• Title/Summary/Keyword: Liquid Height

Search Result 406, Processing Time 0.031 seconds

Experimental Study of Close-Contact Melting of Phase-Change Medium Partially Filled in a Horizontal Cylinder (수평원관내 부분적으로 채원진 상변화물질의 융해과정)

  • 서정세;노승탁
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.19 no.9
    • /
    • pp.2249-2260
    • /
    • 1995
  • An experiment of close contact melting of phase-change medium partially filled in an isothermally heated horizontal cylinder is performed which involves the volume expansion of liquid induced by the solid-liquid density difference. The solid-liquid interface motion and the free surface behavior of liquid were reported photographically. The experimental results show that the curvature of upper solid-liquid interface varied to flat as melting progresses. In addition to the varying interface shape, the melting rate increases with the lower initial height of solid and the free surface height of liquid increases linearly. The experimental results of molten mass fraction were expressed in a function of dimensionless time Fo.Ste$^{3}$4/ and agreed well with the analytical solutions.

Combined Microwave Radiometer and Micro Rain Radar for Analysis of Cloud Liquid Water

  • Yang, Ha-Young;Chang, Ki-Ho;Kang, Seong-Tae
    • Journal of Integrative Natural Science
    • /
    • v.6 no.1
    • /
    • pp.12-15
    • /
    • 2013
  • To combine the micro rain radar and microwave radiometer cloud liquid water, we estimate the cloud physical thickness from the difference between the MTSAT-1R cloud top height and cloud base height of visual observation of Daegwallyeong weather station, and the cloud liquid water path of micro rain radar is obtained by multiplying the liquid water content of micro rain radar and the estimated cloud physical thickness. The trend of microwave radiometer liquid water path agrees with that of the micro rain radar during small precipitation. We study these characteristics of micro rain radar and microwave radiometer for small precipitation to obtain the combined cloud water content of micro rain radar and microwave radiometer, constantly operated regardless to the rainfall.

Basic Study on the Design and Optimization of Sonoreactors for Sonochemical Water/Wastewater Treatment Processes (초음파 수처리 공정 개발을 위한 반응기 설계 기초 연구)

  • Kim, Seulgi;Son, Younggyu
    • Journal of Wetlands Research
    • /
    • v.16 no.2
    • /
    • pp.205-212
    • /
    • 2014
  • Ultrasound technology can be applied in various fields including environmental, energy, and material engineering processes. In this study the effect of liquid height/volume on calorimetric energy and sonochemical oxidation was investigated as one of the basic steps for the design of water/wastereater treatment sonoreactors. The liquid height was increased from 0 to $4{\lambda}$ by $1/4{\lambda}$ and it was found that both calorimetric energy and sonochemical oxidation were significantly increased at relatively high liquid height/volume where the power density was relatively low. The sonochemiluminescence (SCL) images for the visualization of the activity of cavitation also showed that larger and more stable active zone was formed with high SCL intensity at high liquid height/volume. Therefore, it was revealed that sonoreactors for water/wasterwater treatment could be significantly effective in terms of removal efficiency and energy consumption.

Effect of higher modes and multi-directional seismic excitations on power plant liquid storage pools

  • Eswaran, M.;Reddy, G.R.;Singh, R.K.
    • Earthquakes and Structures
    • /
    • v.8 no.3
    • /
    • pp.779-799
    • /
    • 2015
  • The slosh height and the possibility of water spill from rectangular Spent Fuel Storage Bays (SFSB) and Tray Loading Bays (TLB) of Nuclear power plant (NPP) are studied during 0.2 g, Safe Shutdown Earthquake (SSE) level of earthquake. The slosh height obtained through Computational Fluid dynamics (CFD) is compared the values given by TID-7024 (Housner 1963) and American concrete institute (ACI) seismic codes. An equivalent amplitude method is used to compute the slosh height through CFD. Numerically computed slosh height for first mode of vibration is found to be in agreement the codal values. The combined effect in longitudinal and lateral directions are studied separately, and found that the slosh height is increased by 24.3% and 38.9% along length and width directions respectively. There is no liquid spillage under SSE level of earthquake data in SFSB and TLB at convective level and at free surface acceleration data. Since seismic design codes do not have guidelines for combined excitations and effect of higher modes for irregular geometries, this CFD procedure can be opted for any geometries to study effect of higher modes and combined three directional excitations.

Empirical Correlations for Breakup Length of Liquid Jet in Uniform Cross Flow-A Review

  • No, Soo-Young
    • Journal of ILASS-Korea
    • /
    • v.18 no.1
    • /
    • pp.35-43
    • /
    • 2013
  • The empirical correlations for the prediction of breakup length of liquid jet in uniform cross flow are reviewed and classified in this study. The breakup length of liquid jets in cross flow was normally discussed in terms of the distances from the nozzle exit to the column breakup location in the x and y directions, called as column fracture distance and column fracture height, respectively. The empirical correlations for the prediction of column fracture distance can be classified as constant form, momentum flux ratio form, Weber number form and other parameter form, respectively. In addition, the empirical correlations for the prediction of column fracture height can be grouped as momentum flux ratio form, Weber number form and other parameter form, respectively. It can be summarized that the breakup length of liquid jet in a cross flow is a basically function of the liquid to air momentum flux ratio. However, Weber number, liquid-to-air viscosity ratio and density ratio, Reynolds number or Ohnesorge number were incorporated in the empirical correlations depending on the investigators. It is clear that there exist the remarkable discrepancies of predicted values by the existing correlations even though many correlations have the same functional form. The possible reasons for discrepancies can be summarized as the different experimental conditions including jet operating condition and nozzle geometry, measurement and image processing techniques introduced in the experiment, difficulties in defining the breakup location etc. The evaluation of the existing empirical correlations for the prediction of breakup length of liquid jet in a uniform cross flow is required.

A study on Removal of $NH_3$ Gas in a Towar using a Ralu-Pack 250YC as a Packing Material (Ralu-Pack 250YC를 충전한 충전탑에서 암모니아가스 제거에 관한 연구)

  • 김석택
    • Journal of Environmental Science International
    • /
    • v.9 no.5
    • /
    • pp.389-392
    • /
    • 2000
  • In this study a packed tower was selected for the treatment apparatus of $NH_3$ gas produced in industry. Formerly latticework packing has been used in preventive facility of treatment of $NH_3$ gas. However recently metallic Ralu-Pack 250YC. structured packing is usually being used in petrochemical production plant. This study is for the application the packing to the $NH_3$ gas treatment in wet scrubbing process. In Air/water system hydraulic pressure drop dependent of specific liquid load and gas capacity factor was continuous and parallel from graph. The tower height can be determuined by the number of transfer unit and the height of transfer unit influenced on liquid distribution.

  • PDF

Characteristic of Mass Transfer Volumetric Coefficient and Sauter Mean Diameter in a Liquid-Liquid Agitated Vessel (액-액 교반조내에서의 물질이동용량계수 및 액적경의 특성)

  • Lee, Young-Sei
    • Korean Chemical Engineering Research
    • /
    • v.50 no.5
    • /
    • pp.913-922
    • /
    • 2012
  • Grasp of characteristics within liquid-liquid agitated vessel are very important to environment and chemical industry. Mass transfer volumetric coefficient and the Sauter mean diameter of near the droplet were measured by varying the impeller position and liquid height using the alkaline hydrolysis reaction of esters. As a result, following their good correlation was obtained. $$d_{32}=0.270\(\frac{{\sigma}^{0.6}}{{\rho}^{0.2}P^{0.4}_{Vi}}\)k_La=0.49\(\frac{6{\phi}D_A}{d^2_{32}}\)\(\frac{P_Vd^4_{32}}{{\rho}v^3}\)^{0.193}Sc^{1/3}$$.

Investigation on the Liquid Water Droplet Instability in a Simulated Flow Channel of PEMFC (고분자전해질형 연료전지의 유로 채널 모사를 통한 단일 액적의 불안정성 관찰)

  • Kim, Bo-Kyung;Kim, Han-Sang;Min, Kyung-Doug
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.16 no.2
    • /
    • pp.93-98
    • /
    • 2008
  • To investigate the characteristics of water droplet on the gas diffusion layer from both top-view and side-view of the flow channel, a rig test apparatus was designed and fabricated with prism attached plate. This experimental device is used to simulate the growth of single liquid water droplet and its transport process with various air flow velocity and channel height. The contact angle hysteresis and height of water droplet are measured and analyzed. It is found that droplet tends towards to be instable by decreasing channel height, increasing flow velocity or making GDL more hydrophobic. Also, the simplified force balance model matches with experimental data only in a restricted range of operating conditions and shows discrepancy as the air flow velocity and channel height increases.

Numerical Study on Liquid Sloshing in the Three-dimensional Rectangular Tank with Various Baffle Heights (배플의 높이 변화에 따른 3 차원 사각 탱크 내부의 슬로싱 현상에 관한 수치적 연구)

  • Lee, Chang-Yeol;Yoon, Hyun-Sik;Jung, Jae-Hwan
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.47 no.1
    • /
    • pp.38-46
    • /
    • 2010
  • This study aims at investigating the effect of the baffle height on the liquid sloshing in the three-dimensional (3D) rectangular tank. In order to simulate the 3D incompressible viscous two-phase flow in the 3D tank with partially filled liquid, the present study has adopted the volume of fluid (VOF) method based on the finite-volume method which has been well verified by comparing with the results of the relevant previous researches. The ratio of the baffle height ($h_B$) to filling level (h) has been changed in the range of $0{\leq}h_B/h{\leq}1.2$ to observe the effect on the impact loads on the side wall and free surface behavior. Generally, as baffle height increases, the impact pressure on the wall decreases and the deformation of free surface becomes weaker. However it seemed that a critical ratio of the baffle height existed to reveal the lowest impact pressure on the wall. Consequently, $h_B/h=0.8$ among $h_B/hs$ considered in the study showed the lowest impact pressure.

Study on the Performance Characteristics with the Height of a Regenerator and Dehumidifier for Liquid Desiccant Dehumidification System (액체식 제습시스템을 위한 재생기와 제습기의 높이에 따른 성능특성에 관한 연구)

  • 이수동;박문수;정진은;최영석
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.7
    • /
    • pp.630-638
    • /
    • 2004
  • Liquid desiccant dehumidification systems have the ability to provide efficient humidity and temperature control while saving the electrical energy requirement for air conditioning as compared to a conventional system. The dehumidifier and the regenerator form the heart of this system. The latent part of the cooling load is overcome using liquid desiccant. The model regenerator has been designed to study the absorption characteristic of the aqueous triethylene glycol (TEG) solution which is in the flow range from 20 to 50 LPM. Also, this system designed that was able to change the height of the regenerator and dehumidifier. Because the effect of performance have different result according the height. The effect of performance factors of the regenerator with inlet solution flow rate, air flow rate, solution concentration, solution temperature, brine temperature, air temperature and inlet air relative humidity have been analyzed. Data obtained are useful for design guidance and performance analysis of the hybrid air conditioning system.