• Title/Summary/Keyword: Limit Resolution

Search Result 280, Processing Time 0.027 seconds

Optimization of Ascorbic Acid Extraction from Rugosa Rose (Rosa rugosa Thunb.) Fruit Using Response Surface Methodology and Validation of the Analytical Method

  • UM, Min;KIM, Ji-Woo;LEE, Jae-Won
    • Journal of the Korean Wood Science and Technology
    • /
    • v.48 no.3
    • /
    • pp.364-375
    • /
    • 2020
  • In this study, ultrasound-assisted extraction was performed to extract ascorbic acid from rugosa rose (Rosa rugosa Thunb.) fruit. The optimal conditions were investigated by response surface methodology, using two variable including reaction time (16-44 min) and temperature (16-44℃). The ascorbic acid extraction was sensitive to the reaction time rather than the reaction temperature, and the optimal conditions for ascorbic acid extraction were 25℃ and 30 min. Ascorbic acid and gallic acid in the rugosa rose fruit extract were completely separated by HPLC, with a resolution factor of over 1.5 between the two. The correlation coefficient of the ascorbic acid was 0.999 in a linearity test for 50-150 ㎍/mL concentration of extract. The limit of detection and limit of quantification values were 0.16 ㎍/mL and 29.89 ㎍/mL, respectively. The relative standard deviations (RSD) for repeatability and reproducibility were determined, and each RSD showed good precision at less than 5% (N=6).

Bearing fault detection through multiscale wavelet scalogram-based SPC

  • Jung, Uk;Koh, Bong-Hwan
    • Smart Structures and Systems
    • /
    • v.14 no.3
    • /
    • pp.377-395
    • /
    • 2014
  • Vibration-based fault detection and condition monitoring of rotating machinery, using statistical process control (SPC) combined with statistical pattern recognition methodology, has been widely investigated by many researchers. In particular, the discrete wavelet transform (DWT) is considered as a powerful tool for feature extraction in detecting fault on rotating machinery. Although DWT significantly reduces the dimensionality of the data, the number of retained wavelet features can still be significantly large. Then, the use of standard multivariate SPC techniques is not advised, because the sample covariance matrix is likely to be singular, so that the common multivariate statistics cannot be calculated. Even though many feature-based SPC methods have been introduced to tackle this deficiency, most methods require a parametric distributional assumption that restricts their feasibility to specific problems of process control, and thus limit their application. This study proposes a nonparametric multivariate control chart method, based on multiscale wavelet scalogram (MWS) features, that overcomes the limitation posed by the parametric assumption in existing SPC methods. The presented approach takes advantage of multi-resolution analysis using DWT, and obtains MWS features with significantly low dimensionality. We calculate Hotelling's $T^2$-type monitoring statistic using MWS, which has enough damage-discrimination ability. A bootstrap approach is used to determine the upper control limit of the monitoring statistic, without any distributional assumption. Numerical simulations demonstrate the performance of the proposed control charting method, under various damage-level scenarios for a bearing system.

Finite element analysis of viscoelastic flows in a domain with geometric singularities

  • Yoon, Sung-Ho;Kwon, Young-Don
    • Korea-Australia Rheology Journal
    • /
    • v.17 no.3
    • /
    • pp.99-110
    • /
    • 2005
  • This work presents results of finite element analysis of isothermal incompressible creeping viscoelastic flows with the tensor-logarithmic formulation of the Leonov model especially for the planar geometry with singular comers in the domain. In the case of 4:1 contraction flow, for all 5 meshes we have obtained solutions over the Deborah number of 100, even though there exists slight decrease of convergence limit as the mesh becomes finer. From this analysis, singular behavior of the comer vortex has been clearly seen and proper interpolation of variables in terms of the logarithmic transformation is demonstrated. Solutions of 4:1:4 contraction/expansion flow are also presented, where there exists 2 singular comers. 5 different types spatial resolutions are also employed, in which convergent solutions are obtained over the Deborah number of 10. Although the convergence limit is rather low in comparison with the result of the contraction flow, the results presented herein seem to be the only numerical outcome available for this flow type. As the flow rate increases, the upstream vortex increases, but the downstream vortex decreases in their size. In addition, peculiar deflection of the streamlines near the exit comer has been found. When the spatial resolution is fine enough and the Deborah number is high, small lip vortex just before the exit comer has been observed. It seems to occur due to abrupt expansion of the elastic liquid through the constriction exit that accompanies sudden relaxation of elastic deformation.

Nano Scale Compositional Analysis by Atom Probe Tomography: I. Fundamental Principles and Instruments (Atom Probe Tomography를 이용한 나노 스케일의 조성분석: I. 이론과 설비)

  • Jung, Woo-Young;Bang, Chan-Woo;Gu, Gil-Ho;Park, Chan-Gyung
    • Applied Microscopy
    • /
    • v.41 no.2
    • /
    • pp.81-88
    • /
    • 2011
  • Even though importance of nano-scale structure and compositional analysis have been getting increased, existing analysis tools have been reached to their limitations. Recent development of Atom Probe Tomography (APT), providing 3-dimensional elemental distribution and compositional information with sub-nm scale special resolution and tens of ppm detection limit, is one of key technique which can overcome these limitations. However, due to the fact that APT is not well known yet in the domestic research area, it has been rarely utilized so far. Therefore, in this article, the theoretical background of APT was briefly introduced with sample preparation to help understanding APT analysis.

An Analysis of the Limit Cycle Oscillation in Digital PID Controlled DC-DC Converters

  • Chang, Changyuan;Hong, Chao;Zhao, Xin;Wu, Cheng'en
    • Journal of Power Electronics
    • /
    • v.17 no.3
    • /
    • pp.686-694
    • /
    • 2017
  • Due to the wide use of electronic products, digitally controlled DC-DC converters are attracting more and more attention in recent years. However, digital control strategies may introduce undesirable Limit Cycle Oscillation (LCO) due to quantization effects in the Analog-to-Digital Converter (ADC) and Digital Pulse Width Modulator (DPWM). This results in decreases in the quality of the output voltage and the efficiency of the system. Meanwhile, even if the resolution of the DPWM is finer than that of the ADC, LCO may still exist due to improper parameters of the digital compensator. In order to discover how LCO is generated, the state space averaging model is applied to derive equilibrium equations of a digital PID controlled DC-DC converter in this paper. Furthermore, the influences of the parameters of the digital PID compensator, and the resolutions of the ADC and DPWM on LCO are studied in detail. The amplitude together with the period of LCO as well as the corresponding PID parameters are obtained. Finally, MATLAB/Simulink simulations and FPGA verifications are carried out and no-LCO conditions are obtained.

Determination of L-Carnitine in Infant Powdered Milk Samples after Derivatization

  • Park, Jung Min;Koh, Jong Ho;Kim, Jin Man
    • Food Science of Animal Resources
    • /
    • v.41 no.4
    • /
    • pp.731-738
    • /
    • 2021
  • Herein, a novel analytical method using a high-performance liquid chromatography-fluorescence detector (HPLC/FLD) is developed for rapidly measuring an L-carnitine ester derivative in infant powdered milk. In this study, solid-phase extraction cartridges filled with derivatized methanol and distilled water were used to effectively separate L-carnitine. Protein precipitation pretreatment was carried out to remove the protein and recover the analyte extract with a high recovery (97.16%-106.56%), following which carnitine in the formula was derivatized to its ester form. Precolumn derivation with 1-aminoanthracene (1AA) was carried out in a phosphate buffer using 1-(3-dimethylaminopropyl)-3-ethylcarbodiimide hydrochloride (EDC) as the catalyst. Method validation was performed following the AOAC guidelines. The calibration curves were linear in the L-carnitine concentration range of 0.1-2.5 mg/L. The lower limit of quantitation and limit of detection of L-carnitine were 0.076 and 0.024 mg/L, respectively. The intra- and interday precision and recovery results were within the allowable limits. The results showed that our method helped reduce the sample preparation time. It also afforded higher resolution and better reproducibility than those obtained by traditional methods. Our method is suitable for detecting the quantity of L-carnitine in infant powdered milk containing a large amount of protein or starch.

Simultaneous Analysis of Cold Medicine Component by High-Performance Liquid Chromatography(HPLC) (고성능 액체크로마토그래피(HPLC)를 이용한 Cold Medicine 성분의 동시 분석)

  • Wonju Lee;Seung-Tae Choi;Keun-Sik Shin;Jin-Young Park;Jae-Ho Sim
    • The Journal of the Convergence on Culture Technology
    • /
    • v.9 no.6
    • /
    • pp.867-873
    • /
    • 2023
  • In this study, for the purpose of standardized quality control of a cold medicine, we simultaneous analyzed four main chemical components of a cold medicine: acetaminophen, caffeine, methyl paraben, and propyl paraben. The sample was subjected to quantitative analysis using high performance liquid chromatography (HPLC), after pretreatment of four components. The experiment was carried out by using Isocratic elution at wavelength of 270nm. Acetonitrile and water (H2O) were used as a mobile phase at a flow rate of 1.0mL/min in a commercial C18 reversed-phase column. A volume of 10uL cold medicine were injected into the column with column oven temperature at 35℃. As a result of the experiment, the values of Resolution were 4.983, 1.596, 5.519, and 1.678 respectively-well over Rs >1.5, which indicates that the separation of four components were efficient. In addition, value of symmetry factor of the components was 1.056, 1.069, 1.032, and 1.133 respectively, to show its symmetrical stability. The calibration curve of all four components exhibits good linearity with R2 >0.9995 to 0.9999. Furthermore, the limit of detection(LOD) were between 0.0118 to 1.5973 mg/mL, while the limit of quantification (LOQ) were between 0.0353 to 4.7919 ㎍/mL with the recovery rate of 79.6% ~ 120.5%. The results of this study showed an efficient quality evaluation of a simultaneous analysis method for cold medicine components.

The Design and Performance Test of Tracking Actuator for NFR system (근접장 기록 장치를 위한 트랙킹 구동기의 설계 및 실험)

  • Kim, Gi-Hyeon;Lee, Mun-Gu;Gwon, Dae-Gap
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.18 no.8
    • /
    • pp.174-181
    • /
    • 2001
  • Nowadays, the improvement and development of Multi-media and information & communication technology is rapidly processed. They need large data storage capacity. So that, many studies and researches in data storage have been carried out. According to them, the data storage capacity has been increased. But the limitation of storage capacity is happened for several problems. One of them is spot & pit size in optical and magnetic data storage and another is the resolution of actuators. The problems in spot & pit size are covered by new data storage methods-- for examples, AFM(Atomic Force Microscopy), MO(Magneto-optical) system, and NFR(Near-Field decoding) system etc. But the resolution limit of an actuator was not developed and doesn\`t follow up the development of spot & pit size. Because of them, we should improve a resolution of an actuator. Especially, in this paper an actuator if studied and designed for NFR (in using SIL(Solid Immersion Lens) system. It is a dual stage actuator, which consists of a Fine actuator and a Coarse actuator. and should desire 100nm accuracy. Its actuating force generation method is VCM(Voice Coil Motor). The Fine actuator is composed of 4-leaf springs and a bobbin wrapped by coil. The Coarse actuator has Coils and 3-Roller bearings. Also, The Characteristics of designed actuator for NFR system is estimated by Sine-Swept mode and LDV(Laser Doppler Vibro-meter).

  • PDF

Super-RENS Readout Signal Simulation (Super-RENS 재생 신호 계산)

  • Lee, Jin-Kyung;Hwang, In-Oh;Kim, Hyun-Ki;Bae, Jae-Cheol;Kim, Joo-Ho
    • Transactions of the Society of Information Storage Systems
    • /
    • v.3 no.1
    • /
    • pp.34-39
    • /
    • 2007
  • Super-REsolution Near-field Structure (Super-RENS) 재생 현상을 모델링하고 재생 신호를 계산하여 실험 결과와 비교하였다. 약 2mW 내외의 높은 광 파워로 집광된 Spot 은 디스크 내의 상변화 물질인 GST 를 용융시키므로 집광 Spot 내에는 용융 영역과 비 용융 영역이 공존하게 되고 연속적 또는 불연속적인 경계를 이루게 된다. 이러한 열 효과로부터 기인하는 집광 Spot 내에서의 물질의 광학적 특성 변화와 변화 정도의 차이를 가정하였고 변화된 광학적 특성은 집광된 Spot 의 유효 크기를 줄어들게 함으로써 회절한계 이하의 정보를 재생 가능하게 한다. 계산은 FDTD 방법과 Scalar 방법을 병행하였다. FDTD 방법으로는 위와 같은 집광 Spot 내의 물질 굴절률 (n,k) 변화로부터 회절한계 이하의 정보가 재생 가능함과 CNR 문턱 현상을 확인하였고, Scalar 방법으로는 물질 굴절률을 직접 다루지 않고 굴절률 변화로부터 기인하는 광의 Amplitude 와 Phase 변화로부터 회절한계 이하의 정보가 재생 가능함을 확인하였다. 이 때 광의 Amplitude 와 Phase 변화를 모델링하기 위하여 지름, 위치, 반사율 변화량, 위상 변화량의 네가지 변수로 정의되는 광 마스크를 도입하였다. Scalar 방법을 이용하여 재생 RF 신호 등 다양한 Super-RENS 디스크의 신호를 계산 활용 할 수 있고 다음의 두가지 광학계에 대하여 계산과 실험으로 얻은 채널 특성 및 RF 신호를 비교하여 각각 오차평균 4.2%, 4.7%로 일치함을 확인하였다. 파장 659nm, NA=0.6, Min Pit Length=173nm ROM 디스크 System, 파장 405nm, NA=0.85 Min Mark Length=75nm WORM 디스크 System.

  • PDF

Gaussian apodization and superresolution optical imaging system for soft X-ray region (Gaussian Apodization이 되어 있는 X-선 결상계의 초분해능)

  • 송영란;이민희;이상수
    • Korean Journal of Optics and Photonics
    • /
    • v.7 no.2
    • /
    • pp.89-95
    • /
    • 1996
  • Superresolution optics, employing Gaussian apodization, is rigorously treated at the soft X-ray wave-length(λ=0.013 ${\mu}{\textrm}{m}$) region. In the diffraction integral, the line integral along the imaginary axis is found small, and it is ignored, so that the diffraction integral consists of the integration along the real axis. The resolution of the diffracted image is not effected by the pupil angular frequency bandwidth $2{\omega}_0$, which is one of the most important the characteristic features of Gaussian apodization ($e^{-o^2x^2}$ optics. The superresolution optics has resolution ($\frac{1}{2}{\times}FWHM)$=$\Delta$x=0.008 $\mu$m which is smaller than the Rayleigh criterion of 2λ=0.026 ${\mu}{\textrm}{m}$ for NA=0.25. The optical system has ${\omega}_0{\ge}\frac{1}{2}{\sigma}$, which gives the peak intensity of the diffracted image larger than $e^{-2}$ times intensity obtainable by the infinite sperture.

  • PDF