• Title/Summary/Keyword: Line discharge

검색결과 529건 처리시간 0.026초

6.6 kV 전동기 고정자 권선의 절연진단과 절연파괴 특성 (Characteristics of Insulation Diagnosis and Failure in 6.6 kV Motor Stator Windings)

  • 김희동;공태식
    • 한국전기전자재료학회논문지
    • /
    • 제25권4호
    • /
    • pp.309-314
    • /
    • 2012
  • To assess the condition of stator insulation, nondestructive and overpotential tests were performed on four high voltage motors. The stator windings under these tests have nominal ratings of 6.6 kV. After completing nondestructive tests, the AC overvoltage applied to the stator windings was gradually increasing until insulation failure in order to obtain the breakdown voltage. No. 1, No. 2, No. 3 and No. 4 of 6.6 kV motors failed near rated voltage of 18.4 kV, 19.8 kV, 19.7 kV and 21.7 kV, respectively. The breakdown voltage of four motors was higher that expected for good quality coils(14.2 kV) in 6.6 kV motors. Almost all of failures were located in a line-end coil at the exit from the core slot. The breakdown voltages and the types of defects showed strong relation to the stator insulation tests such as in the case of AC current, dissipation factor($tan{\delta}$) and partial discharge magnitude.

강변저류지 홍수조절효과 분석을 위한 유량조절장치 개발 (The Development of Discharge Control Apparatus in Unsteady Flow for Analysis of Flood Control Effects in Detention Basin with Side Weir)

  • 홍상진;김서준;윤병만
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2011년도 학술발표회
    • /
    • pp.314-314
    • /
    • 2011
  • 강변저류지는 하천변에 위치한, off-line 형 치수구조물로 하천의 수위 변화에 따라 저류량이 변한다. 그러므로 강변저류지의 홍수조절효과는 부정류 흐름 상태를 재현하여 모의해야 한다. 현재 국내에는 강변저류지 홍수조절효과 분석을 위해 주로 1차원 부정류 수치모형인 HEC-RAS를 사용하고 있다. 하지만 1차원 부정류 계산 결과에 대한 정확도 검증 없이 사용되고 있다. 따라서 이를 검증하고 보완할 수 있는 부정류 수리실험이 필요하다. 이에 본 연구에서는 상류 유입수문곡선을 재현할 수 있는 부정류 유량조절장치를 개발하였으며, 개발된 유량조절장치의 재현 능력을 검증하고 강변저류지 홍수조절효과 분석에 대한 적용 가능성을 확인하였다. 부정류 수리실험은 정규분포형 수문곡선과 이중 첨두를 가지는 수문곡선 및 다양한 첨두 지속시간을 갖는 수문곡선 형태에 대해 유량조절장치의 재현 능력을 검토하였다. 검토 결과 개발된 유량조절장치의 재현 수문곡선은 첨두 홍수량을 기준으로 약 1 % 이내의 오차를 보여 매우 만족스러운 결과를 얻었다. 향후 강변저류지의 홍수 조절효과 분석에 사용한다면 좀 더 현실적이고 정량적인 치수능력 평가가 될 수 있을 것이라 판단된다.

  • PDF

Effect of Metallic Particles on E-field Enhancement in Extra High Voltage Gas-insulated Transmission Lines

  • Rao, M. Mohana;Satyanarayana, S.;Kumar, S. Vinay;Jain, H.S.
    • Journal of Electrical Engineering and Technology
    • /
    • 제5권4호
    • /
    • pp.631-636
    • /
    • 2010
  • Gas-insulated transmission lines (GITL) are valued as technological solutions in hydro-power stations due to their enormous power handling capabilities. The performance of GITL is a function of the size of metallic particles inside the gas-insulated chamber. Electrostatic field (E-field) enhancement is a common phenomenon in gas-insulated lines due to these metallic particles. In this study, the E-field enhancement factor is calculated by considering metallic particles at various locations in the gas-insulated line/bus section, such as high-tension (HT) conductor, high-voltage shields, support insulator, and inner surface of grounded enclosure. For this purpose, a two-dimensional model based on finite element (FE) method is developed. The length of the metallic particle is in the range of 1 to 10 mm while the diameter is between 1 to 3 mm. E-field enhancement is also computed for various particle configurations of the gas-insulated system, with focus on dielectric coating made of epoxy on HT conductor and inner surface of grounded enclosure.

우리나라 하수처리장 방류수 수질현황 및 특성 (Survey of the Secondary Effluents from Municipal Wastewater Treatment Plants in Korea)

  • 김영철;안익성;강민기
    • 한국물환경학회지
    • /
    • 제21권2호
    • /
    • pp.158-168
    • /
    • 2005
  • In this study, the discharging effluents from have been 9 municipal wastewater treatment plants surveyed for 1 year-period. Statistics including probability distribution, cumulative occurrence concentration and other statistical parameters were presented. In addition, treatment performance and its stability were also discussed. Most of the plants, have an operational problem of high soluble organic content in the secondary effluent which may be associated with the integrated treatment of human and livestock manures. Nitrogen concentration in the effluents were usually higher during the period of summer and winter. It was found that this is mainly due to lack of the proper C/N ratio during the summer, or/and the effects of low temperature and less dilution by dry weather during the winter. Phosphorus concentration is sharply increased in June. Discussion with plant operators told that it is due to the dissolution of phosphate from the sludge accumulated in the primary settling tanks from the early spring to june. During this period, usually, sludge treatment line is highly overloaded with flush-outs of the sediments also stored in the bottom of combined sewer due to the low flow during winter season. Most of the plants can meet new effluent discharge limits of the nitrogen and phosphorus, and total coliform without further treatment.

횡월류 위어의 유량계수에 관한 실험적 연구 (An Experimental Study on Discharge Coefficient of Sideweir)

  • 여창건;김지호;이호열;송재우
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2004년도 학술발표회
    • /
    • pp.512-515
    • /
    • 2004
  • 횡월류 위어는 수로에서 일정한 월류량을 얻기 위해서 또는 홍수시 하천에서 하류의 유량을 감소시킬 목적으로 설치되는 off-line 저류지에서의 구조물이다. 이러한 횡월류 위어의 단면 설계 시 계획 월류량 산정을 위하여 일반적으로 De marchi공식이 사용되며 De marchi공식은 유량계수($C_M$)와 월류수심의 함수이며, 유량 계수는 여러 연구자들이 실험을 통하여 여러 가지 유량계수 공식으로 제시되었다. 하지만 기존의 제시된 유량계수식($C_M$)들은 동일한 Froude수에 대한 유량계수($C_M$)값이 큰 편차를 보인다. 이는 개개의 유량계수식들이 서로 다른 실험조건에 의한 자료들의 회귀분석으로 산정된 식들이기 때문이다. 본 인구에서는 수리모형실험을 통하여 횡월류 위어의 월류량에 영향을 미치는 유량계수를 산정하고, 기존의 유량계수 공식들과 비교 분석하여 적합한 유량계수식을 제안하였다. 실험은 폭 0.3m의 직선개수로에서 위어의 폭과 유량을 변화시키며 실험을 반복 수행하였으며, 실험결과 유량계수는 Froude수에 반비례하는 경향을 나타냈다. 산정된 유량계수를 Borghei, Subramanya, Hager, Ranga Raju 공식들과 비교한 결과 Borghei 공식에 의한 계산치와 실험치가 $7.5\%$의 오차를 보이던 가장 근사한 값을 보였다.

  • PDF

노후 차량의 배기가스 측정을 이용한 산소센서, 인젝터, 점화2차파형의 파형분석 연구 (A Study on Waveform Analysis of Oxygen Sensor, Injector and Secondary Waveform through Emission Characteristics by a Decrepit Vehicle)

  • 유종식;김철수
    • 한국자동차공학회논문집
    • /
    • 제21권5호
    • /
    • pp.151-156
    • /
    • 2013
  • The experiment was done on cars travelling at the speeds of 20km/h, 60km/h and 100km/h using the performance testing mode for chassis dynamometer. In this experiment, the relativity between the secondary waveform coming from ignition coil and exhaust emissions were measured in case of cars with failures, in oxygen sensor, spark plugs. The following results obtained by analysis of the relativity between the secondary waveform and exhaust emissions. 1) When the oxygen sensor is failure, the average value of CO emission measured was 6.8 times higher than the standard CO emission value and the average value of HC emission measured was 2.3 times higher than the standard emission level. 2) When engine parts are in failure, more fuel enters the cylinder due to longer opening duration of injector, and it tended to make CO and HC emission values increase. 3) Combustion duration, the shape of flame propagation during spark line, and the size of the discharge-induced energy were the three main elements that directly cause variations in CO and HC emission values.

6.6 kV급 고압전동기 고정자 권선의 절연열화 평가 (Assessment of Insulation Aging in 6.6 kV Class High Voltage Motor Stator Windings)

  • 김희동;김병한
    • 한국전기전자재료학회논문지
    • /
    • 제19권11호
    • /
    • pp.1067-1071
    • /
    • 2006
  • Prior to destructive testing, diagnostic tests were performed in ten high voltage motors. Diagnostic tests included polarization infer, ac current, dissipation factor$(tan{\delta})$ and partial discharge magnitude. The rewind of motet slater insulation at rated voltage is assessed by the results of these tests. After completing the diagnostic tests, the stator windings of motors were subjected to gradually increasing ac voltage, until the insulation punctured. No. 8 motor failed near rated voltage of 19.0 kV. The breakdown voltage of No. 4 motet was 7.0 kV which is lower that expected for good quality coils in 6.6 kV class motors. The failure was located in a line-end coil at the exit from the core slot. These two motors began operation in 1994. While testing No. 7 motor, flashover occurred between the stator winding and the stator frame at 15 kV. The relationship between the diagnostic test and the drop in insulation breakdown voltage was analyzed.

MPA 유량계 압력감지공의 위치와 유출계수 (Location of pressure sensing holes in MPA flowmeter and discharge coefficients)

  • 김기현;최성길
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2004년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.160-165
    • /
    • 2004
  • MPA (Multi-Point Averaging) flow element is a new type of differential pressure (DP) flow-sensing device that was developed by Seojin Instech to improve the operating characteristics of the conventional Averaging Pilot Tube (APT) flow elements. Operating characteristics of a flowmeter in general can be defined in terms of measurement accuracy and range. Improvement of accuracy and expanding the range of flow measurement were the two main objectives of the development. To achieve these dual objectives several upstream and downstream pressure-sensing holes were placed in MPA flow element. During the course of the development it was found that certain arrangements of the pressure-sensing holes improved measurement accuracy but did not expand operating flow range of Averaging Pilot Tubes. Development tests were performed with water between Reynolds number of 50,000 and 1,000,000 in the four-inch test line at the Alden Research Laboratory, U.S.A. Purpose of this paper is to present the relationship between the various locations of the pressure-sensing holes and the performance characteristics of MPA flow element. Furthermore, the operating characteristics of the best performing MPA are compared with those of typical orifice and APT.

  • PDF

대기압 플라즈마를 이용한 a-Si 식각 기술

  • 노태협;석동찬;유승열
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2013년도 제44회 동계 정기학술대회 초록집
    • /
    • pp.142-142
    • /
    • 2013
  • DBD (Dielectric Barrier Discharge) 대기압 플라즈마를 이용한 a-Si 식각기술에 대한 연구결과를 논하고자 한다. 기술개발의 목적은 대면적 TFT-LCD 혹은 Flexible Display 공정에 적용가능한 대기압 플라즈마 식각장치의 개발 및 검증이다. 실험에서 식각 가스로는 SF6, NF3 등을 사용하였으며, 질소를 기본 가스로 사용하였다. 검증용으로 개발된 대기압 플라즈마 식각 장치는 대기압 플라즈마 장치를 연속적으로 통과하는 in-line system 형식으로 개발되었다. 검증에 사용된 대기압 플라즈마 장치는 300 mm의 방전 폭으로 1세대 LCD기판의 처리가 가능하다. 대기압 플라즈마 식각 기술 개발에서 식각율에 영향을 미치는 변수들은 기판의 온도, 식각가스의 농도, 기판의 이송속도, 기판과 플라즈마 발생장치 사이의 간격 그리고 플라즈마의 인가 전력 등으로 크게 구분지어 생각할 수 있다. 개발된 식각 장치는 SF6를 사용하는 경우 최대 환산 식각율은 500 nm/min 정도이다. 식각 기술에서 중요한 식각 Uniformity와 그와 연관된 a-Si/SiNx 식각 선택비는 사용하는 가스의 Recipe 개발에 중점을 두고 연구를 진행하였다. 식각 Uniformity는 약 7% 이내의 균일도를 갖고 a-Si/ SiNx의 선택비는 10이상의 결과를 얻었다. 또한 식각 가스는 식각 profile에 영향을 줄 수 있는데 대기압 환경에서 형성되는 collisional sheath에도 불구하고 비 등방성 식각이 가능하였다.

  • PDF

표면영상유속계(SIV)를 활용한 홍수유출량 산정 시 주·야간영상의 정확도 비교분석 (Comparative Analysis of Day and Night Time Video Accuracy to Calculate the Flood Runoff Using Surface Image Velocimeter (SIV))

  • 김용석;양성기;류권규;김동수
    • 한국환경과학회지
    • /
    • 제24권4호
    • /
    • pp.359-369
    • /
    • 2015
  • This study analyzed the velocimetry of runoff and measured the flood discharge by applying the SIV (Surface Image Velocimetrer) to the daytime and nighttime flow image data with special reference to Seong-eup Bridge at Cheonmi stream of Jeju during the flow by the severe rainstorm on May 27, 2013. A 1000W lighting apparatus with more than 150 lux was installed in order to collect proper nighttime flow image applied to the SIV. Its value was compared and analyzed with the velocity value of the fixed electromagnetic wave surface velocimetry (Kalesto) at the same point to check the accuracy and applicability of the measured velocity of flow. As a result, determination coefficient $R^2$ values were 0.891 and 0.848 respectively in line with the velocity distribution of the daytime and nighttime image and the flow volume measured with Kalesto was approximately 18.2% larger than the value measured with the SIV.