• 제목/요약/키워드: Linear damping

검색결과 667건 처리시간 0.027초

슬릿형 강재이력 감쇠장치의 성능평가를 위한 실험연구 (An Experimental Study on Performance Evaluation of Hysteretic Steel Slit Damper)

  • 최기선;이현지;김민선;유영찬
    • 대한건축학회논문집:구조계
    • /
    • 제34권1호
    • /
    • pp.33-39
    • /
    • 2018
  • This study performed experimental validation of the hysteretic steel slit damper's basic and dependent characteristics, which should be considered for the design. The basic characteristic of the steel slit damper is used for determining design properties of non-linear analysis, such as yielding strength, yielding displacement, elastic stiffness and post-yielding stiffness. In order to evaluate dependent characteristics of the hysteretic steel slit damper, repeated deformation capacity with respect to the displacement, velocity and aspect ratio of the damper was evaluated. In this study, steel slit damper, which is widely used in Korea, was considered. The slit dampers with 55kN and 240kN of yielding strength were produced and tested. It was concluded that the slit damper's hysteresis behavior was affected by the dependent characteristics: displacement, velocity and aspect ratio. In other words, the steel slit damper's behavior was stable within limit displacement, and aspect ratio of the strut affected repeated deformation capacity of the damper subjected to large deformation. In addition, it was observed that the repeated deformation capacity abruptly decreased at the high speed range (${\geq}60mm/sec$). Furthermore, the experimental results were evaluated with the criterion of the damping device specified in ASCE7-10.

Electromagnetic Electron-Cyclotron Wave for Ring Distribution with Alternating Current (AC) Electric Field in Saturn Magnetosphere

  • Haridas, Annex Edappattu;Kanwar, Shefali;Pandey, Rama Shankar
    • Journal of Astronomy and Space Sciences
    • /
    • 제39권2호
    • /
    • pp.35-42
    • /
    • 2022
  • During their respective missions, the spacecraft Voyager and Cassini measured several Saturn magnetosphere parameters at different radial distances. As a result of information gathered throughout the journey, Voyager 1 discovered hot and cold electron distribution components, number density, and energy in the 6-18 Rs range. Observations made by Voyager of intensity fluctuations in the 20-30 keV range show electrons are situated in the resonance spectrum's high energy tail. Plasma waves in the magnetosphere can be used to locate Saturn's inner magnetosphere's plasma clusters, which are controlled by Saturn's spin. Electromagnetic electron cyclotron (EMEC) wave ring distribution function has been investigated. Kinetic and linear approaches have been used to study electromagnetic cyclotron (EMEC) wave propagation. EMEC waves' stability can be assessed by analyzing the dispersion relation's effect on the ring distribution function. The primary goal of this study is to determine the impact of the magnetosphere parameters which is observed by Cassini. The magnetosphere of Saturn has also been observed. When the plasma parameters are increased as the distribution index, the growth/damping rate increases until the magnetic field model affects the magnetic field at equator, as can be seen in the graphs. We discuss the outputs of our model in the context of measurements made in situ by the Cassini spacecraft.

Seismic responses of hyperbolic cooling towers under horizontal and vertical earthquake

  • Zhang, Jun-Feng;Wang, Yuan-Hao;Li, Jie;Zhao, Lin
    • Earthquakes and Structures
    • /
    • 제20권4호
    • /
    • pp.405-415
    • /
    • 2021
  • Following the dynamic property analysis and elaboration, linear response spectrum analysis (RSA) and response history analysis (RHA) were conducted on a representative hyperbolic cooling towers (HCT) in present study. The seismic responses in tower shell were illustrated in detail, including the internal force amplitude, modal contribution, influence from damping ratio, comparison of results got from RSA and RHA and especially the latitude distributions of internal forces. The results show that the eigenmodes could be classified in a new method into four types according to their mode shapes and only the lateral bending modes and vertical stretching modes are meaningful for horizontal and vertical earthquake correspondingly. The bending modes and seismic deformation display the same feature which is global lateral bending accompanied by minute circular flow displacement of section. This feature also decides the latitude distributions of internal forces as sine or cosine. Moreover, the following method is also proposed for approximate estimation of internal force amplitudes without time-consuming response history analysis: getting the response spectrums of the selected ground accelerations and then comparing values of response spectrums at the natural period of first lateral bending mode because it is always prime dominant for horizontal seismic responses.

Thermomechanical and electrical resistance characteristics of superfine NiTi shape memory alloy wires

  • Qian, Hui;Yang, Boheng;Ren, Yonglin;Wang, Rende
    • Smart Structures and Systems
    • /
    • 제30권2호
    • /
    • pp.183-193
    • /
    • 2022
  • Structural health monitoring and structural vibration control are multidisciplinary and frontier research directions of civil engineering. As intelligent materials that integrate sensing and actuation capabilities, shape memory alloys (SMAs) exhibit multiple excellent characteristics, such as shape memory effect, superelasticity, corrosion resistance, fatigue resistance, and high energy density. Moreover, SMAs possess excellent resistance sensing properties and large deformation ability. Superfine NiTi SMA wires have potential applications in structural health monitoring and micro-drive system. In this study, the mechanical properties and electrical resistance sensing characteristics of superfine NiTi SMA wires were experimentally investigated. The mechanical parameters such as residual strain, hysteretic energy, secant stiffness, and equivalent damping ratio were analyzed at different training strain amplitudes and numbers of loading-unloading cycles. The results demonstrate that the detwinning process shortened with increasing training amplitude, while austenitic mechanical properties were not affected. In addition, superfine SMA wires showed good strain-resistance linear correlation, and the loading rate had little effect on their mechanical properties and electrical resistance sensing characteristics. This study aims to provide an experimental basis for the application of superfine SMA wires in engineering.

Dynamic characteristics of viscoelastic nanobeams including cutouts

  • Rabab A. Shanab;Norhan A. Mohamed;Mohamed A. Eltaher;Alaa A. Abdelrahman
    • Advances in nano research
    • /
    • 제14권1호
    • /
    • pp.45-65
    • /
    • 2023
  • This paper aimed to investigate the nonclassical size dependent free vibration behavior of regularly squared cutout viscoelastic nanobeams. The nonlocal strain gradient elasticity theory is modified and adopted to incorporate the viscoelasticity effect. The Kelvin Voigt viscoelastic model is adopted to model the linear viscoelastic constitutive response. To explore the influence of shear deformation effect due to cutout, both Euler Bernoulli and Timoshenko beams theories are considered. The Hamilton principle is utilized to derive the dynamic equations of motion incorporating viscoelasticity and size dependent effects. Closed form solutions for the resonant frequencies for both perforated Euler Bernoulli nanobeams (PEBNB) and perforated Timoshenko nanobeams (PTNB) are derived considering different boundary conditions. The developed procedure is verified by comparing the obtained results with the available results in the literature. Parametric studies are conducted to show the influence of the material damping, the perforation, the material and the geometrical parameters as well as the boundary and loading conditions on the dynamic behavior of viscoelastic perforated nanobeams. The proposed procedure and the obtained results are supportive in the analysis and design of perforated viscoelastic NEMS structures.

누설유량과 회전체동역학적 성능을 고려한 래버린스 씰 설계 (Labyrinth Seal Design Considering Leakage Flow Rate and Rotordynamic Performance)

  • 문민주;이정인;서준호
    • Tribology and Lubricants
    • /
    • 제39권2호
    • /
    • pp.61-71
    • /
    • 2023
  • This study proposes a procedure for designing a labyrinth seal that meets both leakage flow rate and rotordynamic performance criteria (effective damping, amplification factor, separation margin, logarithmic decrement, and vibration amplitude). The seal is modeled using a one control volume (1CV) bulk flow approach to predict the leakage flow rate and rotordynamic coefficients. The rotating shaft is modeled with the finite element (FE) method and is assumed to be supported by two linearized bearings. Geometry, material and operating conditions of the rotating shaft, and the supporting characteristics of the bearings were fixed. A single labyrinth seal is placed at the center of the rotor, and the linearized dynamic coefficients predicted by the seal numerical model are inserted as linear springs and dampers at the seal position. Seal designs that satisfy both leakage and rotordynamic performance are searched by modifying five seal design parameters using the multi-grid method. The five design parameters include pre-swirl ratio, number of teeth, tooth pitch, tooth height and tooth tip width. In total, 12500 seal models are examined and the optimal seal design is selected. Finally, normalization was performed to select the optimal labyrinth seal designs that satisfy the system performance requirements.

Grey algorithmic control and identification for dynamic coupling composite structures

  • ZY Chen;Ruei-yuan Wang;Yahui Meng;Timothy Chen
    • Steel and Composite Structures
    • /
    • 제49권4호
    • /
    • pp.407-417
    • /
    • 2023
  • After a disaster like the catastrophic earthquake, the government have to use rapid assessment of the condition (or damage) of bridges, buildings and other infrastructures is mandatory for rapid feedbacks, rescue and post-event management. Many domain schemes based on the measured vibration computations, including least squares estimation and neural fuzzy logic control, have been studied and found to be effective for online/offline monitoring of structural damage. Traditional strategies require all external stimulus data (input data) which have been measured available, but this may not be the generalized for all structures. In this article, a new method with unknown inputs (excitations) is provided to identify structural matrix such as stiffness, mass, damping and other nonlinear parts, unknown disturbances for example. An analytical solution is thus constructed and presented because the solution in the existing literature has not been available. The goals of this paper are towards access to adequate, safe and affordable housing and basic services, promotion of inclusive and sustainable urbanization and participation, implementation of sustainable and disaster-resilient buildings, sustainable human settlement planning and manage. Simulation results of linear and nonlinear structures show that the proposed method is able to identify structural parameters and their changes due to damage and unknown excitations. Therefore, the goal is believed to achieved in the near future by the ongoing development of AI and control theory.

The influence of concrete degradation on seismic performance of gravity dams

  • Ahmad Yamin Rasa;Ahmet Budak;Oguz Akin Duzgun
    • Earthquakes and Structures
    • /
    • 제26권1호
    • /
    • pp.59-75
    • /
    • 2024
  • This paper presents a dam-reservoir interaction model that includes, water compressibility, sloshing of surface water, and radiation damping at the far-end reservoir, to investigate the influence of concrete deterioration on seismic behavior along with seismic performance of gravity dams. Investigations on seismic performance of the dam body have been conducted using the linear time-history responses obtained under six real and 0.3 g normalized earthquake records with time durations from 10 sec to 80 sec. The deterioration of concrete is assumed to develop due to mechanical and chemical actions over the dam lifespan. Several computer programs have been developed in FORTRAN 90 and MATLAB programming languages to analyze the coupled problem considering two-dimensional (2D) plane-strain condition. According to the results obtained from this study, the dam structure shows critical responses at the later ages (75 years) that could cause disastrous consequences; the critical effects of some earthquake loads such as Chi-Chi with 36.5% damage and Loma with 56.2% damage at the later ages of the selected dam body cannot be negligible; and therefore, the deterioration of concrete along with its effects on the dam response should be considered in analysis and design.

철근콘크리트 연성 모멘트골조에 대한 반응수정계수와 비선형 변위량의 평가 (Estimation of Response Modification Factor and Nonlinear Displacement for Moment Resisting Reinforced Concrete Frames)

  • 김길환;전대한;이상호
    • 한국지진공학회논문집
    • /
    • 제6권2호
    • /
    • pp.29-37
    • /
    • 2002
  • 본 연구는 철근콘크리트 연성 모멘트골조의 선형.비선형 정적해석을 통한 반응수정계수와 비선형 변위량을 평가하여 합리적인 내진설계의 기초자료를 제공하는 것을 목적으로 한다. 먼저 국내 내진설계 규준에 따라 각 모델을 설계한 후, 철근콘크리트 연성 모멘트골조의 반응수정계수와 비선형 변위량을 평가하였으며, 해석에 사용된 모델은 층수(10, 20, 30), 평면비(1:1, 1:2), 해석방법(2D, 3D)을 변수로 한 27개의 모델이다. 반응수정계수와 비선형 변위량의 평가는 각 모델별 선형.비선형 정적해석을 수행하여 그 결과를 비교 분석하여 산정하였다. 반응수정계수는 강도계수, 연성계수, 잉여도계수, 감쇠계수의 곱으로 산정하였고, 그 결과 해석방향의 저항골조의 수에 따라 2 스팬인 경우 3.5, 3 스팬인 경우 4.3, 4 스팬 이상인 경우에는 평면비나 층수와 상관없이 5.0에 근접한 결과를 나타내었다. 비선형 변위량은 층간변위각비(비선형 변위각/선형 변위각)에 의해 평가되었으며, 층간변위각비는 5.85에서 9.34로 나타났다.

중력하중 설계된 1:5 축소 3층 철근콘크리트 골조의 지진모의실험 (Earthquake Simulation Tests of A 1:5 Scale Gravity Load Designed 3-Story Reinforced Concrete Frame)

  • 이한선;우성우
    • 콘크리트학회지
    • /
    • 제10권6호
    • /
    • pp.241-252
    • /
    • 1998
  • 이 연구의목적은 여러 수준의 지진에 대한 비내진 상세를 가진 저층 모멘트 저항 골조의 실제 반응을 관찰하기 위한 것이다. 우선 모델에 대한 축소율은 사용된 진동대의 용량을 고려하여 1 : 5 로 결정하였으며 상사성의 법칙에 따라 모델을 제작하였다. 그 다음에 이 모델에 대해 Taft N21E 지진가속도 기록의 최대 지진가속도를 0.12g. 0.2g, 0.4g로 조정하여 진동대를 이용한 지진모의실험을 수행하였다. 각 층별 횡방향 가속도와 변위, 그리고 구조물의 취약부위에서 국부변형이 측정되었다. 밑면 전단력은 손수 만든 로드셀을 이용하여 측정하엿다. 각 지진모의실험 전과 후에는 고유주기와 감쇠비의 변화를 살펴보기 위해 자유진동실험을 수행하였다. 전체거동과 국부거동에 대한 실험결과를 분석한 결과, 이 모델은 우리나라의 현행 내진 설계 기준에서의 설계지진 즉, 0.12g의 최대 지진가속에 대해서는 선형탄성으로 거동하였다. 최대 밑면 전단력은 1.8tf 로 설계 밑면 전단력의 약 4.7배로나타났다.이 실험모델은 높은 수준의 지진모의실험에서도 양호한 성능을 나타내었다. 높은 수준의지진에 대한 저항의 주요요소는 1)높은 초과강도, 2)기본주기의 증가, 그리고 3)비탄성 변형에 의한 얼마간의 에너지소산이다. 이 실험에서 모델의 층간변위는 대략 허용한계 내에 있었다.