• Title/Summary/Keyword: Line-scan

Search Result 471, Processing Time 0.031 seconds

A Virtual Fitting System Using The Top and Bottom Image of Garment (상하의 의류 영상을 이용한 가상 의류 착의 시스템)

  • Choi, Ran;Cho, Chang-Suk
    • Journal of Korea Multimedia Society
    • /
    • v.15 no.7
    • /
    • pp.941-950
    • /
    • 2012
  • A virtual garment fitting system which fits the top and bottom of a garment on 3D body data is introduced. This system uses the laser scanned 3D body data and the digital images photographed the front and back of a garment. The digital images are modeled to reflect tensions among particles in the images and the friction and gravity effects are considered in the fitting process to the body data. When a bottom is fitted, a virtual belt to hold the bottom in the waist is introduced since gravity effects pull down it. Also the process for fitting the top and bottom on layers is proposed here. The system has the strengths that it uses only the front and back image of a garment instead of using complicated patterns of a garment, and provides a realistic fit result as a 3D figure. As on-line retailing shop in present displays front and back images of garments, this system also does. However this system provides a differentiated service to user than present retailing shop as showing a 3D fit image. It will make a new trend in online shop retailing of garment.

Fusarium mangiferae as New Cell Factories for Producing Silver Nanoparticles

  • Hamzah, Haider M.;Salah, Reyam F.;Maroof, Mohammed N.
    • Journal of Microbiology and Biotechnology
    • /
    • v.28 no.10
    • /
    • pp.1654-1663
    • /
    • 2018
  • Finding a safe and broad-spectrum medication is a goal of scientists, pharmacists, and physicians, but developing and fabricating the right medicine can be challenging. The current study describes the formation of silver nanoparticles (AgNPs) by Fusarium mangiferae. It involves the antibiofilm activity of the nanoparticles against Staphylococcus aureus. It also involves cytotoxic effect against mammalian cell lines. Well-dispersed nanoparticles are formed by F. mangiferae. The sizes of the nanoparticles were found to range from 25 to 52 nm, and UV-Vis scan showed absorption around 416-420 nm. SEM, TEM, and AFM results displayed spherical and oval shapes. Furthermore, the FTIR histogram detected amide I and amide II compounds responsible for the stability of AgNPs in an aqueous solution. AgNPs were observed to decrease the formation of biofilm at 75% (v/v). DNA reducing, smearing, and perhaps fragmentation were noticed after treating the bacterial cells with 50% (v/v). Additionally, cell lysis was detected releasing proteins in the supernatant. It was also observed that the AgNPs have the ability to cause 59% cervical cancer cell line (HeLa) deaths at 25% (v/v), however, they showed about 31% toxicity against rat embryo fibroblast transformed cell lines (REF). The results of this study prove the efficiency of AgNPs as an antibiofilm against S. aureus, suggesting that AgNPs could be an alternative to antibiotics. It must also be emphasized that AgNPs displayed cytotoxic behavior against mammalian cell lines. Further studies are needed for assessing risk in relation to the possible benefit of prescribing AgNPs.

Study of the Length of Needle Thoracostomy Catheter Needed for Patients with Chest Trauma (흉부 외상 환자에서 늑막 천자를 위해 바늘 도관의 길이에 대한 연구)

  • Kang, Sung Won;Ryoo, Hyun Wook;Park, Jung Bae;Seo, Kang Suk;Chung, Jae Myung
    • Journal of Trauma and Injury
    • /
    • v.22 no.1
    • /
    • pp.1-4
    • /
    • 2009
  • Purpose: This study was conducted to evaluate the length of the catheter used in a needle thoracostomy for emergency decompression of a tension pneumothorax by measuring the chest wall thickness (CWT) in patients with chest trauma Methods: A retrospective review of 201 patients with chest trauma who had been transported the emergency department in a tertiary university hospital in a metropolitan area between 1 January and 31 February 2007 was performed. The average CWT at the second intercostal space (ICS) in the midclavicular line (MCL) was measured by using a chest computed tomography scan. Results: As the left and the right mean CWTs were $3.4{\pm}1.0cm$ and $3.4{\pm}1.0cm$, respectively, there was no significant statistical difference between them. The mean CWT of female patients was significantly higher than that of male patients (p=0.001). The mean CWT of patients under the age of 65 years was significantly thicker than that of the patients over the age of 65 years (p<0.001). Of the studied patients, 12 (6.0%) a CWT > 5 cm. Conclusion: A 5 cm-length catheter in a needle thoracostomy may be insufficient for emergency decompression of a tension pneumothorax, so a catheter longer than 5 cm in length is needed.

Measurements of Two-dimensional Gratings Using a Metrological Atomic Force Microscope with Uncertainty Evaluation

  • Kim, Jong-Ahn;Kim, Jae-Wan;Kang, Chu-Shik;Eom, Tae-Bong
    • International Journal of Precision Engineering and Manufacturing
    • /
    • v.9 no.2
    • /
    • pp.18-22
    • /
    • 2008
  • The pitch and orthogonality of two-dimensional (2-D) gratings were measured using a metrological atomic force microscope (MAFM), and the measurement uncertainty was analyzed. Gratings are typical standard devices for the calibration of precision microscopes, Since the magnification and orthogonality in two perpendicular axes of microscopes can be calibrated simultaneously using 2-D gratings, it is important to certify the pitch and orthogonality of such gratings accurately for nanometrology. In the measurement of 2-D gratings, the MAFM can be used effectively for its nanometric resolution and uncertainty, but a new measurement scheme is required to overcome limitations such as thermal drift and slow scan speed. Two types of 2-D gratings with nominal pitches of 300 and 1000 nm were measured using line scans to determine the pitch measurement in each direction. The expanded uncertainties (k = 2) of the measured pitch values were less than 0.2 and 0.4 nm for each specimen, and the measured orthogonality values were less than $0.09^{\circ}$ and $0.05^{\circ}$, respectively. The experimental results measured using the MAFM and optical diffractometer agreed closely within the expanded uncertainty of the MAFM. We also propose an additional scheme for measuring 2-D gratings to increase the accuracy of calculated peak positions, which will be the subject of future study.

Fatigue Crack Growth Characteristics of 9% Ni Steel Welded Joint for LNG Storage Tank at Low Temperature (LNG 저장탱크용 9% Ni강 용접부의 저온피로균열진전 특성)

  • Kim, Jae-Hoon;Shim, Kyue-Taek;Kim, Young-Kyun;Ahn, Byoung-Wook
    • Journal of Welding and Joining
    • /
    • v.28 no.5
    • /
    • pp.45-50
    • /
    • 2010
  • The fatigue crack growth characteristics of base metal and weld joint of 9% Ni steel for LNG storage tank was carried out using CT specimen at room temperature and $-162^{\circ}C$. Fatigue crack growth rate of base and weld metals at RT and $-162^{\circ}C$ was coincided with a single line independent of the change of stress ratio and temperature. In the region of lower stress intensity factor range, fatigue crack growth rate at $-162^{\circ}C$ was slower than that at RT, and the slop of fatigue crack growth rate at $-162^{\circ}C$ increased sharply with propagating of fatigue crack, fatigue crack growth rate at RT and $-162^{\circ}C$ was intersected near the region of $2{\times}10-4\;mm$/cycle, and after the intersection region, fatigue crack growth rate at $-162^{\circ}C$ was faster than that at RT. The micro-fracture mechanism using SEM shows the ductile striation in the stable crack growth region. Also the defects of weld specimen after fatigue testing were detected using the A scan of ultrasonic apparatus.

Bodice Pattern Development of the Slim-fit Dress Shirt for Middle-aged Males Using 3D Body Scanning Data (3D Body Scanning Data를 활용한 중년 남성용 슬림 핏(Slim-fit) 드레스 셔츠 바디스 패턴개발연구)

  • Suh, Chuyeon
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.40 no.1
    • /
    • pp.171-187
    • /
    • 2016
  • The study performed a comparison analysis of market brand patterns for slim-fit dress shirts and analyzed the body surface development figure of men in their 40s using 3D body scan data and developed slim-fit dress shirt patterns suitable for middle-aged men. The sizes of slim-fit dress shirt patterns showed a slight difference depending on brand. The overlap map of slim-fit dress shirt patterns for brands demonstrates how difference of one-dimensional sizes reflect on two-dimensional patterns. This map provides useful information for pattern design and allows and easy recognition of pattern size differences. A try-on system evaluation through 3D-Simulation allows a grasp of the fitness of neckline and size tolerance of under the arms in front, the silhouette of side lines, and overall fitness in front that also allows analysis of the front/back balance of a shirt in side, the size tolerance proportion in front/back, and the fitness of the arm-hole line. Thus, we obtained try-on results that were equivalent to wearing actual clothing. According to the drafting size suggested in the developed final pattern, the total width was 'C/2+5.5cm', and the front was set at 1cm bigger in the size difference of the front and back. The width of the front neck and the back neck was set identically at 'C/12', while the width of the front neck was set to 'C/12+1.5cm'. For the armhole depth, we added 'C/4+2cm', and '0.5cm and 1.5cm' for the width of the front and back to anthropometry. The results of the try-on evaluation through 3D-Simulation indicated that the fitness of the final slim-fit dress shirt pattern was superior to available slim-fit dress shirt patterns on the market and evaluated as superior to the types for middle-aged men.

Basic Study on the Image Instrument of the Facial-form by the 3D-facial Scanner (얼굴스캐너를 활용한 안면형상 영상진단기의 기초 연구)

  • Kim, Gyeong-Cheol;Lee, Jeong-Won;Kim, Hoon;Shin, Soon-Shik;Lee, Hai-Woong;Lee, Yong-Tae;Chi, Gyoo-Yong;Kim, Jong-Won
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.22 no.2
    • /
    • pp.497-501
    • /
    • 2008
  • 3D facial scanner for an accurate analysis is measured precisely a distance in straight, a distance in curved line, an angle in 3D data, the area of surface. We can easy acquire 3D data by the method of 0.8sec in each scan with easy handling, simple merge to whole face, harmless and fast process. In the HyungSang medicine, the inspection of the facial shape includes the Dam(gall bladder) - Bang Kwang(urinary bladder) body, the Jung${\cdot}$Gi${\cdot}$Shin${\cdot}$Hyul, the six merdian types etc. And we will collect the evidence based date verifing in the HyungSang clinical medicine. As we will analyze the facial whole form and the size${\cdot}$length${\cdot}$angle of the facial part, put the facial form's standardization on a solid foundation.

Brain Injuries during Intraoperative Ventriculostomy in the Aneurysmal Subarachnoid Hemorrhage Patients

  • Moon, Hyung-Ho;Kim, Jae-Hoon;Kang, Hee-In;Moon, Byung-Gwan;Lee, Seung-Jin;Kim, Joo-Seung
    • Journal of Korean Neurosurgical Society
    • /
    • v.46 no.3
    • /
    • pp.215-220
    • /
    • 2009
  • Objective : Intraoperative ventriculostomy is widely adopted to make the slack brain. However, there are few reports about hemorrhagic or parenchymal injuries after ventriculostomy. We tried to analyze and investigate the incidence of these complications in a consecutive series of patients with aneurysmal subarachnoid hemorrhage (SAH). Methods : From September 2006 to June 2007, 43 patients underwent surgical clipping for aneurysmal SAH at our hospital. Among 43 patients, we investigated hemorrhagic or parenchymal injuries after intraoperative ventriculostomy using postoperative computed tomographic scan in 26 patients. After standard pterional craniotomy, ventriculostomy catheter was inserted perpendicular to the cortical surface along the bisectional imaginary line from Paine's point. Results : Hemorrhagic injuries were detected in 12 of 26 patients (46.2%). Mean systolic blood pressure during anesthesia was with in statistically significant parameter related to hemorrhage (p=0.006). On the other hand, parenchymal injuries were detected in 11 of 26 patients (42.3%). Female and the amount of infused mannitol during anesthesia showed statistically significant parameters related to parenchymal injury (p=0.005, 0.04, respectively). However, there were no ventriculostomy-related severe complications. Conclusion : In our series, hemorrhagic or parenchymal injuries after intraoperative ventriculostomy occurred more commonly than previously reported series in aneurysmal SAH patients. Although the clinical outcomes of complications are generally favorable, neurosurgeon must keep in mind the frequent occurrence of brain injury after intraoperative ventriculostomy in the acute stage of aneurysmal SAH.

Conservation of the Metal ball fired by a cannon (창녕 화왕산성 출토 비격진천뢰(飛擊震天雷)의 보존)

  • Gwak, Hongin;Hwang, Jungsoon;Yu, Heisun;Chung, Kwangyong
    • Conservation Science in Museum
    • /
    • v.7
    • /
    • pp.25-31
    • /
    • 2006
  • We performed the conservation treatment for Bigyeokchinjeonnoe (A kind of time bomb in the Joseon Dynasty) excavated from Hwawangsanseong Fortress in Changnyeong-gun, Gyeongsangnam-do Province. Part of the Bigyeokchinjeonnoe has been lost; we did not restore the lost part so that one can observe the inside through it. The results of X-ray investigation and C. T (Computed Tomography) scan proved the generation of many blowholes around the molding line during the casting process; a hole in the casting mold to maintain inner mold during casting was identified on the surface and traces of fortifying this part with iron plate were also identified. The main ingredients of the blue corrosion on the surface were identified as O, Fe, P, Si and Al by SEM/EDS analysis. The result of XRD analysis identified the blue corrosion as vivianite [Fe3(PO4)2·8H2O]. The metal structure clarified its material was gray cast iron.

Use of hybrid materials in the trace determination of As(V) from aqueous solutions: An electrochemical study

  • Tiwari, Diwakar;Jamsheera, A.;Zirlianngura, Zirlianngura;Lee, Seung Mok
    • Environmental Engineering Research
    • /
    • v.22 no.2
    • /
    • pp.186-192
    • /
    • 2017
  • The carbon paste electrode (CPE) was modified with the pristine bentonite and hybrid material (HDTMA-modified bentonite). The modified-CPEs are then employed as working electrode in an electrochemical detection of As(V) from aqueous solutions using the cyclic voltammetric measurements. Cyclic voltammograms revealed that As(V) showed reversible behavior onto the working electrode. The hybrid material-modified carbon paste electrode showed significantly enhanced electrochemical signal which was then utilized in the low level detection of As(V). Moreover, the studies were conducted at neutral pH conditions. The electrochemical studies were conducted with scan rates (20 to 200 mV/s) to deduce the mechanism of redox processes involved at the electrode surface. The anodic current was linearly increased, increasing the concentration of As(V) from 5.0 to $35.0{\mu}g/g$ using the hybrid material-modified electrode. This provided fairly a good calibration line for As(V) detection. The presence of varied concentrations of As(III) in the determination of total arsenic was studied. The influence of several cations and anions viz., Cu(II), Mn(II), Zn(II), Pb(II), Cd(II), Fe(III), $Cl^-$, $NO_3{^-}$, $PO_4{^{3-}}$, EDTA and glycine in the detection of As(V) from aqueous solution was also studied. Further, in an attempt to simulate the real matrix analysis, the tap water sample was spiked with As(V) and subjected for As(V) detection using the modified-CPE.