• 제목/요약/키워드: Limited Current

검색결과 2,678건 처리시간 0.028초

고온 초전도 마그넷의 선재에서 발생되는 자장과 전계 해석 (Magnetic Field and Electric Field Generated in an HTS Tape of a High Temperature Superconducting Magnet)

  • 김영민;구명환;차귀수;전창완;백경호
    • 전기학회논문지
    • /
    • 제60권4호
    • /
    • pp.753-758
    • /
    • 2011
  • Magnetic field and Electric field of High Temperature Superconducting magnet are very important to analysis of superconducting magnet. The maximum perpendicular magnetic field was applied to the outermost pancake windings. The critical current of all the magnet windings is limited by the critical current of the outermost pancake windings. The E-J relation was used to determine the critical current, and an evolution s trategy was adopted for the optimization of gap length between each pancake windins. The results of calculations show that the critical current and the central magnetic field and uniformity increased by 82.6% and 31.6% and 50.8%, respectively, for a magnet consisting of ten pancake windings. This paper did an analysis the cause of increase the critical current and central magnetic field and uniformity in no gap and optimal gap model.

휴대용 이차전지 보호 시스템용 전류 감지 동작형 보호소자의 퓨즈 가용체 설계 (Design of Fuse Elements of Current Sensing Type Protection Device for Portable Secondary Battery Protection System)

  • 강창룡;김은민
    • 전기학회논문지
    • /
    • 제67권12호
    • /
    • pp.1619-1625
    • /
    • 2018
  • Portable electronic devices secondary batteries can cause fire and explosion due to micro-current change in addition to the situation of short-circuit inrush current, safety can not be secured with a general operation limited current fuse. Therefore, in secondary battery, it is necessary for the protector to satisfy both the limit current type operation in the open-short-circuit inrush current and the current detection operation characteristic in the micro current change situation and for this operation, a fuse for the current detection type secondary battery protection circuit can be applied. The purpose of this study is to design a protection device that operates stably in the hazardous situation of small capacity secondary battery for portable electronic devices through the design of low melting fuse elements alloy of sensing type fuse and secures stability in abnormal current state. As a result of the experiment, I-T and V-T operation characteristics are satisfied in a the design of the alloy of the current sensing type self-contained low melting point fuse and the resistance of the heating resistor. It is confirmed that it can prevent accidents of short circuit over-current and micro current change of secondary battery.

Surface Current Fields in the Eastern East China Sea

  • Lie, Heung-Jae;Cho, Cheol-Ho
    • Journal of the korean society of oceanography
    • /
    • 제32권1호
    • /
    • pp.1-7
    • /
    • 1997
  • Surface current fields in the eastern East China Sea (ECS) were constructed by analyzing trajectories of 58 satellite-tracked surface drifters released during 1991-1996. Composite trajectories and 20-minute-by-20-minute box-averaged current vectors show that the basic current pattern composes of: the Kuroshio main stream, which turns eastward toward the Tokara Strait; a northward branch current of the Kuroshio on the ECS outer shelf deeper than 100 m; and an anticyclonic circulation in the northern Okinawa Trough west of Kyushu. The northward branch current sharply changes its direction to the northeast when it crosses a line connecting Cheju Island, Korea and Goto Islands, Japan. The basic pattern of current field changes slightly from winter to summer, and the main axis of the Tsushima Current in the Korea Strait is found to shift seasonally. The drifter experiment does not support the claim that the Yellow Sea Warm Current is separated from the northward branch current on the outer shelf southeast of Cheju Island. We suggest that the use of the term 'Tsushima Current' be limited to the northeast channel flow in the Korea Strait. The new term 'Kuroshio Branch Current' is suggested for the northward branch current on the outer shelf south of Cheju-do, which is separated from the Kuroshio.

  • PDF

공익사업에 따른 어업피해 관련 한정어업면허에 대한 문제점 및 개선방안에 관한 연구 (A Study on the Problems and Improvement Measures of Licenses for Limited Fishery Business Related to Fisheries Damage due to Public Works Projects)

  • 류승우;윤은찬;강경아
    • 수산경영론집
    • /
    • 제55권1호
    • /
    • pp.21-35
    • /
    • 2024
  • In this study, we collected and analyzed the current status of licenses for the limited fishery business and divided the problems related to licenses for the limited fishery business into partial damage compensation and cancellation compensation areas. In the case of partial damage compensation areas due to existing public water use projects, it is suggested that the issuance of licenses for limited fishery businesses should be reconsidered. In the case of cancellation compensation areas, it is recommended that the disposition of communal fishery businesses that do not require capital investment should be the principle. If capital such as facilities are invested, compensation should be made by Article 52 of the Enforcement Decree of the Land Compensation Act if the licenses for limited fishery business are closed due to other development projects. In addition, we proposed an improvement plan to establish a rational management system for licenses for limited fishery businesses. In addition to these improvement measures, we hope that further investigation and research on licenses for limited fishery business, which have been insufficient so far, will be conducted to promote the comprehensive use of fisheries resources and waters and the sustainable development of fisheries that are the objectives of the Fisheries Act, and contribute to the improvement of the quality of life of the people and the balanced development of the national economy.

고속 인터럽터를 적용한 한류기의 전류제한요소에 따른 특성 (Characteristics of a FCL Applying Fast Interrupter According to the Current Limitation Elements)

  • 임인규;최효상;정병익
    • 전기학회논문지
    • /
    • 제61권11호
    • /
    • pp.1752-1757
    • /
    • 2012
  • With the development in industry, power demand has increased rapidly. As consumption of power has increased, Demand for new power line and electric capacity has risen. However, in the event of fault, problems occur in extending the range of fault coverage and increasing fault current. In these reasons, protection devise is recognized as the prevention of an accident and fault current. This paper dealt with minimizing fault propagation and limiting fault current by adjusting fault current limiter (FCL) with fast interrupter. At this point, we compared and analyzed characteristics between non-inductive resistance and fault current which is limited by superconducting units. In normal state of the power system, power was supplied to the load, but when fault occurred, the interrupter was operated as CT which detected the over-current. Its operation made the limitation of fault current through a FCL. We concluded that the limiter using superconducting units was more efficient with the increase of power voltage. Superconducting fault current limiter with the fast interrupter prevented the spread of a fault, and improved reliability of power system.

The Analysis of Current Limiting Performance in a High-$T_c$ Superconductor using Flux-Lock Concepts

  • 임성훈;최효상;김영순;이성룡;한병성
    • Progress in Superconductivity
    • /
    • 제3권2호
    • /
    • pp.229-234
    • /
    • 2002
  • In this paper, we analyzed the fault current performance in a $high-T_{c}$ superconductor(HTS) which was installed on flux-lock reactor with an external magnetic field coil covering the HTS. In this HTS fault current limiter using flux-lock concepts, the initial limiting current level can be controlled by adjusting the inductance of the coils. Furthermore, the current limiting characteristics of $high-T_{c}$ superconducting FCL can be improved by applying the external magnetic field into the $high-T_{c}$ superconductor. This paper discusses current limiting performance according to the inductance of the coil 1 in two cases with ac magnetic field coil or not and suggests the methods to improve the current limiting factor $P_{limit}$, which is defined as the ratio of the limited current $I_{FCL}$ at the current limiting phase to the prospective short -circuit current $I_{PSC}$.TEX> PSC/.

  • PDF

6 직렬 연결된 ITER VS 컨버터의 시퀀스제어 비교 해석 (Comparative Analysis of Sequence Control in Six Series-Connected ITER VS Converters)

  • 조현식;정진용;조종민;차한주
    • 전력전자학회논문지
    • /
    • 제19권5호
    • /
    • pp.399-406
    • /
    • 2014
  • This study investigates the structure and operation of the ITER VS converter and proposes a sequence control method for six series-connected VS converters to reduce reactive power. The operation and the proposed sequence control method are verified through RTDS simulation. The ITER VS converter must supply voltage/current to the superconducting magnets for plasma current vertical stabilization, and the four-quadrant operation must proceed without a zero-current discontinuous section. The operation mode of the VS converter is separated into a 12- and 6-pulse circulating current and transition modes according to the size of the load current. The output voltage of the unit VS converter is limited because of the rated voltage; however, the superconducting coil must increase the operating output voltage. Thus, the VS converter must be connected in a 6-series to provide the required operating output voltage. The output voltage of the VS converters is controlled continuously; however, reactive power is limited within a minimized value of the grid. In this study, the unit converter is compared with converters connected in a 6-series to determine a suitable sequence control method. The output voltage is the same in all cases, but the maximum reactive power is reduced from 100% to 73%. This sequence control method is verified through RTDS simulation.

비-휘발성 저항 변화 메모리 응용을 위한 WOx 물질의 전기적 특성 연구 (A Study of the Electrical Characteristics of WOx Material for Non-Volatile Resistive Random Access Memory)

  • 정균호;김경민;송승곤;박윤선;박경완;석중현
    • 한국전기전자재료학회논문지
    • /
    • 제29권5호
    • /
    • pp.268-273
    • /
    • 2016
  • In this study, we observed current-voltage characteristics of the MIM (metal-insulator-metal) structure. The $WO_x$ material was used between metal electrodes as the oxide insulator. The structure of the $Al/WO_x/TiN$ shows bipolar resistive switching and the operating direction of the resistive switching is clockwise, which means set at negative voltage and reset at positive voltage. The set process from HRS (high resistance state) to LRS (low resistance state) occurred at -2.6V. The reset process from LRS to HRS occurred at 2.78V. The on/off current ratio was about 10 and resistive switching was performed for 5 cycles in the endurance characteristics. With consecutive switching cycles, the stable $V_{set}$ and $V_{reset}$ were observed. The electrical transport mechanism of the device was based on the migration of oxygen ions and the current-voltage curve is following (Ohm's Law ${\rightarrow}$ Trap-Controlled Space Charge Limited Current ${\rightarrow}$ Ohm's Law) process in the positive voltage region.

자속구속형 고온초전도 전류제한기의 동작전류와 각 코일의 전류분류 분석 (Analysis on Operational Current and Current Distribution between Two Coils of flux-lock Type SFCL)

  • 박충렬;임성훈;박형민;최효상;한병성
    • 한국전기전자재료학회논문지
    • /
    • 제18권8호
    • /
    • pp.753-758
    • /
    • 2005
  • A flux-lock type superconducting fault current limiter(SFCL) consists of two coils, which are wound in parallel each other through an iron core, and a high-$T_c$ Superconducting(HTSC) thin film connected in series with coil 2. If the current of the HTSC thin film exceeds its critical current by the fault accident, the resistance of the HTSC thin film generated, and thereby the fault current can be limited by the impedance of the fluk-lock type SFCL. In this paper, we investigated the dependence of both the fault current limiting characteristics and the current distribution between two coils on the operational current of the flux-lock type SFCL through the equivalent circuit analyses and short circuit tests. From the comparison of both the results, the experimental results well agreed with the analyses for equivalent circuit.

Case studies in steel and composite design

  • Vesey, D.G.;Kwan, K.K.;Xu, L.
    • Steel and Composite Structures
    • /
    • 제5권2_3호
    • /
    • pp.247-258
    • /
    • 2005
  • This paper outlines the current steel design climate and describes some recent and unusual designs using structural steel or composite steel and concrete which have been carried out in Hong Kong and the East Asia region. Composite structural systems for very tall buildings are outlined. A case study of concept designs for one of these is presented. Two further case studies are presented: a refurbishment project where the use of steel and innovative strengthening techniques allowed an additional five stories to be built on an existing reinforced concrete frame and a monumental sculpture.