• Title/Summary/Keyword: Line Voltage Tracking

Search Result 50, Processing Time 0.06 seconds

Tracking Performance Test of Polymer Insulator with Salt Solution which is added Surface Active Agent (계면활성제가 첨가된 염수용액에 따른 폴리머 애자의 트래킹 성능 평가)

  • Cho, Han-Goo;Han, Dong-Hee;Lee, Un-Yong;Lim, Kee-Joe;Choi, In-Hyuk
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.07b
    • /
    • pp.1121-1124
    • /
    • 2004
  • Aging test to estimate life property of polymer insulator is executed through several international standard such as IEC 61109 and CEA tracking wheel test, but is not getting clear conclusion yet. There are two methods in the diagnosis method of polymer insulator such as off-line and on-line. The diagnosis methods in off-line are external condition analysis by the eye, contaminant analysis on surface, surface analysis, pollution withstand voltage test, power frequency flashover voltage test, lightning impulse flashover test, tensile fracture load test and flexural load test. The diagnosis methods in off-line most are the method for virgin and last aged sample. However, the diagnosis method in on-line is method that can be evaluate sample state as progressing continuously aging test in beginning, The diagnosis method in on-line is arranged as following: leakage current measurement, electric field, surface state investigation, thermal image, emitting light measurement and then so. In this paper, the tracking performance of polymer insulator with salt solution which is added surface active agent. The diagnosis of insulator sample has been analyzed by leakage current and visual examination.

  • PDF

Tracking Performance Test of Polymer Insulator with Salt Solution which is added Surface Active Agent (계면활성제가 첨가된 염수용액에 따른 폴리머 애자의 트래킹 성능 평가)

  • Cho, Han-Goo;Lee, Un-Yong;Han, Dong-Hee;Kang, Sung-Hwa;Choi, In-Hyuk;Lim, Kee-Joe
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.18 no.1
    • /
    • pp.62-67
    • /
    • 2005
  • Recently, polymer insulators that are used for high voltage applications have some advantages such as light weight, small size, vandalism resistance, hydrophobicity and easy making process. During outdoor service of polymer insulators, the surface of the insulating material is frequently subjected to moisture and contamination that lead to dry band arcing. Their tracking resistance, erosion resistance, end sealing and shed design are very important because dry band arcing causes degradation of polymer surface. Aging test to estimate life property of polymer insulator is executed through several international standard such as IEC 61109 and CEA tracking wheel test, but is not getting clear conclusion yet. There are two methods in the diagnosis method of polymer insulator such as off-line and on-line. The diagnosis methods in off-line are external condition analysis by the eye, contaminant analysis on surface, surface analysis, pollution withstand voltage test, power frequency flashover voltage test, lightning impulse flashover test, tensile fracture load test and flexural load test. Polymer material is also investigated it's tracking resistance by adding surface active agent in IEC 587. In this paper, the tracking performance of polymer insulator with salt solution which is added surface active agent. The diagnosis of insulator sample has been analyzed by leakage current and visual examination, STRI guide and thermal image camera.

Transformerless Three-Phase Line-connected Photovoltaic PCS (무변압기형 3상 계통연계 PV PCS)

  • Seo, Hyun-Woo;Kwon, Jung-Min;Kwon, Bong-Hwan
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.12 no.5
    • /
    • pp.355-363
    • /
    • 2007
  • In this paper, the transformerless three-phase line-connected PV PCS (photovoltaic power conditioning system) is proposed. An improved P&O (perturb and observe) MPPT (maximum power point tracking) algorithm that prevents local maximum power point tracking is proposed. By controlling the three-phase line-connected voltage source inverter using outer DC-link voltage controller, inner current controller and microcontroller friendly simplified space vector modulation (SVM) method, a unity power factor is achieved. An algorithm is suggested to control the DC-link voltage faster and more correctly for the increase system stability and power factor. All algorithms and controllers are implemented on a single-chip microcontroller and the superiority of the proposed algorithms and controllers is proved by experiments.

The investigation of tracking resistant sheath material for ADSS Optic cable (ADSS 광 케이블 시스용 내 트래킹 재료의 특성에 관한 연구)

  • Lee, Jung-Hee;Seo, Il-Gun;Whang, Sun-Ho;Lee, Gun-Joo;Bak, Seung-Yup;Kim, Kyeung-Min;Lee, Seung-Chan
    • Proceedings of the KIEE Conference
    • /
    • 2002.11a
    • /
    • pp.102-105
    • /
    • 2002
  • ADSS(All Dielectirc Self-Supporting) cable installed under high voltage power cable line suffers a variety of environmental influence, rain, wind, snow fall, chemical pollution, salt fog and electrical stress. Its lifetime is required to be at least 20 years with this harsh weathering condition. The electrical stress under high voltage power line gives rise to dry band arcing and tracking, the severest damage, on the outer sheath of cable. Finally tracking might penetrate sheath and cause the break-down of ADSS cable. Tracking resistant sheath material, therefore, should be used to protect the core of ADSS from dry band arcing and to be sure long lifetime. In this work, we discuss various commercial tracking resistant material to investigate the way of track resistance and compare their mechanical, electrical, weathering and tracking properties through serial experiments. We found track resistant material is categorized into two main type : polyethylene with metal hydroxide and polyethylene with reduced carbon black. The Liquid contaminant, Inclined plane Tracking and Erosion test says the time to track of tracking resistant material with metal hydroxide has a little longer time to track in the high applied voltage than that with carbon black, but mechanical and weathering properties were inferior to.

  • PDF

Tracking Property of Polymer Suspension Insulator for Transmission line with secular variation (경년변화에 따른 송전용 폴리머 현수애자의 트래킹 성능평가)

  • Cho, Han-Goo;Lee, Un-Yong;Lee, You-Jung;Lim, Kee-Joe;Choi, In-Hyuk
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.07a
    • /
    • pp.558-559
    • /
    • 2005
  • Recently, polymer insulators that are used for high voltage applications have some advantages such as light weight, small size, vandalism resistance, hydrophobicity and easy making process. During outdoor service of polymer insulators, the surface of the insulating material is frequently subjected to moisture and contamination that lead to dry band arcing. Their tracking resistance, erosion resistance, end sealing and shed design are very important because dry band arcing causes degradation of polymer surface. In this paper, the tracking property of polymer suspension insulator for power transmission is investigated with CEA tracking wheel test. The diagnosis of insulator sample in tracking test has been analyzed by leakage current, STRI Guide, SEM, FTIR and thermal image.

  • PDF

Maximum power tracking Strategy of a Solar Cell using ZVCS converter (ZVCS 컨버터를 이용한 태양전지 최대전력 검출법)

  • Kwak, Dong-Kurl;Jun, Hyun-Kyu;Kim, Jong-Min;Lee, Hyun-Woo
    • Proceedings of the KIEE Conference
    • /
    • 2001.07b
    • /
    • pp.1032-1034
    • /
    • 2001
  • As well known, a solar cell has an optimal operating point to be able to get the maximum power $P_{max}$. So, many $P_{max}$ tracking controllers using the line voltage of a solar cell have been popularly used. But it may vary depending on the miss match between the solar cell output and the load. In this paper, we investigate the possibilities of $P_{max}$ control using the current tracking controller and the output voltage and the output current instead of the solar cell output power. And we also examine about the optimal power converter using ZVCS step up and down chopper circuit to operate the solar cell at an optimal voltage using these variables. And then, we show some experimental results to confirm the successful operation.

  • PDF

A Study of Seam Tracking by Arc Sensor Using Current Area Difference Method (전류 면적차를 이용한 아크 센서의 용접선 추적에 관한 연구)

  • 김용재;이세헌;엄기원
    • Journal of Welding and Joining
    • /
    • v.14 no.6
    • /
    • pp.131-139
    • /
    • 1996
  • The response of the arc sensor using the welding current and/or welding voltage as its outputs has been obtained by the analysis and/or experiments of the static characteristics of arc sensor. But in order to improve the reliability of arc sensor, it is necessary to know its dynamic characteristics. So in this paper, it is presented the dynamic model of arc sensor including the power source, arc voltage, electrode burnoff rate, and wire feed rate. A numerical simulation of the dynamic model of arc sensor was implemented, computing the welding current with input of CTWD. The results of computer simulations and experiments of $CO_2$arc welding showed that a linear relationship between weaving center - weld line distance and current area difference was established. Additionally, a real-time weld seam tracking system interfaced with industrial welding robot was constructed, the result of the weld seam tracking experiment for weld line with an initial offset error of 5$^{\circ}$was good.

  • PDF

Performance Evaluation of Polymer Insulator using Tracking Wheel and Multi-Aging Test (트래킹 휠과 복합열화시험에 의한 폴리머 애자의 성능 평가)

  • 조한구;안명상;한세원;허종철;이운용
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.07a
    • /
    • pp.119-122
    • /
    • 2000
  • Recently polymer insulators are being used for outdoor high voltage applications. Polymer insulators for transmission line have significant advantages over porcelain and glass insulators, especially for ultra-high voltage transmission lines. Their advantages are light weight, vandalism resistance and hydrophobicity. Polymer insulators are a relatively new technology, but their expected life is still unknown. Therefore these estimating technique are very important. Their life time is related to weathering and operating condition. Multi-aging test is requested because aging factor is occurred by multi-aging than unique aging. The aging test about polymer insulators have mainly carried out by IEC 61109. This paper presents multi-stress chamber experiments and tracking wheel test to examine the tracking and erosion performance of polymer insulator for transmission. Multi-stress testing is able to demonstrate deficiencies of polymer insulator materials and designs, including the nature of interfaces in insulation design. We have investigated IEC 61109 Annex C (5000h aging test) and CEA tracking wheel test as test methods of artificial accelerated aging. The aging degree of polymer insulator is estimated by leakage current, measurement of hydrophobicity degree, damage conditions of insulator surface, withstand voltage test etc.

  • PDF

Initial Firing Angle Control of Parallel Multi-Pulse Thyristor Dual Converter for Urban Railway Power Substations

  • Kim, Sung-An;Han, Sung-Wo;Cho, Yun-Hyun
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.2
    • /
    • pp.674-682
    • /
    • 2017
  • This paper presents an optimal initial firing angle control based on the energy consumption and regenerative energy of a parallel multi-pulse thyristor dual converter for urban railway power substations. To prevent short circuiting the thyristor dual converter, a hysteresis band for maintaining a zero-current discontinuous section (ZCDS) is essential during mode changes. During conversion from the ZCDS to forward or reverse mode, the DC trolley voltage can be stabilized by selecting the optimal initial firing angle without an overshoot and slow response. However, the optimal initial firing angle is different depending on the line impedance of each converter. Therefore, the control algorithm for tracking the optimal initial firing angle is proposed to eliminate the overshoot and slow response of DC trolley voltage. Simulations and experiments show that the proposed algorithm yields the fastest DC voltage control performance in the transient state by tracking the optimal firing angle.

Tracking Resistance and UV Degradation Property of Polymeric Insulating Materials by Cross-Link Time (가교시간에 따른 고분자 재료의 트래킹성과 자외선 열화특성)

  • 천종욱;이운용;조한구
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.07a
    • /
    • pp.447-450
    • /
    • 2002
  • Recently polymeric insulators and arresters are being used for outdoor high voltage applications. Polymeric insulators for transmission line have significant advantages over porcelain and glass insulators, especially for ultra-high voltage(UHV) transmission lines. Their advantages are light weight, vandalism resistance and hydrophobicity. Polymeric insulator kind are a relatively new technology, but their expected life is still unknown. In this paper, the material property for polymeric insulating material such as silicone rubber and EPBM is investigated by cross-link time and the relation between tracking resistance and W resistance is analyzed by IEC 60587 and W aging experiment.

  • PDF