• Title/Summary/Keyword: Line injection system

Search Result 209, Processing Time 0.021 seconds

Effect of cake resistance by first-aggregation of in-line injection system (인라인 주입방식의 최초응집이 케이크 저항에 미치는 영향)

  • KIM, Taeyoung;PARK, Heekyung
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.22 no.3
    • /
    • pp.281-288
    • /
    • 2008
  • Cake resistance is influenced by floc size deposited on membrane surface. Enlarging floc size can reduce cake resistance. The small particles are enlarged by coagulation and flocculation process in conventional mixing tank at membrane filtration system. Fully-grown flocs for reducing the cake resistance, however, are ruptured while passing through a pump. In light of this fact, this study aims to experimentally look at the reaggregation phenomenon of mixing system. In addition, reaggregation phenomenon of mixing system is compared with first-aggregation of in-line injection system in which coagulant is injected just before a pump. These results suggest that first-aggregation of in-line injection system is better than reaggregation of mixing system for G-value above $3100sec^{-1}$. Since G-value in pipe of actual membrane filtration system are usually larger than $3100sec^{-1}$. The performance of in-line injection system is expected to be better than the conventional mixing tank system.

An Experimental Study of the High-Speed Rotating Fuel Injection System with In-line Injection Orifice (직렬식 분무오리피스를 적용한 회전 연료분사노즐의 분무특성연구)

  • Jang, Seong-Ho;Choi, Seong-Man
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2009.11a
    • /
    • pp.202-206
    • /
    • 2009
  • We studied the spray characteristics of the high-speed rotating fuel injection system. The diameter of in-line injection orifices are varied from 1mm to 5mm and the number of in-line injection orifices are varied from 3 to 12. Droplet size, velocity and spray distribution were measured by the PDPA(Phase Doppler Particle Analyzer) system and spray was visualized. From the test results, the liquid column generated from the injection orifice is mainly controlled by the rotational speeds. Also diameter of injection orifices and number of injection orifices have influence on the diameters of droplet. Consequently, we find out that the basic mechanism of controlling the droplet size is the liquid film thickness in the injection orifice.

  • PDF

Particle Dispersibility Improvement of Polyester Fibers with a New Line Injection

  • Park, Seong-Yoon;Kim, Hak-Yong;Jin, Fan-Long;Park, Soo-Jin
    • Bulletin of the Korean Chemical Society
    • /
    • v.31 no.9
    • /
    • pp.2637-2643
    • /
    • 2010
  • In order to develop a new line injection system for spin draw yarn (FD SDY) fibers, the effect of various parameters in extrusion and melt line conditions on the dispersion and distribution of $TiO_2$ particles within FD PET fibers was investigated. As a result, the dispersibility of $TiO_2$ particles in a PET matrix is found to depend on the particle size and its surface characteristics. Surface modification of $TiO_2$ by dimethyl polysiloxane resulted in the improved dispersibility and affinity of $TiO_2$ particles in the PET matrix. Especially, residence time, mixing temperature, and mixing shear rate in the new line injection system under the SDY spinning process were very important parameters to minimize the agglomeration of $TiO_2$ particles. The FD SDY prepared by the new line injection system was superior to those using the polymerization process and the conventional masterbatch chip dosing process in the color-L and color-b values of the fibers.

Study on Scaling Analysis and Design Methodology of Passive Injection Test Facility (피동 주입 시험 장치의 척도 해석 및 설계 방법론 연구)

  • Bae, Hwang;Lee, Minkyu;Ryu, Sung-Uk;Shin, Soo Jai;Kim, Young-In;Yi, Sung-Jae;Park, Hyun-Sik
    • The KSFM Journal of Fluid Machinery
    • /
    • v.19 no.5
    • /
    • pp.50-60
    • /
    • 2016
  • A design methodology of the modeled test facility to conserve an injection performance of a passive safety injection system is proposed. This safety injection system is composed of a core makeup tank and a safety injection tank. Individual tanks are connected with pressure balance line on the top side and injection line on the bottom side. It is important to conserve the scaled initial injection flow rate and total injection time since this system can be operated by small gravity head without any active pumps. Differential pressure distribution of the injection line induced by the gravity head is determined by the vertical length and elevation of each tank. However, the total injection time is adjustable by the flow resistance coefficient of the injection line. The scaling methodology for the tank and flow resistance coefficient is suggested. A key point of this test facility design is a scaling analysis for the flow resistance coefficient. The scaling analysis proposed on this paper is based on the volume scaling law with the same vertical length to the prototype and can be extended to a model with a reduced vertical length. A set of passive injection test were performed for the tanks with the same volume and the different length. The test results on the initial flow rate and total injection time showed the almost same injection characteristics and they were in good agreement with the design values.

On-line Monitoring of Glucose and Starch by a Flow Injection Analysis Technique (흐름주입분석 기술에 의한 글루코우스와 전분의 온라인 모니터링)

  • 김준홍;박돈희;이종일
    • KSBB Journal
    • /
    • v.16 no.5
    • /
    • pp.459-465
    • /
    • 2001
  • The on-line monitoring technique for the concentrations fo glucose and starch by FIA(Flow Injection Analysis)system was studied. Glucose oxidase(GOD) and amyloglucosidase(AMG) were immboilized on VA-Fpoxy carrier and integrated into the FLA system. The pH, buffer flow rate and temperature were optimized and the effects of salts and metabolites dissolved in the sample on the activity of immobilized enzyme were investigated. GOD-FIA and AMG/GOD-FIA were applied for the on-line monitoring of the glucose and starch in a simulated bioprocess. The on-line measurements of glucose concentrations by GOD-FIA agreed with off-line data well and the AMG/GOD-FIA with single cartidge system took and advantage over the FIA system with two separated cartridges for the on-line monitoring of starch concentrations.

  • PDF

Comparison of three small-break loss-of-coolant accident tests with different break locations using the system-integrated modular advanced reactor-integral test loop facility to estimate the safety of the smart design

  • Bae, Hwang;Kim, Dong Eok;Ryu, Sung-Uk;Yi, Sung-Jae;Park, Hyun-Sik
    • Nuclear Engineering and Technology
    • /
    • v.49 no.5
    • /
    • pp.968-978
    • /
    • 2017
  • Three small-break loss-of-coolant accident (SBLOCA) tests with safety injection pumps were carried out using the integral-effect test loop for SMART (System-integrated Modular Advanced ReacTor), i.e., the SMART-ITL facility. The types of break are a safety injection system line break, shutdown cooling system line break, and pressurizer safety valve line break. The thermal-hydraulic phenomena show a traditional behavior to decrease the temperature and pressure whereas the local phenomena are slightly different during the early stage of the transient after a break simulation. A safety injection using a high-pressure pump effectively cools down and recovers the inventory of a reactor coolant system. The global trends show reproducible results for an SBLOCA scenario with three different break locations. It was confirmed that the safety injection system is robustly safe enough to protect from a core uncovery.

Simulation on the Characteristics of PLN Diesel Injection System by Cam Profile (연료캠 형상에 따른 PLN 디젤 분사계의 분사특성에 관한 시뮬레이션)

  • Lee, J.H.;Wang, W.K.;Ahn, S.K.
    • Journal of Power System Engineering
    • /
    • v.1 no.1
    • /
    • pp.42-51
    • /
    • 1997
  • In this study, in order to investigate the influence of cam profile on the injection rate, the characteristics of injection in PLN (pump - line - nozzle) diesel injection system were simulated. Six types of the profile of fuel cam were used for simulation. The maximum injection pressure and maximum injection rate of initial and end phase were analyzed to demonstrate the characteristics of injection. The mathematical model of the injection system and the computation results were verified by experimental results. Simulation results showed that the maximum injection pressure, maximum injection rate, injection quantity and pressure drop in the end phase were proportional to the velocity of fuel cam during the effective stroke.

  • PDF

Development of a Flow Injection Analysis Technique for On-line Monitoring of Xylitol Concentrations (자일리톨 농도의 온라인 모니터링을 위한 흐름주입분석기술 개발)

  • 이종일
    • KSBB Journal
    • /
    • v.17 no.4
    • /
    • pp.339-344
    • /
    • 2002
  • Flow injection analysis technique for monitoring of xylitol concentrations in biological processes has been developed using xylitol oxidase (XYO) immobilized on VA-Epoxy Biosynth carrier. The immobilized XYO cartridge has been integrated into a FIA system with an oxygen electrode and systematically investigated with regards to the factors which can affect the activity of the immobilized XYO, such as pH, temperature, salt concentration etc. The activity of the immobilized XYO increased with the temperature ($19.0 - 29.0^{circ}C$) and sample injection volume ($75-250\muL$) and molarity of potassium phosphate buffer (0.1-1 M), but it reached the highest value at pH 8.5. The XYO-FIA system has been also applied for on-line monitoring of xylitol concentrations in a reactor and showed good operational stability and agreement with off-line data measured with HPLC.

Simulation of injection-compression molding for thin and large battery housing

  • Kwon, Young Il;Lim, Eunju;Song, Young Seok
    • Current Applied Physics
    • /
    • v.18 no.11
    • /
    • pp.1451-1457
    • /
    • 2018
  • Injection compression molding (ICM) is an advantageous processing method for producing thin and large polymeric parts in a robust manner. In the current study, we employed the ICM process for an energy-related application, i.e., thin and large polymeric battery case. A mold for manufacturing the battery case was fabricated using injection molding. The filling behavior of molten polymer in the mold cavity was investigated experimentally. To provide an in-depth understanding of the ICM process, ICM and normal injection molding processes were compared numerically. It was found that the ICM had a relatively low filling pressure, which resulted in reduced shrinkage and warpage of the final products. Effect of the parting line gap on the ICM characteristics, such as filling pressure, clamping force, filling time, volumetric shrinkage, and warpage, was analyzed via numerical simulation. The smaller gap in the ICM parting line led to the better dimensional stability in the finished product. The ICM sample using a 0.1 mm gap showed a 76% reduction in the dimensional deflection compared with the normal injection molded part.

On-line Monitoring of Glucose and Acetate by Flow-Injection Analysis in Escherichia coli Fermentation Process (대장균 발효공정에서 흐름주입분석을 이용한 글루코스와 초산의 온라인 모니터링)

  • 이종일
    • KSBB Journal
    • /
    • v.13 no.3
    • /
    • pp.244-250
    • /
    • 1998
  • Flow-injection analysis (FIA) for on-line monitoring of glucose and acetate are described and employed in E.coli fermentation process. Glucose oxidase (GOD) for the detection of glucose is immobilized on epoxy polymer support, which is packed in a small cartirdge, and applied to a GOD-FIA system. The detection of acetate is based on the inhibition of acetate to the oxidation of sarcosine by sarcosine oxidase (SOD). SOD is also immobilized on epoxy polymer support and used for a SOD-FIA system. GOD-FIA system is characterized as well as SOD-FIA system by the investigation of the effects of pH, temperature and metabolites in samples on the peak height. GOD-FIA and SOD-FIA systems were also applied for on-line On-line measurements buy FIA measurements by FIA were in god agreement with off-line measurements.

  • PDF