and analyze various optical performances of a BLU including the new sheet through an illumination optical system design program. From these results, we determine the optimum geometrical structure of the sheet. Under the optimum condition, the luminance efficiency and spatial uniformity of luminance of the BLU are 53.5% and 83.5% respectively. And the vertical and horizontal widths of the angular luminance distribution are $90^{\circ}$ and $112.5^{\circ}$ respectively. Finally we have fabricated a new BLU sheet according to this design shape by using an ordinary resins.

Realization of the multi-phase level CGH according to the multi-channel encoding method using a PAL-SLM (PAL-SLM을 이용한 다채널 부호화 방법에 따른 다위상형 CGH의 광학적 구현)

  • Jung, Jong-Rae;Baek, Woon-Sik;Kim, Jung-Hoi;Kim, Nam
    • Korean Journal of Optics and Photonics
    • /
    • v.15 no.4
    • /
    • pp.299-308
    • /
    • 2004
  • We proposed more efficient encoding methods that can design a multi-channel multi-level phase only computer-generated hologram(CGH) that can reconstruct many objects simultaneously without a conjugate image. We used a fabrication technique for the pixel oriented CGH for designing the pattern of the proposed multi-channel CGH. We investigated the difference of the optical efficiency(η), mean square error(MSE) and signal-to-noise ratio(SNR) of multi-channel CGHs that were designed by three kinds of encoding methods according to the number of quantization phase levels, and we estimated the performance of the pattern of the proposed multi-channel CGH. Generally, as the number of input objects' reference patterns stored in the CGH is increased, the reconstruction quality of the CGH is degraded. But we observed through computer simulation that the diffraction efficiency of the 1-ch CGH is 70%, and those of the 2-ch, 4-ch, 8-ch CGHs are 62%, 62% and 63%. Therefore we found that the diffraction efficiencies of the multi-channel CGHs using the newly proposed encoding method are similar to that of 1-ch CGH. We implemented the CGH optically using a liquid crystal spatial light phase modulator that consisted of a PAL-SLM efficiently coupled with a XGA type LCD by an optical lens and an LD for illuminating the LCD. We discussed the output images that are reconstructed from the PAL-SLM.

Optimization of Optical Structure of Lightguide Panel for Uniformity Improvement of Edge-lit Backlight (엣지형 LED 백라이트의 균일도 향상을 위한 도광판의 광구조 최적화)

  • Lee, Jung-Ho;Nahm, Kie-Bong;Ko, Jae-Hyeon;Kim, Joong-Hyun
    • Korean Journal of Optics and Photonics
    • /
    • v.21 no.2
    • /
    • pp.61-68
    • /
    • 2010
  • Optical simulation methods were applied to the edge-lit LED backlight for LCD TV applications in order to optimize the optical structure of the light guide plate(LGP), and thus to improve the uniformity properties by removing the bright spots caused by LED's. The edge-lit LED backlight consisted of three white LED's with a lamp cover, a light guide plate, and a reflection film. When there was no pattern on the entrance side surface of the LGP, the illuminance uniformity was sensitively dependent on the distance d between the LED and the entrance surface. The illuminance uniformity increased with d but its increasing rate slowed down when d was beyond ~ 1.5 mm. When micro-patterns such as a lenticular lens array (LLA) or a serration pattern were formed on the entrance surface, the illuminance uniformity was improved substantially even for the case of very small d. At the same simulation condition, the lightguide with serration pattern showed a better uniformity than that with LLA pattern. Additional improvement could be achieved by changing the refractive index of the micro-patterns. These results suggest that using micro-patterns is a very effective way to reduce the bright spots due to their refracting function for the concentrated incident rays onto the LGP.

FHD Flexible Endoscopy Design Using Wedge Prism (Wedge Prism을 이용한 FHD급 연성 내시경 광학계 설계)

  • Park, Sung-Woo;Jung, Mee-Suk
    • Korean Journal of Optics and Photonics
    • /
    • v.33 no.6
    • /
    • pp.295-302
    • /
    • 2022
  • In this paper, a wedge prism application method was studied to design a full-high-definition (FHD)-class high-resolution flexible endoscope. In the case of the conventional flexible endoscope optical system, the F number is made large or a liquid lens is applied to obtain the same imaging performance in a wide depth of field. However, there is a problem in that the diameter of the optical system increases because an additional light guide and equipment are required. To solve this problem, two wedge prisms were applied to the flexible endoscope optical system to adjust the image distance for each object distance. First, two wedge prisms were symmetrically placed on the designed endoscopic optical system. An image distance satisfying the target imaging performance according to each objective distance was derived. Next, the wedge prism decenter value for controlling the image distance was derived. By combining these two data, a wedge prism decenter value that satisfied the target imaging performance at each object distance was applied in multi configurations. As a result of the optimal design applied with the wedge prism, a target imaging performance of more than 20% of the modulation transfer function for a resolution of 178 cycles/mm was satisfied in the entire depth of field of 100 mm-7 mm.