• Title/Summary/Keyword: Lingual bracket

Search Result 32, Processing Time 0.023 seconds

A STUDY ON MORPHOLOGIC CHARACTERISTICS OF LINGUAL SURFACE OF CROWN AND LINGUAL ARCHFORM OF KOREAN ADULT WITH NORMAL OCCLUSION (정상교합자 설측치관형태 및 설측치열궁형태에 관한 연구)

  • Kim, Young-Lim;;Sung, Jae-Hyun
    • The korean journal of orthodontics
    • /
    • v.25 no.2 s.49
    • /
    • pp.209-221
    • /
    • 1995
  • The purpose of this study was to obtain the lingual morphology(angulation, inclination, horizontal and vertical contour) and lingual arch form of Korean adult with normal occlusion in order to provide the basic datas for lingual brackets and ideal lingual archwire. Dental models of thirty person with normal occlusion(Male : 16, Female :14) were selected for this study. Crown angulation, inclination. horizontal and vertical contour of lingual surfaces from Lt. 1st molar to Rt 1st molar of both upper and lower arch were measured. Lingual arcform was studied from copied papers of dental models attached Fujita lingual bracket. The results of this study were summarized as follows: 1. The average angulation and inclination of lingual surfaces of all tooth types for Korean adults with normal occlusion were obtained. 2. The average horizontal and vertical contour of lingual surfaces of all tooth types were obtained. 3. There were similar figures in horizontal and vertical contour of lingual surfaces between upper and lower molars, upper and lower premolars, upper and lower canines, upper central and lateral incisors and lower central and lateeral incisors respectively. It was possible that the use of those contour of bracket bases in common. 4. The average of lingual archform was provided, which was arch-shaped from canine to canine, linear along the premolars and molars with small offset bend between them, and where canines and premolars met, it was bent in a crank- shape. 3. There was no difference between lingual archform of male and that of female, although lingual archform of female was smaller than that of male in lower arch.

  • PDF

THREE-DIMENSIONAL FINITE ELEMENT ANALYSIS ON RECIPROCAL ACTION BY TORQUE APPLICATION IN MAXILLARY ARCHWIRE (상악호선에 torque 부여시 나타나는 상반작용에 관한 유한요소법적 연구)

  • Hwang, Chee-Il;Suhr, Cheong-Hoon
    • The korean journal of orthodontics
    • /
    • v.24 no.2
    • /
    • pp.479-508
    • /
    • 1994
  • This study was designed to investigate the reciprocal movement which was derived form application of active torque in ideal archwire by computer-aided three-dimensional finite element analysis of maxillary teeth and surrounding periodontal ligament composed of 2617 elements and 3725 nodes. Ideal archwire model was also made using the beam elements and the contact between the wire and the bracket slot was made using the gap element. In this study non-linear elastic behaviors of contact between the wire and the bracket slot were considered on. We put the active torque between the lateral and cenral incisor and between the second premolar and the first molar with/without cinch-back. The results were expressed by quantitative and visible ways. The findings of this study were as follows: 1. Reciprocal actions to active torque were complex system consisting of a combination of counter-torque, bucco-lingual linear displacement and tipping, rotation of the teeth, occluso-gingival linear displacement. 2. When active anterior crown labial torque was applied, crown labial tippings of the lateral were the greatest, and those of the central incisor was the next, Crown lingual tippings of the canine and the first premolar, mesial rotations and extrusion of the lateral and distal rotations and intrusion of the canine occurred. When anterior torque with the cinch-back was applied, amount of crown labial tippings of the lateral and central incisor were reduced. Amount of crown lingual tipping of the canine and the first premolar were increased. Mesial tippings and mesial rotations of the second molar occurred. 3. When active posterior crown lingual torque was applied, crown lingual tippings of the first moalr were the greatest, and crown labial tippings of the second premolar and the first premolar were the next, the crown lingual tipping of the second molar were a little. Mesial rotations of the second premolar occurred but those of the first premolar didn't occurred.

  • PDF

REPORT ON A CASE TREATED WITH LINGUAL MULTIBRACKET APPLIANCE

  • Kyung, Hee-Moon
    • The korean journal of orthodontics
    • /
    • v.26 no.6
    • /
    • pp.705-715
    • /
    • 1996
  • The lingual multibracket appliance was developed to overcome the unesthetic nature of traditional fixed orthodontic labial appliances; however, treatment with this appliance was regarded as very difficult as well as a time-consuming. Recently, these problems have been reduced because of advances in lingual bracket systems, improved indirect bonding technique and the development of more flexible wires. There has been a marked increase in the number of adults desiring orthodontic treatment over recent years and many of these patients tend to seek invisible orthodontic appliances due to esthetic reasons. Although the lingual multibracket treatment is not ideal, this form of treatment is currently the best option for the patients with esthetic concerns. Here, I would like to present a case treated successfully with lingual multibracket appliance.

  • PDF

A STATISTICAL STUDY OF CLINICAL CROWN INCLINATION IN KOREAN'S NATURALLY OCCURRING OPTIMAL OCCLUSION (한국인 정상교합자의 치관경사도에 관한 임상통계학적 연구)

  • Kim, Jong-Sung;Jin, Keun-Ho;Hong, Sung-Joon
    • The korean journal of orthodontics
    • /
    • v.22 no.3 s.38
    • /
    • pp.715-733
    • /
    • 1992
  • The objective of this study was to evaluate some clinical aspect of the crown inclination in Korean's naturally occuring optimal occlusion, and to statistically compare the crown inclination at Andrews' FA points group and another bracket slot level group based on marginal ridges. The materials consisted of study models of 30 patients (14; Korean's males, 16; Korean's females) who have nonorthodontic normal occlusion. The results were as follows; 1. Mean, standard deviation, range of clinical inclination in the Andrews' FA points and another bracket slot level were obtained. 2. Statistically difference between Andrews' FA points group and bracket slot level group based on marginal ridge was non significant (p > 0.05). But standard deviation and range in FA points group was more stability than marginal ridge group. 3. A lingual crown inclination at FA points in the upper posterior teeth existed (canines through molars). 4. The lingual crown inclination at FA points in the lower dentition progressively increased from the incisors through the second molars.

  • PDF

A MORPHOLOGIC CHARACTERISTICS STUDY OF CROWN OF LINGUAL SURFACE WITH NORMAL OCCLUSION IN KOREAN ADULTS (한국인 성인 정상교합자 치관의 설측면 특징에 관한 연구)

  • Yu, Hyung-Seog;Park, Young-Chel
    • The korean journal of orthodontics
    • /
    • v.22 no.3 s.38
    • /
    • pp.675-690
    • /
    • 1992
  • The purpose of this study was to obtain the lingual morphology (size, angulation, contour, eminence) of adults with normal occlusion in order to provide the basic data for lingual bracket and lingual arch form in Korean. The subjects (Male: 50, Female: 50) were selected who have normal occlusion and dental casts were prepared. Tooth size, angulation, arch width, horizontal contour, lingual eminence were measured for all 28 teeth both upper and lower arch. The results were as follows: 1. Measuring items of all individual teeth for adults with normal occlusion were obtained. 2. In comparison tests, there was a statistically difference between intermolar widths $(\underline{6}\;to\;\underline{6})$ before occlusal reduction and intermolar width $(\underline{6}\;to\;\underline{6},\underline{7}\;to\;\underline{7})$ after occlusal reduction only all the other measuring items showed no statistically differences. 3. There was small variation in horizontal contour of lingual surface on lower incisors and upper and lower bicuspids. The other teeth showed somewhat greater variations. 4. There was offset between canine and bicuspid in upper arch while there was no prominent offset in lower arch.

  • PDF

Three-dimensional evaluation of the transfer accuracy of a bracket jig fabricated using computer-aided design and manufacturing to the anterior dentition: An in vitro study

  • Park, Jae-Hyun;Choi, Jin-Young;Kim, Seong-Hun;Kim, Su-Jung;Lee, Kee-Joon;Nelson, Gerald
    • The korean journal of orthodontics
    • /
    • v.51 no.6
    • /
    • pp.375-386
    • /
    • 2021
  • Objective: To evaluate the accuracy of a one-piece bracket jig system fabricated using computer-aided design and manufacturing (CAD/CAM) by employing three-dimensional (3D) digital superimposition. Methods: This in vitro study included 226 anterior teeth selected from 20 patients undergoing orthodontic treatment. Bracket position errors from each of the 40 arches were analyzed quantitatively via 3D digital superimposition (best-fit algorithm) of the virtual bracket and actual bracket after indirect bonding, after accounting for possible variables that may affect accuracy, such as crowding and presence of the resin base. Results: The device could transfer the bracket accurately to the desired position of the patient's dentition within a clinically acceptable range of ± 0.05 mm and 2.0° for linear and angular measurements, respectively. The average linear measurements ranged from 0.029 to 0.101 mm. Among the angular measurements, rotation values showed the least deviation and ranged from 0.396° to 0.623°. Directional bias was pronounced in the vertical direction, and many brackets were bonded toward the occlusal surface. However, no statistical difference was found for the three angular measurement values (torque, angulation, and rotation) in any of the groups classified according to crowding. When the teeth were moderately crowded, the mesio-distal, bucco-lingual, and rotation measurement values were affected by the presence of the resin base. Conclusions: The characteristics of the CAD/CAM one-piece jig system were demonstrated according to the influencing factors, and the transfer accuracy was verified to be within a clinically acceptable level for the indirect bracket bonding of anterior teeth.