• Title/Summary/Keyword: Linac

검색결과 302건 처리시간 0.029초

150MW 펄스 MODULATOR의 설계 및 동작특성 (Design and Operational Charcteristics of 150MW Pulse Modulator)

  • 박성수;오종석;이경태;김상희;손윤규;최관;장성덕;박상욱;남상훈;조무현;남궁원
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1992년도 하계학술대회 논문집 B
    • /
    • pp.928-930
    • /
    • 1992
  • The design beam energy of PLS(Pohang Accelerator Laboratory) Linac is 2Gev. The linac employs total 11 units of modulators and klystrons. The maximum peak output powers of the modulators are 200MW (400kV, 500A, 4.4$\mu$S flat-top, 800$\Omega$ load) to drive the klystrons which have the peak microwave power of 80MW. Prior to the development of the 200MW modulators, a prototype 150MW modulator has been constructed and tested. We have achieved output pulses of 350kV, 420A and 3.5$\mu$S flat-top with 840$\Omega$ water load. In this article, the test results and computer simulations of charging, De-Q'ing, and discharging are presented.

  • PDF

PLS 2-GeV Linac Vacuum System

  • Bak, J.S.;Namkung, W
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 1994년도 제7회 학술발표회 및 한·일 CVD 심포지움 논문개요집
    • /
    • pp.40-41
    • /
    • 1994
  • PDF

Evaluation of Treatment Plan Quality between Magnetic Resonance-Guided Radiotherapy and Volumetric Modulated Arc Therapy for Prostate Cancer

  • Chang Heon Choi;Jin Ho Kim;Jaeman Son;Jong Min Park;Jung-in Kim
    • 한국의학물리학회지:의학물리
    • /
    • 제33권4호
    • /
    • pp.121-128
    • /
    • 2022
  • Purpose: This study evaluated the quality of plans based on magnetic resonance-guided radiotherapy (MRgRT) tri-Co-60, linac, and conventional linac-based volumetric modulated arc therapy (linac-VMAT) for prostate cancer. Methods: Twenty patients suffering from prostate cancer with intermediate risk who were treated by MAT were selected. Additional treatment plans (primary and boost plans) were generated based on MRgRT-tri-Co-60 and MRgRT-linac. The planning target volume (PTV) of MRgRT-based plans was created by adding a 3 mm margin from the clinical target volume (CTV) due to high soft-tissue contrast and real-time motion imaging. On the other hand, the PTV of conventional linac was generated based on a 1 cm margin from CTV. The targets of primary and boost plans were prostate plus seminal vesicle and prostate only, respectively. All plans were normalized to cover 95% of the target volume by 100% of the prescribed dose. Dosimetric characteristics were evaluated for each of the primary, boost, and sum plans. Results: For target coverage and conformity, the three plans showed similar results. In the sum plans, the average value of V65Gy of the rectum of MRgRT-linac (2.62%±2.21%) was smaller than those of MRgRT tri-Co-60 (9.04%±3.01%) and linac-VMAT (9.73%±7.14%) (P<0.001). In the case of bladder, the average value of V65Gy of MRgRT-linac was also smaller. Conclusions: In terms of organs at risk sparing, MRgRT-linac shows the best value while maintaining comparable target coverage among the three plans.

Conceptual Design of the Superconducting Linac for KOMAC

  • Kim, Sang-Ho;Kim, Young-Hwan;Kim, Han-Sung;Lee, Kang ok;Chung, Kie-Hyung
    • 한국원자력학회:학술대회논문집
    • /
    • 한국원자력학회 1998년도 춘계학술발표회논문집(2)
    • /
    • pp.967-971
    • /
    • 1998
  • KOMAC (KOrea Multi-purpose Accelerator Complex) is the 1 Gev, 20 ㎃ proton linac. The superconducting linac for the high energy part acceleration from 100 MeV to 1 GeV is selected as a main candidate. As is well known, the superconducting linac has advantages for high current, high energy acceleration such as a large bore size, short accelerator length, and the RF efficiency. In this energy, the velocity of proton increases from $\beta$=0.87. For the design and fabrication simplicity, the cavity $\beta$ stages are divided into 3 parts. The maximum electric field in the cavity is designed below 20 ㎹/m. In this paper the design concepts and guides for this superconducting linac are introduced.

  • PDF

방사선 치료를 위한 의료용 선형 전자가속기에 대한 실증연구 (Empirical Study on Medical LINAC System for Radiation Therapy)

  • 박수미;송승호;조현빈;정우철;장성록;류홍제
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2019년도 전력전자학술대회
    • /
    • pp.242-244
    • /
    • 2019
  • 본 논문은 방사선 치료에 사용되는 선형 전자가속기(LINAC)의 작동 원리와 구성 등 의료용 LINAC의 전반을 다룬다. 의료용 LINAC은 전자총에서 발사된 전자를 가속기 튜브 내에서 가속시켜 전자빔을 발생시키고, 이러한 전자빔을 금속 표적에 충돌시켜 발생한 X 선을 인체에 조사하는 원리이다. 최근에는 O-arm, C-arm 등 3-D 촬영을 위한 치료기가 개발됨에 따라, 의료용 LINAC의 전자총, 마그네트론 등을 구동하는데 사용되는 고전압 전원장치 또한 소형화와 고밀도화가 요구되는 추세이다. 본 논문에서는 마그네트론 구동을 위한 고밀도 40kV/100A 음극성 펄스 모듈레이터와 정전압 정전류 제어 및 50kV 절연이 가능한 히터 전원장치를 설계 및 제작하였으며, 9.3GHz, 1.7MW X-Band 마그네트론 연계실험을 통해 고효율 고신뢰성의 동작을 확인하였다.

  • PDF

SRF LINAC FOR FUTURE EXTENSION OF THE PEFP

  • Kim, Han-Sung;Kwon, Hyeok-Jung;Seol, Kyung-Tae;Jang, Ji-Ho;Cho, Yong-Sub
    • Nuclear Engineering and Technology
    • /
    • 제46권2호
    • /
    • pp.247-254
    • /
    • 2014
  • A study on the superconducting RF linac is underway in order to increase the beam energy up to 1 GeV by extending the Proton Engineering Frontier Project (PEFP) 100-MeV linac. The operating frequency of the PEFP superconducting linac (SCL) is 700 MHz, which is determined by the fact that the frequency of the existing normal conducting linac is 350 MHz. A preliminary study on the beam dynamics showed that two types of cavities with geometrical betas of 0.50 and 0.74 could cover the entire energy range from 100 MeV to 1 GeV. An inductive output tube (IOT) based RF system is under consideration as a high-power RF source for the SCL due to its low operating voltage and high efficiency. As a prototyping activity for a reduced beta cavity, a five-cell cavity with a geometrical beta of 0.42 was designed and fabricated. A vertical test of the prototype cavity at low temperatures was performed to check the performance of the cavity. The design study and the prototyping activity for the PEFP SCL will be presented in this paper.

Measurement of undesirable neutron spectrum in a 120 MeV linac

  • Yihong Yan ;Xinjian Tan;Xiufeng Weng ;Xiaodong Zhang ;Zhikai Zhang ;Weiqiang Sun ;Guang Hu ;Huasi Hu
    • Nuclear Engineering and Technology
    • /
    • 제55권10호
    • /
    • pp.3591-3598
    • /
    • 2023
  • Photoneutron background spectroscopy observations at linac are essential for directing accelerator shielding and subtracting background signals. Therefore, we constructed a Bonner Sphere Spectrometer (BSS) system based on an array of BF3 gas proportional counter tubes. Initially, the response of the BSS system was simulated using the MCNP5 code. Next, the response of the system was calibrated by using neutrons with energies of 2.86 MeV and 14.84 MeV. Then, the system was employed to measure the spectrum of the 241Am-Be neutron source, and the results were unfolded by using the Gravel and EM algorithms. Using the validated system, the undesirable neutron spectrum of the 120 MeV electron linac was finally measured and acquired. In addition, it is demonstrated that the equivalent undesirable neutron dose at a distance of 3.2 m from the linac is 19.7 mSv/h. The results measured by the above methods could provide guidance for linac-related research.

듀얼 헤드 갠트리 방사선치료 시스템 설계를 위한 몬테칼로 시뮬레이션 연구 (Modeling of Dual Head Gantry Radiotherapy System with Monte Carlo Simulation)

  • 박승우
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제40권4호
    • /
    • pp.627-632
    • /
    • 2017
  • 듀얼 헤드 갠트리(dual-head) 갠트리 방사선치료 시스템을 설계하기 위해 LINAC의 단일 헤드는 GATE를 예비 연구로 사용하여 모델링되었다. LINAC 헤드는 임상에서 사용되고 있는 VARIAN사를 대상으로 모델링되었다. LINAC 헤드에서 생성된 6MV의 광자선을 물 팬텀에 조사하여 빔의 특성을 평가하였다. GATE 시뮬레이션은 X- 선 스펙트럼을 생성한 후 물 팬텀에 광자선을 조사하였다. 결과로는 백분율 깊이 선량 과 빔의 프로파일을 평가하였으며, $5{\times}5$$10{\times}10cm^2$에서 수행하였다. 빔 품질이 검증 된 후 듀얼 헤드 갠트리(dual head gantry) 방사선치료 시스템을 시뮬레이션 한 후 팬텀(phantom)을 이용한 선량 분포 측면에서 LINAC 시스템의 단일 헤드와 비교하였다. 듀얼 헤드 갠트리 방사선치료 시스템은 단일 헤드 방사선치료 시스템에 비해 방사선치료의 효율 면에서 40~60% 높은 것을 확인할 수 있었으며, 듀얼 헤드 방사선치료 시스템은 방사선치료 및 치료시간을 줄일 수 있을 것이 사료된다.

고 에너지 방사선에 기인된 방사선치료실 내 평균 오존 농도의 변화 (Variation of Indoor Average Ozone Concentration within the Radiation Therapy Room by High Energy Radiation)

  • 이진국;이효영;임인철;유윤식
    • 한국방사선학회논문지
    • /
    • 제10권3호
    • /
    • pp.171-180
    • /
    • 2016
  • 본 연구는 고 에너지 방사선 조사에 기인된 방사선치료실 내 오존 농도의 변화를 비교 분석하고자 하였다. 이를 위하여 치료실 주변 대기 중 오존 농도와 치료실 내 배경 오존 농도를 분석하여 고 에너지 방사선 조사에 기인된 치료실 내 평균 오존 농도를 비교하였다. 치료실 내 배경 오존 농도는 평균 $17.4{\pm}7.9ppb$로 방사선치료실 주변의 대기 중 오존 농도(평균 $36.8{\pm}22.3ppb$)보다 약 50% 정도 통계적으로 유의하게 낮게 나타났다(p<0.05). 고 에너지 방사선 조사에 기인된 치료실 내 오존 농도는 방사선이 조사됨과 동시에 배경 오존 농도의 약 2배 수준으로 급격하게 증가되었으며 조사시간이 증가함에 따라 기울기가 일정한 증가 추이를 보이다가 약 130초에서 180초 부근에서 최대 오존 농도를 이루고 점차 포화되는 경향을 보였으며 배경 오존 농도로 감소하는데 소요되는 시간은 약 10분 이상이었다. 본 연구 결과를 토대로 고 에너지 방사선 조사에 기인된 방사선치료실 내 오존 농도는 후각을 자극하는 오존의 특이한 냄새를 맡거나 순간적인 호흡 곤란과 마른기침으로 가슴 통증 등의 신체적 증상이 나타날 수 있는 수준으로 밀폐된 방사선치료실에서 고농도 오존에 장시간 노출될 경우 폐 질환을 악화시킬 수 있기 때문에 각별한 주의가 요구된다.