• Title/Summary/Keyword: Liquid Chromatography-tandem Mass Spectrometry

Search Result 398, Processing Time 0.027 seconds

Quantitative Analysis of the Seventeen Marker Components in Dangguisu-san Using Ultra-performance Liquid Chromatography Coupled to Electrospray Ionization Tandem Mass Spectrometry (LC-MS/MS를 이용한 당귀수산 추출물 중 17종 성분의 함량분석)

  • Seo, Chang-Seob;Shin, Hyeun-Kyoo
    • YAKHAK HOEJI
    • /
    • v.58 no.3
    • /
    • pp.158-164
    • /
    • 2014
  • Dangguisu-san is a well-known traditional Korean herbal medicine prescription and has been widely used to treat ecchymosis, blood stagnation, and pain resulting from physical shock in Korea. In this study, an ultra-performance liquid chromatography-electrospray ionization-mass spectrometer method was established for the simultaneous determination of the 17 biomarker components in Dangguisu-san. All analytes were separated on an UPLC BEH $C_{18}$ ($100{\times}2.1$ mm, $1.7{\mu}m$) column and maintained at $45^{\circ}C$. The mobile phase consisted of two solvent systems, 0.1% (v/v) formic acid in water (A) and acetonitrile (B) by gradient flow. The injection volume was $2.0{\mu}l$ and the flow rate was 0.3 ml/min with detection at mass spectrometer. Calibration curves of the 17 biomarker components were acquired with $r^2$ values ${\geq}0.9951$. The values of limit of detection and quantification of all analytes were 0.02~6.32 ng/ml and 0.05~18.95 ng/ml, respectively. The amounts of the 17 components in Dangguisu-san sample were $3.17{\sim}13,224.50{\mu}g/g$.

Liquid chromatography-tandem mass spectrometric analysis of oleracone D and its application to pharmacokinetic study in mice

  • Lim, Dong Yu;Lee, Tae Yeon;Lee, Jaehyeok;Song, Im-Sook;Han, Young Taek;Choi, Min-Koo
    • Analytical Science and Technology
    • /
    • v.34 no.5
    • /
    • pp.193-201
    • /
    • 2021
  • We have demonstrated a sensitive analytical method of measuring oleracone D in mouse plasma using a liquid chromatography-tandem mass spectrometry (LC-MS/MS). Oleracone D and oleracone F (internal standard) in mouse plasma samples were processed using a liquid-liquid extraction method with methyl tertbutyl ether, resulting in high and reproducible extraction recovery (80.19-82.49 %). No interfering peaks around the peak elution time of oleracone D and oleracone F were observed. The standard calibration curves for oleracone D ranged from 0.5 to 100 ng/mL and were linear with r2 of 0.992. The inter- and intra-day accuracy and precision and the stability fell within the acceptance criteria. The pharmacokinetics of oleracone D following intravenous and oral administration of oleracone D at doses of 5 mg/kg and 30 mg/kg, respectively, were investigated. When oleracone D was intravenously injected, it had first-order elimination kinetics with high clearance and volume of distribution values. The absolute oral bioavailability of this compound was calculated as 0.95 %, with multi-exponential kinetics. The low aqueous solubility and a high oral dose of oleracone D may explain the different elimination kinetics of oleracone D between intravenous and oral administration. Collectively, this newly developed sensitive LC-MS/MS method of oleracone D could be successfully utilized for investigating the pharmacokinetic properties of this compound and could be used in future studies for the lead optimization and biopharmaceutic investigation of oleracone D.

Comparative analysis of urinary metabolites in methamphetamine self-administrated rats

  • Choi, Boyeon;Kim, Soo Phil;Jang, Choon-Gon;Yang, Chae Ha;Lee, Sooyeun
    • Analytical Science and Technology
    • /
    • v.30 no.3
    • /
    • pp.122-129
    • /
    • 2017
  • Methamphetamine addiction is a critical issue due to the lack of effective pharmacotherapy and high potential for relapse. Nevertheless, there are no distinct biomarkers for diagnosis or prognosis for methamphetamine addiction. In the present study, a rat model for methamphetamine self-administration was established and alteration of urinary metabolites by methamphetamine addiction was investigated by the targeted metabolite analysis using mass spectrometry. Rat urine samples were collected at three time points (before and after addiction and after extinction) from the methamphetamine-addicted group as well as the age-matched control group. The collected samples were prepared using AbsoluteIDQ p180 kit and analyzed using flow injection analysis (FIA) - or high performance liquid chromatography (HPLC) - tandem mass spectrometry (MS/MS). The levels of lysine, acetylornithine and methioninesulfoxide were distinctively altered depending on the status of metheamphetamine addiction or extinction. In particular, the level of acetylornithine was reversely changed from addiction to extinction, for which further studies could be useful for biomarker discovery or mechanistic studies for methamphetamine addiction.

A Fast Determination of Globotriaosylsphingosine in Plasma for Screening Fabry Disease Using UPLC-ESI-MS/MS

  • Yoon, Hye-Ran
    • Mass Spectrometry Letters
    • /
    • v.6 no.4
    • /
    • pp.116-119
    • /
    • 2015
  • Globotriaosylsphingosine (lyso-Gb3) is considered as one of the biological marker for Fabry disease. To date, a reliable biomarker that reflects disease severity and progression has not been discovered to guide the management of Fabry disease. A new method included a simple protein precipitation with acetonitrile in 100 μL of plasma following analyte separation on an Phenomenex Kintex- C18 column using a gradient elution (0.1% formic acid in 5-90% acetonitrile). Total run time was within 12 min including sample preparation and MS/MS analysis. The limit of detection and limit of quantitation were 1 ng/mL and 2 ng/mL, respectively. The calibration curve was linear over the concentration range of 2.0-200.0 ng/mL (r2 = 0.9999). Inter-day accuracy and precision at 7 level were 93.4-100.7% with RSD of 0.55-5.97%. Absolute recovery was 97.6-98.6%. The method was applied to human and mice plasma, proved the suitability for quantification of lyso-Gb3 for screening, diagnosis and therapeutic monitoring of Fabry disease patients.

Effects of Mollugin on Hepatic Cytochrome P450 in Male ICR Mice as Determined by Liquid Chromatography/Tandem Mass Spectrometry

  • Song, Min;Hong, Miri;Choi, Hyun Gyu;Jahng, Yurngdong;Lee, Seung Ho;Lee, Sangkyu
    • Mass Spectrometry Letters
    • /
    • v.3 no.4
    • /
    • pp.104-107
    • /
    • 2012
  • Mollugin isolated from Rubia cordifolia is known to have anti-inflammatory, anti-cancer, and anti-viral activities. In the present study, a cocktail probe assay and LC-MS/MS were used to investigate the modulating effect of mollugin on cytochrome P450 (CYP) enzymes in male ICR mice. After mollugin was orally administrated to mice at the 20, 40, or 80 mg/kg for 3 days, the activities of CYP in hepatic S-9 fractions were investigated. Unlike the selective inhibitory effect of mollugin on CYP1A2-catalyzed phenacetin O-deethylation in vitro, mollugin only significantly inhibited the activity of CYP2E1-catalyzed chlorzoxazone 6-hydroxylase in vivo. The activities of other CYPs were only slightly altered by mollugin. The results of this study suggest that mollugin might cause herb-drug interactions via the selective inhibition of CYP2E1 in vivo.

A Sensitive and Rapid LC-MS/MS Method for Determination of Berberine in Human Plasma

  • Kim, Jae Hee;Mai, Xuan-Lan;Kim, Kyu Yeon;Sim, Min-Seok;Lee, So-Yeon;Seo, Hee-Won;Lee, Gunhee;Kim, Dae-Jung;Kim, Kyeong Ho
    • Mass Spectrometry Letters
    • /
    • v.10 no.2
    • /
    • pp.56-60
    • /
    • 2019
  • Coptidis Rhizoma (CR) has been used widely in traditional medicine to treat common diseases. This study aimed to develop a high-sensitivity liquid chromatography-tandem mass (LC-MS) spectrometry method for the evaluation of the pharmacokinetics of a new natural product that contain CR extract with the main bioactive compound, berberine, at trace concentrations. Human plasma samples were pretreated with methanol by a protein precipitation method. Berberine was analyzed on a Kinetex C18 column ($2.1mm{\times}50mm$, $100{\AA}$, $1.7{\mu}m$) using a mobile phase of 10 mM ammonium formate/0.1% formic acid in water (A) and acetonitrile (B) (50:50, v/v) with a flow rate of 0.25 mL/min. The analyte was detected by using electrospray ionization in positive mode with multiple reaction monitoring (MRM). The method was sensitive, with a lower limit of quantification of 1 pg/mL, which has not been previously obtained. The method was validated (over the range of 1-50 pg/mL) and applied successfully for the pharmacokinetic study of human plasma samples.

Development of Isotope Dilution-Liquid Chromatography/Tandem Mass Spectrometry as a Candidate Reference Method for the Determination of Acrylamide in Potato Chips

  • Park, Sun-Young;Kim, Byung-Joo;So, Hun-Young;Kim, Yeong-Joon;Kim, Jeong-Kwon
    • Bulletin of the Korean Chemical Society
    • /
    • v.28 no.5
    • /
    • pp.737-744
    • /
    • 2007
  • An isotope dilution-liquid chromatography/tandem mass spectrometric method was developed as a candidate reference method for the accurate determination of acrylamide in potato chips, starch-rich foodstuff cooked at high temperature. Sample was spiked with 13C3-acrylamide and then extracted with water. The extract was further cleaned up with an Oasis HLB solid-phase extraction (SPE) cartridge and an Oasis mixed-phase cation exchange (MCX) SPE cartridge. The extract was analyzed by using LC/ESI/Tandem MS in positive ion mode. LC with a medium reversed-phase (C4) column was optimized to obtain adequate chromatographic retention and separation of acrylamide. MS was operated to selectively monitor [M+H]+ ions of the analyte and its isotope analogue at m/z 72 and m/z 75, respectively. Sample was also analyzed by the LC/MS with selectively monitoring the collisionally induced dissociation channels of m/z 72 → m/z 55 and m/z 75 → 58. Compared to the LC/MS chromatograms, the LC/MS/MS chromatograms showed substantially reduced background chemical noises coming from solvent clusters formed during ESI spray processes and interferences from sample matrix. Repeatability and reproducibility studies showed that the LC/MS/MS method is a reliable and reproducible method which can provide a typical method precision of 1.0% while the LC/MS results are influenced by chemical interferences.

Analysis of Death Due to Poisoning in the National Capital Region (2014-2016) (수도권 부검시료에서 중독사 관련 사용물질 현황(2014-2016))

  • Park, Meejung;Park, Jongsin;Lee, Sangki;In, Sangwhan
    • Journal of The Korean Society of Clinical Toxicology
    • /
    • v.15 no.2
    • /
    • pp.101-106
    • /
    • 2017
  • Purpose: This study examined the patterns of drugs, poisons, and chemicals detected in autopsy samples performed in the Seoul Institute and other regional forensic offices of the National Forensic Service (NFS) between 2014 and 2016. Methods: The investigation carried out using the laboratory information management system. Forensic toxicological identification and quantitation were performed in autopsy samples, including heart blood, peripheral blood, liver, kidney, vitreous humor and etc. Gas chromatography/mass spectrometry (GC-MS) and liquid chromatography-tandem mass spectrometry (LC-MS/MS) were used to analyze the drugs and poisons. Results: Forensic autopsies were performed on 9,674 cases in this period. Based on the autopsy reports, 699 cases (7.2%) were considered as unnatural deaths caused by fatal intoxication. The number of male deaths was higher than that of female deaths, with the age of 50-59 being the most common age group. Conclusion: Drugs comprised the largest number of deaths due to poison, followed by alcohol, agrochemicals, drug with alcohol, carbon monoxide, and cyanide, in that order. Zolpidem was the most frequently used drug in all drug-related intoxication cases.

Characterization of the N-glycosylation of Recombinant IL-4 and IL-13 Proteins Using LC-MS/MS Analysis and the I-GPA Platform

  • Lee, Ju Yeon;Choi, Jin-woong;Bae, Sanghyeon;Hwang, Heeyoun;Yoo, Jong Shin;Lee, Joo Eon;Kim, Eunji;Jeon, Young Ho;Kim, Jin Young
    • Mass Spectrometry Letters
    • /
    • v.12 no.3
    • /
    • pp.66-75
    • /
    • 2021
  • Interleukin-4 (IL-4) and IL-13 are cytokines secreted by immune cells. Cytokines induce the proliferation of macrophages or promote the differentiation of secretory cells. The initiation and progression of allergic inflammatory diseases, such as asthma, are dependent on cytokines acting through related receptor complexes. IL-4 and IL-13 are N-glycoproteins. Glycan structures in glycoproteins play important roles in protein folding, protein stability, enzymatic function, inflammation, and cancer development. Therefore, the glycan structure of IL-4 and IL-13 needs to be elucidated in detail for the development of effective therapies. We report the first attempt to characterize the site-specific N-glycosylation of recombinant IL-4 and IL-13 via liquid chromatography-tandem mass spectrometry (LC-MS/MS) analysis. The tandem mass spectra of intact N-glycopeptides were identified using the Integrated GlycoProteome Analyzer (I-GPA) platform, which can automatically and rapidly analyze multiple N-glycopeptides, including their glycan composition and amino acid sequences. The recombinant IL-4 and IL-13 were identified with amino acid sequence coverages of 84% and 96%, respectively. For IL-4, 52 glycoforms on one N-glycosylation site were identified and quantified. In IL-13, 232 N-glycopeptides from three N-glycosylation sites were characterized, with the site Asn52 being the most extensively glycosylated (~80%). The complex glycans were the most abundant glycan on IL-4 and IL-13 (~96% and 91%, respectively), and the biantennary glycans were the most abundant in both recombinant IL-4 and IL-13 proteins.

A Survey of Total Aflatoxins in Food Using High Performance Liquid Chromatography-Fluorescence Detector (HPLC-FLD) and Liquid Chromatography Tandem Mass Spectrometry(LC-MS/MS) (HPLC-FLD 및 LC-MS/MS에 의한 식품 중 총아플라톡신 오염실태 조사)

  • Jang, Mi-Ran;Lee, Chang-Hee;Cho, Sung-Hye;Park, Joon-Shik;Kwon, Eun-Young;Lee, Eun-Jin;Kim, So-Hee;Kim, Dai-Byung
    • Korean Journal of Food Science and Technology
    • /
    • v.39 no.5
    • /
    • pp.488-493
    • /
    • 2007
  • A survey for total aflatoxins (aflatoxins $B_1$, $B_2$, $G_1$, and $G_2$) was conducted on 245 cereals and processed cereal products, and 148 nuts and processed nut products in Korea, for a total of 393 commercialized ed samples. The total aflatoxins were quantified by the immunoaffinity column clean-up method with high performance liquid chromatography (HPLC) - fluorescence detection (FLD), and were confirmed by liquid chromatography tandem mass spectrometry (LC-MS/MS). Total aflatoxins(AFs) were detected in 37 samples (9.4% incidence), including 2 millet samples, 1 mixed cereal (sunsik), 1 powdered malt sample, 2 processed cereal products, 6 peanut samples, 22 peanut butter samples, and 1 sample each of almonds, adlay tea, and a processed nut product. The contamination levels were $0.04-2.65{\mu}g/kg$ for aflatoxin $B_1$, and $0.04-5.51{\mu}g/kg$ for total aflatoxins. Finally, LC-MS/MS analysis of the contaminated samples was conducted to confirm the detected aflatoxins, and all 37 samples showing aflatoxins by HPLC-FLD were confirmed by LC-MS/MS.