• 제목/요약/키워드: Line Outage Distribution Factors

검색결과 8건 처리시간 0.021초

선로절환에 의한 과부화 해소 앨고리즘 (An Overload Alleviation Algorithm by Line Switching)

  • 박규홍;정재길
    • 대한전기학회논문지
    • /
    • 제41권5호
    • /
    • pp.459-467
    • /
    • 1992
  • This paper presents a new algorithm for the countermeasure to alleviate the line overloads due to contingency without shedding loads in a power system. This method for relieving the line overloads by line switching is based on obtaining the kine outage distribution factors-the linear sensitivity factors, which give the amount of change in the power flow of each line due to the removal of a line in a power system. There factors are made up of the elements of sparse bus reactance matrix and brach reactances. In this paper a fast algorithm and program is presented for obtaining only the required bus reactance elements which corresponds to a non-zero elements of bus admittance matrix, and elements of columns which correspond to two terminal buses of the overloaded(monitored) line. The proposed algorithm has been validated in tests on a 6-bus and the 30-bus test system.

  • PDF

전력설비의 신속한 상정사고 선택 앨고리즘 (Fast Contingency Ranking Algorithm of Power Equipment)

  • 박규홍;정재길
    • 조명전기설비학회논문지
    • /
    • 제12권1호
    • /
    • pp.20-25
    • /
    • 1998
  • 본 논문은 전력설비의 신속한 상정사고 선택을 위한 앨고리즘을 제시한다. 이 방법은 DC법에 의한 선로와 모선사이의 감도계수인 GSDF(Generation Shigt Distribution Factor)를 이용하여 계산되는 선로개방분배계수 (LODF : Line Outage Distribution Factor)를 사용하여 정상상태에서의 선로조류로부터 상정사고시의 선로조류를 계산하였다. 상정사고 선택을 신속히 하기 위하여 정상상태에서 용량대비 선로조류가 35〔%〕(154〔kV〕에서는 60〔%〕)이상의 선로만을 대상으로 하였다. 본 논문에서 제시한 앨고리즘 및 프로그램의 효율성을 입증하기 위하여 6모선 11선로 모델계통을 선정하여 적용하였다.

  • PDF

새로운 선로사고분배계수 알고리즘을 이용한 과부하 해소대책 (An Overload Alleviation Countermeasure using New Line Outage Distribution Factor)

  • 박규홍;정재길;강동구;김정하
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1995년도 하계학술대회 논문집 B
    • /
    • pp.588-590
    • /
    • 1995
  • This paper presents a new algorithm for the countermeasure to alleviate the line overloads in a power system. This method utilizes network sensitivity factors which are establised from DC load flow solutions. The line outage distribution factors(LODF) are formulated using changes in network power generations to simulate the outaged line from the network. The proposed algorithm has been validated in tests on a 6-bus test system.

  • PDF

선로사고분배계수를 이용한 상정사고 선택 (Contingency Ranking Using A Line Outage Distribution Factor)

  • 박규흥;유헌재;정재길;강영묵
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 하계학술대회 논문집 B
    • /
    • pp.760-763
    • /
    • 1996
  • This paper presents an algorithm for the contingency ranking in a power system. The method utilizes line outage distribution factors(LODF) which are established from DC load flow solutions. The LODF are formulated using changes in network power generations to simulate the outaged line from the network. To abtain better ranking. one can take a line loading of 60% over into account in the computation of PI. The proposed algorithm has been validated in tests on a 6-bus test system.

  • PDF

선로용량 산정법을 이용한 상정사고 선택 (Contigency Ranking Technique Using Line Capacity Calculation Method)

  • 박규홍;정재길;현승범;이인용;정인학
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 A
    • /
    • pp.285-288
    • /
    • 2000
  • This paper presents a technique for contingency ranting using line capacity calculation method and outage distribution factors(LODF) which are established by generation shift distribution factors from DC load flow solutions. By using the LODF, the line flow can be calculated a ccording to the modification of base load flow if the contingency occur. To obtain contingency ranting, maximum power tansferred to the load is obtained when load impedance $Z_r$ equal to line impedance $Z_s$. ( $Z_r$/ $Z_s$=1) The proposed algorithm has been validated in tests on a 6-bus test system.

  • PDF

새로운 선로용량을 고려한 전력계통의 상정사고 선택 (Contigency Ranking Technique Using New Line Capacity)

  • 박규홍;조양행
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 학술대회 논문집 전문대학교육위원
    • /
    • pp.95-98
    • /
    • 2000
  • This paper presents a technique for contingency ranking using line capacity calculation method and outage distribution factors (LODF) which are established by generation shift distribution factors from DC load flow solutions. By using the LODF, the line flow can be calculated a ccording to the modification of base load flow if the contingency occur. To obtain contingency ranking, maximum power tansferred to the load is obtained when load impedance $Z_r$ equal to line impedance $Z_s$. The proposed algorithm has been validated in tests on a 6-bus test system.

  • PDF

전력계통(電力系統)의 상정(想定)사고(事故)에 따른 선로(線路)의 과부하(過負荷) 해소(解消) 대책(對策) (The Alleviation Countermeasures of Line Overloads Due To a Contingency Occured in Power System)

  • 정제길;노신홍;박규홍
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1991년도 하계학술대회 논문집
    • /
    • pp.432-436
    • /
    • 1991
  • This paper presents a new algorithm for the countermeasure to alleviate without shedding system loads the line overloads due to contingency in power system. This method for relieving by line switching is based on obtaining the line outage distribution factors - the linear sensitivity factors, which give the amount of change in the power flow of each line due to the removal of same other line in the power system. These factors are made up of the elements of Bus Reactance Matrix and branch reactances. In this paper a fast algorithm and program is presented for obtaining only the required Bus Reactance elements which corresponds to a non - zero elements of Bus Admittance Matrix and elements of columns which correspond to two terminal Buses of the overloaded(monitored) line. The proposed algorithm has been validated in tests on the 6 busbar test system

  • PDF

열적용량과 전압안정도를 고려한 ATC 계산 방법에 관한 연구 (The ATC Calculation Method with Thermal Constraints and Voltage Stability Constraints)

  • 김재현
    • 조명전기설비학회논문지
    • /
    • 제21권2호
    • /
    • pp.86-93
    • /
    • 2007
  • 본 논문은 가용송전용량(ATC)를 계산하기 위한 두 가지 빠른 계산 기법을 제안한다. 이 방법들은 선로의 열적용량한계(Thermal ATC)와 전압 안정도한계(Voltage ATC)를 제약조건으로 ATC를 계산한다. 먼저 선로의 열적용량을 고려한 방법에서는 모선의 전력 변화에 대한 선로의 조류 감도인 PTDF와 n-1 상정사고를 고려한 LODF를 이용하였으며, 전압안정도를 고려한 방법에서는 2모선 등가 시스템을 이용하여 최대 전력을 구하는 방법을 이용하였다. 제안된 방법은 IEEE 30모선 계통에 적용하였으며 그 결과를 다른 방법과 비교하여 제안된 방법의 타당성을 입증하였다.