• Title/Summary/Keyword: Lim Gyu

Search Result 1,212, Processing Time 0.029 seconds

Adequacy of Source to Image Receptor Distance with Chest Postero-Anterior Projection in Digital Radiology System (디지털방사선 환경에서 흉부 후-전 방향 검사 시 초점과 영상수용체간 거리의 적절성)

  • Joo, Young-Cheol;Lim, Cheong-Hwan;You, In-Gyu;Jung, Hong-Ryang;Lee, Sang-Ho
    • Journal of radiological science and technology
    • /
    • v.39 no.2
    • /
    • pp.135-142
    • /
    • 2016
  • The purpose of this study is to evaluate propriety of using SID 180cm at Chest PA examination and to find effect of geometrical cause to the image. XGEO-GC80, INNOVISION-SH, CXDI-40EG detector and a chest phantom designed self-production was used for this study. Images were acquired at SID 180cm with changing the factor OID as 0, 75 and 83mm and were analyzed by Centricity Radiography RA1000 PACS system. Statistical program was used the SPSS (Version 22.0, SPSS, Chicago, IL, USA), p-value(under 0.05) was considered to be statistically significant. In OID 0 mm was enlarged about 2.7~3.5 mm than the actual degree of the HS, BS of phantom in all equipments. Compared with the calculated magnification has been expanded 1.6~2.8% when viewed. The OID 75 mm with OID 83 mm was extended from the CS and BS 6~8 mm range. Compared to the calculated values, the measured values are expanded from 6.1 to 7.9%. CS and BS according to the OID change showed a statistically significant difference (p<0.05) among each group, the post-analysis only OID 0 mm group appeared as an independent group, 75 mm and 83 mm are separated in the same group It was. But had no statistically significant difference could change depending on the OID (p>0.05), post-mortem analysis showed, both in the same group. Heart sizes appears larger than actual size 6~8 mm at chest PA examination which is enlarged 6.1~7.9% more than the actual theoretical value. We can find magnification of the image because of the increase of the OID due to technical limitations between cover of standing detector and the image plate. so we suggest to have occurred between them when considering the need to adjust the equipment installed by the SID to match the characteristics of the equipment.

Growth Characteristics and Nutrient Contents under Dominant Submerged Plants in Flood Control Reservoir around Dongbok Lake (동복호 저수구역내 주요 침수 분포종별 생육 및 영양염류 함량)

  • Seo, Young-Jin;Lee, Jun-Bae;Seo, Dong-Cheol;Kang, Se-Won;Lee, Sang-Gyu;Choi, Ik-Won;Lim, Byung-Jin;Kim, Sang-Don;Heo, Jong-Soo;Cho, Ju-Sik
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.45 no.5
    • /
    • pp.836-841
    • /
    • 2012
  • Distributions and growth of submerged plants with water level were investigated in a flood control reservoir around Dongbok Lake. In adddition, the total amount of biomass and uptakes of plants per unit area ($m^2$) in the flood control reservoir were investigated. The total vegetation area was $156,871m^2$ in the Dongbok flood control reservoir ($209,160m^2$) before flooding. By July 11, the Dongbok flood control reservoir was flooded during rainy season except for upper area. Dominant plants were CRXDM (Carex dimorpholepis Steud), ECHCF (Echinochloa crusgalli), POLHY (Polygonum hydropiper L) and BROTE (Bromus tectorum L) which occupied 75% of the flood control reservoir. The total amounts of organic matter uptakes per unit area ($m^2$) with distribution rates by CRXDM, ECHCF, POLHY and BROTE under different submerged plants were 65.5, 6.8, 7.0 and 13.0%, respectively. The total amount of nitrogen uptakes per unit area ($m^2$) with distribution rates at different submerged plants were in the order of CRXDM ($1.30g\;m^{-2}$) > POLHY ($0.34g\;m^{-2}$) > BROTE ($0.30g\;m^{-2}$) > ECHCF ($0.25g\;m^{-2}$). The total amounts of phosphorus uptakes per unit area ($m^2$) with distribution rates at different submerged plants were great in the order of CRXDM (51.8%) > BROTE (17.7%) > POLHY (10.3%) > ECHCF (9.6%). Thus, the results of this study suggest that O.M, T-N and T-P by submerged plants in Dongbok Lake were strongly influenced at water quality in flood control reservoir.

The seasonal appearance and chemical composition characteristics of cladode of Opuntia humifusa (천년초 줄기의 수확 시기 별 외관 및 성분 품질 특성)

  • Kim, Hee Jung;Kim, Mi-Hyun;Jang, Mi;Lim, Tae-Gyu;Hong, Hee-Do;Rhee, Young Kyoung;Kim, Kyung-Tack;Cho, Chang-Won
    • Food Science and Preservation
    • /
    • v.23 no.4
    • /
    • pp.502-509
    • /
    • 2016
  • The seasonal appearance and the chemical composition characteristics of cladode of Opuntia humifusa were investigated in this study. The minor (horizontal) and major (vertical) axes, the width, and weight of O. humifusa cladode were compared for its appearance features. Moisture, crude protein, ash, fat, color, dietary fiber, mineral, and amino acids contents were measured for the comparison of their chemical composition characteristics. The cladode of O. humifusa harvested in summer showed higher values of minor and major axis, width, and weight than those harvested in winter. According to the results of Hunter color index, cladode of O. humifusa harvested in summer showed the highest lightness level (Hunter L value). In the meanwhile, cladode of O. humifusa harvested in spring showed the highest Hunter a (redness) and b (yellowness) values. Cladode of O. humifusa harvested in summer had the lowest crude protein and crude fat contents, while it showed the highest crude ash content. The total contents of moisture and dietary fiber were significantly greater than summer-harvested cladode of O. humifusa followed by spring- and winter-harvested cladode of O. humifusa. The major mineral content of all seasonal cladode of O. humifusa was $Ca^{2+}$. Glutamic acid and aspartic acid were the major amino acids in all seasonal samples. Contrary, the contents of total amino acids and free amino acids were the lowest in summer-harvested cladode of O. humifusa. Taken together, it was concluded that the appearance and chemical quality of cladode of O. humifusa was versatile depending on the harvesting season.

26GHz 40nm CMOS Wideband Variable Gain Amplifier Design for Automotive Radar (차량용 레이더를 위한 26GHz 40nm CMOS 광대역 가변 이득 증폭기 설계)

  • Choi, Han-Woong;Choi, Sun-Kyu;Lee, Eun-Gyu;Lee, Jae-Eun;Lim, Jeong-Taek;Lee, Kyeong-Kyeok;Song, Jae-Hyeok;Kim, Sang-Hyo;Kim, Choul-Young
    • Journal of IKEEE
    • /
    • v.22 no.2
    • /
    • pp.408-412
    • /
    • 2018
  • In this paper, a 26GHz variable gain amplifier fabricated using a 40nm CMOS process is studied. In the case of an automobile radar using 79 GHz, it is advantageous in designing and driving to drive down to a low frequency band or to use a low frequency band before up conversion rather than designing and matching the entire circuit to 79 GHz in terms of frequency characteristics. In the case of a Phased Array System that uses time delay through TTD (True Time Delay) in practice, down conversion to a lower frequency is advantageous in realizing a real time delay and reducing errors. For a VGA (Variable Gain Amplifier) operating in the 26GHz frequency band that is 1/3 of the frequency of 79GHz, VDD : 1V, Bias 0.95V, S11 is designed to be <-9.8dB (Mea. High gain mode) and S22 < (Mea. high gain mode), Gain: 2.69dB (Mea. high gain mode), and P1dB: -15 dBm (Mea. high gain mode). In low gain mode, S11 is <-3.3dB (Mea. Low gain mode), S22 <-8.6dB (Mea. low gain mode), Gain: 0dB (Mea. low gain mode), P1dB: -21dBm (Mea. Low gain mode).

Selection of Insecticide Resistance Markers in Field-collected Populations of Myzus persicae (복숭아혹진딧물 야외개체군의 살충제 저항성 마커 선발)

  • Kim, Ju Il;Kwon, Min;Shim, Jae Dong;Kim, Jeom Soon;Lee, Yeong Gyu;Jee, Sam Nyu;Lee, Jeong Tae;Ryu, Jong Soo;Yoo, Dong Lim;Lee, Gye Jun
    • Korean journal of applied entomology
    • /
    • v.53 no.2
    • /
    • pp.149-156
    • /
    • 2014
  • The resistance levels of the green peach aphid, Myzus persicae (Sulzer), against 10 insecticides was checked and selected the applicable insecticide resistance markers. We conducted our study in 5 cabbage cultivation regions (Pyeongchang, Hongcheon, Bongwha, Muju, and Jeju) of Korea, over 3 successive years (2009-2011). We selected a multi-resistant (MR) strain from among the 5 field-collected populations. We analyzed esterase over-expression and mutation(s) in the target sites, by using native isoelectric focusing (IEF) and quantitative sequencing (QS). We detected esterase over-expression and StoF mutation in the acetylcholinesterase 1 gene (ace1) in all of the field-collected populations, including the MR strain. We did not detect the LtoF mutation, which is a well-known knockdown resistance (kdr) mutation in the para-type sodium channel gene (para), in the MR strain; however, the value of the MR strain for bifenthrin was 3,461-fold higher than that of the susceptible strain. Our results indicate that insecticide resistance is more effectively evaluated using molecular markers than by conducting a bioassay. The molecular markers StoF in ace1 and MtoL in para can easily be applied in diagnostic methods such as QS or PCR amplification of specific alleles (PASA). These methods may be extended to management of M. persicae resistance in the field.

The Clinical Usefulness of Spiral CT Angiography in the Diagnosis of Pulmonary Thromboembolism (폐색전증 진단에서 나선식 전산화 단층촬영 혈관조영술의 임상적 유용성)

  • Kim, Woo-Gyu;Lim, Byung-Sung;Kim, Mi-Young;Hwang, Hweung-Kon
    • Tuberculosis and Respiratory Diseases
    • /
    • v.47 no.5
    • /
    • pp.669-680
    • /
    • 1999
  • Background: Pulmonary thromboembolism(PTE) is a life threatening disease that needs early diagnosis. Spiral CT angiography depict thromboemboli in the central pulmonary vessels with greater than 90% sensitivity and specificity, which approaches the results of pulmonary angiography in the Prospective Investigation of Pulmonary Embolism Diagnosis(PIOPED) study. This study was performed to evaluate the findings and the diagnostic value(clinical utility) of the spiral CT angiography with 2D image(multiplanar reformation) and 3D images(Shaded surface display, Minimal intensity projection) in the pulmonary thromboembolism. Methods: We retrospectively analysed spiral CT angiography and pulmonary angiography, lung scan and clinical recordings of 20 patients who had PTE diagnosed by spiral CT angiography(n=19 cases) or pulmonary angiography(n=l case) from September 1997 to August 1998. Among 20 patients who had underwent spiral CT angiography, 14 patients could be performed lung perfusion scan at the same time. We analyzed the vascular and parenchymal change in spiral CT angiogram. Results: Anatomical distribution of PTE was as follows: 1) left lung(n= 103)

  • PDF

Effects of Apex Removal on the Growth and Yield of Artichoke by Planting Times (정식시기별 생장점 제거가 아티초크(Cynara scolymus L.)의 생육 및 수량에 미치는 영향)

  • Seong, Ki-Cheol;Kim, Chun Hwan;Son, Danial;Lim, Chan Gyu;Cheon, Sung Jong
    • Journal of Bio-Environment Control
    • /
    • v.23 no.1
    • /
    • pp.56-59
    • /
    • 2014
  • Apex removal is a common practice in artichoke cultivation to harvest heads of lateral shoots. This experiment was carried out to investigate the effect of apex removal by different planting times on the growth and yield of Artichoke (Cynara scolymus L.) in open field. Two treatments (apex removal and no apex removal) at three different planting times ($1^{st}$: Sep. 27, 2011, $2^{nd}$: March 29, 2012, and $3^{rd}$: Sep. 21, 2012) were tested using 'Green Globe' variety. There was no difference in the head characteristics and the number of harvested head between the treatments. The head weight was heavier in no apex removal of 242.7 g than the apex removal of 170.8 g. The yield also increased in no apex removal by 25% (1,249 kg/10a) compared to the apex removal of 997 kg/10a at the first planting time. At the second planting time, there was no difference in the head weights between the treatments. But the number of the harvested head was higher in no apex removal with 10.8 than 8.2 of the apex removal. The yield of no apex removal was 2,660 kg/10a, which was higher than 1,848 kg/10a of apex removal. At the third planting time, the head weight increased in no apex removal with 253.5 g compared to the apex removal with 218.7 g. The yield of no apex removal was 1,405 kg/10a, which was higher than 1,148 kg/10a of the apex removal. All the tests at 3 different planting times showed that the artichoke yields were higher in no apex removal than in apex removal. Therefore, it is desirable to cultivate artichoke without removing the apex for the higher yield and labor saving in open-field cultivation in Jeju island.

A Study on the Reduction of Kidney Uptake of 18F-FDG due to the Water Intake at the Time of Additional Examination in the PET/CT scan (PET/CT 검사에서 추가 검사 시 수분섭취에 따른 18F-FDG의 신장 섭취 감소에 대한 고찰)

  • Lee, Yi Lang;Kim, Sang Gyu;Ham, Jun Chul;Nam-Koong, Hyuk;Lim, Han Sang;Kim, Jae Sam
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.20 no.1
    • /
    • pp.47-51
    • /
    • 2016
  • Purpose By ingestion of 18F-FDG of kidney of PET/CT during the inspection, if additional examination is required, depending on whether you want to water intake, we want to confirm a change in the rate of decrease of F-18 FDG of the kidney. Materials and Methods The 80 patients without kidney disease were performed PET/CT examination. Device was analyzed after setting the kidney to a three-dimensional region of interest. In patients require additional examination, and inspection after 30 minutes, a PET/CT torso examination after the water of the 500 cc ingested at a time. After the addition of both water intake group and no hydration group of kidney of SUV, it was compared with PET/CT torso scan. Results High and low of the kidney SUV did not show a significant difference in the rate of decrease. Reduction rates of background (BKG) of additional examination was 2.8% and reduction rates of SUV was 49.7% (Hydration) : -6.8% (No hydration), so did show a significant difference. In the image blind test, the average point score of hydration and no hydration was 34.25 : 17.25. Conclusion An undercurrent of 18F-FDG in the kidney at the time of torso examination, it was confirmed that the reduction rate after the addition of water intake is high. It is considered that can be expected to improve the quality of an image due to a decrease in elongation through the kidneys examination with additional fluid intake as needed intake.

  • PDF

A Study for Perception of Hair Damage Using Friction Coefficient of Human Hair (모발의 마찰계수를 통한 모발 손상 인식 연구)

  • Lim, Byung Tack;Seo, Hong An;Song, Sang-Hun;Son, Seong Kil;Kang, Nae-Gyu
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.46 no.3
    • /
    • pp.295-305
    • /
    • 2020
  • Treatment for beauty using oxidizing agents damages hair with inducing structural alteration in cuticle layer, degradation of protein, and loss of lipid. This study connects a frictional coefficient upon the damaged hair by an instrumental test to the texture test by human being, and considered a moisture as a factor of the damage. A friction coefficient has been measured upon the hair with successive treatment of dye, perm, and bleach. The friction coefficient from the hair dye-treated three times was defined with 0.60, where 58% of answerer indicated an initial damage point as the hairs of iteration of dye-treatment increased. Even bleach treated three times results in 0.84 of friction coefficient corresponding to 88% of answerer attributed the hair to an initially damaged hair. In order to figure out a lipid loss in hair for human being to respond damage, a friction coefficient of the hair was controlled by removing 18-methyleicosanoic acid (18-MEA). The initial damage has been recognized by 0.60 of the friction coefficient for the 68% of answerer. Since moisture is the largest portion of the components in hair, moisture analysis has been performed to study a relationship between texture of damage and the friction coefficient from an instrumental evaluation. As an iteration of dye increases, the hair became hydrophilic with smaller contact angle. It is found that a damaged hair by dyeing possessed more than 0.42% of moisture compared to a healthy hair. Finally, it is elucidated that an increase of moisture in hair induced higher adhesive force corresponding to the friction coefficient, and the friction coefficient above 0.6 is attributed to the preception of hair damage.

Three dimensional GPR survey for the exploration of old remains at Buyeo area (부여지역 유적지 발굴을 위한 3차원 GPR 탐사)

  • Kim Jung-Bo;Son Jeong-Sul;Yi Myeong-Jong;Lim Seong-Keun;Cho Seong-Jun;Jeong Ji-Min;Park Sam-Gyu
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.49-69
    • /
    • 2004
  • One of the important roles of geophysical exploration in archeological survey may be to provide the subsurface information for effective and systematic excavations of historical remains. Ground Penetrating Radar (GPA) can give us images of shallow subsurface structure with high resolution and is regarded as a useful and important technology in archeological exploration. Since the buried cultural relics are the three-dimensional (3-D) objects in nature, the 3-D or areal survey is more desirable in archeological exploration. 3-D GPR survey based on the very dense data in principle, however, might need much higher cost and longer time of exploration than the other geophysical methods, thus it could have not been applied to the wide area exploration as one of routine procedures. Therefore, it is important to develop an effective way of 3-D GPR survey. In this study, we applied 3-D GPR method to investigate the possible historical remains of Baekje Kingdom at Gatap-Ri, Buyeo city, prior to the excavation. The principal purpose of the investigation was to provide the subsurface images of high resolution for the excavation of the surveyed area. Besides this, another purpose was to investigate the applicability and effectiveness of the continuous data acquisition system which was newly devised for the archeological investigation. The system consists of two sets of GPR antennas and the precise measurement device tracking the path of GPR antenna movement automatically and continuously Besides this hardware system, we adopted a concept of data acquisition that the data were acquired arbitrary not along the pre-established profile lines, because establishing the many profile lines itself would make the field work much longer, which results in the higher cost of field work. Owing to the newly devised system, we could acquire 3-D GPR data of an wide area over about $17,000 m^2$ as a result of the just two-days field work. Although the 3-D GPR data were gathered randomly not along the pre-established profile lines, we could have the 3-D images with high resolution showing many distinctive anomalies which could be interpreted as old agricultural lands, waterways, and artificial structures or remains. This case history led us to the conclusion that 3-D GPR method can be used easily not only to examine a small anomalous area but also to investigate the wider region of archeological interests. We expect that the 3-D GPR method will be applied as a one of standard exploration procedures to the exploration of historical remains in Korea in the near future.

  • PDF