• Title/Summary/Keyword: Linear intensity calibration

Search Result 37, Processing Time 0.033 seconds

The identification of Raman spectra by using linear intensity calibration (선형 강도 교정을 이용한 라만 스펙트럼 인식)

  • Park, Jun-Kyu;Baek, Sung-June;Park, Aaron
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.3
    • /
    • pp.32-39
    • /
    • 2018
  • Raman spectra exhibit differences in intensity depending on the measuring equipment and environmental conditions even for the same material. This restricts the pattern recognition approach of Raman spectroscopy and is an issue that must be solved for the sake of its practical application, so as to enable the reusability of the Raman database and interoperability between Raman devices. To this end, previous studies assumed the existence of a transfer function between the measurement devices to obtain a direct spectral correction. However, this method cannot cope with other conditions that cause various intensity distortions. Therefore, we propose a classification method using linear intensity calibration which can deal with various measurement conditions more flexibly. In order to evaluate the performance of the proposed method, a Raman library containing 14033 chemical substances was used for identification. Ten kinds of chemical Raman spectra measured using three different Raman spectroscopes were used as the experimental data. The experimental results show that the proposed method achieves 100% discrimination performance against the intensity-distorted spectra and shows a high correlation score for the identified material, thus making it a useful tool for the identification of chemical substances.

Measurement of GMAW Bead Geometry Using Biprism Stereo Vision Sensor (바이프리즘 스테레오 시각 센서를 이용한 GMA 용접 비드의 3차원 형상 측정)

  • 이지혜;이두현;유중돈
    • Journal of Welding and Joining
    • /
    • v.19 no.2
    • /
    • pp.200-207
    • /
    • 2001
  • Three-diemnsional bead profile was measured using the biprism stereo vision sensor in GMAW, which consists of an optical filter, biprism and CCD camera. Since single CCD camera is used, this system has various advantages over the conventional stereo vision system using two cameras such as finding the corresponding points along the horizontal scanline. In this wort, the biprism stereo vision sensor was designed for the GMAW, and the linear calibration method was proposed to determine the prism and camera parameters. Image processing techniques were employed to find the corresponding point along the pool boundary. The ism-intensity contour corresponding to the pool boundary was found in the pixel order and the filter-based matching algorithm was used to refine the corresponding points in the subpixel order. Predicted bead dimensions were in broad agreements with the measured results under the conditions of spray mode and humping bead.

  • PDF

Determination of Horseradish Peroxidase (HRP) using an Enhanced Chemiluminescence Assay (증강 화학발광 기법을 이용한 horseradish peroxidase(HRP)의 검량)

  • Kim, Wongee;Kim, Keunhan;Lee, Seungmok
    • Journal of Korean Society on Water Environment
    • /
    • v.25 no.1
    • /
    • pp.84-89
    • /
    • 2009
  • Our nation's water resources remain susceptible to contamination by phenolic agrichemicals. These compounds can be toxic to a variety of organisms including humans. Their disposal is restricted in many countries with strict limits for acceptable concentrations in drinking water. Enzyme-mediated in situ stabilization has been advocated as an approach for the treatment of phenolic compounds in soils and groundwater. This study reports the development of a new approach to quantify the activity of the HRP enzyme in aqueous systems. The method is based on the coupled processes of energy transfer and enhanced chemiluminescence using a luminol-$H_2O_2$-HRP system. In this study, the effects of solution pH, ionic strength and aqueous concentrations of HRP, $H_2O_2$ and enhancer were evaluated on the p-iodophenol-enhanced, HRP-catalyzed chemiluminescence reaction intensity in Tris-HCl buffer. All assay components were found to affect the maximum chemiluminescene intensity. The calibration curve for HRP showed the linear relationship with maximum light intensity.

Measurement of Stress Intensity Factor of Orthotropic Material Using SPATE (SPATE에 의한 직교이방성체의 응력확대계수 측정)

  • Hwang, Jae-Seok;Suh, Jae-Guk;Lee, Hyo-Jae;Nam, Jeong-Hwan;Rpwlands, R.E.
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.20 no.10
    • /
    • pp.3224-3233
    • /
    • 1996
  • SPATE(Stress Pattern Analysis by Thermal Emission) can be effectively used to analyze the stress distribution of the orthotropic structure under the repeated load by non-contact. In this research, the measuring conception and method of stress intensity factor of orthotropic material using SPATE are suggested. The relationships between the maximum values of SPATE signal and $1/\sqrt{X'}$ (or $1/\sqrt{y'}$) are theoretically established in the vicinity of crack tip of the orthotropic material. It is certified through SPATE experiment that their linear quality is very excellent.

Optical Multi-Channel Intensity Interferometry - or: How To Resolve O-Stars in the Magellanic Clouds

  • Trippe, Sascha;Kim, Jae-Young;Lee, Bangwon;Choi, Changsu;Oh, Junghwan;Lee, Taeseok;Yoon, Sung-Chul;Im, Myungshin;Park, Yong-Sun
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.39 no.2
    • /
    • pp.111-111
    • /
    • 2014
  • Intensity interferometry, based on the Hanbury Brown--Twiss effect, is a simple and inexpensive method for optical interferometry at microarcsecond angular resolutions. Motivated by recent technical developments, we argue that the sensitivity of large modern intensity interferometers can be improved by factors up to approximately 25,000, corresponding to 11 photometric magnitudes, compared to the pioneering Narrabri Stellar Interferometer of the 1970s when resolving. Our approach, based on spectrally resolved light, permits the construction of large optical interferometers at the cost of (very) long-baseline radio interferometers. Realistic intensity interferometers are able to spatially resolve main-sequence O-type stars in the Magellanic Clouds. Multi-channel intensity interferometers can address a wide variety of science cases: (i) linear radii, effective temperatures, and luminosities of stars; (ii) mass-radius relationships of compact stellar remnants; (iii) stellar rotation; (iv) stellar convection and the interaction of stellar photospheres and magnetic fields; (v) the structure and evolution of multiple stars; (vi) direct measurements of interstellar distances; (vii) the physics of gas accretion onto supermassive black holes; and (viii) calibration of amplitude interferometers by providing a sample of calibrator stars.

  • PDF

Determination of As(V) ion by Chemiluminescence Method

  • Lee, Sang-Hak;Jeon, Hyun-Sook
    • Proceedings of the Korean Environmental Sciences Society Conference
    • /
    • 2003.11a
    • /
    • pp.109-112
    • /
    • 2003
  • A method to determine As(V) ions in aqueous solution by chemiluminescence method has been studied using a stopped flow system. The method is based on the increased chemiluminescence intensity with the addition of As(V) ion to a solution of lucigenin and hydrogen peroxide. The effects of KOH concentration, $H_2O_2$ concentration and flow rate of reagents on the chemiluminescence intensity have been investigated. The calibration curve for As(V) was linear over the range from $1.0{\times}l0^{-6}$M to $1.0{\times}l0^{-4}$M, the coefficient of correlation was 0.997 and the detection limit was $3.3{\times}l0^{-7}$M under the optimal experimental conditions.

  • PDF

APPLICATION STUDY OF CHEMOINFOMETRICAL NEAR-INFRARED SPECTROSCOPY IN PHARMACEUTICAL INDUSTRY

  • Otsuka, Makoto;Kato, Fumie;Matsuda, Yoshihisa
    • Proceedings of the Korean Society of Near Infrared Spectroscopy Conference
    • /
    • 2001.06a
    • /
    • pp.2111-2111
    • /
    • 2001
  • A chemoinfometrical method for evaluating the quantitative determination of crystallinity one polymorphs based on fourie-transformed near-infrared (FT-NIR) spectroscopy was established. A direct comparison of the data with the ones collected from using the and compared with the conventional powder X-ray diffraction method was performed. [Method] The pPure a and g forms of indomethacin (IMC) were prepared by reportedusing published methods. Six kinds of standard samples obtained by physically mixing of a and g forms. After the powder X-ray diffraction profiles of samples have been measured, the intensity values were normalized to against the intensity of silicon powder as the as an external standard. The calibration curves for quantification of crystal content were based upon the total relative intensity of four diffraction peaks from of the form g crystal. FT-NIR spectra of six calibration sample sets were recorded 5 times with the NIR spectrometer (BRAN+LUEBBE). Chemoinfometric analysis was performed on the NIR spectral data sets by applying the principal component regression (PCR). [Results] The relation between the actual and predicted polymorphic contents of form g IMC measured using by the X-ray diffraction method shows a good straight linen linear relation., and it has slope of 0.023, an intercept of 0.131 and a correlation coefficient of 0.986. PCR analyses wereis was performed based on normalized NIR spectra sets offer standard samples of known content of IMC g form. IMC. A calibration equation was determined to minimize the root mean square error of the predictionthe prediction. Figure 1 shows a plot of the calibration data obtained by NIR method between the actual and predicted contents of form g IMC. The predicted values were reproducible and had a smaller standard deviation. Figure 2 shows that the plot for the predicted transformation rate (%) of form a IMC to form g as measured by X-ray diffractomeoy against to those as measured by NIR method. The plot has a slope of 1.296, an intercept of 1,109, and a correlation coefficient of 0.992. The line represents a satisfactory correlation between the two predicted values of form g IMC content. Thus NIR spectroscopy is an effective method for the evaluation to the pharmaceutical products of quantitative of polymorph.

  • PDF

Continuous Blood Pressure Prediction Using PTT During Exercise (PTT를 이용한 자전거 운동 중 지속적인 혈압의 예측)

  • Kim, Chul-Seung;Moon, Ki-Wook;Kwon, Jung-Hoon;Eom, Gwang-Moon
    • Journal of Biomedical Engineering Research
    • /
    • v.27 no.6
    • /
    • pp.370-375
    • /
    • 2006
  • The purpose of this work is to predict the systolic blood pressure (BP) during exercise from pulse transit time (PTT) for warning of possible danger. PTT was calculated as the time between R-peak of ECG and the peak of differential photoplethysmograph (PPG). For the PTT-BP model, we used regress equations from previous studies and 3 kinds of new models combining linear and nonlinear regress equation. The model parameters were estimated with the data measured under low to middle intensity exercise, and then was tested with the data measured under high intensity exercise. Predicted BP values after high intensity exercise were compared with those measured by cuff-type sphygmomanometer. The results showed that the error between measured and predicted values were acceptable for the monitoring BP. We tested PTT-BP models 1 month after the identification without further calibration. Models could predict the BP and the errors between measured and predicted BP were about 5mmHg. The suggested system is expected to be helpful in recognizing any danger during exercise.

CHALLENGING APPLICATIONS FOR FT-NIR SPECTROSCOPY

  • Goode, Jon G.;Londhe, Sameer;Dejesus, Steve;Wang, Qian
    • Proceedings of the Korean Society of Near Infrared Spectroscopy Conference
    • /
    • 2001.06a
    • /
    • pp.4112-4112
    • /
    • 2001
  • The feasibility of NIR spectroscopy as a quick and nondestructive method for quality control of uniformity of coating thickness of pharmaceutical tablets was investigated. Near infrared spectra of a set of pharmaceutical tablets with varying coating thickness were measured with a diffuse reflectance fiber optic probe connected to a Broker IFS 28/N FT-NIR spectrometer. The challenging issues encountered in this study included: 1. The similarity of the formulation of the core and coating materials, 2. The lack of sufficient calibration samples and 3. The non-linear relationship between the NIR spectral intensity and coating: thickness. A peak at 7184 $cm^{-1}$ was identified that differed for the coating material and the core material when M spectra were collected at 2 $cm^{-1}$ resolution (0.4 nm at 7184 $cm^{-1}$). The study showed that the coating thickness can be analyzed by polynomial fitting of the peak area of the selected peak, while least squares calibration of the same data failed due to the lack of availability of sufficient calibration samples. Samples of coal powder and solid pieces of coal were analyzed by FT-NIR diffuse reflectance spectroscopy with the goal of predicting their ash content, percentage of volatile components, and energy content. The measurements were performed on a Broker Vector 22N spectrometer with a fiber optic probe. A partial least squares model was constructed for each of the parameters of interest for solid and powdered sample forms separately. Calibration models varied in size from 4 to 10 PLS ranks. Correlation coefficients for these models ranged from 86.6 to 95.0%, with root-mean-square errors of cross validation comparable to the corresponding reference measurement methods. The use of FT-NIR diffuse reflectance measurement techniques was found to be a significant improvement over existing measurement methodologies in terms of speed and ease of use, while maintaining the desired accuracy for all parameters and sample forms.(Figure Omitted).

  • PDF

Estimation of Moisture Content in Comminuted Miscanthus based on the Intensity of Reflected Light

  • Cho, Yongjin;Lee, Dong Hoon
    • Journal of Biosystems Engineering
    • /
    • v.40 no.3
    • /
    • pp.296-304
    • /
    • 2015
  • Purpose: The balance between miscanthus production and its cost effectiveness depends greatly on its moisture content during post processing. The objective of this research was to measure the moisture content using a non-destructive and non-contact methodology for in situ applications. Methods: The moisture content of comminuted miscanthus was controlled using a closed chamber, a humidifier, a precision weigher, and a real-time monitoring software developed in this research. A CMOS sensor equipped with $50{\times}$ magnifier lens was used to capture magnified images of the conditioned materials with moisture content level from 5 to 30%. The hypothesis is that when light is incident on the comminuted particles in an inclined manner, higher moisture content results in light being reflected with a higher intensity. Results: A linear regression analysis for an initiative hypothesis based on general histogram analysis yielded insufficient correlations with low significance level (<0.31) for the determination coefficient. A significant relationship (94% confidence level) was determined at level 108 in a reverse accumulative histogram proposed based on a revised hypothesis. A linear regression model with the value at level 108 in the reverse accumulative histogram for a magnified image as the independent variable and the moisture content of comminuted miscanthus as the dependent variable was proposed as the estimation model. The calibrated linear regression model with a slope of 92.054 and an offset of 32.752 yielded 0.94 for the determination coefficient (RMSE = 0.2%). The validation test showed a significant relationship at the 74% confidence level with RMSE 6.4% (n = 36). Conclusions: To compensate the inconsistent significance between calibration and validation, an estimation model robust against various systematic interferences is necessary. The economic efficiency of miscanthus, which is a promising energy resource, can be improved by the real-time measurement of its crucial material properties.