• 제목/요약/키워드: Line-to-ground

검색결과 1,464건 처리시간 0.035초

Characteristics of the SFCL by turn-ratio of three-phase transformer

  • Jeong, I.S.;Choi, H.S.;Jung, B.I.
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제15권4호
    • /
    • pp.34-38
    • /
    • 2013
  • According to the increase of electric consumption nowadays, power system becomes complicated. Due to this, the size of single line-to-ground fault from power system also increases to have many problems. In order to resolve these problems effectively, an Superconducting Fault Current Limiter(SFCL) was proposed and continuous study has been done. In this paper, an SFCL was combined to the neutral line of a transformer. An superconductivity has the characteristics of zero resistance below critical temperature. because of this, SFCL has nearly zero resistance. so we connecting SFCL to neutral line will not only have any loss in the normal operation but also have the less burden of electric power because of only limiting the initial fault current. We analyzed the characteristics of current, voltage according to the changes of turn ratio of 3 phase system in case of combinations of an SFCL to the neutral line. It was confirmed that the limiting rate of initial fault current by the increase of turn ratio was reduced.

삼상전력계통의 비대칭고장전류 저감을 위한 초전도한류기의 전류제한특성 (Current Limiting Characteristics of Superconducting Fault Current Limiter for Reduction of Unsymmetrical Fault Current in a Three-Phase Power System)

  • 김영민;임성훈;황종선
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2010년도 춘계학술대회 논문집
    • /
    • pp.8-8
    • /
    • 2010
  • In this paper, the limiting characteristics of the fault current in a power system with a superconducting fault current limiter(SFCL) applied into neutral line of main transformer in a distribution power line were analyzed. The SFCL applied into the neutral line of main transformer power system can limit the unsymmetrical fault current from the single-line ground fault or the double-line ground fault. In addition, it could be decreased a number of SFCL and a load. This method could be expected to reduction of a power loss in the neutral line, because of a neutral line current is zero in ordinary times.

  • PDF

Simulation for current limiting characteristics of the resistive and inductive SFCL with line-to-ground fault

  • Choi, Hyo-Sang;Hwang, Si-Dole;Kim, Sang-Joon;Han, Byoung-Sung
    • Progress in Superconductivity
    • /
    • 제1권1호
    • /
    • pp.73-80
    • /
    • 1999
  • We investigated the current limiting characteristics of resistive and inductive SFCLs with 100 $\Omega$ of impedance for line-to-ground faults in the 154 kV transmission system. The fault simulation at the phase angles $0^{\circ}$, $^45{\circ}$, and $90^{\circ}$ showed that the resistive SFCL limits the fault current less than 17 kA without any DC component after one half cycle from the instant of the fault. On the other hand, the inductive SFCL suppresses the current below 14 kA, but with 5 kA of DC component which decreases to zero in 5 cycles. We concluded that the inductive SFCL has higher performance in current limiting effect, but the resistive SFCL was better from the viewpoint of less DC components.

  • PDF

공통 결함접지구조를 이용한 링 하이브리드 커플러의 소형화 설계 (Design of Size-reduced Ring Hybrid Couplers Using a Common Defected Ground Structure)

  • 임종식;이준;권경훈;정용채;한상민;안달
    • 전기학회논문지
    • /
    • 제61권11호
    • /
    • pp.1662-1667
    • /
    • 2012
  • This paper describes the design of size-reduced ring hybrid couplers (RHC) using a common defected ground structure (CDGS). The proposed RHC consists of double-sided microstrip line and the CDGS patterns which are placed in the common ground plane of the double-sided microstrip line. The effects of DGS as a periodic structure are imposed on both microstrip lines, so the advantages of the existing DGS are doubled. The normal RHC is designed first and folded by the half reference plane with the CDGS realized on the common ground plane. So another trial for size-reduction is performed by folding the RHC and inserting CDGS besides to the conventional DGS. In order to show a design example, a 2GHz RHC is designed and miniaturized using CDGS. The size of the miniaturized RHS is around 50% of the normal one, while the performances are well preserved even after the size-reduction.

전위강하법에 의한 접지저항측정에 미치는 전위보조전극 위치의 영향 (Effects of the Position of Potential Probe on Ground Resistance Measurements Using the Fall-of-Potential Method)

  • 이복희;어주홍;김성원
    • 조명전기설비학회논문지
    • /
    • 제15권2호
    • /
    • pp.97-104
    • /
    • 2001
  • 본 논문에서는 전위강하법에 의한 접지저항 측정시 전위보조전극 위치의 영향에 대하여 기술하였다. 전위강하법에서 접지저항은 이론적으로 전위보조전극을 피측정 접지전극과 전류보조전극이 이루는 일직선상에 위치시킬때 61.8[%]법칙을 적용하여 측정한다. 하지만 측정현장의 사정상 전위보조전극의 위치를 피측정 접지전극과 전류 보조전극이 이루는 일직선과 어느 정도의 각도를 가지도록 시설하여 접지저항을 측정하게 될 경우에 측정오차가 발생하게 되고 보정이 필요하다. 본 연구에서의 측정대상 전극은 길이 2.4 [m]의 봉형 접지전극으로 하였으며, 피측정 접지전극, 전위보조전극, 전류보조전극이 일직선상에 놓이지 않은 상태에서 접지저항을 측정하면 측정값은 항상 (-)의 오차를 나타내었고, 이들 전극이 이루는 각도가 증가함에 따라 측정 오차도 증가하였다.

  • PDF

Si RFIC상에서 주기적 구조를 이용한 코프레너형 전송선로의 기본특성연구 (A Study on Basic Characteristics of a Coplanar-type Transmission Line Employing Periodic Structure on Si RFIC)

  • 조한나;박영배;윤영
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제32권6호
    • /
    • pp.964-973
    • /
    • 2008
  • In this study, a short-wavelength coplanar-type transmission line employing periodic ground structure (PGS) was developed for application to miniaturized on-chip passive component on Si Radio Frequency Integrated Circuit (RFIC). The transmission line employing PGS showed shorter wavelength and lower characteristic impedance than conventional coplanar-type transmission line. The wavelength of the transmission line employing PGS structure was 57 % of the conventional coplanar-type transmission line on Si substrate. Using the theoretical analysis. basic characteristics of the transmission line employing PGS (e.g., bandwidth. loss, impedance, and resonance characteristics) were also investigated in order to evaluate its suitability for application to a development of miniaturized passive on-chip components on silicon RFIC. According to the results. the bandwidth of the transmission line employing PGS was more than 895 GHz as long as T is less than 20${\mu}m$, and the resonance characteristic was observed in 1239 GHz, which indicates that the PPGM structure is a promising candidate for application to a development of miniaturized on-chip passive components on Si RFIC.

웨이브렛 변환을 이용한 철도 고압배전선로의 고장검출기법 (Fault Detection Technique in Railway High Voltage Distribution Lines using Wavelet Transform)

  • 정호성;한문섭;이장무;김주락;이한민
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2004년도 춘계학술대회 논문집
    • /
    • pp.1274-1279
    • /
    • 2004
  • This paper proposes technique to detect ground fault in railway high voltage distribution lines. Overcurrent relay technique is widely used for detecting one line ground fault that occurs most frequently in railway high voltage distribution lines. However, ground fault in distribution line is usually high impedance fault with arc. Because the fault current magnitude measured in substation is very small, the conventional overcurrent relay can't detect the high impedance ground fault. Therefore this paper proposes the advanced technique using wavelet transform. It extracts D1 component from fault signals and detects fault comparing magnitude of D1 component in each phase. To evaluate this proposed technique, we model distribution system using PSCAD/EMTDC and extract various fault data. In conclusion this technique can detect ground fault including high impedance fault regardless of fault distance, fault impedance etc.

  • PDF

22.9kV다중접지선로 지락고장점 대지유입전류 및 중성선분류 해석 (An analysis of The ground fault current Distribution of 22.9kV-Y Lines)

  • 임용훈;현덕화;최종기
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 A
    • /
    • pp.473-475
    • /
    • 2004
  • During ground faults in power system, large current and raised potential appear at nearby places. This paper presents an analytical procedure of the ground fault current for the towers of a transmission line(154kV) and distribution line(22.9kV) of an arbitrary number of spans during ground faults. In order to economically and securely protect against undesired consequences, it is necessary to evaluate as precisely as possible the value and distribution of the ground fault current.

  • PDF

Development of a Measuring Instrument of Current and Voltage on Power-Transmission Lines for the Construction of Energy-Network

  • Park, Kyi-Hwan;Jiang, Zhongwei
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2001년도 ICCAS
    • /
    • pp.107.2-107
    • /
    • 2001
  • We propose portable equipment that monitors a current and potential on high-potential power transmission lines. In the equipment, a current and voltage sensor are attached to a hollow insulator that supports a power transmission line: A current on a power line is detected by an air-core solenoidal coil clamped to the line and the detected current signal is transmitted to the ground station by using optical data link, A potential on a power transmission line is detected by a high resistance element, zinc oxide (ZnO) that acts as a potential divider between the power line and the ground. The equipment does not require high potential insulators and magnetic cores which. This leads to the following advantages of the equipment: (a) It is easily installed owing to its small size and its simple structure; (b) It operates in low ...

  • PDF

현장계측 및 시뮬레이션 조합에 의한 철도지반진동예측기법 개발 (Ground vibration predictions based on the combination of measurements and simulations)

  • 양신추;황성호;장승엽;김은
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2014년도 춘계학술대회 논문집
    • /
    • pp.366-370
    • /
    • 2014
  • Considering a countermeasure against vibration along the existing line, in many cases, it may be the most efficient method to replace existing fasteners with high resilient fasteners because of the restriction of the construction of a new track type. There are many types of high resilient fasteners which are different in price and performance. Therefore it is important to choose the high resilient fastener which has best vibration-proof performance per price. In this study, a prediction method which can exactly evaluate the performance of a fastener in the reduction the ground borne noise in the existing line is presented, which is constructed based on the combination of the measurement and the simulation. A numerical example using the presented method is introduced to evaluate the vibration-proof performance for the solution of the vibration problem in the existing line.

  • PDF