• 제목/요약/키워드: Line Tracer

검색결과 66건 처리시간 0.022초

공초점 레이저 주사 현미경을 이용한 혈구 유동가시화 및 세포공핍층 측정에 관한 연구 (Flow Visualization of Blood Cell and Detection of Cell Depleted Layer Using a Confocal Laser Scanning Microscope)

  • 임수희;김위한;이호;이춘영;박철우
    • 한국가시화정보학회지
    • /
    • 제8권1호
    • /
    • pp.46-52
    • /
    • 2010
  • In the present study, we employed the confocal laser scanning microscopy (CLSM) system to visualize the blood flow field with $1{\times}1{\mu}m^2$ spatial resolution. Based on the confocal microscopic image of red blood cells (RBCs), we performed the velocity vector field measurement and evaluated characteristics of cell migration from the cell depleted layer thickness calculation. The rat and mouse's blood were supplied into a micro glass tubes in vitro. The line scanning rate of confocal microscopy was 15 kHz for a $500{\times}500$ pixels image. As a result, the red blood cell itself can be used as a tracer directly without any kind of invasive tracer particle to get the velocity vector field of blood flow by performing particle image velocimetry (PIV) technique.

Determination of Li by Isotope Dilution Inductively Coupled Plasma Mass Spectrometry

  • Park, Chang J.;Chung, Bag S.
    • 분석과학
    • /
    • 제8권4호
    • /
    • pp.427-434
    • /
    • 1995
  • Inductively coupled plasma mass spectrometry combined with the isotope dilution method is used for the determination of lithium. The isotope dilution method is based on the addition of a known amount of enriched isotope (spike) to a sample. The analyte concentration is obtained by measuring the altered isotope ratio. The spike solution is calibrated through so called reverse isotope dilution with a primary standard. The spike calibration is an important step to minimize error in the determined concentration. It has been found essential to add spike to a sample and the primary standard so that the two isotope ratios should be as dose as possible. Since lithium is neither corrosive nor toxic, lithium is used as a chemical tracer in the nuclear power plants to measure feedwater flow rate. 99.9% $^7Li$ was injected into a feedwater line of an experimental system and sample were taken downstream to be spiked with 95% $^6Li$ for the isotope dilution measurements. Effects of uncertainties in the spike enrichment and isotope ratio measurement error at various spike-to-sample ratios are presented together with the flow rate measurement results in comparison with a vortex flow meter.

  • PDF

A SEARCH FOR MOLECULAR CLOUDS AT HIGH GALACTIC LATITUDE

  • Chi Seung-Youp;Park Yong-Sun
    • 천문학회지
    • /
    • 제39권1호
    • /
    • pp.19-24
    • /
    • 2006
  • We carried out CO survey toward IR-excess clouds using SRAO 6-m telescope in search of molecular $H_2$. These clouds, which show far-infrared excess over what is expected from HI column density, are considered to be candidates of molecular clouds. In order to find new high Galactic latitude clouds, we made mapping observations for 14 IR-excess clouds selected from Reach et al.(1998) in $^{12}CO$ J = 1 - 0 line, supplementing the similar survey in southern hemisphere (Onishi et al. 2001). $^{12}CO$ emission is detected from three IR-excess clouds among 14 objects. Three newly detected clouds exhibit somewhat clumpy morphology and column densities amount to ${\sim}10^{21}\;cm^{-2}$. One of three clouds, DIR120-28, show discrepancy between IR-excess center and CO emission center. It seems that IR-excess may not be an effective tracer of molecular gas. Instead, optical depth$(\tau)$ excess, i.e., IR-excess corrected for temperature dependence, may be more effective tracer of molecular clouds, since, by combining statistics from both hemispheres, we found that the detection rate is higher for IR-excess clouds with lower dust temperature.

QUANTIFYING DARK GAS

  • LI, DI;XU, DUO;HEILES, CARL;PAN, ZHICHEN;TANG, NINGYU
    • 천문학논총
    • /
    • 제30권2호
    • /
    • pp.75-78
    • /
    • 2015
  • A growing body of evidence has been supporting the existence of so-called "dark molecular gas" (DMG), which is invisible in the most common tracer of molecular gas, i.e., CO rotational emission. DMG is believed to be the main gas component of the intermediate extinction region from Av~0.05-2, roughly corresponding to the self-shielding threshold of $H_2$ and $^{13}CO$. To quantify DMG relative to $H{\small{I}}$ and CO, we are pursuing three observational techniques; $H{\small{I}}$ self-absorption, OH absorption, and THz $C^+$ emission. In this paper, we focus on preliminary results from a CO and OH absorption survey of DMG candidates. Our analysis shows that the OH excitation temperature is close to that of the Galactic continuum background and that OH is a good DMG tracer co-existing with molecular hydrogen in regions without CO. Through systematic "absorption mapping" by the Square Kilometer Array (SKA) and ALMA, we will have unprecedented, comprehensive knowledge of the ISM components including DMG in terms of their temperature and density, which will impact our understanding of galaxy evolution and star formation profoundly.

자동 레벨 컨트롤 적재물 운반 시스템의 구현 (Implementation of Automatic Height Adjustment System)

  • 임성재;이태근;장진녕;고예은;이승대
    • 한국전자통신학회논문지
    • /
    • 제17권1호
    • /
    • pp.133-138
    • /
    • 2022
  • 본 논문에서는 물류센터 종사자들의 업무 부담을 덜어주고 사고를 방지하기 위한 시스템을 설계 및 제작하였다. 주 제어장치 아두이노를 기반으로 로드셀 센서를 이용해 무게를 측정하도록 하였다. 작동 시 적재물을 올려 놓는 적재판을 최상단에 위치시켜 허리를 숙이지 않게 하여 편의성을 개선하였고, 적재물이 설정된 값을 초과하면 적재판이 내려가도록 설계하여 안전성도 도모하였다. 라인트레이서를 적용해 지정 루트에서만 작동하게 하여 적재물 이동 시 편리성 증대를 목적으로 제작하였다.

고해상도 3차원 상호상관 PIV 알고리듬 개발 (Development of High-resolution 3-D PIV Algorithm by Cross-correlation)

  • 김미영;최장운;이현;이영호
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 추계학술대회논문집B
    • /
    • pp.410-416
    • /
    • 2001
  • An algorithm of 3-D particle image velocimetry(3D-PIV) was developed for the measurement of 3-D velocity field of complex flows. The measurement system consists of two or three CCD camera and one RGB image grabber. In this study, stereo photogrammetty was applied for the 3-D matching of tracer particles. Epipolar line was used to decect the stereo pair. 3-D CFD data was used to estimate algorithm. 3-D position data of the first frame and the second frame was used to find velocity vector. Continuity equation was applied to extract error vector. The algorithm result involved error vecotor of about 0.13 %. In Pentium III 450MHz processor, the calculation time of cross-correlation for 1500 particles needed about 1 minute.

  • PDF

UKIRT Widefield Infrared Survey for [Fe II] $1.64{\mu}m$

  • 이재준;구본철
    • 천문학회보
    • /
    • 제37권2호
    • /
    • pp.97.1-97.1
    • /
    • 2012
  • NIR Emission lines from singly-ionized Iron, in particular [Fe II] $1.64{\mu}m$, are good tracer of dense atomic gas in star-forming regions, around evolved stars, and in supernova remnants. We are imaging about 180 square degrees along the Galactic Plane ($6^{\circ}$ < l < $65^{\circ}$;$-1.5^{\circ}$ < b < $+1.5^{\circ}$) with the narrow band filter centered on the [Fe II] $1.64{\mu}m$ line using WFCAM at UKIRT. The observations will complement the UWISH2 survey, which have imaged the same area with the narrow band filter centered on the molecular hydrogen 1-0 S(1) emission line at $2.12{\mu}m$, and probe a dynamically active component of ISM. We present the goals and preliminary results of our survey.

  • PDF

Blue profile in different evolutionary stages of massive star forming regions

  • Jin, Mihwa;Lee, Jeong-Eun;Kim, Kee-Tae
    • 천문학회보
    • /
    • 제40권1호
    • /
    • pp.68.1-68.1
    • /
    • 2015
  • Gravitational collapse is a dynamical process associated with star formation. One observational evidence of such infall motion is so called "blue asymmetry" profile, which is the optically thick line profile with the intensity peak skewed blueward relative to the intensity peak of optically thin lines. We analyzed both HCN J=1-0 and HNC J=1-0 line profiles to study the inflow motion in different evolutionary stages of massive star formation; Infrared dark clouds (IRDCs), High-mass protostellar object (HMPOs), and Ultra-compact HII regions (UCHIIs). The infall asymmetry in the HCN spectra seems to be more prevalent than the HNC spectra throughout all the three evolutionary phases. The prevalence of the blue profile in the HCN spectra is found in every evolutionary stage, with IRDCs showing the largest blue excess. In the case of the HNC spectra, only IRDCs show the blue excess statistically significant. These results suggest that HCN may be a better infall tracer in massive star forming region. In addition, even though the characteristics of the blue profile largely depend on the suitable combination of optical depth and critical density, our analyses also indicate that IRDCs may have the most active infall process compared to other evolutionary phases.

  • PDF

Optical Tracking of Three-Dimensional Brownian Motion of Nanoparticles

  • Choi C. K.;Kihm K.D.
    • 한국가시화정보학회지
    • /
    • 제3권1호
    • /
    • pp.3-19
    • /
    • 2005
  • Novel optical techniques are presented for three-dimensional tracking of nanoparticles; Optical Serial Sectioning Microscopy (OSSM) and Ratiometric Total Internal Reflection Fluorescent Microscopy (R-TIRFM). OSSM measures optically diffracted particle images, the so-called Point Spread Function (PSF), and dotermines the defocusing or line-of-sight location of the imaged particle measured from the focal plane. The line-of-sight Brownian motion detection using the OSSM technique is proposed in lieu of the more cumbersome two-dimensional Brownian motion tracking on the imaging plane as a potentially more effective tool to nonintrusively map the temperature fields for nanoparticle suspension fluids. On the other hand, R-TIRFM is presented to experimentally examine the classic theory on the near-wall hindered Brownian diffusive motion. An evanescent wave field from the total internal reflection of a 488-nm bandwidth of an argon-ion laser is used to provide a thin illumination field of an order of a few hundred nanometers from the wall. The experimental results show good agreement with the lateral hindrance theory, but show discrepancies from the normal hindrance theory. It is conjectured that the discrepancies can be attributed to the additional hindering effects, including electrostatic and electro-osmotic interactions between the negatively charged tracer particles and the glass surface.

  • PDF

해상도 3차원 상호상관 Volume PIV 시스템 개발 및 적용 (Development and Application of High-resolution 3-D Volume PIV System by Cross-Correlation)

  • 김미영;최장운;이현;이영호
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2002년도 학술대회지
    • /
    • pp.507-510
    • /
    • 2002
  • An algorithm of 3-D particle image velocimetry(3D-PIV) was developed for the measurement of 3-D velocity Held of complex flows. The measurement system consists of two or three CCD camera and one RGB image grabber. Flows size is $1500{\times}100{\times}180(mm)$, particle is Nylon12(1mm) and illuminator is Hollogen type lamp(100w). The stereo photogrammetry is adopted for the three dimensional geometrical mesurement of tracer particle. For the stereo-pair matching, the camera parameters should be decide in advance by a camera calibration. Camera parameter calculation equation is collinearity equation. In order to calculate the particle 3-D position based on the stereo photograrnrnetry, the eleven parameters of each camera should be obtained by the calibration of the camera. Epipolar line is used for stereo pair matching. The 3-D position of particle is calculated from the three camera parameters, centers of projection of the three cameras, and photographic coordinates of a particle, which is based on the collinear condition. To find velocity vector used 3-D position data of the first frame and the second frame. To extract error vector applied continuity equation. This study developed of various 3D-PIV animation technique.

  • PDF