• Title/Summary/Keyword: Liquid Chromatography Tandem Mass Spectrometry (LC-MS/MS)

Search Result 292, Processing Time 0.039 seconds

Determination of more than 500 Pesticide Residues in Hen Eggs by Liquid Chromatography-Tandem Mass Spectrometry (LC-MS/MS) and Gas Chromatography-Tandem Mass Spectrometry (GC/MS/MS)

  • Golge, Ozgur;Liman, Turan;Kabak, Bulent
    • Food Science of Animal Resources
    • /
    • v.41 no.5
    • /
    • pp.816-825
    • /
    • 2021
  • This study aims to validate a fast method of simultaneous analysis of 365 LCamenable and 142 GC-amenable pesticides in hen eggs by liquid chromatography-tandem mass spectrometry (LC-MS/MS) and gas chromatography-tandem mass spectrometry (GC-MS/MS), respectively, operating in multiple reaction monitoring (MRM) acquisition modes. The sample preparation was based on quick, easy, cheap, effective, rugged, and safe (QuEChERS) extraction. Key method performance parameters investigated were specificity, linearity, limit of quantification (LOQ), accuracy, precision and measurement uncertainty. The method was validated at two spiking levels (10 and 50 ㎍/kg), and good recoveries (70%-120%) and relative standard deviations (RSDs) (≤20) were achieved for 92.9% of LC-amenable and 86.6% of GC-amenable pesticide residues. The LOQs were ≤10 ㎍/kg for 94.2% of LC-amenable and 92.3% of GC-amenable pesticides. The validated method was further applied to 100 egg samples from caged hens, and none of the pesticides was quantified.

Determination of Liraglutide in Rat Plasma Using Selective Liquid Chromatography-Tandem Mass Spectrometry

  • Younah Kim;Hyoje Jo;Yelim Lee;Soo Yeon Kang;Sangkyu Lee
    • Mass Spectrometry Letters
    • /
    • v.14 no.4
    • /
    • pp.141-146
    • /
    • 2023
  • Liraglutide is a medication prescribed for the management of type 2 diabetes and chronic obesity. A simple, sensitive, and selective liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was developed and validated for the quantitative analysis of liraglutide in rat plasma. After a simple protein precipitation step, liraglutide was chromatographically separated using the ACQUITY Premier Peptide BEH C18 Column with mobile phases comprising 50% acetonitrile and 50% methanol, and water with 0.3% FA. Positive ion electrospray ionization in multiple reaction monitoring mode was used to achieve detection. Good linearity was observed in the 5-600 ng/mL concentration range (R2 > 0.99). Liraglutide had intra- and inter-day precision values of 2.13%-9.86% and 4.14%-8.36%, respectively. The accuracy ranged from -2.36% to 2.58%. The recovery and matrix effect were within acceptable limits. This selective LC-MS/MS method was used to study the pharmacokinetic properties of liraglutide after subcutaneous administration in rats.

Identification of Nandrolone and its Metabolite 5α-Estran-3β, 17α-Diol in Horse Urine after Chemical Derivatization by Liquid Chromatography Tandem Mass Spectrometry

  • Dubey, Saurabh;Beotra, Alka
    • Mass Spectrometry Letters
    • /
    • v.8 no.4
    • /
    • pp.90-97
    • /
    • 2017
  • Androgenic anabolic steroids (AASs) are synthetic derivatives of testosterone with a common structure containing cyclopentanoperhydrophenanthrene nucleus. Their use enhances the muscle building capacity and is beneficial during performance. The AASs are one of the most abused group of substances in horse doping. Liquid chromatography tandem mass spectrometry ($LC/MS^n$) has been successfully applied to the detection of anabolic steroids in biological samples. However, the saturated hydroxysteroids viz: nandrolone, $5{\alpha}-estrane-3{\beta}$, $17{\alpha}-diol$ exhibit lower detection responses in electrospray ionisation (ESI) because of their poor ionisation efficiency. To overcome this limitation pre-column chemical derivatization has been introduced to enhance their detection responses in $LC-ESI-MS^n$ analysis. The aim of present study was to develop a sensitive method for identification and confirmation of nandrolone and its metabolite in horse urine incorporating pre-column derivatization using picolinic acid. The method consists of extraction of targeted steroid conjugates by solid phase extraction (SPE). The eluted steroid conjugates were hydrolysed by methanolysis and free steroids were recovered with liquid-liquid extraction. The resulting steroids were derivatized to form picolinoyl esters and identification was done using LC-ESI-MS/MS in positive ionization mode. The picolinated steroid adduct enhanced the detection levels in comparison to underivatized steroids.

A New Analytical Method for Erythromycin in Fish by Liquid Chromatography/Tandem Mass Spectrometry

  • Park, Mi-Jung;Park, Mi-Seon;Lee, Tae-Seek;Shin, Il-Shik
    • Food Science and Biotechnology
    • /
    • v.17 no.3
    • /
    • pp.508-513
    • /
    • 2008
  • Erythromycin has been used to treat Streptococosis, Edwardsiel1osis, Vibriosis, Bacterial enteritis in the cultured fish. In this study, a rapid and effective erythromycin analysis method with new sample treatment protocol and liquid chromatography/tandem mass spectrometry (LC/MS/MS) system for fish products was developed. For the erythromycin extraction from fish muscle, the solvent mixture composed of 0.2% meta-phosphoric acid and methanol (6:4) showed good recovery rate, and the optimum extraction solvent volume was 20 mL. Erythromycin detection using LC/MS/MS were carried out under electro spray ionization (ESI) positive condition and erythromycin mass value 576.2 and 157.9. And the detection limit of the established method was 0.005 mg/kg in fish products. The recovery rate of the developed method applied to the fish species were as following, olive flounder, $87.6{\pm}5.0%$; black rockfish, $87.2{\pm}6.4%$; eel, $85.2{\pm}4.8%$; and rainbow trout, $86.0{\pm}6.2%$. In the established method in this study, the correlation of coefficient values ($R^2$) of erythromycin calibration curve (n=11) was 0.9998.

Liquid Chromatography-Tandem Mass Spectrometry Analysis of Riboflavin in Beagle Dog Plasma for Pharmacokinetic Studies

  • Jeong, Hyeon Myeong;Shin, Beom Soo;Shin, Soyoung
    • Mass Spectrometry Letters
    • /
    • v.11 no.1
    • /
    • pp.10-14
    • /
    • 2020
  • Riboflavin is a water-soluble vitamin, which serves as a precursor to flavin mononucleotide and flavin adenine dinucleotide. This study aimed to develop a simple and rapid liquid chromatography-tandem mass spectrometry (LC-MS/MS) analysis for the quantification of riboflavin in the Beagle dog plasma. This method utilized simple protein precipitation with acetonitrile and 13C4, 15N2-riboflavin was used as an internal standard (IS). For chromatographic separation, a hydrophilic interaction liquid chromatography (HILIC) column was used with gradient elution. The mobile phase consisted of 0.1% (v/v) aqueous formic acid with 10 mM ammonium formate and acetonitrile with 0.1% (v/v) formic acid. Since riboflavin is an endogenous compound, 4% bovine serum albumin in phosphate buffered saline was used as a surrogate matrix to prepare the calibration curve. The quantification limit for riboflavin in the Beagle dog plasma was 5 ng/mL. The method was fully validated for its specificity, sensitivity, accuracy and precision, recovery, and stability according to the US FDA guidance. The developed LC-MS/MS method may be useful for the in vivo pharmacokinetic studies of riboflavin.

Phospholipid Analysis by Nanoflow Liquid Chromatography-Tandem Mass Spectrometry

  • Moon, Myeong Hee
    • Mass Spectrometry Letters
    • /
    • v.5 no.1
    • /
    • pp.1-11
    • /
    • 2014
  • Lipids play important roles in biological systems; they store energy, play a structural role in the cell membrane, and are involved in cell growth, signal transduction, and apoptosis. Phospholipids (PLs) in particular have received attention in the medical and lipidomics research fields because of their involvement in human diseases such as diabetes, obesity, atherosclerosis, and many cancers associated with lipid metabolic disorders. Here I review experimental strategies for PL analysis based on nanoflow liquid chromatography-electrospray ionization-tandem mass spectrometry (nLC-ESI-MSn). In particular, discussed are lipid extraction methods, nanoflow LC separation of PLs, effect of ionization modifiers on the ESI of PLs, influence of chain lengths and unsaturation degree of acyl chains of PLs on MS intensity, structural determination of the molecular structure of PLs and their oxidized products, and quantitative profiling of PLs from biological samples such as tissue, urine, and plasma in relation to cancer and coronary artery disease.

Development of Analytical Method and Monitoring of Organophosphorus Pesticides in the Raw Water and Clean Water by Liquid Chromatography-Tandem Mass Spectrometry (LC/MS/MS를 이용한 유기인계 농약류의 최적 분석법 정립과 원·정수에서의 모니터링)

  • Kim, Gyung-A;Song, Mi-Jeong;Yeom, Hoon-Sik;Son, Hee-Jong;Lee, Sang-Won;Choi, Jin-Tack
    • Journal of Environmental Science International
    • /
    • v.24 no.12
    • /
    • pp.1569-1582
    • /
    • 2015
  • The analytical method for 16 organophosphorus pesticides was developed in this study. The 16 organophosphorus pesticides were analyzed by liquid chromatography-tandem mass spectrometry (LC/MS/MS) using on-line solid phase extraction (on-line SPE) with PLRP- S cartridge. Analysis of all analytes in the MS/MS was processed in the electrospray ioni-zation (ESI) positive mode. They are Azinphos ethyl, Chlorfenvinphos, Ethion, Famphur, Phosmet, Phosphamidon, Terbufos, Aspon, Chlorpyrifos-methyl, Crotoxyphos, Dichlofenthi-on, Dicrotophos, Fonofos, Thionazin, Dimethoate and Iprobenfos. Limits of detection (LODs) and Limits of quantification(LOQs) were obtained as 0.8~2.0 ng/L and 2.6~6.4 ng/L, respectively. All compounds were not detected at the 8 sampling points of the raw water and clean water.

Simultaneous and quantitative determination of anion biocides in soil by liquid chromatography-tandem mass spectrometry (토양 중 음이온 바이오사이드의 HPLC-MS/MS 동시 정량분석법)

  • Yang, Eun-Young;Shin, Ho-Sang
    • Analytical Science and Technology
    • /
    • v.28 no.5
    • /
    • pp.317-322
    • /
    • 2015
  • Simultaneous analytical method has developed for the determination of anion biocides in soil by liquid chromatography-tandem mass spectrometry (LC-MS/MS). Chlorite and chlorate in soil were extracted with pure water, and cyanuric acid and sodium dodecylbenzenesulfonate (Na-DBS) were extracted with mobile phase (0.25 mM ammonium formate in 20 mM formic acid : acetonitrile (1:1)). The extract was injected into the LC-MS/MS system after filtration. The method detection limits in this study were 0.04 mg/kg for chlorite, 0.04 mg/kg for chlorate, 0.27 mg/kg for cyanuric acid, and 0.05 mg/kg for Na-DBS, respectively. The method was applied to the analysis of 50 soil samples collected from 40 sites sprayed with biocides and 10 background sites. As a result, anion biocides were not detected in all sites.

Verification of Analytical Method of Azaspiracid Toxins in Shellfish and Tunicates by Liquid Chromatography-Tandem Mass Spectrometry (LC-MS/MS (Liquid Chromatography-Tandem Mass Spectrometry)를 이용한 패류 및 피낭류 중 아자스필산 분석법의 유효성 검증)

  • Cho, Sung Rae;Jeong, Sang Hyeon;Park, Kunbawui;Yoon, Minchul;Kim, Dong Wook;Son, Kwang Tae;Ha, Kwang Soo
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.54 no.4
    • /
    • pp.404-410
    • /
    • 2021
  • Although, mouse bioassay for the monitoring of azaspiracids (AZAs) toxins in shellfish has been used previously, the reported method has low sensitivity and it is time-consuming. Recently, there is an interest in the quantitative analysis of AZAs using liquid chromatography-tandem mass spectrometry (LC-MS/MS). The purpose of this study is to verify the simultaneous analysis of AZAs in shellfish and tunicate in Korea using LC-MS/MS. To validate the method, linearity, limit of detection (LOD), limit of quantification (LOQ), precision, accuracy, and repeatability were determined. All standard compounds were analyzed within 7 min. The correlation coefficients (R2) of the standard solution was higher than 0.9995 (within the range of 0.8-10.0 ㎍/L). The LODs and LOQs of AZAs in shellfish were 0.08-0.16 ㎍/kg and 0.23-0.50 ㎍/kg, respectively. The accuracy and precision of the method for determining AZAs in shellfish were 87.1-93.0% and 1.23-4.91%, respectively. Consequently, the verified LC-MS/MS method is suitable to analyze AZAs in shellfish and tunicates in Korea.

Optimization of Enzyme Digestion Conditions for Quantification of Glycated Hemoglobin Using Isotope Dilution Liquid Chromatography-Tandem Mass Spectrometry

  • Jeong, Ji-Seon
    • Mass Spectrometry Letters
    • /
    • v.5 no.2
    • /
    • pp.52-56
    • /
    • 2014
  • Glycated hemoglobin (HbA1c) is used as an index of mean glycemia over prolonged periods. This study describes an optimization of enzyme digestion conditions for quantification of non-glycated hemoglobin (HbA0) and HbA1c as diagnostic markers of diabetes mellitus. Both HbA0 and HbA1c were quantitatively determined followed by enzyme digestion using isotope dilution liquid chromatography-tandem mass spectrometry (ID-LC-MS/MS) with synthesized N-terminal hexapeptides as standards and synthesized isotope labeled hexapeptides as internal standards. Prior to quantification, each peptide was additionally quantified by amino acid composition analysis using ID-LC-MS/MS via acid hydrolysis. Each parameter was considered strictly as a means to improve digestion efficiency and repeatability. Digestion of hemoglobin was optimized when using 100 mM ammonium acetate (pH 4.2) and a Glu-C-to-HbA1c ratio of 1:50 at $37^{\circ}C$ for 20 h. Quantification was satisfactorily reproducible with a 2.6% relative standard deviation. These conditions were recommended for a primary reference method of HbA1c quantification and for the certification of HbA1c reference material.