• Title/Summary/Keyword: Line width reduction

Search Result 51, Processing Time 0.026 seconds

Estimation of Individual Street Trees Using Simulated Airborne LIDAR Data (모의 항공 라이다 자료를 이용한 개별 가로수의 추정)

  • Cho, Du-Young;Kim, Eui-Myoung
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.30 no.3
    • /
    • pp.269-277
    • /
    • 2012
  • Street trees are one of useful urban facilities that reduce carbon dioxide and provide green space in urban areas. They are usually managed by local government, and it is effective to use aerial LIDAR data in order to acquire information such as the location, height and crown width of street tree systematically. In this research, algorithm was proposed that improves the accuracy of extracting top points of street trees and separates the region of individual street trees from aerial LIDAR data. In order to verify the proposed algorithm, a simulated aerial LIDAR data that exactly knows the number, height and crown width of street trees was created. As for the procedure of data processing, filtering that separates ground and non-ground points from LIDAR data was first conducted in order to separate the region of individual street trees. An estimated non-street tree points were then removed from non-ground points, and the top points of street trees were estimated. Region of individual street trees was determined by using the intersecting point of straight line that connects top point and ground point of street tree. Through the experiment by using simulated data, it was possible to refine wrongly estimated points occurred by determining tree tops and to determine the positional information, height, crown width of street trees through the determination of region of street trees.

Low-Power Motion Estimator Architecture for Deep Sub-Micron Multimedia SoC (Deep Submicron 공정의 멀티미디어 SoC를 위한 저전력 움직임 추정기 아키텍쳐)

  • 연규성;전치훈;황태진;이성수;위재경
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.41 no.10
    • /
    • pp.95-104
    • /
    • 2004
  • This paper propose a motion estimator architecture to reduce the power consumption of the most-power-consuming motion estimation method when designing multimedia SoC with deep submicron technologies below 0.13${\mu}{\textrm}{m}$. The proposed architecture considers both dynamic and static power consumption so that it is suitable for large leakage process technologies, while conventional architectures consider only dynamic power consumption. Consequently, it is suitable for mobile information terminals such as mobile videophone where efficient power management is essential. It exploits full search method for simple hardware implementation. It also exploits early break-off method to reduce dynamic power consumption. To reduce static power consumption, megablock shutdown method considering power line noise is also employed. To evaluate the proposed architecture when applied multimedia SoC, system-level control flow and low-power control algorithm are developed and the power consumption was calculated based on thor From the simulation results, power consumption was reduced to about 60%. Considering the line width reduction and increased leakage current due to heat dissipation in chip core, the proposed architecture shows steady power reduction while it goes worse in conventional architectures.

Magnetic Investigation of the Yangsan Fault (양산 단층에 대한 자력탐사 연구)

  • Kwon, Byung-Doo;Lee, Ki-Won
    • Economic and Environmental Geology
    • /
    • v.24 no.4
    • /
    • pp.421-434
    • /
    • 1991
  • Ground magnetic surveys were conducted at four areas where the Yangsan fault, the most prominent lineament in the Kyeongsang basin, appears to be passed through. For data processing, IGRF correction, upward continuation and reduction-to-the-pole were performed. The automatic inversion by using a matrix computation method, which takes the depth to bottom layer of the horizontal two layer structure as the model parameter, has been attempted to delineate the subsurface structure. Upward continuation of the surface magnetic map to the same level of the aeromagnetic survey (KIER, 1989) resulted in very similiar patterns to those of aeromagnetic data. Subsurface modeling of eight profile data show that the strike and dip of the Yangsan fault in study areas are $N6^{\circ}-15^{\circ}E$, and near vertical to somewhat eastward, repectively, despite of the local lithological contrast of each study area. It seems that the magnetic effect of faulting in the study area 1, which locates in the most northern part of the survey areas, is disturbed by that of igneous intrusion. At study area 2, the possibility of volcanic or igneous intrusion, which is 200-300 meters wide along the fault plane was presented. At study area 3, unlike other study areas, distinct fracture zone of 500-700 meters in width was revealed along the surface fault line. The andesitic rocks of the study area 4 have very high susceptibilities and the fault line on surface of this area was shifted about 500 meter eastward, as compared with the inferred fault line by the previous study.

  • PDF

Current Sensorless Three Phase PWM AC/DC Boost Converter with Unity Power Factor (전류센서리스 단위역률 3상 PWM AC/DC Boost 컨버터)

  • 천창근;김철우
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.17 no.6
    • /
    • pp.105-112
    • /
    • 2003
  • Diode rectifier which can't be controlled output voltage and phase control converter as AC/DC converter have low power factor and harmonics of lower order in the line current. In this paper, three phase PWM(Pulse Width Modulation) AC/DC boost converter is studied to solve these problems. The characteristics of a proposed converter are to control the phase of current without current sensor as a very simple control algorithm using circuit parameters only and to apply sinusoidal PWM method with fixed switching frequency due to a difficult design of input filter and switching device. We simulate for the proposed algorithm that high power factor is achieved and DC link voltage has fast dynamic response without ripple in rectifying and regenerating operation. As a result of experiment with circuit parameter(inductor, capacitor) decided in simulation, the proposed converter had high power factor and reduction of low order harmonics as against diode rectifier.

An influence of operator's posture on the shape of prepared tooth surfaces for fixed partial denture (진료자세가 고정성 국소의치의 지대치 삭제에 미치는 영향)

  • Won, In-Jae;Kwon, Kung-Rock;Pae, Ah-Ran;Choi, Dae-Gyun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.49 no.1
    • /
    • pp.38-48
    • /
    • 2011
  • Purpose: Dentists suffer back, neck and shoulder pain during their careers due to bad operating posture. If dentists have a good operating posture ergonomically, there would be less pain and discomfort in the shoulder and back. Therefore, dentists should learn the Home position which enables dentists to approach a stable posture ergonomically. This study was to compare tooth preparation in the Home position and the Random position, and evaluate the clinical efficacy of the Home position. Materials and methods: Tooth preparation for fixed partial denture was performed on the maxillary left 2nd premolar and maxillary left 2nd molar at the two different operating positions were compared. The amount of occlusal reduction, marginal width, subgingival margin depth, and convergence angle were measured. A T-test was performed separately to compare the results of the Random position and the Home position. Results: 1. The amounts of average thickness of occlusal reduction on fossa were deficient to the ordered ones in the Random position and the Home position (P > .05). 2. The average subgingival margin depth of prepared margin on maxillary left 2nd premolar, maxillary left 2nd molar were excessive in the Random position than in the Home position. On the maxillary left 2nd premolar, there was no statistical difference in the Random position and the Home position except Distal midline, DL line angle, Lingual midline, ML line angle (P< .05). On the maxillary left 2nd molar, there was no statistical difference in the Random position and the Home position (P < .05). 3. Average convergence angle in the Random position and the Home position were excessive compared to the ordered angle. There was no statistical difference in the Random position and the Home position (P > .05). 4. Analysis of pearson correlation : In the Random position, the amounts of average thickness of occlusal reduction, the average subgingival margin depth of prepared margin, convergence angle were significantly associated with each other (P < .05). But in the Home position, they were not significantly associated with each other (P < .05). 5. The time needed for preparation in the Home position was faster or equal than that of the Random position as time went on. Conclusion: In conclusion, there were no significant differences between Home position and Random position in measures of occlusal reduction, marginal width, marginal depth, convergence angle. However, preparation time and incidence of damaging adjacent teeth were less in Home position than in Random position. Therefore, if trained properly, Home position which is more ergonomically stable can be adopted for clinical use.

Effects of Horseshoe Expander (Horseshoe Expander의 확장 효과에 관한 연구)

  • Chung, Kyu-Rhim;Park, Young-Guk;Lee, Young-Jun;Kim, Hong-Suk
    • The korean journal of orthodontics
    • /
    • v.30 no.5 s.82
    • /
    • pp.553-563
    • /
    • 2000
  • Horseshoe Expander is one of Slow Maxillary Expansion(SME) which aims to accommodate the contra- lateral expansion and midpalatal suture expansion or the palate. The appliance consists of skeleton type strew embedded in split Horseshoe appliance. It is the objectives of the presentation to manifest the changes in dental & craniofacial components subsequent to the application of Horseshoe Expander. The subjects for this study consisted of 32 patients (mean age : 12.7). frontal, lateral cephalometric headfilm were taken and study casts were fabricated before and after expansion. 24 items were measured, compared preexpansion with postexpansion. Especially, palatal volume was measured by means of 'Hydro-measurement method'. Tooth axis measurement on the dental casts were made with Universal bevel protractor, and Horseshoe Expander group were compared with RME group. This study of changes to maxillary expansion with Horseshoe Expander revealed the following significant results. 1. Triangular-shaped expansion pattern appeared in frontal cephalometric headfilm. 2. Palatal plane, occlusal plane, mandibular plane and upper incisor to FH increased in lateral cephalometrir headfilm. 3. Palatal volume increased significantly. A slight bite opening, reduction of occlusal contact points showed in dental casts. 4. A 2.2:1 ratio of the amount of intermolar width in maxilla(orthodontic movement) to maxillary width (orthopedic movement) was determined. 5. Horseshoe Expander group has less buccal tipping tendency than RME group, by taking high correlation coefficients in the upper second premolar and first molar. It was suggested that Horseshoe Expander showed less orthodontic changes, less buccal tipping tendency. In addition, it was effective in maxillary expansion.

  • PDF

Effects of the Ge Prearmophization Ion Implantation on Titanium Salicide Junctions (게르마늄 Prearmophization 이온주입을 이용한 티타늄 salicide 접합부 특성 개선)

  • Kim, Sam-Dong;Lee, Seong-Dae;Lee, Jin-Gu;Hwang, In-Seok;Park, Dae-Gyu
    • Korean Journal of Materials Research
    • /
    • v.10 no.12
    • /
    • pp.812-818
    • /
    • 2000
  • We studied the effects of Ge preamorphization (PAM) on 0.25$\mu\textrm{m}$ Ti-salicide junctions using comparative study with As PAM. For each PAM schemes, ion implantations are performed at a dose of 2E14 ion/$\textrm{cm}^2$ and at 20keV energy using $^{75}$ /As+and GeF4 ion sources. Ge PAM showed better sheet resistance and within- wafer uniformity than those of As PAM at 0.257m line width of n +/p-well junctions. This attributes to enhanced C54-silicidation reaction and strong (040) preferred orientation of the C54-silicide due to minimized As presence at n+ junctions. At p+ junctions, comparable performance was obtained in Rs reduction at fine lines from both As and Ge PAM schemes. Junction leakage current (JLC) revels are below ~1E-14 A/$\mu\textrm{m}^{2}$ at area patterns for all process conditions, whereas no degradation in JLC is shown under Ge PAM condition even at edge- intensive patterns. Smooth $TiSi_2$ interface is observed by cross- section TEM (X- TEM), which supports minimized silicide agglomeration due to Ge PAM and low level of JLC. Both junction break- down voltage (JBV) and contact resistances are satisfactory at all process conditions.

  • PDF

Development and utility evaluation of new Multi-Leaf Collimator for Diagnostic X-ray Equipment

  • Ji, Hoon;Han, Su Chul;Baek, Jong Hyeun;Lee, Dong Hoon;Park, Seungwoo
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.2
    • /
    • pp.936-942
    • /
    • 2018
  • The diagnostic multi-leaf collimator preventing unnecessary dose from entering into patients during the diagnostic examination was made in this study. The movement of the entire 50 leaves was embodied with the group of 25 ones thereof configured in a pair facing each other on the left and right of the median line. Dimensions of the length, width, and height of each shielding leaf were $5{\times}0.5{\times}0.5cm^3$ resulting in the maximum boost field of $10{\times}10cm^2$. The material of multi-leaf collimator had the excellence on the machinability with the use of the SKD-11 alloy tool steel having the high wear resistance against frequent movement, and it was devised to control both-side's shielding leaves by moving 2 motors unlike existing remedial multi-leaf collimator that use as many motors as the number of 50 shielding leaves. Thereafter, the transmission dose of leaves, cross-leaf leakage dose, and inter-leaf leakage dose were measured by the developed multi-leaf collimator attached to X-ray equipment. An ionization chamber was used to detect doses there from, and the comparative analysis was carried out by means of the radiographic film that was easy to detect the dose leakage in between each leaf. Results obtained from the test conducted in comparative analysis yielded approximately 98%, 96%, and 94% of shielding efficiency realized at each level of energy of 80kV, 100kV, and 120kV it was confirmed there was no dose leakage resulted from the varied level of irradiation energy. Thus the multi-leaf collimator to be developed based on this study is thought that it could fully reduce the unnecessary dose to patients in the diagnostic test and the shielding efficiency thereof is expected to be increasing if it is made in a miniaturized form with a way of increasing the thickness of each leaf later for an extended application to general diagnostic purposes.

CPW Phase Shifter and Shunt Stub with Air-Bridge Fabricated on Oxidized Porous Silicon(OPS) Substrate (산화된 다공질 실리콘 기판 위에 제작된 에어브리지를 가진 CPW Phase Shifter와 Shunt Stub)

  • Sim, Jun-Hwan;Park, Dong-Kook;Kang, In-Ho;Kwon, Jae-Woo;Park, Jeong-Yong;Lee, Jong-Hyun;Jeon, Joong-Sung;Ye, Byeong-Duck
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.39 no.9
    • /
    • pp.11-18
    • /
    • 2002
  • This paper presents a CPW phase shifter and shunt stub with air-bridge on a 10-${\mu}m$-thick oxidized porous silicon(OPS) substrate using surface micromachining. The line dimensions of the CPW phase shifter was designed with S-W-Sg = 100-30-400 ${\mu}m$. And the width and length of the air-bridge with "ㄷ“ shape were 100 ${\mu}m$ and 400-460-400 ${\mu}m$, respectively. In order to achieve low attenuation, stepped air-bridge CPW phase shift was proposed. The insertion loss of the stepped air-bridge CPW phase shift is more improved than that of no stepped air-bridge CPW phase shift. The measured phase characteristic of the fabricated CPW phase shifter is close to 180$^{\circ}$ over a very broad frequency range of 28 GHz. The measured working frequency of short-end series stub is 28.7 GHz and the return loss is - 20 dB. And the measured working frequency of short-end shunt stub is 28.9 GHz and the return loss is - 23 dB at midband. As a result, the pattering of stub in the center conductor of CPW lines can offer size reduction and lead to high density chip layouts.

A Study on the Women's Bodysuit Sleeve Block Construction Using Stretch fabrics (Stretch 소재를 사용한 여성용 Bodysuit Sleeve 원형 설계에 관한 연구)

  • Park Gin-Ah
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.29 no.12 s.148
    • /
    • pp.1535-1545
    • /
    • 2005
  • The study aimed firstly, to develop the women's bodysuit sleeve block construction method adopting the appropriate pattern reduction rates according to the fabric stretch property. Secondly, the details applied to the bodysuit sleeve block drafting (Dr the educational and industrial usage were proposed. For these, several distinguishing bodysuit sleeve pattern making methods(i.e. Joseph-Armstrong: T1, Shoben & Ward: T2, Esmod: T3 and Mixed Joseph-Armstrong: T4) were analyzed and divided into two categories that adopt 1) the equally (i.e., T1) and 2) the differently(i.e., T2, T3 & T4) distributed front and back armhole length measurements. Women's sleeve samples were made for the research using the same stretch fabric($50\%\;and\; 70\%$ in wale and course each) to the previous research. A group comprising 5 relevant experts evaluated the fit and comfort features of the samples. Experiments analyzed the appearance of sleeve samples focused on total 13 evaluation parts(including the front/side/back fit tolerance, sleeve centre line, sleeve length, appropriateness of the sleeve appearance balanced with the bodysuit and etc.): and performed the comfort test evaluating three kinds(vertical-front/vertical-side/ horizontal) of arm movements. The most appropriate bodysuit sleeve to fulfil the original aims of the study was suggested. The findings and suggestions throughout the study were: 1) the measurements and required reduction rates for the bodysuit sleeve block developed: outer sleeve length (with 1.0 RR), crown height(with 0.7 RR), front and back armhole lengths measured on the bodysuit blocks ($0\%$ ease amount), elbow width(0.9/0.95 RR), wrist girth measurements(from $12\%\;to\;18\%$ tolerances can be given to): and 2) the differently distributed front and back armhole length measurements resulted in the better fit and comfort through the research.