• 제목/요약/키워드: Line-type finite element

검색결과 91건 처리시간 0.023초

유한요소해석을 이용한 비대칭 평면형 결합선로 설계 (Design of Asymmetrical Parallel Coupled lines Using Finite Element Analysis)

  • 윤재호;박준석;안달;김형석
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 C
    • /
    • pp.1841-1843
    • /
    • 2001
  • Asymmetrical parallel coupled lines are used in a number of circuits such as multi-band coupler and combline type band pass filter. Although graphical results and formulas are available for the design of coupled lines, the design procedure is hard to use, because even- and odd- mode impedances are always expressed in terms of the physical geometry. In this paper, we introduce a method to find design parameter using finite element analysis. By employing the capacitance obtained by FE analysis, design parameters for each lines are extracted. To show the validity of extracted design parameter for asymmetrical parallel coupled line, we have designed and simulated a planar type combline band pass filter.

  • PDF

리니어 타입 크로스 롤러 가이드 공압 액추에이터의 신뢰성 평가에 관한 연구 (A Study on the Reliability Analysis for a Linear Type Pneumatic Actuator with Cross Roller Guide)

  • 신봉철;조명우;강성민;이수진;최진화
    • 한국정밀공학회지
    • /
    • 제23권5호
    • /
    • pp.184-189
    • /
    • 2006
  • This research presents the performance analysis of the linear type pneumatic actuators that are used in semi-conductor assembly line to transfer some product with high accuracy. To increase positioning and repetitive accuracies, a cross roller guide is implemented inside the pneumatic actuator. The finite element method is used to verify the force against working moments, and reliability analysis is performed to classify the breakdown cases. Also, reliability, failure rate, probability density function, and $B_{10}$ to life are estimated under the boundary of thrust or air leakage conditions. In this study, the failure probabilistic function of the pneumatic actuators is analyzed using Weibull distribution.

고온 복합재료의 경화 모니터링을 위한 고온 유전센서의 제작 및 성능평가에 관한 연구 (A Study on the Performance Test and Manufacture of the Dielectric Sensor for the Cure Monitoring of the High Temperature Composites)

  • 김일영;최진호;이대길
    • Composites Research
    • /
    • 제14권1호
    • /
    • pp.30-38
    • /
    • 2001
  • 복합재료는 우수한 비강성, 비강도 특성 때문에 기존의 항공우주산업뿐만 아니라 로봇 팔. 공작기계 등에 널리 사용되고 있다. 복합재료 경화중의 온라인 모니터링기법은 생산성 향상 및 품질의 신뢰성 향상을 위하여 매우 중요한 연구분야로 대두되고 있다. 본 논문에서는 휘스톤 브리지식 유전회로를 설계하고 제작하였다. 또한 고온 경화 복합재료에 적용할 수 있는 고온 유전센서를 개발하여 그 성능을 평가하였다. 유한요소해석을 이용하여 유전 센서에 작용하는 열 잔류응력을 계산하였으며, 고온분위기 하에서 유전센서의 유전특성을 평가하였다. 이상에서 개발된 유전회로와 고온 유전센서를 이용하여 BMI(Blsmaleimlde) 수지의 경화모니터링을 수행하였다.

  • PDF

절단피개량과 절단변연형태 및 하중각도가 도재라미네이트 베니어 내의 응력분포에 미치는 영향에 관한 삼차원 유한요소법적 연구 (THREE-DIMENSIONAL FINITE ELEMENT ANALYSIS OF STRESS DISTRIBUTION IN PORCELAIN LAMINATE VENEERS WITH VARIOUS AMOUNTS OF INCISAL COVERAGE AND TYPES OF INCISAL FINISH LINE UNDER TWO LOADING CONDITIONS)

  • 류경희;이선형;양재호;정헌영
    • 대한치과보철학회지
    • /
    • 제37권2호
    • /
    • pp.143-166
    • /
    • 1999
  • The success of porcelain laminate veneer depends on the bond strength between tooth structure and ceramic restoration and the design of tooth preparation. In particular, incisal coverage and incisal finish line are the two most important factors in long-term fracture resistance. Although the majority of clinicians are practicing incisal coverage and there are various opinions on the geo-metrical ratio between the clinical crown length of the remaining tooth structure and the length of incisal extension in porcelain laminate veneer and the optimal incisal finish lines. scientific evidence still loaves much to be desired. The purpose of this study was to determine the effects of the amounts of incisal coverage and the types of incisal finish line on the stress distribution in maxillary anterior porcelain laminate veneers under two different loading conditions. Three-dimensional finite element models of a maxillary anterior porcelain veneer with differ-ent amounts of incisal coverage ; 0, 1, 2, and 3mm and different incisal finish lines feathered edge, incisal bevel, reverse bevel and lingual chamfer with various amounts of lingual extension were developed. 300N force was applied at the point 0.5mm cervical of the linguoincisal edge in two loading conditions ; A) 125 degrees, B) 132 degrees. Tensile and compressive stress in ceramic and shear stress in the resin cement layer were analyzed using three-dimensional finite element method. The results were as follows : 1. The types of incisal finish line had more influence on the stress distribution in porcelain laminate veneer than the amounts of incisal coverage. 2. In case of no incisal coverage, incisal beveled laminate exhibited more evenly distributed tensile stress than feathered edged laminate. And in case of incisal coverage, reverse beveled laminate and lingual chamfered laminate with 1mm lingual extension exhibited more evenly distributed tensile stress than lingual chamfered laminates with 2mm and 3mm lingual extension. 3. As long as the lingual chamfer goes, less tensile stress was found at the incisal edge, while much more tensile stress was found at the lingual margin area in proportion to the length of lingual extension. 4. Under 125 degree load, tensile stress in porcelain laminate veneer had increased compared with that under 132 degree load and the difference exhibited by the change of the amount of tooth support was larger. 5. The types of incisal finish line and the distance from the incisal finish line to the loading point had more influence on the shear stress distribution in the resin cement layer than the amounts of incisal coverage. In contrast loading condition had little influence.

  • PDF

동축전송선로에 연결된 도파관형 소자의 입력 임피던스 해석 (Input impedance analysis of the coaxial to W/G type devices)

  • 이평화;천창율;신판석
    • 전자공학회논문지D
    • /
    • 제34D권11호
    • /
    • pp.9-19
    • /
    • 1997
  • By noticing that most waveguide devices were connected to power source through coaxial line, three dimentional finite element analysis using TEM mode incident was tried. When tEM mode was used, being dissimilar to TE$_{10}$ mode incident, analysis model of TEM mode incident has almost the same geometry with real products. Therefore, the degree of trust about analysis result is improved. Reflection coefficients of coaxial line, W/G adaptor, magnetron obtained by simulation was compared with experimental results.

  • PDF

X-밴드 magnetically tunable E-평면형 도파관 여파기 설계 (A design of magnetically tunable X-band E-plane waveguide filters)

  • 이해선;윤상원;장익수
    • 전자공학회논문지D
    • /
    • 제35D권1호
    • /
    • pp.16-26
    • /
    • 1998
  • This paper presents a design methodology for magnetically tunable X-band E-plane type waveguide filters. The proposed design is based on using of quarter wavelength transmission line for compensating the negative length transmission line of end K-inverters of E-plane type waveguide filters. The derived formulae are applied for initial design and the correction method is also provided for final design by considering the frequency dependent characteristic of K-inverters. The analysis results of E-plane pype waveguide structure loaded with ferrite slab are obtained using the edge based finite element method including higher order mode effecets. It is shown that the unilateral finline E-plane type waveguide filter as well as the bilateral finline E-plane type waveguide filter achieves the the manetically tunable characteristic. The X-band experimantal results for bilateral and unilateral finline E-plane type waveguide filters agree well with the simulated data.

  • PDF

하악각 골절의 치료 방법에 따른 하악골의 응력 분포 및 변위에 관한 삼차원 유한요소법적 연구 (THE THREE DIMENSIONAL FINITE ELEMENT ANALYSIS OF STRESS DISTRIBUTION AND DISPLACEMENT IN MANDIBLE ACCORDING TO TREATMENT MODALITIES OF MANDIBULAR ANGLE FRACTURES)

  • 구제훈;김일규;장재원;양정은;사시카라 바라라만;왕붕
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제32권3호
    • /
    • pp.207-217
    • /
    • 2010
  • The purpose of this study was to evaluate the effects of the stress distribution and displacement in mandible according to treatment modalities of mandibular angle fractures, using a three dimensional finite element analysis. A mechanical model of an edentulous mandible was generated from 3D scan. A 100-N axial load and four masticatory muscular supporting system were applied to this model. According to the number, location and materials of titanium and biodegradable polymer plates, the experimental groups were divided into five types. Type I had a single titanium plate in the superior border of mandibular angle, type II had two titanium plates in the superior tension border and in the inferior compression border of mandibular angle, type III had a single titanium plate in the ventral area of mandibular angle, type IV had a single biodegradable polymer plate in the superior border of mandibular angle, type V had a single biodegradable polymer plate in the ventral area of mandibular angle. The results obtained from this study were follows: 1. Stress was concentrated on the condylar neck of the fractured side except Type III. 2. The values of von-Mises stress of the screws were the highest in the just-posterior screw of the fracture line, and in the just-anterior screw of Type III. 3. The displacement of mandible in Type III was 0.04 mm, and in Type I, II, IV, and V were 0.10 mm. 4. The plates were the most stable in the ventral area of mandibular angle (Type III, V). In conclusion, the ventral area of mandibular angle is the most stable location in the fixation of mandibular angle fractures, and the just- posterior and/or the just-anterior screws of the fracture line must be longer than the other, and surgeons have to fix accurately these screws, and the biodegradable polymer plate also was suitable for the treatment of mandible angle fracture.

켄치 상태에서 고온 초전도 한류기의 전자기적 거동 (Electromagnetic Behavior of High-Tc Superconducting Fault Current Limiters under the Quench State)

  • Hyo-Sang Choi
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제53권1호
    • /
    • pp.38-42
    • /
    • 2004
  • In this paper we analyzed the electromagnetic behavior of a superconducting fault current limiter (SFCL) under the quench state using FEM. The analysis model used in this work is 5.5 KVA meander-line type SFCLs which are currently developed by Superconductor Power System Lab in Korea Electric Power Research Institute. Meshes of 3,650 triangular elements were used in the analysis of this SFCL. Analysis results showed that the distribution of current density was concentrated to inner curved line in meander-line type SFCL and the maximum current density was 14.61 A/$m^2$ and also the maximum Joule heat was 2,030 W/$m^2$ in this region. We think that the new and the modified structure must be considered for an uniform distribution of the electromagnetic field.

Vacuum Interrupter 내부 End_shield가 전계분포에 미치는 영향 (The influence that cup-type shield inner vacuum interrupter causes to electric field distribution)

  • 윤재훈;김병철;허준;임기조;강성화
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2008년도 하계학술대회 논문집 Vol.9
    • /
    • pp.478-479
    • /
    • 2008
  • this paper describes the electric field distribution interpretation along a shield form inner vacuum interrupter(VI). The equipotential line and electric field and field vector in a VI are analysed by a finite element method at various shield form. in result, The equipotential line and electric field distribution was affected to VI shield form. The reason is as it gets distortion of equipotential line done. shield of cup type is how to electric field distribution, finally, this paper recognized whether or not affected, and proposed gap with the most suitable shield length and an external insulation.

  • PDF

Behavior of reinforced lightweight aggregate concrete hollow-core slabs

  • Al-Azzawi, Adel A.;Al-Aziz, Basma M. Abdul
    • Computers and Concrete
    • /
    • 제21권2호
    • /
    • pp.117-126
    • /
    • 2018
  • This research investigate the behavior of reinforced normal and lightweight aggregate concrete hollow core slabs with different core shapes, shear span to effective depth (a/d). The experimental work includes testing seven reinforced concrete slabs under two vertical line loads. The dimensions of slab specimens were (1.1 m) length, (0.6 m) width and (0.12 m) thickness. The maximum reduction in weight due to aggregate type was (19.28%) and due to cross section (square and circular) cores was (17.37 and 13.64%) respectively. The test results showed that the decrease of shear span to effective depth ratio from 2.9 to 1.9 for lightweight aggregate solid slab cause an increase in ultimate load by (29.06%) and increase in the deflection value at ultimate load or the ultimate deflection by (17.79%). The use of lightweight aggregate concrete in casting solid slabs give a reduction in weight by (19.28%) and in the first cracking and ultimate loads by (16.37%) and (5%) respectively for constant (a/d=2.9).The use of lightweight aggregate concrete in casting hollow circular core slabs with constant (a/d=2.9) (reduction in weight 32.92%) decrease the cracking and ultimate loads by (12%) and (5.18%) respectively with respect to the solid slab. These slab specimens were analyzed numerically by using the finite element computer program ANSYS. Good agreements in terms of behavior, cracking load (load at first visible crack) and ultimate load (maximum value of testing load) was obtained between finite element analysis and experimental test results.