• Title/Summary/Keyword: Linear cavity laser

Search Result 28, Processing Time 0.019 seconds

Linear interrogation of fiber Bragg grating sensor array using time-delayed quadrature sampling technique (시간지연 샘플링을 이용한 광섬유 격자 센서어레이의 선형 복조)

  • 김종섭;송민호
    • Korean Journal of Optics and Photonics
    • /
    • v.15 no.1
    • /
    • pp.34-38
    • /
    • 2004
  • A fiber laser of which wavelength was scanned by an intra-cavity FP (Fabry-Perot) filter was used to interrogate a fiber Bragg grating strain sensor array. We calculated the wavelength variation of the fiber laser using quadrature signal processing with an unbalanced M/Z (Mach-Zehnder) interferometer and time-delayed sampling technique. The calculated wavelengths are mapped to corresponding temporal reflection peaks from the sensor array, which enables more accurate and stable interrogation without the problems caused by the FP filter's nonlinear characteristics. Wavelength resolution of ∼20 pm was obtained in our experimental setup, which could have been greatly enhanced with faster phase modulation.

Mid-infrared Continuous-wave Optical Parametric Oscillator with a Fan-out Grating MgO:PPLN Operating Up to 5.3 ㎛

  • Bae, In-Ho;Yoo, Jae-Keun;Lim, Sun Do;Kim, Seung Kwan;Lee, Dong-Hoon
    • Current Optics and Photonics
    • /
    • v.3 no.6
    • /
    • pp.577-582
    • /
    • 2019
  • We report on a continuous-wave (cw) optical parametric oscillator (OPO) optimized for mid-infrared emission above 5.0 ㎛. The OPO is based on a magnesium-oxide-doped periodically poled LiNbO3(MgO:PPLN) crystal with a fan-out grating design. A linear two-mirror cavity resonating both at the pump and signal wavelengths is stabilized to the pump laser by using the modified Pound-Drever-Hall (PDH) method. The idler wavelength is continuously tunable from 4.7 ㎛ up to 5.3 ㎛ by varying the poling period of the fan-out grating crystal. Pumped by a diode-pumped solid state (DPSS) laser with a power of 1.1 W at 1064 nm, the maximum idler output power is measured to be 5.3 mW at 4.8 ㎛. The output power above 5.0 ㎛ is reduced to the hundreds of ㎼ level due to increased absorption in the crystal, but is stable and strong enough to be measured with a conventional detector.

Dual Wavelength Erbium-doped Fiber Laser with Lasing Wavelength Switchability and Tunability (파장 가변 및 스위칭이 가능한 쌍파장 어븀 첨가 광섬유 레이저)

  • Park, Sang-Oh;Shim, Young-Bo;Yoon, Min-Seok;Chu, Su-Ho;Kim, Hyun-Joo;Kwon, Oh-Jang;Han, Young-Geun
    • Korean Journal of Optics and Photonics
    • /
    • v.21 no.5
    • /
    • pp.181-184
    • /
    • 2010
  • A simple technique for a flexibly tunable and switchable dual wavelength-switchable erbium-doped fiber (EDF) laser using fiber Bragg gratings is proposed and demonstrated by using both linear cavity loss controlling and homogeneous gain broadening of the EDF. The oscillating wavelength switching is successfully realized by using the modulation of the acousto-optic modulator driven by the RF signal. The wavelength spacing and lasing wavelength of the proposed wavelength-switchable laser can also be controlled by using the bending-induced tension or compression strain. The proposed tunable dual wavelength-switchable fiber laser has a lot of advantages, such as a high extinction ratio larger than 40dB and a high tunability of ~7.2 nm/$m^{-1}$.

Velocity and Pressure Measurement of Channel Cavity Flow by PTV (PTV에 의한 채널캐비티 유동의 속도 및 압력계측)

  • Cho, D.H.;Kim, J.G.;Lee, Y.H.
    • Solar Energy
    • /
    • v.17 no.3
    • /
    • pp.59-66
    • /
    • 1997
  • The present study adopted the PTV method for the velocity acquisition. The system consists of an image grabber built-in a personal computer and a laser-based sheet light projector and particle identification softwares. Velocity vectors are obtained, by PTV and they are used as velocity components for Poisson equation for pressure. Related boundary conditions and no-slip condition at solid wall and the linear velocity extrapolation on the upper side of cavity are well examined for the present study. For calculation of pressure, resolution of grid is basically $40{\times}40$ and 2-dimensional uniform mesh using MAC staggered grid is adopted. The result of experiment reveal that, newly suggested measuring method is capable of estimating pressure and velocity distribution of flow field reasonably.

  • PDF

Numerical Research on the Lock-in Compensation Method of a Ring Laser Gyroscope for Reducing INS Alignment Time (관성항법장치 초기정렬시간 단축을 위한 링레이저 자이로 lock-in오차 보상방법의 수치해석적인 분석)

  • Shim, Kyu-Min;Jang, Suk-Won;Paik, Bok-Soo;Chung, Tae-Ho;Moon, Hong-Key
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.37 no.3
    • /
    • pp.275-282
    • /
    • 2009
  • Generally, the sinusoidal cavity dither is adopted to ring laser gyroscope for eliminating the lock-in which is non-linear effect at the small rotation input. Despite this method, there are some remained errors which are generated at the dither turnaround, and those errors produce random walk which is a general character of a ring laser gyroscope. As one of the numerous research results for compensating these errors, there is a special lock-in compensation method which is the method of error estimation and compensation by comparing the beat signal periods of before and after the dither turnarounds. In this paper, by ring laser gyroscope modeling and numerical analysis, we verified the theoretical validity and confirmed the effectiveness of this method in expectation of the possible beat signal measurement time resolution. As a result, we confirmed the random walk decreases from a-half to a-third by this lock-in compensation method. So, it is expected to be a remarkable method for reducing the INS alignment time.

Saturated Absorption Spectroscopy of 13C2H2 in the Near Infrared Region

  • Moon, H. S.;Lee, W. K.;Suh, H. S.
    • Journal of the Optical Society of Korea
    • /
    • v.8 no.1
    • /
    • pp.1-5
    • /
    • 2004
  • Using the external cavity spectroscopy method, we have observed the saturated absorption spectrum of the P(16) line of the v$_1$+v$_3$ band of $^{13}C$_2$H$_2$$. The frequency of a laser has been stabilized to the saturated absorption spectrum. The relative contrast of the saturation spectrum is about 7% with respect to the linear absorption and the linewidth is about 1.8 MHz. The frequency fluctuation of the stabilized LD is about $\pm$ 20 KHz for a sampling time of 100 ms.

Saturated absorption spectroscopy of 13C2H2 in the 1550 nm region (1550 nm 영역에서 아세틸렌 분자의 포화흡수분광)

  • 문한섭;이원규;서호성
    • Korean Journal of Optics and Photonics
    • /
    • v.15 no.2
    • /
    • pp.177-182
    • /
    • 2004
  • We have observed the saturated absorption spectrum of the P(16) line of the V$_1$+V$_3$ band of $^{13}$ C$_2$H$_2$ molecule by using the external cavity spectroscopy method. The frequency of laser has been stabilized to the saturated absorption spectrum. The relative contrast of the saturation spectrum is about 7 % with respect to the linear absorption and the linewidth is about 1.8 MHz. The frequency fluctuation of the stabilized LD is about $\pm$20 KHz during the sampling time 100 S.

Nonlinearity of semiconductor optical amplifier and gain-clamping effects of Iaser-injected semiconductor optical amplifier in wavelength division mulitiplexing (파장 다중 광통신에서의 반도체 광증폭기의 비선형성과 연속파동 레이저가 입사된 반도체 광증폭기의 이득고정 효과)

  • 김동철;유건호;김형문;주흥로;한선규;주관종
    • Korean Journal of Optics and Photonics
    • /
    • v.11 no.1
    • /
    • pp.37-42
    • /
    • 2000
  • We have numerically solved rate-equations of semiconductor optical amplifier (SOA) to understand the characteristics of SOA. The rate-equations we have used can describe injection carrier density, amplified spontaneous emission and signal photon density in spatial and time domain by dividing the cavity into multi-section. We have investigated injection carrier density, amplified spontaneous emission and signal photon density as a function of position and time in the case of single channel input in the form of square pulse. Also we have analyzed the non-linear phenomena of SOA in the case of injecting multi-channel wavelengths as in WDM. Intermodulation distortion (IMD) caused by beat among channels has significant effects on the signal distortion as the channel spacing becomes narrower, and channel crosstalk becomes larger as the power of signals increases. In the case of the injection of another CW laser whose wavelength is far enough from the signal wavelengths, the crosstalk and the output signal distortion can be significantly reduced. duced.

  • PDF