• 제목/요약/키워드: Linear induced generator

검색결과 14건 처리시간 0.024초

수소연소 선형 발전기의 이동자 위치 검출 (Mover position detection for Hydrogen Fueled linear generator)

  • 김신아;정승기
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2011년도 추계학술대회
    • /
    • pp.279-280
    • /
    • 2011
  • In order to convert the mechanical movement of a linear generator to electrical power, the amateur current of the generator is controlled in accordance to the mover position. A linear encoder, usually used for direct detection of the mover position, not only is vulnerable to mechanical vibration, but also imposes significant constraint on the mechanical design of the generator system. Thus, this study proposes a method for indirect estimation of the mover position with emfs induced in amateur coils. The estimation algorithm is validated with simulation study.

  • PDF

Detent Force Reduction of a Tubular Linear Generator Using an Axial Stepped Permanent Magnet Structure

  • Eid Ahmad M.;Lee Hyun-Woo;Nakaoka Mutsuo
    • Journal of Power Electronics
    • /
    • 제6권4호
    • /
    • pp.290-297
    • /
    • 2006
  • Various methods have been discussed to reduce detent force in a tubular permanent magnet type linear single phase AC generator. In particular, the proposed methods depend on variations of the permanent magnet construction. These methods include two approaches in the form of sloped magnets, and conical magnets in addition to the conventional method of optimizing the magnet length. The undesired detent force ripples were calculated by a two dimensional Finite Element Method (FEM). Moreover, the generated electromotive force in the stator coils was calculated for each configuration of the permanent magnet. The experimental results agreed well with those obtained from the FEM-based simulations. Sufficient reduction in the detent force was achieved over the range of 40% while the root mean square of the output voltage was maintained. It was found that sloping the permanent magnet decreased the detent force and at the same time increased the generated rms voltage of the AC generator. The performance of the designed linear AC generator was evaluated in terms of its efficiency, total weight, losses, and power to weight ratio.

해석적 방법을 이용한 양측식 선형 영구자석 발전기의 특성해석 (Characteristic Analysis of Double sided Permanent Magnet Linear Generator by using Analytical Method)

  • 강한빛;최장영;김경환;홍기용
    • 전기학회논문지
    • /
    • 제63권5호
    • /
    • pp.652-659
    • /
    • 2014
  • This paper deals with characteristic analysis of double sided permanent magnet linear generator using analytical method. We derived magnetic field solutions produced by permanent magnet and armature reaction based on the 2D polar coordinate and magnetic vector potential. based on the derived magnetic field solutions, Induced voltage is obtained when arbitrary sinusoidal input condition. In addition, electrical parameters such as back-EMF constant, resistance, and inductance are obtained. Finally, generating performance characteristic at the rated load and various load is examined by using equivalent circuit.

해석적 방법을 이용한 슬롯리스 양측식 코어드 타입 영구자석 발전기의 와전류 손실 해석 (Eddy Current Loss Analysis of Slotless Double-sided Cored Type Permanent Magnet Generator by using Analytical Method)

  • 장강현;정경훈;홍기용;김경환;최장영
    • 전기학회논문지
    • /
    • 제65권10호
    • /
    • pp.1639-1647
    • /
    • 2016
  • This paper deals with eddy current loss analysis of Slotless Double sided Cored type permanent magnet linear generator by using analytical method, space harmonic method. In order to calculate eddy current, this paper derives analytical solution by the Maxwell equation, magnetic vector potential, Faraday's law and a two-dimensional(2-D) cartesian coordinate system. First, we derived the armature reaction field distribution produced by armature wingding current. Second, by using derived armature reaction field solution, the analytical solution for eddy current density distribution are also obtained. Finally, the analytical solution for eddy current loss induced in permanent magnets(PMs) are derived by using equivalent, electrical resistance calculated from PMs volume and eddy current density distribution solution. The analytical result from space harmonic method are validated extensively by comparing with finite element method(FEM).

공간고조파법을 이용한 영구자석 선형 발전기의 특성 해석 (Characteristic Analysis of Permanent Magnet Linear Generator by using Space Harmonic Method)

  • 서성원;최장영;김일중
    • 한국산학기술학회논문지
    • /
    • 제18권1호
    • /
    • pp.688-695
    • /
    • 2017
  • 본 논문은 파력 에너지 수집 장치에 사용할 수 있는 영구자석 선형 동기발전기의 특성 해석에 관한 것이다. 파력 에너지는 요요시스템과 같은 기구로 부터 얻어진다. 영구자석을 이용한 선형 발전기는 영구자석의 자력을 통해 별도의 전원공급이 필요 없고 유지 보수가 간단한 장점을 가지고 있다. 또한 높은 에너지 밀도를 갖는 희토류의 사용으로 영구자석 기기는 소형화 및 경량화가 가능하며 보다 높은 에너지 변환 효율을 얻을 수 있다. 영구자석 선형 동기발전기 특성 해석을 위해 2차원 극 좌표계 및 자기 벡터 포텐셜에 근거하여 영구자석과 전기자 반작용 자계해석을 수행 하였다. 해석 해를 이용하여 정현적인 속도입력에 의해 유도되는 유기기전력의 특성 식을 유도하고, 동일한 방법으로 역기전력 상수, 저항, 자기인덕턴스와 상호인덕턴스와 같은 전기적 파라미터를 얻었다. 본 논문에서 사용한 공간고조파법의 결과는 2차원 유한요소해석법 결과와 비교하여 잘 일치하는 것을 확인하였다. 이 결과는 영구자석 형 선형 발전기의 특성을 이해하는 것과 해석방법의 비교연구, 설계 최적화, 그리고 기기의 동적 모델링에 기여할 수 있다.

증기발생기 전열관 충격 미끄럼 마모 모델 개발 (Development of Impact-sliding wear model for Steam Generator Tubes)

  • 권대엽;신희재;오영진;반치범
    • 한국압력기기공학회 논문집
    • /
    • 제19권2호
    • /
    • pp.61-68
    • /
    • 2023
  • The phenomenon of fretting wear due to the flow-induced vibration in steam generator (SG) tube is a significant degradation mechanism in nuclear power plants. Fretting wear in SG tube is primarily attributed to the friction and impact forces between the SG tube and the tube support structures, experienced during nuclear power plants operation. While the Archard model has generally been used for the prediction of fretting wear in SG tube, it is limited by its linear nature. In this study, we introduced an "Impact Shear Work-rate" (ISW) model, which takes into account the combined effects of impact and sliding. The ISW model was evaluated using existing experimental data on fretting wear in SG tube and was compared against the Archard model. The prediction results using the ISW model were more accurate than those using the Archard model, particularly for impact forces.

DFIG 풍력발전기가 연계된 배전선로의 고조파 공진 특성에 관한 연구 (A Study on Harmonic Resonance in a DFIG Wind Turbine-generator Connected to a Distribution Power Line)

  • 최형주;이흥호
    • 전기학회논문지
    • /
    • 제62권10호
    • /
    • pp.1383-1389
    • /
    • 2013
  • There were telecommunication noise and malfunctions of the electronic devices occurred over a wide area due to the high harmonic voltage and/or current levels of the Back-to-back converter in the DFIG wind power system even though the magnitude of all harmonics is within the international standards. The triangular carrier signals of the PWM used in the power converter system is related to the telecommunication noise because they are in the range of audible frequencies and amplified by a variety of the standing waves that were excited by harmonic voltage sources in the weak grid system such as a long distance distribution transmission lines. This paper describes the characteristics of the harmonics in the wind turbine-generator, numerical analysis and simulation of the harmonics resonance phenomena in the distribution lines as well as measuring induced voltage of the telecommunication lines in parallel with power lines in order to verify the root cause of the telecommunication noise. These noise problems can occur in a wind turbine power system with a non-linear converter at any time, as well as photovoltaic power system. So, the preliminary review of suitable filter devices and switching frequencies of the PWM have to be required by considering the stability of the controller at the design stage but as part of the measures the effect of the telecommunication cable shields was analyzed by comparing the measured data between multi-conductor with/without shields so as to attenuate the sources of the harmonics voltage induced into the telecommunication lines and to apply the most cost-effective measures in the field.

Reactive oxygen species increase neuronal excitability via activation of nonspecific cation channel in rat medullary dorsal horn neurons

  • Lee, Hae In;Park, Byung Rim;Chun, Sang Woo
    • The Korean Journal of Physiology and Pharmacology
    • /
    • 제21권4호
    • /
    • pp.371-376
    • /
    • 2017
  • The caudal subnucleus of the spinal trigeminal nucleus (medullary dorsal horn; MDH) receives direct inputs from small diameter primary afferent fibers that predominantly transmit nociceptive information in the orofacial region. Recent studies indicate that reactive oxygen species (ROS) is involved in persistent pain, primarily through spinal mechanisms. In this study, we aimed to investigate the role of xanthine/xanthine oxidase (X/XO) system, a known generator of superoxide anion ($O_2{^-}$), on membrane excitability in the rat MDH neurons. For this, we used patch clamp recording and confocal imaging. An application of X/XO ($300{\mu}M/30mU$) induced membrane depolarization and inward currents. When slices were pretreated with ROS scavengers, such as phenyl N-tert-butylnitrone (PBN), superoxide dismutase (SOD), and catalase, X/XO-induced responses decreased. Fluorescence intensity in the DCF-DA and DHE-loaded MDH cells increased on the application of X/XO. An anion channel blocker, 4,4-diisothiocyanatostilbene-2,2-disulfonic acid (DIDS), significantly decreased X/XO-induced depolarization. X/XO elicited an inward current associated with a linear current-voltage relationship that reversed near -40 mV. X/XO-induced depolarization reduced in the presence of $La^{3+}$, a nonselective cation channel (NSCC) blocker, and by lowering the external sodium concentration, indicating that membrane depolarization and inward current are induced by influx of $Na^+$ ions. In conclusion, X/XO-induced ROS modulate the membrane excitability of MDH neurons, which was related to the activation of NSCC.

QUANTUM EXTENSIONS OF FOURIER-GAUSS AND FOURIER-MEHLER TRANSFORMS

  • Ji, Un-Cig
    • 대한수학회지
    • /
    • 제45권6호
    • /
    • pp.1785-1801
    • /
    • 2008
  • Noncommutative extensions of the Gross and Beltrami Laplacians, called the quantum Gross Laplacian and the quantum Beltrami Laplacian, resp., are introduced and their basic properties are studied. As noncommutative extensions of the Fourier-Gauss and Fourier-Mehler transforms, we introduce the quantum Fourier-Gauss and quantum Fourier- Mehler transforms. The infinitesimal generators of all differentiable one parameter groups induced by the quantum Fourier-Gauss transform are linear combinations of the quantum Gross Laplacian and quantum Beltrami Laplacian. A characterization of the quantum Fourier-Mehler transform is studied.

m-비트 병렬 BCH 인코더의 새로운 설계 방법 (A new design method of m-bit parallel BCH encoder)

  • 이준;우중재
    • 융합신호처리학회논문지
    • /
    • 제11권3호
    • /
    • pp.244-249
    • /
    • 2010
  • 차세대 멀티 레벨 셀 플래시 메모리들을 위해 복잡도가 낮은 에러 정정 코드 구현에 대한 요구가 커지고 있다. 일반적으로 부 표현 (sub-expression) 들을 공유하는 것은 복잡도와 칩 면적을 줄이기 위한 효과적인 방법이다. 본 논문에서는 직렬 선형 귀환 쉬프트 레지스터 구조를 기반으로 부 표현들을 이용한 저 복잡도 m-비트 병렬 BCH 인코더 구현 방법을 제안한다. 또한, 부 표현들을 탐색하기 위한 일반화된 방법을 제시한다. 부 표현들은 패리티 생성을 위해 사용하는 행렬(생성 행렬, generator matrix)의 부 행렬 (sub-matrix)과 다른 변수들의 합과의 행렬 연산에 의해 표현된다. 부 표현들의 수는 개로 한정되며, 탐색된 부 표현들은 다른 병렬 BCH 인코더 구현을 위해 공유되어질 수 있다. 본 논문은 구현 과정에서 다수의 팬 아웃에 의해 발생하는 문제점(지연)의 해결이 아닌 복잡도(로직 사이즈) 감소에 그 목적이 있다.