• 제목/요약/키워드: Liquid Cooling System

검색결과 366건 처리시간 0.036초

등가회로 해석법에 의한 환단면형 유도전자펌프의 설계 (A design of the annular induction electromagnetic pump by equivalent circuit modelling)

  • 김희령;홍상희;황종선;민병태;남호윤;조만
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1994년도 하계학술대회 논문집 C
    • /
    • pp.1431-1434
    • /
    • 1994
  • The annular induction electromagnetic pump with maximum flowrate of $60{\ell}/min$ for the sodium coolant system of liquid metal fast breeder reacters has been designed using the equivalent circuit method. The final optimum values of geometrical and electromagnetic parameters were obtained for an annular induction pump from the relation of the electrical variables giving the developing force to the fluid and the pressure drops between both sides of the pump. The physical properties of the core, coil condoctor materials in the high temperature and pump cooling systems under operation have been taken into account in the design of the pump. The structural material were also selected considering the reaction with sodium and the magnetic field distortion.

  • PDF

Conceptual Design of an HTS large power transformer with continuously transposed coated conductors

  • Lee, Se-Yeon;Park, Sang-Ho;Kim, Woo-Seok;Lee, Ji-Kwang;Park, Il-Han;Chol, Kyeong-Dal;Hahn, Song-Yop
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제13권2호
    • /
    • pp.5-8
    • /
    • 2011
  • This paper shows results of a design work of a program that is to develop a large power single phase high temperature superconducting (HTS) transformer. The program forms a part of a national project in Korea. A target of the design work is an HTS power transformer with rated voltages of 154 kV/22.9 kV and material for windings is supposed to be coated conductor. The design results presents in this paper will include: 1)HTS winding structures for high voltage in liquid nitrogen, 2)design result of continuously transposed coated conductor (CTCC), 3)conceptual design of high voltage bushings, 4)cooling system. A feasibility study will succeed to this design work for construction of a prototype HTS power transformer with capacity/voltage of 33 MVA/154 kV.

소형 비가열 실험을 이용한 원자로용기 외벽냉각시 용기와 단열재 사이의 자연순환 이상유동에 관한 연구 (A Non-Heating Small-Sclaed Experimental Study on the Two-Phase Natural Circulation Flow through an Annular Gap between Reactor Vessel and Insulation)

  • 하광순;박래준;조영로;김상백;김희동
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 춘계학술대회
    • /
    • pp.1927-1932
    • /
    • 2004
  • A 1/21.6 scaled non-heating experimental facility was prepared utilizing the results of a scaling analysis to simulate the APR1400 reactor and insulation system. The behaviors of the air bubble-induced two-phase natural circulation flow in the insulation gap were observed, and the liquid mass flow rates driven by natural circulation loop were measured by varying the injected air flow rate and distribution. As the injected air flow rates increased, the natural circulation flow rates also increased. Both the longitudinal and the latitudinal distributions of the injected air affected the natural circulation flow rates, especially, the longitudinal effect is more larger.

  • PDF

Experimental and Theoretical Studies on the Dynamic Characteristics During Speed Down of Inverter Heat Pump

  • Hwang, Yoon-Jei;Kim, Ho-Young
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제8권1호
    • /
    • pp.29-39
    • /
    • 2000
  • A series of tests were performed to verify the transient characteristics of heat pump in heating and cooling mode when operating speed was varied over the 30 to 102Hz. One of the major issues that has not been addressed so far is transient characteristics during speed modulation. The model for cycle simulation has been developed to predict the cycle performance under conditions of decreasing drive frequency and the results of the theoretical study were compared with the results of the experimental study. The simulated results were in good agreement with the experimental result within 10%. The transient cycle migration of the liquid state refrigerant causes significant dynamic change in system. Thus, the migration of refrigerant was the most important factor whenever do experimental results analysis or develop simulation model.

  • PDF

전산기(電算機)를 이용(利用)한 주물(鑄物)의 응고해석(凝固解析)에 관하여 (A Analysis of Solidification of Castings by Computer)

  • 윤의박;조순형
    • 한국주조공학회지
    • /
    • 제3권2호
    • /
    • pp.83-91
    • /
    • 1983
  • In this paper analytical and numerical methods fur analysis of solidification of castings are described, and the matrix method, one of numerical method, where the nodal point is designated on the element boundary was adapted. The cooling curve obtained by experimental values, when cast steel (0.29%C. 0.62%Si) was poured into $CO_2$ mold, is compared with that of computed values by exploiting computer (V77-600 Data Proceeding System, UNIVAC). The computed value is nearly approximation to the experimental. But the computed value shows a tendency that is a little higher than the experimental in solid-liquid coexisting temperature ranges and much lower than the experimental after solidification. It is considered to result from the lacks and difficulties of ultimately appropriate adaptation of various physical properties and also air cap between castings and mold.

  • PDF

초전도변압기의 계통적용을 위한 예상 시장진입가격 추정 (Evaluate the expected price of HTS transformer for introducing into korean power system)

  • 김종율;이승렬;윤재영
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.176-178
    • /
    • 2004
  • HTS (High Temperature Superconducting) Transformer has the several useful characteristics in the viewpoints of technical and economical. Especially, an HTS transformer replaces the copper wire coils in a conventional transformer with lower loss HTS wire In addition, inexpensive, environmentally benign liquid nitrogen replaces the conventional oil as the electrical insulation (dielectric) and provides the necessary cooling for the HTS transformer Therefore, the Life-cycle cost of an HTS transformer is much more attractive than conventional because it is more energy efficient, lighter in weight, smaller in size, and environmentally compliant. HTS transformer can be the best way to replace with conventional transformer in the future. In this paper, we investigate the expected price of HTS transformer to have a merit in viewpoint of economic aspect. First, life-cycle cost of conventional transformer is calculated and based on this, the expected price of HTS transformer is evaluated, which HTS transformer is competitive against conventional transformer.

  • PDF

Dynamics Modeling of a Gas Engine-Driven Heat Pump in Cooling Mode

  • Shin Younggy;Yang Hooncheul;Tae Choon-Seob;Jang Cheol-Yong;Cho Soo
    • Journal of Mechanical Science and Technology
    • /
    • 제20권2호
    • /
    • pp.278-285
    • /
    • 2006
  • The present study has been conducted to simulate dynamics of a gas engine-driven heat pump (GHP) for design of control algorithm. The dynamics modeling of a GHP was based on conservation laws of mass and energy. For automatic control of refrigerant pressures, actuators such as engine speed, outdoor fans, coolant three-way valves and liquid injection valves were PI or P controlled. The simulation results were found to be realistic enough to apply for control algorithm design. The model can be applied to build a virtual real-time GHP system so that it interfaces with a real controller in purpose of prototyping control algorithm.

심자도 장비의 냉각장치 특성 최적화를 위한 기하 설계 변수 연구 (A Study on the Geometric Design Parameters for Optimization of Cooling Device in the Magnetocardiogram System)

  • 이정희;이영신;이용호;임현균;이성진
    • 대한기계학회논문집A
    • /
    • 제34권2호
    • /
    • pp.153-160
    • /
    • 2010
  • 인체의 심장 활동에 의해 발생되는 생체 자기 신호를 심자도(magnetocardio-gram, MCG)라고 부른다. 이러한 생체자기장은 극저온 상태에서 고감도 자장센서인 SQUID(Superconducting QUantum Interference Device)를 사용함으로서 측정할 수 있다. 이 심자도 장비의 냉각장치는 액체 헬륨을 냉매로 사용하며 이 냉매를 보관하는 방법이 장비의 성능을 좌우한다. 액체 저온 듀아가 극저온 4 K에서 초전도 특성을 유지하기 위하여 사용된다. 본 연구에서는 액체 헬륨 듀아의 온도분포 특성이 연구되었다. 본 연구에서 사용된 듀아는 액체헬륨 용량이 30 L이고 5일간 유지된다. 듀아에는 150 K와 40 K의 이중 차폐체가 설치되었다. 열차폐체 끝단에서의 온도가 측정되었으며 전산모델의 해석결과와 비교되었다. 기하 설계 변수에 대한 최적화 기법을 적용하여 냉각장치인 저온 듀아의 열전단율을 최소화하였으며 듀아의 응력분포에 영향을 갖는 설계 기하 변수들의 특성을 연구하였다. 냉각장치의 열해석 및 최적화해석을 위해 유한요소 코드 ANSYS 10을 사용하였다. 저온 듀아에 사용된 전산모델은 열복사에 의한 영향을 최소화 할 수 있는 분야에서 온도 분포를 예측하는데 유용하게 사용될 수 있다.

초고속 비행체 냉각을 위한 연료의 흡열성능 개선용 성형촉매 적용연구 (Improvement of Endothermic Characteristics with Catalyst Molding in Hypersonic Aircraft Cooling System)

  • 현동훈;이태호;김성현;정병훈;한정식
    • 한국추진공학회지
    • /
    • 제21권3호
    • /
    • pp.56-60
    • /
    • 2017
  • 극초음속 비행체에서는 공기와의 마찰열과 엔진열의 증가로 기체 내부의 열적 부하가 발생한다. 이는 비행체 내부 구조물의 변형을 일으키고 오작동을 발생시킬 수 있다. 흡열연료는 액체 탄화수소 연료로 흡열반응을 통해 열을 흡수할 수 있는 연료이다. 본 연구에서는 exo-tetrahydrodicyclopentadiene을 모델연료로 선정하고 흡열 냉각 시스템에 제올라이트 촉매를 사용하여 흡열반응을 수행하였다. 세가지 형태로 촉매를 성형하여 각 형태별 흡열 성능 차이를 관찰하였다. 본 연구에서 바인더가 첨가된 촉매가 더 높은 흡열량과 전환율을 보였다. 생성물 분석 결과 바인더 첨가 촉매에서 방향족의 생성이 더 많은 것을 확인하였다.

동결농축법을 이용한 염수 및 중금속 수용액의 동결거동에 관한 실험 연구 (An Experimental Study on Freezing Behavior of NaCl and Heavy Metal Aqueous Solution Using Freeze Concentration Method)

  • 김정식;임승택;오철
    • 한국항해항만학회지
    • /
    • 제37권2호
    • /
    • pp.129-135
    • /
    • 2013
  • 동결농축폐수처리의 기술은 열역학적 효율이 높고 에너지 소비량이 작아 중소규모로 적합하며, 용수 재활용과 융해열의 냉열 재이용이 가능한 장점을 가지고 있다. 본 연구에서는 폐수 처리효율이 높은 동결농축폐수처리장치의 개발을 위해 수직원관 형태의 제빙관을 대상으로 염화나트륨수용액을 이용한 기초 실험을 통해 냉각면 온도, 기포 분사 방법에 따른 분리 성능을 확인 후 대표적 중금속인 Pb, Cr 수용액을 대상으로 냉각면 온도, 기포 직접 분사, 과냉각을 방지하기 위한 용질을 포함하지 않은 초기 빙층 두께의 영향에 따른 중금속 분리 성능을 실험 통해 확인하였다. 실험결과 두 수용액에서 모두 냉각면의 온도가 낮을수록 동결층의 성장속도가 빨라지고 용질의 분리효율이 저하되었다. 기포를 분사하는 방법 중에는 환모양의 노즐을 통해 동결계면에 직접 분사하는 방법이 원통벽면을 통해 간접 분사하는 것 보다 분리효율이 높게 나타났으며, 초기 빙층의 두께에 따른 실험에서는 1mm 보다는 5mm의 두께에서 분리효율이 더 우수한 것으로 나타났다.