• 제목/요약/키워드: Line-scan imaging

검색결과 42건 처리시간 0.019초

A Simple Multispectral Imaging Algorithm for Detection of Defects on Red Delicious Apples

  • Lee, Hoyoung;Yang, Chun-Chieh;Kim, Moon S.;Lim, Jongguk;Cho, Byoung-Kwan;Lefcourt, Alan;Chao, Kuanglin;Everard, Colm D.
    • Journal of Biosystems Engineering
    • /
    • 제39권2호
    • /
    • pp.142-149
    • /
    • 2014
  • Purpose: A multispectral algorithm for detection and differentiation of defective (defects on apple skin) and normal Red Delicious apples was developed from analysis of a series of hyperspectral line-scan images. Methods: A fast line-scan hyperspectral imaging system mounted on a conventional apple sorting machine was used to capture hyperspectral images of apples moving approximately 4 apples per second on a conveyor belt. The detection algorithm included an apple segmentation method and a threshold function, and was developed using three wavebands at 676 nm, 714 nm and 779 nm. The algorithm was executed on line-by-line image analysis, simulating online real-time line-scan imaging inspection during fruit processing. Results: The rapid multispectral algorithm detected over 95% of defective apples and 91% of normal apples investigated. Conclusions: The multispectral defect detection algorithm can potentially be used in commercial apple processing lines.

저자장 자기공명영상시스템에서 선주사확산강조영상기법 개발 (Development of the Line Scan Diffusion Weighted Imaging at Low Tesla Magnetic Resonance Imaging System)

  • 홍철표;이동훈;이도완;이만우;백문영;한봉수
    • 한국방사선학회논문지
    • /
    • 제2권2호
    • /
    • pp.31-38
    • /
    • 2008
  • 0.32 T 자기공명영상시스템에서 선주사영상기법(line scan imaging)을 이용한 확산강조영상(diffusion weighted imaging; DWI) 펄스열(pulse sequence)을 개발하였다. 선주사영상은 단면선택 경사자장과 함께 90도 펄스를 가하여 단면을 선택한 후 y 방향으로 경사자장을 가한 후 180도 라디오파 펄스를 가하여 단면영상의 y-방향 픽셀크기와 같은 너비의 x축에 평행한 띠를 따라 에코가 발생하게 한 뒤 x-방향으로 주파수부호화해서 1차원 k-공간 데이터를 획득하며 이를 1차원 푸리에변환하여 영상을 재구성하였다. 또한 선주사확산강조영상(line scan diffusion weighted image)을 위해서 한 쌍의 사다리꼴모양의 경사자장을 선주사영상기법의 180도 펄스 전후에 대칭으로 배치하였으며 사용된 확산경사자장기울기의 최대값은 G = 15 mT/m 이었고 최대 b 값은 $301.50s/mm^2$이었다. 본 연구에서 개발된 선주사확산강조펄스열을 이용하여 0.32 T 자기공명영상 장비에서 트리아실글리세롤 팬텀(triacylglycerol, TAG) 및 염화나트륨 수용액 (NaCl = 0.1w/v%) 팬텀 영상을 획득하였다. 또한 1.5 T 자기공명영상시스템에서 단일여기에코평면영상화(single shot echo planar imaging)로 동일한 팬텀의 확산강조영상을 구하였다. 선주사확산강조영상은 가장 널리 이용되고 있는 에코평면영상을 이용한 확산강조영상과 비교하여 자화율차이에 의한 영상왜곡이나 화학이동에 의한 허상들이 없음을 확인하였다. 특히 선주사확산강조영상에서 측정한 염화나트륨 수용액 팬텀의 확산계수($963.90{\pm}79.83{\times}10^{-6}mm^2/s$)는 1.5 T에서 계산된 확산계수($956.77{\pm}4.12{\times}10^{-6}mm^2/s$)와 오차범위 내에서 일치하였다.

  • PDF

Raman Chemical Imaging Technology for Food and Agricultural Applications

  • Qin, Jianwei;Kim, Moon S.;Chao, Kuanglin;Cho, Byoung-Kwan
    • Journal of Biosystems Engineering
    • /
    • 제42권3호
    • /
    • pp.170-189
    • /
    • 2017
  • Purpose: This paper presents Raman chemical imaging technology for inspecting food and agricultural products. Methods The paper puts emphasis on introducing and demonstrating Raman imaging techniques for practical uses in food analysis. Results & Conclusions: The main topics include Raman scattering principles, Raman spectroscopy measurement techniques (e.g., backscattering Raman spectroscopy, transmission Raman spectroscopy, and spatially offset Raman spectroscopy), Raman image acquisition methods (i.e., point-scan, line-scan, and area-scan methods), Raman imaging instruments (e.g., excitation sources, wavelength separation devices, detectors, imaging systems, and calibration methods), and Raman image processing and analysis techniques (e.g., fluorescence correction, mixture analysis, target identification, spatial mapping, and quantitative analysis). Raman chemical imaging applications for food safety and quality evaluation are also reviewed.

The Standard Processing of a Time Series of Imaging Spectral Data Taken by the Fast Imaging Solar Spectrograph on the Goode Solar Telescope

  • Chae, Jongchul;Kang, Juhyeong;Cho, Kyuhyoun
    • 천문학회보
    • /
    • 제43권2호
    • /
    • pp.46.1-46.1
    • /
    • 2018
  • The Fast Imaging Solar Spectrograph (FISS) on the Goode Solar Telescope (GST) at Big Bear Solar Observatory is the imaging Echelle spectrograph developed by the Solar Astronomy Group of Seoul National University and the Solar and Space Weather Group of Korea Astronomy and Space Science Institute. The instrument takes spectral data from a region on the Sun in two spectral bands simultaneously. The imaging is done by the organization of intensity data obtained from the fast raster scan of the slit over the field of view. Since the scan repeats many times, the whole set of data can be used to construct the movies of monochromatic intensity at arbitrary wavelengths within the spectral bands, and those of line-of-sight velocity inferred from different spectral lines. So far there are two standard observing configurations: one recording the $H{\alpha}$ line and the Ca II 8542 line simultaneously, and the other recording the Na I D2 line and Fe I 5435 line simultaneously. We have developed the procedures to produce the standard data for each observing configuration. The procedures include the spatial alignment, the correction of spectral shift of instrumental origin, and the lambdameter measurement of the line wavelength. The standard data include the movie of continuum intensity, the movies of intensity and velocity inferred from a chromospheric spectral line, the movies of intensity and velocity inferred from a photospheric line. The processed standard data will be freely available online (fiss.snu.ac.kr) to be used for research and public outreach. Moreover, the IDL procedures will be provided on request as well so that each researcher can adapt the programs for their own research.

  • PDF

Nondestructive sensing technologies for food safety

  • Kim, M.S.;Chao, K.;Chan, D.E.;Jun, W.;Lee, K.;Kang, S.;Yang, C.C.;Lefcourt, A.M.
    • 한국환경농학회:학술대회논문집
    • /
    • 한국환경농학회 2009년도 정기총회 및 국제심포지엄
    • /
    • pp.119-126
    • /
    • 2009
  • In recent years, research at the Environmental Microbial and Food Safety Laboratory (EMFSL), Agricultural Research Service (ARS) has focused on the development of novel image-based sensing technologies to address agro-food safety concerns, and transformation of these novel technologies into practical instrumentation for industrial implementations. The line-scan-based hyperspectral imaging techniques have often served as a research tool to develop rapid multispectral methods based on only a few spectral bands for rapid online applications. We developed a newer line-scan hyperspectral imaging platform for high-speed inspection on high-throughput processing lines, capable of simultaneous multiple inspection algorithms for different agro-food safety problems such as poultry carcass inspection for wholesomeness and apple inspection for fecal contamination and defect detection. In addition, portable imaging devices were developed for in situ identification of contamination sites and for use by agrofood producer and processor operations for cleaning and sanitation inspection of food processing surfaces. The aim of this presentation is to illustrate recent advances in the above agro.food safety sensing technologies.

  • PDF

라인스캔 카메라를 이용한 3차원 정밀 측정 (3D Precision Measurement of Scanning Moire Using Line Scan Camera)

  • 김현주;윤두현;김학일
    • 한국광학회지
    • /
    • 제19권5호
    • /
    • pp.376-380
    • /
    • 2008
  • 본 논문에서는 라인스캔 카메라를 통해 모든 영역의 영상을 획득하는 연구를 제안한다. 이 방법은 기존의 면적 카메라를 이용했던 방법에 비해 투영격자의 이동 횟수를 획기적으로 줄일 수 있으며, 그로 인해 측정시간이 매우 빠르고 측정정밀도도 뛰어난 장점을 가진다. 본 논문의 스캐닝 모아레 측정 방법은 넓은 영역의 3차원 형상 정보를 얻는데 매우 유익하며, 대면적의 대상물 측정 시 일반적으로 사용하는 stitching 기법을 사용할 필요가 없으므로 한번에 전 영역의 3차원 형상의 복원이 가능하여 보다 빠른 속도로 3차원 형상 정보를 얻을 수 있는 효과가 있다. 또한, 투영격자 하나만을 이용한 영사식 모아레 방식을 이용하여 작은 높이 단차를 갖는 물체의 3차원 형상을 복원하고 그 높이를 용이하게 측정 할 수 있다. 본 연구는 양산환경(Mass production)의 웨이퍼 범프 높이 검사 및 FC-CSP나 FC-BGA 범프 높이 검사 등에 활용 할 수 있으며, 실험을 통해 기존의 방법에 비해 투영격자의 이동횟수 및 측정 속도가 향상되었음을 확인하였다.

초음파 섹터 스캐너를 위한 디지털 스캔 변환 기법 (Digital Scan Converter Algorithm for Ultrsound Sector Scanner)

  • 김근호;오정환
    • 대한의용생체공학회:의공학회지
    • /
    • 제17권4호
    • /
    • pp.469-478
    • /
    • 1996
  • In the conventional digital ultrasound scanner, the reflected signal is sampled either in polar coordinates of R-$\theta$ method, or in Cartesian coordinates of uniform ladder algorithm (ULA). The R-$\theta$ scan method necessitates a coordinate transform process which makes hardware complex in comparison with ULA scan mrthoA In spite of this complexity, R-$\theta$ method has a good resolution in ultrasonographic (US) image, since scan direction of the US imaging is a radial direction. In this paper, a new digital scan converter is proposed, which is named the radius uniform ladder algorithm (RULA). The RULA has the rome scan direction as the US scanning in the radial direction and as the display space in the $\theta$ direction. In tllis new approach, sampled points we uniformly distributed in each horizontal line i.n well as in each radial ray so that the data are displayed in the Cartesian coordinates by the 1-D interpolation process. The propped algorithm has an uniform resolution in the periphery and the center field in comparison with equi-angle ULA and equi-interval ULA. To extend the scan angle, concentric square raster sampling (CSRS) is adopted with reduction of discontinuities on the junctions between horizontal scan and vertical scan. The discontinuities are reduced by using the hmction filtering along the $\theta$ direction.

  • PDF

복합 [$90^{\circ}-{\tau}-180^{\circ}-2{\tau}-180^{\circ}-{\tau}$ 시이퀸스를 이용한 핵자기 공명 혈관 조영술 (MR ANGIOGRAPHY USING THE COMPOSITE [$90^{\circ}-{\tau}-180^{\circ}-2{\tau}-180^{\circ}-{\tau}$] SEQUENCE)

  • 김재호;이기동;전현호;조장희
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1989년도 춘계학술대회
    • /
    • pp.35-37
    • /
    • 1989
  • A new MR angiography technique using a composite sequence for the suppression of static sample signals is proposed and verified with experiments. When the composite [$90^{\circ}-{\tau}-180^{\circ}-2{\tau}-180^{\circ}-{\tau}$] sequence is applied, the large signal from the static sample is sufficiently suppressed but the signal from fresh inflow sample of which amplitude. is observed without suppression. These properties are appropriate for angiographic applications. In this paper, a modified line scan method (Block line scan angiography) incorporated with the composite [$90^{\circ}-{\tau}-180^{\circ}-2{\tau}-180^{\circ}-{\tau}$] sequence is used to obtain flow-only images, i.e., angiograms. The block line scan method improves the resolution in the flow-direction at the expense of imaging time. With the composite sequence, there is no need for subtraction procedure as in the most conventional angiographic methods. Experimental results for a phantom and a normal volunteer with KAIS 2.0 Tesla MRI system are shown.

  • PDF

COMPARISON OF LOS DOPPLER VELOCITIES AND NON-THERMAL LINE WIDTHS IN THE OFF-LIMB SOLAR CORONA MEASURED SIMULTANEOUSLY BY COMP AND HINODE/EIS

  • Lee, Jae-Ok;Lee, Kyoung-Sun;Seough, Jungjoon;Cho, Kyung-Suk
    • 천문학회지
    • /
    • 제54권2호
    • /
    • pp.49-60
    • /
    • 2021
  • Observations of line of sight (LOS) Doppler velocity and non-thermal line width in the off-limb solar corona are often used for investigating the Alfvén wave signatures in the corona. In this study, we compare LOS Doppler velocities and non-thermal line widths obtained simultaneously from two different instruments, Coronal Multichannel Polarimeter (CoMP) and Hinode/EUV Imaging Spectrometer (EIS), on various off-limb coronal regions: flaring and quiescent active regions, equatorial quiet region, and polar prominence and plume regions observed in 2012-2014. CoMP provides the polarization at the Fe xiii 10747 Å coronal forbidden lines which allows their spectral line intensity, LOS Doppler velocity, and line width to be measured with a low spectral resolution of 1.2 Å in 2-D off limb corona between 1.05 and 1.40 RSun, while Hinode/EIS gives us the EUV spectral information with a high spectral resolution (0.025 Å) in a limited field of view raster scan. In order to compare them, we make pseudo raster scan CoMP maps using information of each EIS scan slit time and position. We compare the CoMP and EIS spectroscopic maps by visual inspection, and examine their pixel to pixel correlations and percentages of pixel numbers satisfying the condition that the differences between CoMP and EIS spectroscopic quantities are within the EIS measurement accuracy: ±3 km s-1 for LOS Doppler velocity and ±9 km s-1 for non-thermal width. The main results are summarized as follows. By comparing CoMP and EIS Doppler velocity distributions, we find that they are consistent with each other overall in the active regions and equatorial quiet region (0.25 ≤ CC ≤ 0.7), while they are partially similar to each other in the overlying loops of prominences and near the bottom of the polar plume (0.02 ≤ CC ≤ 0.18). CoMP Doppler velocities are consistent with the EIS ones within the EIS measurement accuracy in most regions (≥ 87% of pixels) except for the polar region (45% of pixels). We find that CoMP and EIS non-thermal width distributions are similar overall in the active regions (0.06 ≤ CC ≤ 0.61), while they seem to be different in the others (-0.1 ≤ CC ≤ 0.00). CoMP non-thermal widths are similar to EIS ones within the EIS measurement accuracy in a quiescent active region (79% of pixels), while they do not match in the other regions (≤ 61% of pixels); the CoMP observations tend to underestimate the widths by about 20% to 40% compared to the EIS ones. Our results demonstrate that CoMP observations can provide reliable 2-D LOS Doppler velocity distributions on active regions and might provide their non-thermal width distributions.

A New True Ortho-photo Generation Algorithm for High Resolution Satellite Imagery

  • Bang, Ki-In;Kim, Chang-Jae
    • 대한원격탐사학회지
    • /
    • 제26권3호
    • /
    • pp.347-359
    • /
    • 2010
  • Ortho-photos provide valuable spatial and spectral information for various Geographic Information System (GIS) and mapping applications. The absence of relief displacement and the uniform scale in ortho-photos enable interested users to measure distances, compute areas, derive geographic locations, and quantify changes. Differential rectification has traditionally been used for ortho-photo generation. However, differential rectification produces serious problems (in the form of ghost images) when dealing with large scale imagery over urban areas. To avoid these artifacts, true ortho-photo generation techniques have been devised to remove ghost images through visibility analysis and occlusion detection. So far, the Z-buffer method has been one of the most popular methods for true ortho-photo generation. However, it is quite sensitive to the relationship between the cell size of the Digital Surface Model (DSM) and the Ground Sampling Distance (GSD) of the imaging sensor. Another critical issue of true ortho-photo generation using high resolution satellite imagery is the scan line search. In other words, the perspective center corresponding to each ground point should be identified since we are dealing with a line camera. This paper introduces alternative methodology for true ortho-photo generation that circumvents the drawbacks of the Z-buffer technique and the existing scan line search methods. The experiments using real data are carried out while comparing the performance of the proposed and the existing methods through qualitative and quantitative evaluations and computational efficiency. The experimental analysis proved that the proposed method provided the best success ratio of the occlusion detection and had reasonable processing time compared to all other true ortho-photo generation methods tested in this paper.