• Title/Summary/Keyword: Liquid Chromatography-tandem Mass Spectrometry

Search Result 400, Processing Time 0.034 seconds

Discrimination Analysis of Production Year of Rice and Brown Rice based on Phospholipids (인지질을 이용한 쌀과 현미의 생산연도 판별 분석)

  • Hong, Jee-Hwa;Ahn, Jongsung;Kim, Yong-Kyoung;Choi, Kyung-Hu;Lee, Min-Hui;Park, Young-Jun;Kim, Hyun-Tae;Lee, Jae-Hwon
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.62 no.2
    • /
    • pp.105-112
    • /
    • 2017
  • The mixing of rice and brown rice produced in different years is banned in Korea by the grain management act. However, there has been no reported method for discriminating the production year of rice. The objective of this study was to develop a method for discriminating the production year of rice and brown rice based on their phospholipids content. One hundred rice samples and 130 brown rice samples produced between 2012 and 2015 were collected. Twelve phosphatidylcholine components were analyzed by liquid chromatography-tandem mass spectrometry. Phosphatidylcholine was used as an internal standard to calculate the peak intensity of the samples. A statistical analysis of the results showed that the centroid distance between the stale and new rice was 4.16 and the classification ratio was 97%. To verify the calculated discriminant, 61 and 40 rice samples were collected. The accuracy of discrimination was 82% by primary verification and 80% by secondary verification. The statistical analysis of brown rice showed that the centroid distance between the stale and new brown rice was 3.14 and the classification ratio was 96%. To verify the calculated discriminant, 10 samples of new rice and 30 samples of stale rice were collected and the accuracy of discrimination was 93%. The accuracy of discrimination for rice stored at room temperature was 57.9-92.1% and that for rice stored at a low temperature was 86.8-94.7%, depending on the storage period. For brown rice, the detection accuracy was 94.7-100% at room temperature and 92.1-100% at a low temperature, depending on the storage period. The accuracy of discrimination for rice was affected by the storage temperature and time, while that for brown rice was more than 92% regardless of the storage conditions. These results suggest that the developed discriminant analysis method could be utilized to determine the production year of rice and brown rice.

Simultaneous Determination of Penicillin Antibiotics in Meat using Liquid Chromatography Tandem Mass Spectrometry (LC-MS/MS를 이용한 육류 중 페니실린계 항생제 8종의 동시분석 및 적용성 검증)

  • Kim, Myeong-Ae;Yoon, Su-Jin;Kim, MeeKyung;Cho, Yoon-Jae;Choi, Sun-Ju;Chang, Moon-Ik;Lee, Sang-Mok;Kim, Hee-Jeong;Jeong, Jiyoon;Rhee, Gyu-Seek;Lee, Sang-Jae
    • Journal of Food Hygiene and Safety
    • /
    • v.29 no.2
    • /
    • pp.131-140
    • /
    • 2014
  • The objective of this study was to develop a simultaneous method of 8 penicillin antibiotics including amoxicillin, ampicillin, cloxacillin, dicloxacillin, nafcillin, oxacillin, penicillin G and penicillin V in meat using LC-MS/MS. The procedure involves solid phase extraction with HLB cartridge and subsequent analysis by LC-MS/MS. To optimize MS analytical condition of 8 compounds, each parameter was established by multiple reaction monitoring in positive ion mode. The chromatographic separation was achieved on a $C_{18}$ column with a mobile phase of 0.05% formic acid and 0.05% formic acid in acetonitrile at a flow rate of 0.2 mL/min for 20 min with a gradient elution. The developed method was validated for specificity, linearity, accuracy and precision in beef, pork and chicken. The recoveries were 71.0~106%, and relative standard deviations (RSD) were 4.0~11.2%. The limit of detection (LOD) and the limit of quantification (LOQ) were 0.003~0.008 mg/kg and 0.01~0.03 mg/kg, respectively, that are below maximum residue limit (MRL) of the penicillins. This study also performed survey of residual penicillin antibiotics for 193 samples of beef, pork and chicken collected from 9 cities in Korea. Penicillins were not found in all the samples except a sample of pork which contained cloxacillin (concentration of 0.08 mg/kg) below the MRL (0.3 mg/kg).

Method Development for Determination of Chlorogenic Acid and Arbutin Contents in Fruits by UHPLC-MS/MS (UHPLC-MS/MS를 이용한 과일류 중 클로로젠산 및 알부틴 동시분석법 개발)

  • Choi, Young-Ju;Jeon, Jong-Sup;Kim, Woon-Ho;Jung, You-Jung;Ryu, Ji-Eun;Choi, Jong-Chul;Chae, Kyung-Suk;Lee, Jin-Hee;Do, Young-Sook;Park, Young-Bae;Yoon, Mi-Hye
    • Journal of Food Hygiene and Safety
    • /
    • v.34 no.5
    • /
    • pp.413-420
    • /
    • 2019
  • In this study, a sample preparation method and a simultaneous determination method by ultra-high performance liquid chromatography coupled with tandem mass spectrometry for 9 isomers of chlorogenic acid and arbutin in fruits were developed. The samples were extracted using 90% methanol (pH 3.0), with the solutions being shaken and then sonicated for 10 min each. After centrifugation at 4,000 rpm for 10 min, the extraction was concentrated under a vacuum at $40^{\circ}C$ using a vacuum evaporator. The residue was dissolved in 5 mL of 5% methanol and filtered through a $0.45{\mu}m$ membrane before UHPLC-MS/MS analysis. The separations were performed on a C18 column with gradient elution of water (containing 0.1% formic acid) and methanol (containing 0.1% formic acid). The specificity, linearity, limit of detection, limit of quantification, accuracy, and precision of the proposed methods were also evaluated.

Development of Simultaneous Analytical Method for Streptomycin and Dihydrostreptomycin Detection in Agricultural Products Using LC-MS/MS (LC-MS/MS를 이용한 농산물 중 Streptomycin 및 Dihydrostreptomycin 동시시험법 개발)

  • Lee, Han Sol;Do, Jung-Ah;Park, Ji-Su;Park, Shin-Min;Cho, Sung Min;Shin, Hye-Sun;Jang, Dong Eun;Choi, Young-Nae;Jung, Yong-hyun;Lee, Kangbong
    • Journal of Food Hygiene and Safety
    • /
    • v.34 no.1
    • /
    • pp.13-21
    • /
    • 2019
  • A method was developed for the simultaneous detection of an antibiotic fungicide, streptomycin, and its metabolite (dihydrostreptomycin) in agricultural products using liquid chromatography-tandem mass spectrometry (LC-MS/MS). The samples were extracted using methanol adjusted to pH 3 using formic acid, and purified with a HLB (Hydrophilic lipophilic balance) cartridge. The matrix-matched calibration curves were constructed using seven concentration levels, from 0.001 to 0.1 mg/kg, and linearity of five agricultural products (hulled rice, potato, soybean, mandarin, green pepper), with coefficients of determination $(R^2){\geq}0.9906$, for streptomycin and dihydrostreptomycin. The mean recoveries at three fortification levels (LOQ, $LOQ{\times}10$, $LOQ{\times}50$, n = 5) were from 72.0~116.5% and from 72.1~116.0%, and relative standard deviations were less than 12.3% and 12.5%, respectively. The limits of quantification (LOQ) were 0.01 mg/kg, which are satisfactory for quantification levels corresponding with the Positive List System. All optimized results satisfied the criteria ranges requested in the Codex guidelines and the Food Safety Evaluation Department guidelines. The present study could serve as a reference for the establishment of maximum residue limits and be used as basic data for detection of streptomycin and dihydrostreptomycin in food.

Development and Validation of an Analytical Method for Fenpropimorph in Agricultural Products Using QuEChERS and LC-MS/MS (QuEChERS법과 LC-MS/MS를 이용한 농산물 중 Fenpropimorph 시험법 개발 및 검증)

  • Lee, Han Sol;Do, Jung-Ah;Park, Ji-Su;Cho, Sung Min;Shin, Hye-Sun;Jang, Dong Eun;Choi, Young-Nae;Jung, Yong-hyun;Lee, Kangbong
    • Journal of Food Hygiene and Safety
    • /
    • v.34 no.2
    • /
    • pp.115-123
    • /
    • 2019
  • An analytical method was developed for the determination of fenpropimorph, a morpholine fungicide, in hulled rice, potato, soybean, mandarin and green pepper using QuEChERS (Quick, Easy, Cheap, Effective, Rugged and Safe) sample preparation and LC-MS/MS (liquid chromatography-tandem mass spectrometry). The QuEChERS extraction was performed with acetonitrile followed by addition of anhydrous magnesium sulfate and sodium chloride. After centrifugation, d-SPE (dispersive solid phase extraction) cleanup was conducted using anhydrous magnesium sulfate, primary secondary amine sorbents and graphitized carbon black. The matrix-matched calibration curves were constructed using seven concentration levels, from 0.0025 to 0.25 mg/kg, and their correlation coefficient ($R^2$) of five agricultural products were higher than 0.9899. The limits of detection (LOD) and quantification (LOQ) were 0.001 and 0.0025 mg/kg, respectively, and the limits of quantification for the analytical method were 0.01 mg/kg. Average recoveries spiked at three levels (LOQ, $LOQ{\times}10$, $LOQ{\times}50$, n=5) and were in the range of 90.9~110.5% with associated relative standard deviation values less than 5.7%. As a result of the inter-laboratory validation, the average recoveries between the two laboratories were 88.6~101.4% and the coefficient of variation was also below 15%. All optimized results were satisfied the criteria ranges requested in the Codex guidelines and Food Safety Evaluation Department guidelines. This study could serve as a reference for safety management relative to fenpropimorph residues in imported and domestic agricultural products.

Development of simultaneous analytical method for investigation of ketamine and dexmedetomidine in feed (사료 내 케타민과 덱스메데토미딘의 잔류조사를 위한 동시분석법 개발)

  • Chae, Hyun-young;Park, Hyejin;Seo, Hyung-Ju;Jang, Su-nyeong;Lee, Seung Hwa;Jeong, Min-Hee;Cho, Hyunjeong;Hong, Seong-Hee;Na, Tae Woong
    • Analytical Science and Technology
    • /
    • v.35 no.3
    • /
    • pp.136-142
    • /
    • 2022
  • According to media reports, the carcasses of euthanized abandoned dogs were processed at high temperature and pressure to make powder, and then used as feed materials (meat and bone meal), raising the possibility of residuals in the feed of the anesthetic ketamine and dexmedetomidine used for euthanasia. Therefore, a simultaneous analysis method using QuEChERS combined with high-performance liquid chromatography coupled with electrospray ionization tandem mass spectrometry was developed for rapid residue analysis. The method developed in this study exhibited linearity of 0.999 and higher. Selectivity was evaluated by analyzing blank and spiked samples at the limit of quantification. The MRM chromatograms of blank samples were compared with those of spiked samples with the analyte, and there were no interferences at the respective retention times of ketamine and dexmedetomidine. The detection and quantitation limits of the instrument were 0.6 ㎍/L and 2 ㎍/L, respectively. The limit of quantitation for the method was 10 ㎍/kg. The results of the recovery test on meat and bone meal, meat meal, and pet food showed ketamine in the range of 80.48-98.63 % with less than 5.00 % RSD, and dexmedetomidine in the range of 72.75-93.00 % with less than 4.83 % RSD. As a result of collecting and analyzing six feeds, such as meat and bone meal, prepared at the time the raw material was distributed, 10.8 ㎍/kg of ketamine was detected in one sample of meat and bone meal, while dexmedetomidine was found to have a concentration below the limit of quantitation. It was confirmed that the detected sample was distributed before the safety issue was known, and thereafter, all the meat and bone meal made with the carcasses of euthanized abandoned dogs was recalled and completely discarded. To ensure the safety of the meat and bone meal, 32 samples of the meat and bone meal as well as compound feed were collected, and additional residue investigations were conducted for ketamine and dexmedetomidine. As a result of the analysis, no component was detected. However, through this investigation, it was confirmed that some animal drugs, such as anesthetics, can remain without decomposition even at high temperature and pressure; therefore, there is a need for further investigation of other potentially hazardous substances not controlled in the feed.

Improvement of an Analytical Method for Methoprene in Livestock Products using LC-MS/MS (LC-MS/MS를 이용한 축산물 중 살충제 메토프렌의 잔류분석법 개선)

  • Park, Eun-Ji;Kim, Nam Young;Park, So-Ra;Lee, Jung Mi;Jung, Yong Hyun;Yoon, Hae Jung
    • Journal of Food Hygiene and Safety
    • /
    • v.37 no.3
    • /
    • pp.136-142
    • /
    • 2022
  • The research aims to develop a rapid and easy analytical method for methoprene using liquid chromatography-tandem mass spectrometry (LC-MS/MS). A simple, highly sensitive, and specific analytical method for the determination of methoprene in livestock products (beef, pork, chicken, milk, eggs, and fat) was developed. Methoprene was effectively extracted with 1% acetic acid in acetonitrile and acetone (1:1), followed by the addition of anhydrous magnesium sulfate (MgSO4) and anhydrous sodium acetate. Subsequently, the lipids in the livestock sample were extracted by freezing them at -20℃. The extracts were cleaned using MgSO4, primary secondary amine (PSA), and octadecyl (C18), which were then centrifuged to separate the supernatant. Nitrogen gas was used to evaporate the supernatant, which was then dissolved in methanol. The matrix-matched calibration curves were constructed using 8 levels (1, 2.5, 5, 10, 25, 50, 100, 150 ng/mL) and the coefficient of determination (R2) was above 0.9964. Average recoveries spiked at three levels (0.01, 0.1, and 0.5 mg/kg), and ranged from 79.5-105.1%, with relative standard deviations (RSDs) smaller than 14.2%, as required by the Codex guideline (CODEX CAC/GL 40). This study could be useful for residue safety management in livestock products.

Development of a Simultaneous Analytical Method for Azocyclotin, Cyhexatin, and Fenbutatin Oxide Detection in Livestock Products using the LC-MS/MS (LC-MS/MS를 이용한 축산물 중 유기주석계 농약 Azocyclotin, Cyhexatin 및 Fenbutatin oxide의 동시시험법 개발)

  • Nam Young Kim;Eun-Ji Park;So-Ra Park;Jung Mi Lee;Yong Hyun Jung;Hae Jung Yoon
    • Journal of Food Hygiene and Safety
    • /
    • v.38 no.5
    • /
    • pp.361-372
    • /
    • 2023
  • Organotin pesticide is used as an acaricide in agriculture and may contaminate livestock products. This study aims to develop a rapid and straightforward analytical method for detecting organotin pesticides, specifically azocyclotin, cyhexatin, and fenbutatin oxide, in various livestock products, including beef, pork, chicken, egg, and milk, using liquid chromatography-tandem mass spectrometry (LC-MS/MS). The extraction process involved the use of 1% acetic acid in a mixture of acetonitrile and ethyl acetate (1:1). This was followed by the addition of anhydrous magnesium sulfate (MgSO4) and anhydrous sodium chloride. The extracts were subsequently purified using octadecyl (C18) and primary secondary amine (PSA), after which the supernatant was evaporated. Organotin pesticide recovery ranged from 75.7 to 115.3%, with a coefficient of variation (CV) below 25.3%. The results meet the criteria range of the Codex guidelines (CODEX CAC/GL 40). The analytical method in this study will be invaluable for the analysis of organotin pesticides in livestock products.

Vitamin D analysis in the Korean total diet study and UV/sun light irradiated mushrooms (한국형 총식이조사 및 UV/태양광 조사 버섯에서의 비타민 D 분석)

  • Min-Jeong Seo;In-Hwa Roh;Jee-Yeon Lee;Sung-Ok Kwon;Cho-Il Kim;Gae-Ho Lee
    • Food Science and Preservation
    • /
    • v.30 no.1
    • /
    • pp.109-121
    • /
    • 2023
  • This study was conducted to evaluate vitamin D intake of Koreans in a total diet study (TDS) and to determine the effect of irradiation on vitamin D synthesis in mushrooms. For analysis, sample were saponified and extracted with hexane, and vitamin D was quantified by liquid chromatography-tandem mass spectrometry (LC-MS/MS). Based on the validation results, the recovery of the National Institute of Standards and Technology (NIST) standard reference sample (SRM) 1849a was 96.7% and the z-score of -1.6 was obtained by the Food Analysis Performance Assessment Scheme (FAPAS) proficiency test (PT) 21115. Vitamin D2 was not detected in any samples, and the highest level of vitamin D3 was detected in mackerel and anchovies ranging from 24.2 to 120.2 ㎍/kg. The mean daily intake of vitamin D was 0.99 ㎍/day, as estimated from the vitamin D contents of the analyzed foods and their corresponding intake. The adequate intake (AI) of vitamin D based on the Dietary reference intakes for Koreans provided by the Ministry of Health and Welfare is 5-15 ㎍/day for Koreans aged 6 to 75 years. Compared with this AI, vitamin D intake of Koreans estimated in this study was inadequate. For that, the increased vitamin D content in ultraviolet (UV)/sun light irradiated mushrooms warrants further research to increase vitamin D intake of Koreans through diet.

Development and Validation of the Analytical Method for Oxytetracycline in Agricultural Products using QuEChERS and LC-MS/MS (QuEChERS법 및 LC-MS/MS를 이용한 농산물 중 Oxytetracycline의 잔류시험법 개발 및 검증)

  • Cho, Sung Min;Do, Jung-Ah;Lee, Han Sol;Park, Ji-Su;Shin, Hye-Sun;Jang, Dong Eun;Cho, Myong-Shik;Jung, ong-hyun;Lee, Kangbong
    • Journal of Food Hygiene and Safety
    • /
    • v.34 no.3
    • /
    • pp.227-234
    • /
    • 2019
  • An analytical method was developed for the determination of oxytetracycline in agricultural products using the QuEChERS (Quick, Easy, Cheap, Effective, Rugged and Safe) method by liquid chromatography-tandem mass spectrometry (LC-MS/MS). After the samples were extracted with methanol, the extracts were adjusted to pH 4 by formic acid and sodium chloride was added to remove water. Dispersive solid phase extraction (d-SPE) cleanup was carried out using $MgSO_4$ (anhydrous magnesium sulfate), PSA (primary secondary amine), $C_{18}$ (octadecyl) and GCB (graphitized carbon black). The analytes were quantified and confirmed with LC-MS/MS using ESI (electrospray ionization) in positive ion MRM (multiple reaction monitoring) mode. The matrix-matched calibration curves were constructed using six levels ($0.001{\sim}0.25{\mu}g/mL$) and coefficient of determination ($r^2$) was above 0.99. Recovery results at three concentrations (LOQ, $10{\times}LOQ$, and $50{\times}LOQ$, n=5) were from 80.0 to 108.2% with relative standard deviations (RSDs) less than of 11.4%. For inter-laboratory validation, the average recovery was in the range of 83.5~103.2% and the coefficient of variation (CV) was below 14.1%. All results satisfied the criteria ranges requested in the Codex guidelines (CAC/GL 40-1993, 2003) and the Food Safety Evaluation Department guidelines (2016). The proposed analytical method was accurate, effective and sensitive for oxytetracycline determination in agricultural commodities. This study could be useful for safety management of oxytetracycline residues in agricultural products.