• 제목/요약/키워드: Line laser

검색결과 902건 처리시간 0.029초

Spatial Information Transfer with a Stationary Coupling Wave in Rb Atoms

  • Bae, In-Ho;Moon, Han-Seb
    • Journal of the Optical Society of Korea
    • /
    • 제12권3호
    • /
    • pp.192-195
    • /
    • 2008
  • We report on the spatial information of a coupling laser transfer into a reflected probe laser; the transfer is achieved by means of electromagnetically induced transparency through a common excited state connected with $5S_{1/2}-5P_{1/2}(F=1{\rightarrow}F'=2)$ in the $^{87}Rb\;D_1$ line. When the coupling laser was spatially modulated as a stationary wave, the absorption of the probe laser was enhanced and the reflection of the probe laser was generated. When the coupling laser was spatially modulated by a mask, we observed that the reflection light of the probe laser was modulated as the shape of the mask. The Bragg reflection transferred the spatial information of the coupling laser. The reflection was approximately 7% of the incident power of the probe laser.

Blue Multi-Laser-Diode Annealing(BLDA) Technologies for Poly-Si Films

  • Ogino, Yoshiaki;Iida, Yasuhiro;Sahota, Eiji;Terao, Motoyasu;Chen, Yi;Noguchi, Takashi
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2009년도 9th International Meeting on Information Display
    • /
    • pp.945-947
    • /
    • 2009
  • We developed a new laser irradiation (BLDA: Blue Multi-Laser-Diode Annealing) system. The system forms the uniform line beam, which is constructed by 48 pieces of semiconductor lasers. This new system has achieved high laser output stability and the highly accurate beam shape by adopting a reliable laser control, the auto-focus control in addition to an original laser photosynthesis technology and the beam homogenizing technology. It was confirmed to crystallize the Si films effectively with good quality.

  • PDF

Optimization of Diode-pumped Cesium Vapor Laser Using Frequency Locked Pump Laser

  • Hong, Seongjin;Kong, Byungjoo;Lee, Yong Soo;Oh, Kyunghwan
    • Current Optics and Photonics
    • /
    • 제2권5호
    • /
    • pp.443-447
    • /
    • 2018
  • We propose a diode-pumped cesium laser using frequency locking of a pump laser that can effectively increase the maximum output power of the cesium laser. We simultaneously monitored the absorption spectrum of cesium and the laser output power, and the frequency of pump laser was locked at the center of the $D_2$ absorption line of the cesium atom to obtain an effective gain enhancement. Using this scheme, we have achieved output power increase of ~0.1 W compared to when frequency locking was not applied. Furthermore, by optimizing the temperature of the cesium cell and the reflectivity of the output coupler, we successfully achieved an output power of 1.4 W using the pump power of 2.9 W, providing a slope efficiency of 61.5% and optical-to-optical efficiency of 49%.

LASER-PRODUED PLASMA AS AN X-RAY SOURCE

  • 김효근
    • 한국광학회:학술대회논문집
    • /
    • 한국광학회 1991년도 제6회 파동 및 레이저 학술발표회 Prodeedings of 6th Conference on Waves and Lasers
    • /
    • pp.64-64
    • /
    • 1991
  • The interaction of high-intensity, focused, nanosecond laser light with matter results in the production of high-temperature plasma, which in turn emits an intense pulse of x rays. The x-ray spectrum consists of strong line components of several keV photon energy and broad continuum. Such an x-ray source provides many advantages over conventional ones for many applications. Pulse nature of the x-ray emission is well-suited for studying transient phenomena and for imaging living biological specimen. Recent experiments have also shown that the laser plasma x ray may be used for x ray lithography. These studies and other applications will be discussed in detail.

  • PDF

다중회귀분석을 이용한 $CO_2$레이저 용접 비드 예측 (Estimation of $CO_2$ Laser Weld Bead by Using Multiple Regression)

  • 박현성;이세헌;엄기원
    • Journal of Welding and Joining
    • /
    • 제17권3호
    • /
    • pp.26-35
    • /
    • 1999
  • On the laser weld production line, a slight alteration of the welding condition changes the bead size and the strength of the weldment. The measurement system is produced by using three photo-diodes for detection of the plasma and spatter signal in $CO_2$ laser welding. The relationship between the sensor signals of plasma or spatter and the bead shape, and the mechanism of the plasma and spatter were analyzed for the bead size estimation. The penetration depth and the bead width were estimated using the multiple regression analysis.

  • PDF

레이저 용접 로봇의 경로 생성에 관한 연구 (Study on Path Generation for Laser Welding Robot)

  • 강희신;서정;박경택
    • 한국레이저가공학회지
    • /
    • 제13권4호
    • /
    • pp.14-20
    • /
    • 2010
  • Robot path generation and laser welding technology for manufacturing automotive body are studied. Laser welding and industrial robot systems are used with the robot based laser welding system. The laser system used in this study is 1.6kW Fiber laser, while the robot system is 6 axes Industrial robot (payload: 130kg). The robot based laser welding system is equipped with laser scanner system for remote laser welding. The laser source, robot and laser scanner system are used to increase the processing speed and to improve the process efficiency. The welding joints of steel plate are butt and lapped joints. The quality test of the laser welding are through the observation the shape of bead on plate and cross-section of welding part. The 3 dimensional laser welding for non-linear pipe welding line is performed. This paper introduces the robot based laser welding system to resolve the limited welding speed and accuracy of the conventional spot welding system.

  • PDF

Laser Direct Writing 방법을 이용한 광도파로 제작 (Fabrication of waveguide using UV Ar-ion laser direct writing)

  • 강희신;서정;이제훈;김정오
    • 한국레이저가공학회지
    • /
    • 제8권1호
    • /
    • pp.9-18
    • /
    • 2005
  • The laser direct writing method using a UV Argon-ion laser is studied for fabrication of waveguide. The laser direct writing system is constructed with a vision camera, a xy-stage, a motion controller and the delivery components of a laser beam. The UV Argon-ion laser has wavelength range of $333.6\~363.8$ nm. A photo-active UV curable polymer for a planar light-wave circuit(PLC) of single mode is used. This polymer is irradiated by Argon-ion laser and developed by a solvent after a post-baking. The optimum laser direct writing condition is obtained experimentally by changing various process parameters such as laser power, writing speed and focal length. The propagation and coupling loss of a optical waveguide was measured as 1dB/cm and 0.6dB/cm, respectively. Also, the minimum width of waveguide of $100{\mu}m$(ZPLW-207) is obtained. Finally, the waveguides of line, bend and branch type are successfully fabricated.

  • PDF

펨토초 레이저 펄스를 이용한 환원된 그래핀의 최소 선폭 패턴 구현에 관한 연구 (The study of optimal reduced-graphene oxide line patterning by using femtosecond laser pulse)

  • 정태인;김승철
    • 한국융합학회논문지
    • /
    • 제11권7호
    • /
    • pp.157-162
    • /
    • 2020
  • 최근 레이저를 이용하여 환원된 친환경 그래핀 패턴 기술(Laser Induced Graphene, LIG)은 간단하고 효율적으로 원하는 형태로 다양한 기판 위에 패터닝하는 것이 가능하여 신축 유연 전자 소자, 박막 형태의 에너지 저장 소자 등과 같이 새로운 친환경 전자 소자 제작에 많이 활용되고 있다. 이러한 그래핀 패턴 구조를 이용한 전자 소자의 성능과 효용성을 높이기 위해서는 그래핀 고유의 2차원 특성을 유지하면서 가능한 최소한의 선폭을 구현할 수 있는 최적화된 레이저 패터닝 조건에 대한 연구가 필수적이다. 본 논문에서는 최근 레이저 그래핀 패턴 연구에서 많이 사용되는 Ti:sapphire 펨토초 레이저를 이용해서 그래핀 광-열 산화반응을 분석하여 최적화된 그래핀의 최소선폭을 구현하였다. 레이저 에너지의 확산 효과를 최소화하기 위하여 레이저 광강도와 레이저 스캔 속도를 조절하여 최적의 그래핀 특성을 나타내는 패턴을 연구하였으며 18 ㎛의 집속된 빔을 이용하여 최소 30 ㎛의 이차원 그래핀 선폭을 구현하였다.

인체 편평상피세포암세포주에서 9-Hydroxypheophorbide-$\alpha$와 660nm Diode 레이저를 이용한 광역학치료의 항암효과 (Anticancer Effect of Photodynamic Therapy using 9-Hydroxypheophorbide-$\alpha$ and 660nm Diode Laser on Human Squamous Cell Carcinoma Cell Line)

  • 김한균
    • 대한두경부종양학회지
    • /
    • 제17권1호
    • /
    • pp.3-7
    • /
    • 2001
  • Objectives: New photosensitizer 9-hydroxypheophorbide-$\alpha$(9-HpbD-$\alpha$) was derived from chlorophyll in water with peak absorption at 660nm. 9-HpbD-$\alpha$ was tested with 660 nm diode laser for the anticancer effect of photodynamic therapy. Materials and Methods: Human SNU 1041 cells were seeded into 96 well plate at a density of $$ cells/well for 24 hours. Cells were washed with media containing various concentration of 9-HpbD-$\alpha$ ranging from $0{\mu}g/ml\;to\;3.75{\mu}g/ml$. Then, laser treatment was done with 660nm diode laser ($10mW/cm^2$) at various time setting (0, 30, 60, 90, 120 minutes) and with various time interval (0, 1, 4, 6, 18 hours). The treated cells were incubated 48 hours and MTT assay was done to measure the viability of cells. Results: The viability of cells was more than 90% after laser treatment in control group. The viability of cells was decreased with increasing concentration of 9-HpbD-$\alpha$ and laser treatment time in experimental groups. The viability of cells was decreased significantly as the interval time between addition of 9-HpbD-$\alpha$ and laser irradiation was increased. Conclusion: This study shows the anticancer effect of photodynamic therapy using 9-HpbD-$\alpha$ and 660nm Diode laser on carcinoma cell line. 9-HpbD-$\alpha$ is considerd as one of new photo sensitizers in the field of photodynamic therapy.

  • PDF

High-resolution Spectroscopy of the Nickel-like Molybdenum X-ray Laser Toward the Generation of Circularly Polarized X-ray Laser

  • Hasegawa, Noboru;Sasaki, Akira;Yamatani, Hiroshi;Kishimoto, Maki;Tanaka, Momoko;Ochi, Yoshihiro;Nishikino, Masaharu;Kunieda, Yuichi;Kawachi, Tetsuya;Yoneda, Hitoki;Iwamae, Atsushi
    • Journal of the Optical Society of Korea
    • /
    • 제13권1호
    • /
    • pp.60-64
    • /
    • 2009
  • We attempted the first measurement of the spectral width of the nickel-like molybdenum x-ray laser (${\lambda}\;=\;18.895\;nm$) by use of a high-resolution spectrometer in order to determine the strength of the magnetic field required for the generation of a circularly polarized x-ray laser. The spectral width was measured to be ${\Delta}{\lambda}\;=\;18\;m{\AA}$ under the substantial lasing condition. The magnetic field required for the generation of a circularly polarized x-ray laser was 40 T. The splitting of the x-ray laser line was clearly obtained under 15 T external magnetic field. The strength of the magnetic field estimated from the splitting of the x-ray laser line was large compared with the external magnetic field. It implies that there might be an alternative mechanism for enhancement of the magnetic field in the gain medium plasma.