• Title/Summary/Keyword: Linear program

Search Result 1,607, Processing Time 0.031 seconds

Developement of Measuring Units of circular Motion Accuracy on NC Lathe (NC선반의 원 운동정도 측정장치의 개발)

  • 김영석;김재열
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.10 no.6
    • /
    • pp.1-7
    • /
    • 2001
  • It is very important to test circular motion accuracy of NC machine tools as it affects all other machines machined by them in industries. In this paper, it has become possible to detect errors of linear displacement of radial directions for circle tar motion accuracy test using newly assembled magnetic type of linear scale so called Magnescale ball-bar system. It has also organized computer program systems using tick pulses come out from computer for getting error motion data at colt start time interval in circular motion test on NC lathe. Error data gotten from test is expressed to plots and analysed to numerics by various statistical treatments.

  • PDF

Development of the Dynamic Simulation Program for the Multi-Inverter Heat Pump Air-Conditioner (멀티 인버터 히트펌프의 동특성 해석 프로그램의 개발)

  • ;;小山繁
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.11
    • /
    • pp.1079-1088
    • /
    • 2001
  • A dynamic simulation model was developed to analyse the transient characteristics of a multi-inverter heat pump. The programs included a basic air conditioning system such as a evaporator, condenser, compressor, linear electronic expansion valve (LEV) and by-pass circuit. The theoretical model was derived from mass conservation and energy conservation equations to predict the performance of the multi-inverter heat pump at various operating conditions. Calculated results were compared with the values obtained from the experiments at different operation frequencies of compressor, area of the LEV and configuration of indoor units operation. The results of the simulation model showed a good agreement with the experimental ones, so that the model could be used as an efficient tool for thermodynamic design and control factor design of air-conditioners.

  • PDF

Analyses of Non-linear Behavior of Axisymmetric Structure by Finite Element Method (유한요소법을 이용한 축대칭 구조물의 비선형 거동해석)

  • 구영덕;민경탁
    • Computational Structural Engineering
    • /
    • v.10 no.2
    • /
    • pp.139-148
    • /
    • 1997
  • A finite element method is programmed to analyse the nonlinear behavior of axisymmetric structures. The lst order Mindlin shell theory which takes into account the transversal shear deformation is used to formulate a conical two node element with six degrees of freedom. To evade the shear locking phenomenon which arises in Mindlin type element when the effect of shear deformation tends to zero, the reduced integration of one point Gauss Quadrature at the center of element is employed. This method is the Updated Lagrangian formulation which refers the variables to the state of the most recent iteration. The solution is searched by Newton-Raphson iteration method. The tangent matrix of this method is obtained by a finite difference method by perturbating the degrees of freedom with small values. For the moment this program is limited to the analyses of non-linear elastic problems. For structures which could have elastic stability problem, the calculation is controled by displacement.

  • PDF

A Study on the Nonlinear Dynamics of PR Interval Variability Using Surrogate data

  • Lee, J.M.;Park, K.S.;Shin, I.S.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1996 no.05
    • /
    • pp.27-30
    • /
    • 1996
  • PR interval variability has been proposed as a noninvasive tool for in-vestigating the autonomic nervous system as welt as heart rate variability. The goal of this paper is to determine whether PR interval variability is generated from deterministic nonlinear dynamics. The data used in this study is a 24-hour bolter ECGs of 20 healthy adults. We developed an automatic PR interval measurement algorithm, and tested it using MIT ECG Databases. The general discriminants of nonlinear dynamics, such as, correlation dimension and phase space reconstruction are used. Surrogate data is generated from simpler linear models to have similar statistical characteristics with the original data. Nonlinear discriminants are applied to both data, and compared for any significant results. It was concluded that PR interval variability shows non-linear characteristics.

  • PDF

Research and Development of a Geological Remote Sensing Information Extraction System

  • Zhengmin, He
    • Proceedings of the KSRS Conference
    • /
    • 2003.11a
    • /
    • pp.1442-1444
    • /
    • 2003
  • This paper presents a geological remote sensing information extraction system, the aim of which is to provide practical models and powerful tools to extract geological information from remote sensing images for geological exploration applications. After reviewing and analyzing the existing methods for geological information extraction, we developed more than ten models to enhance and extract geological information, such as alteration information, linear features and special lithological characters. The system is developed based on Erdas Imagine using its programming language. It has been successfully used in the ‘Great Investigation of Land and Natural Resources of China’ program.

  • PDF

Linearization Method and Vibration Analysis of a Constrained Multibody System Driven by Constant Generalized Speeds (일정 일반속력으로 구동되는 구속 다물체계의 선형화기법 및 진동해석)

  • 최동환;박정훈;유홍희
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2001.11b
    • /
    • pp.725-730
    • /
    • 2001
  • This paper presents a vibration analysis method for constrained mechanical systems driven by constant generalized speeds. Equilibrium positions are obtained first and vibration analysis are performed around the positions. The method developed in this paper employs partial velocity matrix to obtain a minimum number of differential equations. To verify the accuracy of the proposed algorithm, linear vibration analyses of two numerical examples are performed and the results are compared with results from a commercial program or previous literature.

  • PDF

Development of Simulation Program for Multi-Air conditioner (멀티에어컨의 성능해석 프로그램 개발)

  • Jeong, B.Y.;Koh, J.Y.;Park, B.D.;Yim, C.S.
    • Solar Energy
    • /
    • v.20 no.1
    • /
    • pp.63-72
    • /
    • 2000
  • In this study, theoretical simulation method for the steady state characteristics of a refrigeration cycle which consists of one condenser and multi-evaporator (Multi-air conditioner) is presented. The simulation was performed for a typical multi-air conditioning system consisted one outdoor unit with air-cooled condenser, compressor, linear electric expansion valve and bypass circuit and connected three-evaporators (three indoor units). The simulation results are good agreement with those of experiments within 5 $\sim$ 10% at the given system operation conditions which are condensing pressure, evaporating pressure, sub-cooled degree of condenser, superheated degree, discharge temperature of compressor and pulse of linear electric expansion valve.

  • PDF

A Study on the Automatic Placement System for Standard Cell (스텐다드 셀의 자동배치 시스템에 관한 연구)

  • Kang, Gil Soon;Kyung, Chong Min;Park, Song Bai
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.23 no.4
    • /
    • pp.557-564
    • /
    • 1986
  • This paper describes a standard cell placement strategy which consists of three kconsecutive steps` initial placement, iterative placement improvement, and string placement. In the initial placement step, cell placement was done by solving the linear ordering problem for a one-dimensional layout of standard cells and then zigzaging the resultant linear order width in the chip plane. The iterative placement improvement step is based on the iterative pairwise interchange using the estimated total routing length as a figure-or -merit. The string placement is used to reorder cells and terminals in each etandard cell row such that channel routing in the adjacent channels is not blocked by cyclic constraints and needs fewer routing tracks. The placement program is coded in PASCAL and kimplemented on a VAX-11/750 computer. Experimental results for several examples are included.

  • PDF

Transitional Vibration Characteristics of Single Degree of Freedom System through the Resonance (공진을 통과하는 일자유도계의 과도진동 특성)

  • Chung, Tae-Jin;Hong, Dong-Pyo;Tae, Sin-Ho
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.10 no.3
    • /
    • pp.41-46
    • /
    • 1993
  • The transitional characterisics of oscillations and rotational speeds from the starting to the stationary states in damped single degree of freedom systems acted upon the rotor unbalance forces are studied. Angular travel is assumed to vary with time. The theoretical analysis is obtained by using Laplace transform method. Integration involved in the theoretical results is carried out by the numerical analysis program of continuous-time linear systems to arbitrary inputs. It is evident that the transitional charcterixtics of a machine are affected remarkably by damping ratios, stationary angular velocity time and frequency ratios.

  • PDF

Effects of Settings in Dynamic Ranges and Frequency Modes on Ultrasonic Images (초음파 영상에서 동적영역과 주파수 방식의 설정에 따른 효과)

  • Yang, Jeong-Hwa;Kang, Gwan-Suk;Lee, Kyung-Sung;Paeng, Dong-Guk;Choi, Min-Joo
    • Journal of radiological science and technology
    • /
    • v.32 no.3
    • /
    • pp.277-283
    • /
    • 2009
  • It is important to get clinical ultrasonic images of good quality for accurate diagnosis. In this study, it observed the change of ultrasonic images against setting frequency, dynamic range(DR) and type of probes on ultrasonic scanner. In the experiment it evaluated image of LCS (Low Contrast Sensitivity) targets(-15, -6, -3, +3, +6, +15 dB) of a standard ultrasonic test phantoms(539,551, ATS, USA) similar to solid and cystic lesions. Its imaged from convex (C3-7IM) and linear probe (L5-12IM) on SA-9900 (Medison Ltd, Korea) scanner. The images obtained altering the setting parameters which are frequency(gen, pen, res, harmonic) mode and DR($40{\sim}100\;dB$). The quality of images evaluated compare with the nominal LCS value of target and measured LCS value. The results show that there was no significant changing of quality images altering DR 40, 60, 80, 100 dB against frequency in Convex probe but the image being the highest in LCS target at DR 60 dB, harmonic of frequency mode in the -15 dB target close to cystic lesion. In Linear probe, DR 40 dB, harmonic mode at -15 dB LCS target close to nominal value. It discussed necessity of evaluation about ROC(Receiver Operating Characteristic) from the psychological viewpoint and limit of evaluation from quantified images.

  • PDF