• 제목/요약/키워드: Linear Cell Source

검색결과 53건 처리시간 0.025초

Temperature Analysis for the Linear Cell in the Vapor Deposition Process

  • Choi Jongwook;Kim Sungcho;Kim Jeongsoo
    • Journal of Mechanical Science and Technology
    • /
    • 제19권6호
    • /
    • pp.1329-1337
    • /
    • 2005
  • The OLED (Organic Light Emitting Diodes) display recently used for the information indicating device has many advantages over the LCD (Liquid Crystal Display), and its demand will be increased highly. The linear cell should be designed carefully considering the uniformity of thin film on the substrate. Its design needs to compute the temperature field analytically because the uniformity for the thin film thickness depends on the temperature distribution of the source (organic material). In the present study, the design of the linear cell will be modified or improved on the basis of the temperature profiles obtained for the simplified linear cell. The temperature distributions are numerically calculated through the STAR-CD program, and the grids are generated by means of the ICEM CFD program. As the results of the simplified linear cell, the temperature deviation was shown in the parabolic form among the both ends and the center of the source. In order to reduce the temperature deviation, the configuration of the rectangular ends of the crucible was modified to the circular type. In consequence, the uniform temperature is maintained in the range of about 90 percent length of the source. It is expected that the present methods and results on the temperature analysis can be very useful to manufacture the vapor deposition device.

유기반도체 박막증착을 위한 선형증착원의 유체유동해석 (Analysis of Fluid Flow in the Linear Cell Source for Organic Semiconductor Thin Film Deposition)

  • 곽인철;양영수;최범호;김영미
    • 한국정밀공학회지
    • /
    • 제26권10호
    • /
    • pp.74-80
    • /
    • 2009
  • This paper presents a study on fluid flow analysis of organic semiconductor thin film deposition process using the computational numerical method. In the production process, the thickness of deposited organic thin film depends on distribution of nozzle size in the linear cell system, so we analyze to decide the optimal nozzle system for uniform thickness of organic thin film. The results of deposited thickness of thin film by numerical analysis are in good agreement with those of the experimental measurements.

유기EL 증착 공정에 대한 3차원 Monte Carlo 해석 (Three Dimensional Direct Monte Carlo Simulation on OLED Evaporation Process)

  • 이응기
    • 반도체디스플레이기술학회지
    • /
    • 제8권4호
    • /
    • pp.37-42
    • /
    • 2009
  • The performance of an OLED(organic luminescent emitting device) fabrication system strongly depends on the design of the evaporation cell-source. Trends in display sizes have hauled the enlargement of mother glass substrates. The enlargement of substrates requires the improvement and the enlargement of the effusion cell-source for OLED evaporation process. The deposited layers should be as uniform as possible, and therefore it is important to know the effusion profile of the molecules emitted from the cell-source. Conventional 2D DSMC algorithm cannot be used for simulating the new concept cell-source design, such as a linear source. This work concerns the development of 3D DSMC (direct simulation Monte Carlo) analysis for simulating the behavior of the evaporation cell-sources. In this paper, the 3D DSMC algorithm was developed and the film thickness profiles were obtained by the numerical analysis.

  • PDF

Temperature Analysis for Optimizing the Configuration of the Linear Cell

  • Choi Jong-Wook;Kim Sung-Cho;Kim Jeong-Soo
    • Journal of Mechanical Science and Technology
    • /
    • 제20권7호
    • /
    • pp.1089-1097
    • /
    • 2006
  • The market demand of display devices is drastically increasing in the information technology age. The research on OLED (Organic Light Emitting Diodes) display with the luminescence in itself is being more paid attention than LCD (Liquid Crystal display) with the light source from the back. The vapor deposition process is most essential in manufacturing OLED display. The temperature distribution of the linear cell in this process is closely related to securing the uniformity of organic materials on the substrate. This work analyzed the temperature distribution depending on the intervals between the crucible and the heating band as well as on the amount of the heat flux from the heating band. Moreover, the roles of the water jacket and the configuration of the cover within the linear cell were examined through the temperature analysis for six configurations of the linear cell. Under the above temperature analysis, the variations in the intervals and the amount of the heat flux were considered to have an effect on building the uniform temperature distribution within the crucible. It is predicted that the water jacket and the adequate configuration of the cover will prevent the blowout and clogging phenomena, respectively. The results can be used as the fundamental data for designing the optimal linear cell.

Single Cell Li-ion 전지 충전 IC (Single Cell Li-ion Battery Charger)

  • 이락현;김준식;박시홍
    • 한국전기전자재료학회논문지
    • /
    • 제22권7호
    • /
    • pp.576-579
    • /
    • 2009
  • This paper suggests a autonomous linear Li-ion battery charger which can safely distribute power between an external power source(AC adapter, auto adapter, or USB source), battery, and the system load. Depending on an external power source's capability, the charger selects proper charging-mode automatically. The charger IC designed and fabricated on Dongbu HITEC's $0.35{\mu}m$ BCD process with layers of one poly and three metals.

OLED 박막 증착공정에서 유도로 내부의 분자유동 해석 (Simulation of Molecular Flows Inside a Guide Block in the OLED Deposition Process)

  • 성재용;이응기
    • 한국공작기계학회논문집
    • /
    • 제17권2호
    • /
    • pp.45-50
    • /
    • 2008
  • Molecular flows inside a guide block in the OLED(organic luminescent emitting device) deposition process have been simulated using DSMC(direct simulation Monte Carlo) method. Because the organic materials are evaporated under vacuum, molecules flow at a high Knudsen number of the free molecular regime, where the continuum mechanics is not valid. A guide block is designed as a part of the linear cell source to transport the evaporated materials to a deposition chamber, When solving the flows, the inlet boundary condition is proved to affect significantly the whole flow pattern. Thus, it is proposed that the pressure should be specified at the inlet. From the analysis of the density distributions at the nozzle exit of the guide block, it is shown that the longer nozzle can emit molecules more straightly. Finally, a nondimensionalized mass flow profile is obtained by numerical experiments, where various nozzle widths and inlet pressures are tested.

Roles of Glucose and Acetate as Carbon Sources in L-Histidine Production with Brevibacterium flavum FERM1564 Revealed by Metabolic Flux Analysis

  • Shioya, Suteaki;Shimizu, Hiroshi;Shimizu, Nobuyuki
    • Biotechnology and Bioprocess Engineering:BBE
    • /
    • 제7권3호
    • /
    • pp.171-177
    • /
    • 2002
  • The metabolic flux pattern for L-histidine production was analyzed when glucose and/or acetate were used as carbon sources. Total L-histidine production was enhanced when mixed substrate (glucose and acetate) was used, compared wish that when either glucose or acetate was used as the sole carbon source. Theoretical maximum carbon fluxes through the main pathways for L-histldine production, cell growth, and ATP consumption for cell maintenance were obtained by the linear programming (LP) method. By comparison of the theoretical maximum carbon fluxes tilth actual ones, it was found that a large amount of glucose was actually used for maintenance of cell viability. On the other hand, acetate was used for cell growth. After depletion of acetate in the mixed substrate culture, the flux for glucose to L-histldine synthesis was markedly enhanced. A strategy for effective L-histidine production using both carbon sources was proposed.

Single Cell Li-ion 전지 충전 IC (A Single Cell Li-ion Battery Charger)

  • 이락현;김준식;박시홍
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2009년도 춘계학술대회 논문집
    • /
    • pp.27-28
    • /
    • 2009
  • This paper suggests a autonomous linear Li-ion battery charger which can safely distribute power between an external power source(AC adapter, auto adapter, or USB source), battery, and the system load. Depending on an external power source's capability, the charger selects proper charging-mode automatically. The charger IC designed and fabricated on Dongbu HITEC's $0.35{\mu}m$ BCD process with layers of one poly and three metals.

  • PDF

가정용 연료전지 시스템의 계통연계 시 수용가 및 배전계통에서의 고조파 영향 평가 (An Assessment on Harmonics Effect in Customer and the Distributed Power System during Grid Connection of Residential Fuel Cell System)

  • 박찬엄;정진수;한운기
    • 전기학회논문지
    • /
    • 제60권6호
    • /
    • pp.1280-1285
    • /
    • 2011
  • Recently, due to the use of fossil fuels for electric power production, carbon emissions increased excessively. Thereby, in order to replace fossil fuels, many studies about fossil fuels such as solar and fuel cell energy source are progressing. Fuel cell system has high energy conversion efficiency. Also, fuel cell system is environmentally friendly system because the carbon emission is almost not occur. Therefore, the fuel cell system is considered as the core technology of in the fields of the future energy and environmental. Fuel cell system has an effect on distribution power system because another power source of other than large power plants. So, fuel cell system can be degradation reason of power quality in the power system. In this paper, we constructed the system for an assessment on harmonics effect. The system is composed with power source, harmonics generation and linear load, fuel cell system. we also performed assessment on harmonics effect in customer and the distributed power system during grid connection of residential fuel cell system. An assessment cases are divided into three. A Case 1 is state that residential load and fuel system are connected to grid, Case 2 is state that residential load and harmonics load are connected to grid, and Case 3 is state that all loads are connected to grid. As a output of fuel cell system is increase, analysis results based on assessment system showed that power quality became more aggravation as effect of harmonics.