• Title/Summary/Keyword: Liquid Cooling System

검색결과 365건 처리시간 0.031초

유한요소법을 이용한 수평형 다단원심펌프의 내진해석 (Seismic Analysis of Horizontal-Type Multi-Stage Centrifugal Pump using Finite Element Method)

  • 조진래;이홍우;김민정;하세윤
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제27권6호
    • /
    • pp.790-796
    • /
    • 2003
  • As a fluid machinery for piping liquid in the reactor cooling system, multi-stage centrifugal pump requires the structural dynamic stability against external dynamic excitation. This paper is concerned with the finite element analysis of its eigen behavior and seismic response to RRS(Required Response Spectrum) curves in the case of SSE (Safe Shutdown Earthquake). Through the finite element analysis, the major vibration characteristics of multi-stage centrifugal pump(MSCP) are investigated and seismic qualification based on the IEEE codes is executed. The numerical results show that the MSCP used in this study has enough seismic strength.

Nano-sized Effect on the Magnetic Properties of Ag Clusters

  • Jo, Y.;Jung, M.H.;Kyum, M.C.;Park, K.H.;Kim, Y.N.
    • Journal of Magnetics
    • /
    • 제11권4호
    • /
    • pp.160-163
    • /
    • 2006
  • We have prepared crystalline Ag nanoparticles with an average size of 4 nm in diameter by using an inductively coupled plasma reactor equipped with the liquid nitrogen cooling system. Our magnetic data show that the nano-sized effect of Ag nanoparticles on the magnetic properties is ferromagnetic, instead of a diamagnetic component of the Ag bulk and a superparamagnetic component of magnetic nanoparticles. We have also studied the magnetic properties of Ag-Cu nanocomposites with an opposite concentration profile between surface and core. These comparisons indicate that the ferromagnetic component strongly depends on the surface of Ag nanoparticles, while the paramagnetic component is strongly affected by the outer oxide layer, with the background of a diamagnetic component from the core of Ag.

초전도 케이블용 절연재료의 절연파괴 특성과 기구에 관한 연구 (Study on the Breakdown Characteristics and Mechanisms of Insulating Material for Superconducting Cable)

  • 김현희;권영환;마대영;김상현
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1993년도 춘계학술대회 논문집
    • /
    • pp.44-48
    • /
    • 1993
  • Recently, superconducting cable has attracted a great deal of interest from the viewpoint of energy saving, one of the most important and difficult problems to be solved to assure the high reliability, safety and economy of cable is breakdown is cryogenic temperature. In this paper, we will report on the characteristics and mechanisms of the breakdown and creeping discharge in cryogenic liquids, dual role of those as the cooling and insulating material, and composited system of cryogenic liquid - gas taking into consideration for application.

  • PDF

Simulated winding temperature distribution of HTS transformer cooled by sub-cooled liquid nitrogen

  • Han, J.H.;Choi, K.D.;Kim, T.Y.;Chang, T.;Kim, W.S.;Kim, S.H.;Hahn, S.Y.;Kim, S.R.
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제6권4호
    • /
    • pp.51-54
    • /
    • 2004
  • A 1 MV A single phase high temperature superconducting (HTS) transformer was manufactured. In order to reduce AC loss generated in the HTS winding, winding was concentrically arranged. Operation temperature is set at 65K to increase the critical current and reduce the amount of HTS tape usage and the volume. The cryogenic system which consists of main cryostat with the windings and secondary cryostat with 2 GM coolers and cryopump on top and heat exchanger inside is also designed and the cooling performance is simulated with Fluent. Temperature distribution of the windings is investigated whether the windings are kept under designed operation temperature.

2단 냉동기의 냉각시간 단축을 위한 기체-간극 열스위치 설계 (Design of gas-gap thermal switch for reducing cooldown time of 2-stage cryocooler)

  • 김형진;장호명
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 2000년도 KIASC Conference 2000 / 2000년도 학술대회 논문집
    • /
    • pp.35-38
    • /
    • 2000
  • A preliminary design of gas-gp thermal switch is presented to reduce the cooldown time of superconducting system conduction-cooled by a two-stage refrigerator without liquid cryogens. The switch connects thermally the first and the second stages (ON) to take advantage of the larger refrigeration capacity at the first stage during the beginning period. After the cryogenic temperature is reached, the switch should isolate thermally the two stages (OFF) in order to reduce the heat leak to the cold end. In this paper, a new concept for the performance index is introduced to evaluate the reduction of the cooldown time and the increase of the cooling load at the same time. In addition, the design of a gas-gap switch is discussed as a closed container of several staggered concentric tubes filled with gas, which is frozen at low temperatures for the shut-off of heat without any mechanical actuation. Some of the detailed features in the design is quantitative investigated by the gas convection model in the continuum or the rarefied gas region.

  • PDF

삼중효용 흡수사이클의 성능특성 평가 (evaluation of Performance Characteristic on Triple Effect Absorption Cycle)

  • 권오경
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제22권6호
    • /
    • pp.782-791
    • /
    • 1998
  • This paper presents a computer simulation of five types of triple effect absorption cycles employ-ing the refrigerant absorbent combinations of NH3/LiNO3 low-pressure type NH3/LiNO3+H2O/LiBr binary two-stage type series flow cycle and two types of parallel flow cycle for H2O/LiBr. The absorption systems is investigated through cycle simulation to obtain the system characteristics with the cooling water inlet temperature approach temperature of absorber loss temperature of absorber and chilled water outlet temperature. The most important characteristic temperature of absorber and chilled water outlet temperature. The most important characteristic of NH3/LiNO3 low-pressure type and a NH3/LINO3+H2O/LiBr binary two-stage type is that it obtains a coefficient of performance higher than the sum of the performance coefficients of its part operating independently. As a result of this analysis the optimum designs and operating conditions were determined based on the operating conditions and the coefficient of performance.

  • PDF

MAGMAsoft를 이용한 Aircon Compressor Front Housing의 다이캐스팅 주조공정설계 (Die Casting Process Design for Front Housing of Aircon Compressor by Using MAGMAsoft)

  • 공성락;박진영;김억수;문영훈
    • 소성∙가공
    • /
    • 제9권4호
    • /
    • pp.413-420
    • /
    • 2000
  • In the die casting process, the flow of liquid metal has significant influence on the quality of casting products and die life. For the optimal process design of front housing part of aircon compressor, various analyses were performed in this study by using computer simulation code, MAGMAsoft. The simulation has been focused on the molten metal behaviors during the filling and solidification stages for the sound casting products. Two cases of casting design that have different types of gating system are considered in the analysis. The potential sites where the casting defects may occur is examined by computer simulation and an improved design process is proposed. Also the effect of partial squeeze on the quality of casting products is considered and the optimal time lag after filling process is determined. For the die-stability, the effect of operational parameters such as die temperature, heat cycle and spot cooling on the die life has also been analyzed.

  • PDF

Thermo-Diode식 태양열 이용 모듈(Smart Module)개발 (Development of Energy Efficient Smart Module with Variable Direction of Heat Flow, Heat Capacity and Surface Absorptivity)

  • 이경진;천원기
    • 태양에너지
    • /
    • 제18권3호
    • /
    • pp.119-128
    • /
    • 1998
  • 본 연구에서는 열흐름의 방향, 태양 복사열의 집열 그리고 축열부의 열용량 등이 조절 가능한 Thermo-Diode식 태양열 이용 모듈(Smart Module)의 개발하였으며, 이를 통하여 액체식 열다이오드에 대한 작동 메카니즘과 이를 적용한 태양열 이용 시스템의 효율적 작동과 그 가능성을 확인하였다. 기존의 태양열 시스템은 일조시간 동안만 시스템이 운용되는 반면 본 Smart Module은 낮뿐만 아니라 밤에도 단열 및 냉방부하 감소 효과를 거둘 수 있다.

  • PDF

태양열에 의한 냉방 및 난방시스템의 성능향상 (III) - 성층화계수의 예측을 위한 1차원 해석모델의 개발 - (The Improvement of the Performance of Solar Cooling and Heating Systems (III) - Development of One Dimensional Analytic Model for the Evaluation of Stratification Coefficients -)

  • 유재경;노승탁;이준식;정석호
    • 설비공학논문집
    • /
    • 제1권1호
    • /
    • pp.55-63
    • /
    • 1989
  • A one dimensional analytic model for the prediction of the stratification coefficient of a liquid-based solar heating system is developed. The stratification coefficient, $K_s$, is defined as the ratio of the actual useful energy gain to the energy gain that would be achieved if there were no thermal stratification in the storage tank. Previous studies incorporated only collector-side effects, but in this study both the collector and load-side effects are included for the overall performance evaluation.

  • PDF

등가회로 해석법에 의한 환단면형 유도전자펌프의 설계 (A design of the annular induction electromagnetic pump by equivalent circuit modelling)

  • 김희령;홍상희;황종선;민병태;남호윤;조만
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1994년도 하계학술대회 논문집 C
    • /
    • pp.1431-1434
    • /
    • 1994
  • The annular induction electromagnetic pump with maximum flowrate of $60{\ell}/min$ for the sodium coolant system of liquid metal fast breeder reacters has been designed using the equivalent circuit method. The final optimum values of geometrical and electromagnetic parameters were obtained for an annular induction pump from the relation of the electrical variables giving the developing force to the fluid and the pressure drops between both sides of the pump. The physical properties of the core, coil condoctor materials in the high temperature and pump cooling systems under operation have been taken into account in the design of the pump. The structural material were also selected considering the reaction with sodium and the magnetic field distortion.

  • PDF