• Title/Summary/Keyword: Limitation

Search Result 8,489, Processing Time 0.043 seconds

Usability index evaluation system for mobile WAP service (무선인터넷 서비스 사용성 지수 평가 체계)

  • Park, Hwan-Su
    • 한국HCI학회:학술대회논문집
    • /
    • 2008.02b
    • /
    • pp.152-157
    • /
    • 2008
  • The customer satisfaction of WAP service greatly relies on the usability of the service due to the limited display size of a mobile phone and limitation in realizing UI (User Interface) for function keys, browser, and OS (operating system) Currently, a number of contents providers develop and deliver varying services, and thus, it is critical to control quality level of UI in consistent standards and manner. This study suggests usability index evaluation system to achieve consistent UI quality control of various WAP services. The system adopts both top-down and bottom-up approaches. The former concerns deriving UI design components and evaluation checklists for the WAP, based on the usability attributes and UI principles. The latter concerns deriving usability-related evaluation checklists from the established UI design features, and then grouping them from the viewpoint of usability principles and attributes. This bidirectional approach has two outstanding advantages: it allows thorough examination of potential elements that can cause usability problems from the standpoint of usability attributes, and also derives specific evaluation elements from the perspective of UI design components that are relevant to the real service environment. The evaluation system constitutes a hierarchical structure by networking usability attributes, UI guideline which indicates usability principles for each attribute, and usability evaluation checklist for each UI component that enables specific evaluation. Especially, each evaluation checklist contains concrete contents and format so that it can be readily marked in O/X. The score is based on the ratio of number of items that received positive answer to the number of total items. This enables a quantitative evaluation of the usability of mobile WAP service. The validity of the proposed evaluation system has been proved through comparative analysis with the real usability problems based on the user test. A software was developed that provides guideline for evaluation objects, criteria and examples for each checklist, and automatically calculates a score. The software was applied to evaluating and improving the real mobile WAP service.

  • PDF

Application of CMP Process to Improving Thickness-Uniformity of Sputtering-deposited CdTe Thin Film for Improvement of Optical Properties (스퍼터링 증확 CdTe 박막의 두께 불균일 현상 개선을 위한 화학적기계적연마 공정 적용 및 광특성 향상)

  • Park, Ju-Sun;Lim, Chae-Hyun;Ryu, Seung-Han;Myung, Kuk-Do;Kim, Nam-Hoon;Lee, Woo-Sun
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2010.06a
    • /
    • pp.375-375
    • /
    • 2010
  • CdTe as an absorber material is widely used in thin film solar cells with the heterostructure due to its almost ideal band gap energy of 1.45 eV, high photovoltaic conversion efficiency, low cost and stable performance. The deposition methods and preparation conditions for the fabrication of CdTe are very important for the achievement of high solar cell conversion efficiency. There are some rearranged reports about the deposition methods available for the preparation of CdTe thin films such as close spaced sublimation (CSS), physical vapor deposition (PVD), vacuum evaporation, vapor transport deposition (VTD), closed space vapor transport, electrodeposition, screen printing, spray pyrolysis, metalorganic chemical vapor deposition (MOCVD), and RF sputtering. The RF sputtering method for the preparation of CdTe thin films has important advantages in that the thin films can be prepared at low growth temperatures with large-area deposition suitable for mass-production. The authors reported that the optical and electrical properties of CdTe thin film were closely connected by the thickness-uniformity of the film in the previous study [1], which means that the better optical absorbance and the higher carrier concentration could be obtained in the better condition of thickness-uniformity for CdTe thin film. The thickness-uniformity could be controlled and improved by the some process parameters such as vacuum level and RF power in the sputtering process of CdTe thin films. However, there is a limitation to improve the thickness-uniformity only in the preparation process [1]. So it is necessary to introduce the external or additional method for improving the thickness-uniformity of CdTe thin film because the cell size of thin film solar cell will be enlarged. Therefore, the authors firstly applied the chemical mechanical polishing (CMP) process to improving the thickness-uniformity of CdTe thin films with a G&P POLI-450 CMP polisher [2]. CMP process is the most important process in semiconductor manufacturing processes in order to planarize the surface of the wafer even over 300 mm and to form the copper interconnects with damascene process. Some important CMP characteristics for CdTe were obtained including removal rate (RR), WIWNU%, RMS roughness, and peak-to-valley roughness [2]. With these important results, the CMP process for CdTe thin films was performed to improve the thickness-uniformity of the sputtering-deposited CdTe thin film which had the worst two thickness-uniformities of them. Some optical properties including optical transmittance and absorbance of the CdTe thin films were measured by using a UV-Visible spectrophotometer (Varian Techtron, Cary500scan) in the range of 400 - 800 nm. After CMP process, the thickness-uniformities became better than that of the best condition in the previous sputtering process of CdTe thin films. Consequently, the optical properties were directly affected by the thickness-uniformity of CdTe thin film. The absorbance of CdTe thin films was improved although the thickness of CdTe thin film was not changed.

  • PDF

Clinical Comparison of Immediately Loaded and Delayed Loaded OSSTEM GS III Implant in Partially Edentulous Patients (자연치 부분 결손 환자에서 테이퍼 형태의 국산 임플란트(OSSTEM GS III)의 즉시하중 성공률에 대한 지연하중군과의 비교 임상연구)

  • Kwon, Min-Jung;Kim, Young-Kyun;Yeo, In-Sung;Yi, Yang-Jin
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.27 no.3
    • /
    • pp.267-275
    • /
    • 2011
  • This prospective study was designed to compare clinical outcomes of immediately loaded implant with delayed loaded implant in partially posterior edentulous patients. For test group, 42 GS III (Osstem, Korea) implants in 17 patients were loaded within 48 hours after the placement. Control group was 27 implants in 15 patients loaded at $2.6{\pm}1.7months$ from the placement surgery. Before loading, primary stability was evaluated by ISQ value. Clinical symptoms, mobility, soft tissue state was evaluated at baseline, 3 months, 6 months and 12 months of loading. Marginal bone level change was also measured with periapical radiographs. Mann-Whitney test (${\alpha}$=0.05) and repeated measured ANOVA (${\alpha}$=0.05) was used for marginal bone level change between two groups. At the baseline, mean ISQ value of test group and control group was $80.3{\pm}7.1$ and $69{\pm}17$ respectively. Test group showed 95.23% of success rate and 100% of control group was successful. At 3 and 6months of loading, significantly more bone resorption was observed in test group than in control group (p<0.05). However, there was no significant difference in the bone level change at 12months of loading between two groups (p>0.05). Marginal bone level change showed no significant difference with gender and location (p>0.05). Within the limitation of this study, when primary stability was obtained, immediate loading of GS III implant at posterior region could be predictable treatment option.

The study on the shear bond strength of resin and porcelain to Titanium (티타늄에 대한 레진과 도재의 결합 강도에 관한 연구)

  • Park, Ji-Man;Kim, Yeong-Soon;Jun, Sul-Gi;Park, Eun-Jin
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.47 no.1
    • /
    • pp.46-52
    • /
    • 2009
  • Statement of problem: Recently, titanium has become popular as superstructure material in implant dentistry because titanium superstructure can be easily milled by means of computer-aided design and manufacture (CAD/CAM) technique. But retention form such as nail head or bead cannot be cut as a result of technical limitation of CAD/CAM milling and bond strength between titanium and porcelain is not as strong as that of conventional gold or metal alloy. Purpose: The objective of this study was to evaluate the shear bond strength of three different materials: heat curing resin, composite resin, porcelain which were bonded to grade II commercially pure Titanium (CP-Ti). Material and methods: Thirty seven CP-Ti discs with 9 mm diameter, 10 mm height were divided into three groups and were bonded with heat curing resin (Lucitone 199), indirect composite resin (Sinfony), and porcelain (Triceram) which were mounted in a former with 7 mm diameter and 1 mm height. Samples were thermocycled for 1000 cycles at between $5-55^{\circ}C$. Shear bond strength (MPa) was measured with Instron Universal Testing Machine with cross head speed of 1 mm/min. The failure pattern was observed at the fractured surface and divided into adhesive, cohesive, and combination failure. The data were analyzed by one-way ANOVA and Scheffe's multiple range test (${\alpha}=0.05$). Results: Lucitone 199 ($17.82{\pm}5.13\;MPa$) showed the highest shear bond strength, followed by Triceram ($12.97{\pm}2.11\;MPa$), and Sinfony ($6.00{\pm}1.31\;MPa$). Most of the failure patterns in Lucitone 199 and Sinfony group were adhesive failure, whereas those in Triceram group were combination failure. Conclusion: Heat curing resin formed the strongest bond to titanium which is used as a CAD/CAM milling block. But the bond strength is still low compared with the bond utilizing mechanical interlocking and there are many adhesive failures which suggest that more studies to enhance bond strength are needed.

The effect of silane treatment timing and saliva contamination on shear bond strength of resin cement to porcelain (Silane의 처리시기와 타액오염이 도재-레진 시멘트의 전단 결합강도에 미치는 영향)

  • Ro, Young-Seon;Ryu, Jae-Jun;Suh, Kyu-Won
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.47 no.1
    • /
    • pp.61-69
    • /
    • 2009
  • Statement of problem: Porcelain veneers have become a popular treatment modality for aesthetic anterior prosthesis. Fitting porcelain veneers in the mouth usually involve a try-in appointment, which frequently results in salivary contamination of fitting surfaces. Purpose: An in vitro study was carried out to investigate the effect of silane treatment timing and saliva contamination on the resin bond strength to porcelain veneer surface. Material and methods: Cylindrical test specimens (n=360) and rectangular test specimens (n=5) were prepared for shear bond test and contact angle analysis. Whole cylindrical specimens divided into 20 groups, each of which received a different surface treatment and/or storage condition. The composite resin cement stubs were light-polymerized onto porcelain adherends. The shear bond strengths of cemented stubs were measured after dry storage and thermocycling (3,000 cycles) between 5 and $55^{\circ}C$. The silane and their reactions were chemically monitored by using Fourier Transform Infrared Spectroscopy analysis (FTIR) and contact angle analysis. One-way analysis of variance (ANOVA) and Dunnett's multiple comparison were used to analyze the data. Results: FT-IR analysis showed that salivary contamination and silane treatment timing did not affect the surface interactions of silane. Observed water contact angles were lower on the saliva contaminated porcelain surface and the addition of 37% phosphoric acid for 20 seconds on saliva contaminated porcelain increased the degree of contact angle. Silane applied to the porcelain, a few days before cementation, resulted in increasing the bond strength after thermocycling. Conclusion: Within the limitation of this study, it can be concluded that it would be better to protect porcelain prosthesis before saliva contamination with silane treatment and to clean the contaminated surface by use of phosphoric acid.

Effect of titanium surface microgrooves and thermal oxidation on in vitro osteoblast responses (마이크로그루브 및 열산화 복합 티타늄 표면의 골아세포분화 증진효과)

  • Seo, Jin-Ho;Lee, Richard sungbok;Ahn, Su-Jin;Park, Su-Jung;Lee, Myung-Hyun;Lee, Suk Won
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.53 no.3
    • /
    • pp.198-206
    • /
    • 2015
  • Purpose: We aimed to investigate the effect of combined various microgrooves and thermal oxidation on the titanium (Ti) and to evaluate various in vitro responses of human periodontal ligament cells (PLCs). Materials and methods: Grade II titanium disks were fabricated. Microgrooves were applied on titanium discs to have $0/0{{\mu}m}$, $15/3.5{{\mu}m}$, $30/10{{\mu}m}$, and $60/10{{\mu}m}$ of respective width/depth by photolithography. Thermal oxidation was performed on the microgrooves of Ti substrata for 3 h at $700^{\circ}C$ in air. The experiments were divided into 3 groups: control group (ST), thermal oxidation group (ST/TO), and combined microgrooves and thermal oxidation group (Gr15-TO, Gr30-TO, Gr60-TO). Surface characterization was performed by field-emission scanning microscopy. Cell adhesion, osteoblastic differentiation, and mineralization were analyzed using the bromodeoxyurdine (BrdU), Alkaline phosphatase (ALP) activity, and extracellular calcium deposition assays, respectively. Statistical analysis was performed using the oneway analysis of variance and Pearson's bivariate correlation analysis (SPSS Version 17.0). Results: In general, the combined microgrooves and thermal oxidation group (Gr15-TO, Gr30-TO, Gr60-TO) showed significantly higher levels compared with the control (ST) or thermal oxidation (ST-TO) groups in the BrdU expression, ALP activity, and extracellular calcium deposition. Gr60-TO group induced highest levels of cell adhesion and osteoblastic differentiation. Conclusion: Within the limitation of this study, we conclude that the Ti surface treatment using combined microgrooves and thermal oxidation is highly effective in inducing the cell adhesion andosteoblastic differentiation. The propose surface is also expected to be effective in inducing rapid and strong osseointegration of Ti oral implants.

The Development of the Sustainability Appraisal Indicators for Clean Development Mechanism(CDM) Projects by Multi-Criteria Analysis(MCA) (청정개발체제(CDM)사업의 지속가능성평가 지표 개발 -다 기준분석법(MCA)을 활용하여-)

  • Yang, Chun-Seung;Park, Sung-Hwan;Park, Jung-Gu
    • Journal of Environmental Policy
    • /
    • v.8 no.2
    • /
    • pp.83-118
    • /
    • 2009
  • Clean Development Mechanism(CDM) projects under the Kyoto Protocol have two objectives. One is to assist the Parties included in Annex I in achieving compliance with their quantified emission limitation and reduction commitments in cost-effective ways by allowing them to implement emission reduction projects in Non-Annex I countries and receive CERs, which will offset their reduction commitments. The other is to assist Parties not included in Annex I in achieving sustainable development and technology transfers through investments by Annex I countries. However, in reality, it is said that the former objective is achievable but the latter is not. In this light, this article suggests sustainability appraisal criteria applicable for Korea. Among various methodologies, we used the 'multi-attributes utility theory(MAUT)'; one of the 'multi-criteria analysis (MCA)' methodologies judged to be the most practical and relevant. Based on the guidelines of the MAUT methodology, we identified sustainability criteria that meet the guidelines. We took two tracks, the first to find the preferences of Korean experts, and the other to check foreign cases. In all, 37 preliminary criteria were suggested to Korean experts and each criterion was scored, from between 1 and 3, in terms of relevance, possibility of real improvement, easiness of data collection, and preferences. We combined foreign cases and the results of a survey conducted in Korea and selected 12 core criteria and 10 additional criteria. After that, all the criteria were converted into indicators. The indicators were applied to a CDM project for case study. We chose the "Sihwa Tidal Power Project", which is currently the biggest tidal power plant in the world. Twelve core indicators and 3 additional indicators were applied. In order to weight each indicator, the 'analytical hierarchy process (AHP)' was used. A total of 30 experts were asked to suggest weights and 21 answered. Among them, only 14 respondents were proven to meet the consistency ratio. We analyzed the 14 responses through Expert Choice and the CDM project was scored (+)53.082. In addition, sensitivity analysis was undertaken with the result of (+)44.667 to (+)65.522. As a result of this study, it was proven that this project would contribute to the sustainable development of Korea.

  • PDF

Correlation of Exercise-Induced Bronchoconstriction to $PC_{20}$ and Maximal Airway Narrowing on the Dose-Response Curve to Methacholine (운동유발성 기관지수축의 정도와 Methacholine 유발시험의 민감도 및 최대기도협착과의 관련성)

  • Lim, Hyung-Suk;Yoon, Kyung-Ae;Koh, Young-Yull
    • Tuberculosis and Respiratory Diseases
    • /
    • v.42 no.2
    • /
    • pp.165-174
    • /
    • 1995
  • Background: Exercise is one of the most common precipitants of acute asthma encountered in clinical practice. The development of airflow limitation that occurs several minutes after vigorous exercise, i. g. exercise-induced bronchoconstriction(EIB), has been shown to be closely correlated with the nonspecific bronchial hyperresponsiveness, which is the hallmark of bronchial asthma. All previous reports that assessed the correlation of EIB to nonspecific bronchial hyperresponsiveness have focused on airway sensitivity($PC_{20}$) to inhaled bronchoconstrictor such as methacholine or histamine. However, maximal airway narrowing(MAN), reflecting the extent to which the airways can narrow, when being exposed to high dose of inhaled stimuli, has not been studied in relation to the degree of EIB. Methods: Fifty-six children with mild asthma(41 boys and 15 girls), aged 6 to 15 years(mean${\pm}$SD, $9.9{\pm}2.5$ years) completed this study. Subjects attended the laboratory on two consecutive days. Each subject performed the high-dose methacholine inhalation test at 4 p.m. on the first day. The dose-response curves were characterized by their position($PC_{20}$) and MAN, which was defined as maximal response plateau(MRP: when two or three data points of the highest concentrations fell within a 5% response range) or the last of the data points(when a plateau could not be measured). On the next day, exercise challenge, free running outdoors for ten minutes, was performed at 9 a.m.. $FEV_1$ was measured at graduated intervals, 3 to 10 minutes apart, until 60 minutes after exercise. Response(the maximal ${\triangle}FEV_1$ from the pre-exercise value) was classified arbitrarily into three groups; no response((-) EIB: ${\triangle}FEV_1$<10%), equivocal response ($({\pm})$EIB:10%<${\triangle}FEV_1$<20%) and definite response($({\pm})$EIB:${\triangle}FEV_1$>20%). Results: 1) When geometric mean $PC_{20}$ of the three groups were compared, $PC_{20}$ of (+) EIB group was significantly lower than that of (-)EIB group. 2) There was a close correlation between $PC_{20}$ and the severity of EIB in the whole group(r=-0.568, p<0.01). 3) Of the total 56 subjects, MRP could be measured in 36 subjects, and the MRP of these subjects correlated fairly with the severity of EIB(r=0.355, p<0.05) 4) The MAN of (+) EIB group was significantly higher than that of (-)EIB group(p<0.01). 5) The MAN correlated well with the severity of EIB in the whole group(r=0.546, p<0.01). Conclusion: The degree of MAN as well as bronchial sensitivity($PC_{20}$) to methacholine is correlated well with the severity of EIB. The results suggest that the two main components of airway hyperresponsiveness may be equally important determinants of exercise reactivity, although the mechanism may be different from each other. The present study also provides further evidence that EIB is a manifestation of the increased airway reactivity characteristic of bronchial asthma.

  • PDF

Effect of Immune System on Retrovirus-Mediated Herpes Simplex Virus Thymidine Kinase Gene Therapy (면역체계가 Retroviral Vector로 이입한 Herpes Simplex Virus Thymidine Kinase 유전자치료에 미치는 영향)

  • Park, Jae-Yong;Joo, So-Young;Chang, Hee-Jin;Son, Ji-Woong;Kim, Kwan-Young;Kim, Keong-Seok;Kim, Chang-Ho;Park, Jae-Ho;Lee, Jong-Ki;Jung, Tae-Hoon
    • Tuberculosis and Respiratory Diseases
    • /
    • v.46 no.2
    • /
    • pp.229-240
    • /
    • 1999
  • Background: The impact of the immune response on cancer gene therapy using viral vectors to deliver a "suicide gene" is currently unclear. A vigrous immune response targeted at viral proteins or transgene may enhance the efficacy of tumor destruction and even augment responses to tumor antigens. These responses may involve the release of cytokines and stimulation of tumor specific cytotoxic T-lymphocytes that enhance therapeutic efficacy. On the other hand, a vigorous rapid cellular immune response may destroy cells expressing the therapeutic gene and attenuate the response to therapy. Furthermore, development of neutralizing antibody responses may prevent readministration of virus, a potentially significant limitation. Evaluating the significance of these limitations in animal models and developing solutions are therefore of obvious importance. Methods: After retroviral transduction of mouse mesothelioma cell line(AB12) with Herpes Simplex Virus thymidine kinase (HSVtk) gene in vitro, subcutaneous flank tumors were established. To study the effect of intact immune system on efficacy of tumor erradication, the ability of the HSVtk/ganciclovir system to inhibit tumor growth was compared among normal Balb/c mice, immunodeficient Balb/c-nude and SCID mice, and Balb/c mice immunosuppressed with cyclosporin. Results: Ganciclovir treatment resulted in greater inhibition of tumor growth in Balb/c mice compared with immunodeficient Balb/c-nude mice and SCID mice(in immunodeficient mice, there were no growth inhibition by ganciclovir treatment). Ganciclovir treatment resulted in greater inhibition of tumor growth in noncyclosporin (CSA) treated Balb/c mice compared with CSA treated Balb/c mice. On day 8, mean ganciclovir-treated tumor volume were 65% of control tumor volume in Balb/c mice versus 77% control tumor volume in CSA-treated Balb/c mice. This effect was still evident during therapy (day 11 and 13). On day 13, non-CSA treated tumor volume was 35% of control tumor volume versus 60% of control tumor volume in CSA treated Balb/c mice. Duration of expression of HSVtk was not affected by the immunosuppression with CSA. Conclusion: These results indicate that the immune responses against retrovirally transduced cells enhance the efficacy of the HSVtk/ganciclovir system. These findings have important implications for clinical trials using currently available retrovirus vectors as well as for future vector design.

  • PDF

The Usefulness of Serologic Diagnosis for Tuberculosis with Two Rapid Immunochromatographic Assay Devices (혈청학적 방법을 이용한 결핵 진단 방법의 효용성)

  • Kim, Deog-Kyeom;Kwon, Sung-Youn;Lee, Suk-Young;Park, Gye-Young;Jung, Kyung-Hae;Lee, Chun-Taek;Yoo, Churl-Gyoo;Kim, Young-Whan;Han, Sung-Koo;Shim, Yong-Soo
    • Tuberculosis and Respiratory Diseases
    • /
    • v.47 no.5
    • /
    • pp.586-597
    • /
    • 1999
  • Background: Many diagnostic tests have developed to diagnose tuberculosis and other mycobacterial diseases but the diagnosis of tuberculosis relies largely on radiological findings and acid-fast staining of sputum and/or culture. Recently, new serologic diagnostic methods, which are safe and easy to use have been introduced into Korea. In this study, the usefulness of serologic diagnosis for tuberculosis and the disease pattern induced variation of the test were evaluated. Methods: Serological assay was performed upon 108 patients with two test kits, the ICT tuberculosis and the BioSign$^{TM}$TB, which are based upon a rapid immunochromatographic assay technique, capable of being interpreted within 15 minutes. The case groups consisted of 61 patients with active pulmonary tuberculosis(36 patients), extrapulmonary tuberculosis(3 patients), or both(22 patients). Control groups consisted of 47 patients with inactive old pulmonary tuberculosis(17 patients), nontuberculous pulmonary disease(16 patients) and nonpulmonary cardiac disease(14 patients). Results : The diagnostic sensitivity, specificity, positive predictive value(PPV) and negative predictive value(NPV) of the ICT tuberculosis were 64.3%, 91.5%, 90.0% and 68.3% respectively. The diagnostic sensitivity, specificity, PPV and NPV of the BioSign$^{TM}$TB were 76.5%, 95.3%, 94.1 % and 78.8% respectively. Differences in sensitivity were not significant between patients with previous history of tuberculosis or patients without prior history of tuberculosis. The ICT tuberculosis test showed higher sensitivity in pulmonary tuberculosis patients(76.5%) than extrapulmonary tuberculosis patients(33.3%). There was no difference in sensitivity between patients with or without cavitary lesion by chest X-ray. Conclusion: Considering high specificity and PPV, serologic diagnosis using a rapid immunochromatographic assay device is another helpful diagnostic method in the diagnosis of tuberculosis, when combined with previous diagnostic methods such as chest X-ray, microbiologic study but it has limitation in terms of confirming the diagnosis for tuberculosis as the only diagnostic method because of relatively low sensitivity and NPV.

  • PDF