• Title/Summary/Keyword: Linometer

Search Result 13, Processing Time 0.017 seconds

AMOUNT OF POLYMERIZATION SHRINKAGE AND SHRINKAGE STRESS IN COMPOSITES AND COMPOMERS FOR POSTERIOR RESTORATION (광중합형 구치부 수복재료의 중합수축량과 중합수축력)

  • Park, Sung-Ho;Lee, Soon-Young;Cho, Yong-Sik;Kim, Su-Sun;Lee, Chang-Jae;Kim, Young-Joo;Lee, Bong-Hee;Lee, Kouang-Sung;Noh, Byung-Duk
    • Restorative Dentistry and Endodontics
    • /
    • v.28 no.4
    • /
    • pp.348-353
    • /
    • 2003
  • The purpose of present study was to evaluate the polymerization shrinkage stress and amount of linear shrinkage of composites and compomers for posterior restoration. For this purpose, linear polymerization shrinkage and polymerization stress were measured. For linear polymerization shrinklage and polymerization stress measurement, custom made Linometer (R&B, Daejon, Korea) and Stress measuring machine was used (R&B, Daejon, Korea). Compositers and compomers were evaluated: Dyract AP (Dentsply Detrey, Gumbh. German) Z100 (3M Dental Products, St. Paul. USA) Surefil (Dentsply Caulk, Milford, USA) Pyramid (Bisco, Schaumburg, USA) Synergy Compact (Coltene, Altstatten, Switzerland), Heliomolar (Vivadent/Ivoclar, Liechtenstein), and Compoglass (Vivadent Ivoclar/Liechtenstein) were used. 15 measurements were made for each material. Linear polymerization shrinkage or polymerization stress for each material was compared with one way ANOVA with Tukey at 95% levels of confidence. For linear shrinkage: Heliomolar, Surefil

A STUDY OF CONTRACTION SHRINKAGE OF COMPOSITE RESINS AND ORMOCERS WITH VARIOUS CURING TIMES (광조사 시간에 따른 복합레진과 Ormocer의 중합수축에 관한 연구)

  • Chung, Yeon-Chung;Min, Kyung-San;Lee, Hae-Hyoung;Cho, Kyung-Mo;Cho, Yong-Bum
    • Restorative Dentistry and Endodontics
    • /
    • v.28 no.4
    • /
    • pp.326-333
    • /
    • 2003
  • Ormocer has organic-inorganic compound polymers. One of advantages of ormocer is reduced polymerization shrinkage. The purpose of this study was to compare the amount of contraction shrinkage of composite resins and ormocers. Additionally, the time of each material when there is no further change of contraction shrinkage was analysed. Four brands of composite resins (P-60. Surefil, Z-250 and Denfil) and two brands of ormocers (Definite and Admira) were used. 20 seconds, 40 seconds and 60 seconds of curing times were given. Contraction shrinkage of them were measured using a linometer for 80 seconds. The effect of material and curing time to contraction shrinkage at the time of 80 seconds was analysed by two-way ANOVA. The effect of time to contraction shrinkage was analysed by one-way ANOVA and the time when there was no further change of the contraction shrinkage was analysed. The results are as follows: 1. P-60, Definite, Z-250 and Denfil had no further change of contraction shrinkage from the time of 20 seconds, and Surefil and Admira had no further change of contraction shrinkage from the time of 10 seconds. 2. Statistical analysis revealed volumetric shrinkage varied among material (p<0,05). No significant difference of contraction shrinkage among different curing times was found, and there was no effect of interaction between materials and curing times to contraction shrinkage. 3. Definite and Admira showed the statistically same contraction shrinkage with those of Z-250 and P-60. which is higher than that of Surefil and lower than that of Denfil (p<0.05).

A study of polymerization shrinkage of composite resins cured by various light intensities

  • Lim, Mi-Young;Hong, Chan-Ui
    • Proceedings of the KACD Conference
    • /
    • 2003.11a
    • /
    • pp.613-613
    • /
    • 2003
  • The purpose of this study was to compare the effect of exponential curing method with conventional curing and two step soft start curing method on polymerization shrinkage of composite resins. Three brands of composite resins (Synergy Duo Shade, Z-250, Supreme) and three brands of light curing units (Spectrum 800, Elipar Highlight, Elipar Trillight) were used. In this study, the diameter of specimen was 5.5mm and height 1.6mm and the specimen was cured for 40 seconds. The shrinkage was measured by custom made linometer. The amount of linear polymerization shrinkage recorded in the computer every 0.5 second for 90 seconds. Each group was measured 10 times.(omitted)

  • PDF

EFFECT OF INTERMITTENT POLYMERIZATION ON THE RATE OF POLYMERIZATION SHRINKAGE AND CUSPAL DEFLECTION IN COMPOSITE RESIN (복합 레진의 간헐적 광중합 방법이 중합 수축 속도와 치아의 교두 변위에 미치는 영향)

  • Kim, Min-Kyung;Park, Sung-Ho;Seo, Deog-Gyu;Song, Yun-Jung;Lee, Yoon;Lee, Chan-Young
    • Restorative Dentistry and Endodontics
    • /
    • v.33 no.4
    • /
    • pp.341-351
    • /
    • 2008
  • This study investigated the effect of intermittent polymerization on the rate of polymerization shrinkage and cuspal deflection in composite resins. The linear polymerization shrinkage of each composite was measured using the custom-made linometer along with the light shutter specially devised to block the light at the previously determined interval. Samples were divided into 4 groups by light curing method; Group 1) continuous light (60s with light on); Group 2) intermittent light (cycles of 3s with 2s light on & 1s with light off for 90s): Group 3) intermittent light (cycles of 2s with 1s light on & 1s with light off for 120s); Group 4) intermittent light (cycles of 3s with 1s light on & 2s with light off for 180s). The amount of linear polymerization shrinkage was measured and its maximum rate (Rmax) and peak time (PT) in the first 15 seconds were calculated. For the measurement of cuspal deflection of teeth, MOD cavities were prepared in 10 extracted maxillary premolars. Reduction in the intercuspal distance was measured by the custom-made cuspal deflection measuring machine. ANOVA analysis was used for the comparison of the light curing groups and t-test was used to determine significant difference between the composite resins. Pyramid showed the greater amount of polymerization shrinkage than Heliomolar (p < 0.05). There was no significant difference in the linear polymerization shrinkage among the groups. The Rmax was group 4 < 3, 2 < 1 in Heliomolar and group 3 < 4 < 2, 1 in Pyramid (p < 0.05). Pyramid demonstrated greater cuspal deflection than Heliomolar. The cuspal deflection in Heliomolar was group 4 < 3 < 2, 1 and group 4, 3 < 2, 1 in Pyramid (p < 0.05). It was concluded that the reduced rate of polymerization shrinkage by intermittent polymerization can help to decrease the cuspal deflection.

POLYMERIZATION SHRINKAGE OF COMPOSITE RESINS CURED BY VARIABLE LIGHT INTENSITIES (가변 광도 중합에 따른 복합레진의 중합수축에 관한 연구)

  • Lim, Mi-Young;Cho, Kyung-Mo;Hong, Chan-Ui
    • Restorative Dentistry and Endodontics
    • /
    • v.32 no.1
    • /
    • pp.28-36
    • /
    • 2007
  • The purpose of this study was to compare the effect of exponential curing method with conventional curing and soft start curing method on polymerization shrinkage of composite resins. Three brands of composite resins (Synergy Duo Shade, Z250, Filtek Supreme) and three brands of light curing units (Spectrum 800, Elipar Highlight, Elipar Trilight) were used. 40 seconds curing time was given. The shrinkage was measured using linometer for 90 seconds. The effect of time on polymerization shrinkage was analysed by one-way ANOVA and the effect of curing modes and materials on polymerization shrinkage at the time of 90s were analysed by two-way ANOVA. The shrinkage ratios at the time of 20s to 90s were taken and analysed the same way. The results were as follows : 1. All the groups except Supreme shrank almost within 20s Supreme cured by soft start and exponential curing had no further shrinkage after 30s (p < 0.05). 2. Statistical analysis revealed that polymerization shrinkage varied among materials (p = 0.000) and curing modes (p = 0.003). There was no significant interaction between material and curing mode. 3. The groups cured by exponential curing showed the statistically lower polymerization shrinkage at 90s than the groups cured by conventional curing and soft start curing (p < 0.05). 4. The initial shrinkage ratios of soft start and exponential curing were statistically lower than conventional curing (p < 0.05). From this study, the use of low initial light intensities may reduce the polymerization rate and, as a result, reduce the stress of polymerization shrinkage.

Correlation between Linear polymerization shrinkage & tooth cuspal deflection (교두변위와 선수축량의 연관성 분석)

  • Lee, Soon-Young;Park, Sung-Ho
    • Restorative Dentistry and Endodontics
    • /
    • v.30 no.6
    • /
    • pp.442-449
    • /
    • 2005
  • The purpose of the present study was to evaluate the relationship between the amount of cuspal deflection and linear polymerization shrinkage in resin composite and polyacid modified resin composite, For cuspal defelction and shrinkage measurement, Dyract AP, Compoglass F, Z100, Surefil. Pyramid, Synergy Compact, Heliomolar and Heliomolar HB were used. For measuring polymerization shrinkage, a custom made linometer (R&B, Daejon, Korea) was used The amount of shrinkage among materials was compared using One-way ANOVA analysis and Tukey's test at the $95\%$ of confidence level For measuring cuspal deflection of teeth, standardized MOD cavities were prepared in extracted maxillary premolars. After a self-etching adhesive was applied, cavities were bulk filled with one of the felling materials. Fifteen teeth were used for each material. Cuspal deflection was measured by a custom made cuspal-deflection measuring device. One-way ANOVA analysis and Tukey's test were used to determine differences between the materials at the $95\%$ of confidence level, Correlation of polymerization shrinkage and cuspal deflection were analyzed by regression analysis. The amount of polymerization shrinkage from least to greatest was Heliomolar, Surefil < Heliomolar HB < Z100, Synergy Compact < Dyract AP < Pyramid, Compoglass F (p<0.05). The amount of cuspal deflection from least to greatest was Z100, Heliomolar, Heliomolar HB, Synergy Compact Surefil < Compoglass F < Pyramid, Dyract AP (p < 0.05). The amount of polymerization shrinkage and cuspal deflection showed a correlation (p<0.001).

THE AMOUNTS AND SPEED OF POLYMERIZATION SHRINKAGE AND MICROHARDNESS IN LED CURED COMPOSITES (LED를 이용한 복합레진의 광조사시, 중합수축의 속도와 양, 미세경도에 관한 연구)

  • Park, Sung-Ho;Kim, Su-Sun;Cho, Yong-Sik;Lee, Soon-Young;Kim, Do-Hyun;Jang, Yong-Joo;Mun, Hyun-Sung;Seo, Jung-Won;Noh, Byung-Duk
    • Restorative Dentistry and Endodontics
    • /
    • v.28 no.4
    • /
    • pp.354-359
    • /
    • 2003
  • This study evaluated the effectiveness of the light emitting diode(LED) units for composite curing. To compare its effectiveness with conventional quartz tungsten halogen (QTH) light curing unit. the microhardness of 2mm composite. Z250, which had been light cured by the LEDs (Ultralume LED2, FreeLight, Developing product Dl) or QTH (XL 3000) were compared on the upper and lower surface. One way ANOVA with Tukey and Paired t-test was used at 95% levels of confidence. In addition. the amount of linear polymerization shrinkage was compared between composites which were light cured by QTH or LEDs using a custom-made linometer in 10s and 60s of light curing, and the amount of linear polymerization shrinkage was compared by one way ANOVA with Tukey. The amount of polymerization shrinkage at 10s was XL3000 > Ultralume 2. 40. 60 > FreeLight, D1 (P<0.05) The amount of polymerization shrinkage at 60s was XL3000 > Ultralume 2, 60> Ultralume 2.40 > FreeLight, D1 (P<0.05) The microhardness on the upper and lower surface was as follows ; (equation omitted) It was concluded that the LEDs produced lower polymerization shrinkage in 10s and 60s compared with QTH unit. In addition. the microhardness of samples which had been cured with LEDs was lower on the lower surfaces than the upper surfaces whereas there was no difference in QTH cured samples.

The effect of cavity configuration on the mechanical properties of resin composites (중합환경에 따른 복합레진의 물리적 성질에 관한 연구)

  • Ryu, Gil-Joo;Park, Sang-Jin;Choi, Kyoung-Kyu
    • Restorative Dentistry and Endodontics
    • /
    • v.27 no.3
    • /
    • pp.239-248
    • /
    • 2002
  • 이 연구의 목적은 와동의 형태가 굴곡강도와 탄성계수 등 복합레진의 물리적 성질에 미치는 영향을 평가하는 것이다. 복합레진은 Clearfil$^{TM}$ AP-X(Kuraray, Japan)와 Esthet-X$^{TM}$(Dentsply, USA)가 이용되었으며, 상아질 접착제는 Clearfil$^{TM}$ SE Bond(Kuraray, Japan)와 Prime & Bond NT$^{TM}$(Dentsply, USA)를 사용하였다. 대조군의 시편은 split steel mold(25mm$\times$2mm$\times$2mm) 내에 상기 2종류의 복합레진을 충전하여 2개의 대조군 시편을 제작하였으며, 2.4 및 3.4의 C-factor를 부여하기 위한 유리 모형와동을 제작하고, 와동 내에 상기 2종류의 복합레진을 충전하기 전 유리와동의 내면은 sandblasting 처리하고 각각의 복합레진과 동일회사 제품의 상기 상아질 접착제로 처리한 후, 복합 레진을 각각 충전하여 4개의 실험군을 제작하였다. 제작된 실험군 시편은 저속 diamond saw로 충전된 복합레진 부위의 중심부를 통과하도록 절단하여 레진기둥(25mm$\times$2mm$\times$2mm)이 되도록 제작하였다. 제작된 시편을 37$^{\circ}C$의 증류수에 24시간 동안 보관 후, 만능시험기(EZ Test, Shimadzu, Japan)를 이용하여 분당 1mm의 crosshead speed로 3점 굴곡강도를 측정하였다. 또 Linometer(R&B, Korea)를 이용하여 복합레진의 중합수축량을 측정하였으며 굴곡강도측정 후 시편의 파단면은 주사전자현미경(S-2300, Hitachi, Japan)을 이용하여 관찰하였다. 실험결과의 통계분석은 95% 수준의 one-way ANOVA/Tukey's test를 이용하여 결과를 얻었다. 실험에 이용된 2종류 복합레진의 굴곡강도와 탄성계수는 C-factor치 증가에 따라 감소하였으며, 파단면 또한 C-factor의 증가에 따라 더 불규칙해지는 양상을 나타내었다. 본 실험의 결과 hybrid형 복합레진이 micro-hybrid형 복합레진에 비해 C-factor의 영향을 더 많이 받는 것으로 나타났으며, 와동의 C-factor증가가 굴곡강도나 탄성계수와 같은 복합레진의 물리적 성질을 저하시킨다는 것을 의미하였다.

The effect of resin thickness on polymerization characteristics of silorane-based composite resin

  • Son, Sung-Ae;Roh, Hyoung-Mee;Hur, Bock;Kwon, Yong-Hoon;Park, Jeong-Kil
    • Restorative Dentistry and Endodontics
    • /
    • v.39 no.4
    • /
    • pp.310-318
    • /
    • 2014
  • Objectives: This study examined the influence of the resin thickness on the polymerization of silorane- and methacrylate-based composites. Materials and Methods: One silorane-based (Filtek P90, 3M ESPE) and two methacrylate-based (Filtek Z250 and Z350, 3M ESPE) composite resins were used. The number of photons were detected using a photodiode detector at the different thicknesses (thickness, 1, 2 and 3 mm) specimens. The microhardness of the top and bottom surfaces was measured (n = 15) using a Vickers hardness with 200 gf load and 15 sec dwell time conditions. The degree of conversion (DC) of the specimens was determined using Fourier transform infrared spectroscopy (FTIR). Scratched powder of each top and bottom surface of the specimen dissolved in ethanol for transmission FTIR spectroscopy. The refractive index was measured using a Abbe-type refractometer. To measure the polymerization shrinkage, a linometer was used. The results were analyzed using two-way ANOVA and Tukey's test at p < 0.05 level. Results: The silorane-based resin composite showed the lowest filler content and light attenuation among the specimens. P90 showed the highest values in the DC and the lowest microhardness at all depth. In the polymerization shrinkage, P90 showed a significantly lower shrinkage than the rest two resin products (p < 0.05). P90 showed a significantly lower refractive index than the remaining two resin products (p < 0.05). Conclusions: DC, microhardness, polymerization rate and refractive index linearly decreased as specimen thickness linearly increased. P90 showed much less polymerization shrinkage compared to other specimens. P90, even though achieved the highest DC, showed the lowest microhardness and refractive index.

Comparison of the Mechanical Properties between Bulk-fill and Conventional Composites (Bulk-fill 복합레진과 전통적 복합레진의 물성비교)

  • Noh, Taehwan;Song, Eunju;Park, Soyoung;Pyo, Aeri;Kwon, Yonghoon;Kim, Jiyeon;Kim, Shin;Jeong, Taesung
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.43 no.4
    • /
    • pp.365-373
    • /
    • 2016
  • Composites are the most useful restorative material. However, composites have some disadvantages such as polymerization shrinkage, long working time, and susceptibility to water and contamination, which are stood out more especially when treating children. To solve these problems, bulk-fill composites have been developed. The aim of this study is to compare mechanical properties of bulk-fill and conventional composites. Bulk-fill composites (SureFil SDR flow (SDR), Tetric N-Ceram bulk fill (TBF)) and conventional composites (Filtek Z-350 (Z-350), Unifil Flow (UF), Unifil Loflo Plus (UL)) were used. The Vickers hardness tester was used to measure the microhardness of materials, and Fourier transform infrared spectroscopy was used to measure the degree of conversion. Polymerization shrinkage was measured by using a linometer. Flexural and compressive properties were measured by using the universal testing machine. Data were statistically analyzed by ANOVA and Scheffe's post hoc test. The level of significance was set to p < 0.05. Most conventional composites showed higher microhardness than bulk-fill composites. However, bulk-fill composites showed a higher top/bottom microhardness ratio than conventional composites. Bulk-fill composites showed a higher top/bottom degree of conversion ratio than conventional composites. The polymerization shrinkage was highest in UL and lowest in Z-350. The polymerization shrinkage of flowable composites was higher than that of non flowable composites. The compressive properties were highest in Z-350 and lowest in SDR and UL. In terms of flexural properties, Z-350 was the highest. However, none of the bulk-fill composites exhibited mechanical properties as good as those of conventional composites. Nonetheless, the ratio of microhardness and degree of conversion, which are important properties of bulk filling, were higher in bulk-fill composites. Therefore, the bulk-fill composites might be considered suitable restorative materials in pediatric dentistry.