• Title/Summary/Keyword: Limiting efficiency

Search Result 259, Processing Time 0.034 seconds

Comparative Study on the Efficiency of the Gas Discharge Lasers - Limiting Efficiency of Metal Vapor Lasers - (기체방전 레이저의 효율에 관한 연구 -금속증기레이저의 한계효율-)

  • 이재경
    • Korean Journal of Optics and Photonics
    • /
    • v.4 no.1
    • /
    • pp.47-56
    • /
    • 1993
  • Practical efficiencies of pulsed gas discharge lasers utilizing vaporized Au, Ba, Cu, Fe, Mn, Pb, TI atoms are numerically optimized for a discharge pulse of 30 ns rise time at 5 kHz pulse repetition rate. Calculated optimum operating temperatures are close to the values at which the vapor pressure of each atom is about 1 Torr and are in good agreement with experimental values reported elasewhere. The optimum charging voltage was about 4 kV for all atomic vapor lasers except the TI laser. The calculated maximum efficiencies that have been discussed for possible limiting efficiencies for each laser were considerably higher than the reported experimental values. Especially, they were as high as 6.8% for Mn laser and 15% for Ba laser that were comparable to the 8.5% of copper vapor laser, from which considerably higher efficiencies can be expected for these two lasers experimentally. But, the present calculation shows a very low efficiency of 0.058% and requires an exceptional operating condition for the TI laser.

  • PDF

Electrodeposition behaviors of zinc from neutral chloride baths at high current density (중성염화물욕에서 아연의 고전류밀도 전착특성)

  • 김영근
    • Journal of the Korean institute of surface engineering
    • /
    • v.29 no.4
    • /
    • pp.219-228
    • /
    • 1996
  • Neutral Zinc Electroplating(NZE) utilizing the electrolyte of pH 6 to 8 has advantages in waste treatment and the protection of equipment. NZE is beneficially used in chromating treatment, but the limiting current density and the current efficiency are low. Therefore this study is investigated to analyse the characteristics of NZE and to obtain high current density and current efficiency. The deposition potential of zinc in the NZE bath is about 110mV, which is lower than acidic bath. The current density possibily increases up to 60A/d$\m^2$ in lower complexing agent content and pH 6. More than 90% of cathodic current efficiency was obtained in NZE bath. The NZE morphology shows smaller grains than acidic bath. The addition of 4$m\ell$/1 second brightener gives finer morphology. As pH becomes higher, (002) plan decreases and (100), (101) and (110) planes increase in the no additives solution.

  • PDF

The Efficiency of Conditional MLE for Pure Birth Processes

  • Yoon, Jong-Ook;Kim, Joo-Hwan
    • Proceedings of the Korean Reliability Society Conference
    • /
    • 2002.06a
    • /
    • pp.367-386
    • /
    • 2002
  • The Present paper is devoted to a study of the performance, in large samples, of a conditional maximum likelihood estimator(CMLE) for the parameter ${\lambda}$ in a pure birth processes(PBP). To conduct the conditional inference for the PBP, we drove the likelihood function of time-inhomogeneous Poisson processes. The limiting distributions of CMLE under the likelihoods $L_{t}$ or $\overline{L_{t}}$ are investigated. We found that the CMLE is asymptotically efficient with respect to the both $L_{t}$ or $\overline{L_{t}}$ under the efficiency criterion of Weiss & Wolfowitz(1974).

  • PDF

Testing Harmonic Used Better than Aged in Expectation in Upper Tail(HUBAEUT) Class of Life Distributions Using Kernel Method

  • Abu-Youssef, S.E.;Al-nachawati, H.
    • International Journal of Reliability and Applications
    • /
    • v.7 no.2
    • /
    • pp.89-99
    • /
    • 2006
  • A new classes of life distribution, namely harmonic used better than aged in expectation in upper tail (HUBAEUT) is introduced. Testing exponentiality against this class is investigated using kernel method. The limiting null and nonnull distribution of the test statistics is normal and the null variance is calculated exactly. Selected critical values are tabulated for sample sizes of 5(1)40. Power of the test are estimated by simulation. the efficacies of the test statistics used for testing against HUBAEUT are calculated for som common alternatives and are compared to some other procedures. It is shown that proposed test is simple, has high relative efficiency and power for some commonly used alternatives. The set of real data are used as an examples to elucidate the use of the proposed test statistics for practical reliability.

  • PDF

Cleaning agents efficiency in cleaning of polymeric and ceramic membranes fouled by natural organic matter

  • Urbanowska, Agnieszka;Kabsch-Korbutowicz, Malgorzata
    • Membrane and Water Treatment
    • /
    • v.7 no.1
    • /
    • pp.1-10
    • /
    • 2016
  • Ultrafiltration is known to be one of the most commonly applied techniques in water treatment. Membrane fouling is the main limiting factor in terms of process efficiency and restricting it to the manageable degree is crucial. Natural organic matter is often found to be a major foulant in surface waters. Among many known fouling prevention techniques, the membrane chemical cleaning is widely employed. This study focuses on evaluating the cleaning efficiency of polymeric and ceramic membranes with the use of various chemicals. The influence of cleaning agent type and its concentration, membrane material and its MWCO, and cleaning process duration on the recovery of membrane flux was analyzed. Results have shown that, regardless of membrane type and MWCO, the most effective cleaning agent was NaOH.

Efficiency Evaluation of a Hybrid Propulsion Fuel Cell Ship Based on AIS Data (항적 데이터에 기반한 하이브리드 추진 연료전지 선박의 효율 평가)

  • Donghyun Oh;Dae-Seung Cho
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.60 no.3
    • /
    • pp.146-154
    • /
    • 2023
  • Efforts have been made to reduce the greenhouse gas emissions from ships by limiting the energy efficiency index, and net zero CO2 emission was proposed recently. The most ideal measure to achieve zero emission ship is electrification, and fuel cells are considered as a practical power source of the electrified propulsion system. The electric efficiency in the electrochemical reaction of fuel cells can be achieved up to 60% practically. The remaining energy is converted to heat energy but most of them are dissipated by cooling. In the author's previous research, a hybrid propulsion system utilizing not only electricity but also heat was introduced by combining electric motor and steam turbine. In this article, long term efficiency is evaluated for the introduced hybrid propulsion system by considering a virtual 24,000 TEU class container carrier model. To reflect a more practical operating condition, the actual navigation data of a similar real ship in the real world were collected from automatic identification system data and applied. From the result, the overall efficiency of the hybrid propulsion system is expected to be higher than a conventional electric propulsion fuel cell ship by 30%.

A study on the evaluation of phosphate removal efficiency using Fe-coated silica sand (철 코팅 규사의 인산이온 제거 효율 평가 연구)

  • Jo, Eunyoung;Kim, Younghee;Park, Changyu
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.31 no.6
    • /
    • pp.521-527
    • /
    • 2017
  • Phosphorus is one of the limiting nutrients for the growth of phytoplankton and algae and is therefore one of leading causes of eutrophication. Most phosphorous in water is present in the form of phosphates. Different technologies have been applied for phosphate removal from wastewater, such as physical, chemical precipitation by using ferric, calcium or aluminum salts, biological, and adsorption. Adsorption is one of efficient method to remove phosphates in wastewater. To find the optimal media for phosphate removal, physical characteristics of media was analysed, and the phosphate removal efficiency of media (silica sand, slag, zeolite, activated carbon) was also investigated in this study. Silica sand showed highest relative density and wear rate, and phosphate removal efficiency. Silica sand removed about 36% of phosphate. To improve the phosphate removal efficiency of silica sand, Fe coating was conducted. Fe coated silica sand showed 3 times higher removal efficiency than non-coated one.

Analysis of Fabrication and Characterization of free-Hg fluorescent lamp for LCD Backlight (LCD Backlight 용 무수은 형광램프의 제작 및 특성 분석)

  • 이휘철;임성규
    • Proceedings of the IEEK Conference
    • /
    • 2000.11b
    • /
    • pp.237-240
    • /
    • 2000
  • It is expected that there will be the regulation for limiting the amount of Hg content in cold cathode fluorescent lamp (CCFL) for LCD backlight system. Now it is necessary to develop mercury-free backlight system. The mercury-free CCFL coated with PDP phosphors was fabricated and evaluated. The CCFL filled with Xe and Ne showed 4500 ㏅/$m^2$ with efficiency of 13 lm/W.

  • PDF

On the Study for the Simultaneous Test

  • Park, Hyo-Il
    • Communications for Statistical Applications and Methods
    • /
    • v.20 no.4
    • /
    • pp.241-246
    • /
    • 2013
  • In this study, we propose a nonparametric simultaneous test procedure for the location translation and scale parameters. We consider the Wilcoxon rank sum test for the location translation parameter and the Mood test for the scale parameter with the quadratic and maximal types of combining functions. Then we derive the limiting null distributions of the combining functions. We illustrate our procedure with an example and compare efficiency by obtaining the empirical powers through a simulation study. Finally, we discuss some interesting features related to the nonparametric simultaneous tests.

Asymptotic Properties of LAD Esimators of a Nonlinear Time Series Regression Model

  • Kim, Tae-Soo;Kim, Hae-Kyung;Park, Seung-Hoe
    • Journal of the Korean Statistical Society
    • /
    • v.29 no.2
    • /
    • pp.187-199
    • /
    • 2000
  • In this paper, we deal with the asymptotic properties of the least absolute deviation estimators in the nonlinear time series regression model. For the sinusodial model which frequently appears in a time series analysis, we study the strong consistency and asymptotic normality of least absolute deviation estimators. And using the derived limiting distributions we show that the least absolute deviation estimators is more efficient than the least squared estimators when the error distribution of the model has heavy tails.

  • PDF