• Title/Summary/Keyword: Lightning impulse test

Search Result 111, Processing Time 0.054 seconds

Acoustic Emission Monitoring of Lightning-Damaged CFRP Laminates during Compression-after-Impact Test

  • Shin, Jae-Ha;Kwon, Oh-Yang
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.32 no.3
    • /
    • pp.269-275
    • /
    • 2012
  • Carbon-fiber reinforced plastic(CFRP) laminates made of nano-particle-coated carbon fibers and damaged by a simulated lightning strike were tested under compression-after-impact(CAI) mode, during which the damage progress due to compressive loading has been monitored by acoustic emission(AE). The impact damage was induced not by mechanical loading but by a simulated lightning strike. Conductive nano-particles were coated directly on the fibers, from which CFRP coupons were made. The coupon were subjected to the strikes with a high voltage/current impulse of 10~40 kA within a few ${\mu}s$. The effects of nano-particle coating and the degree of damage induced by the simulated lightning strikes on AE activities were examined, and the relationship between the compressive residual strength and AE behavior has been evaluated in terms of AE event counts and the onset of AE activity with the compressive loading. The degree of impact damage was also measured in terms of damage area by using ultrasonic C-scan images. The assessment during the CAI tests of damaged CFRP showed that AE monitoring appeared to be useful to differentiate the degree of damage hence the mechanical integrity of composite structures damaged by lightning strikes.

Breakdown Characteristics of $SF_6/CF_4$ Mixtures Under AC and Standard Lightning Impulse Voltages in Uniform Field (평등전계에서 AC 및 표준 뇌 임펄스 전압의 $SF_6/CF_4$ 혼합 가스 절연 파괴 특성)

  • Sung, Heo-Gyung;Park, Shin-Woo;Hwang, Chung-Ho;Kim, Nam-Ryul;Huh, Chang-Su
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.06a
    • /
    • pp.227-228
    • /
    • 2007
  • Although many studies have been carried out about binary gas mixtures with $SF_6$, few studies were presented about breakdown characteristics of $SF_6/CF_4$ mixtures. At present study the breakdown characteristics of SFJCF4 mixtures in uniform field was performed. The experiments were carried out under AC and standard lightning impulse (SLI) voltages. The sphere-sphere electrode whose gap distance was 1 mm was used in a test chamber. $SF_6/CF_4$ mixtures contained from 0 to 100% $SF_6$ and the experimental gas pressure ranged from 0.1 to 0.4 MPa. The results show that addition of $SF_6$ to $CF_4$ increase AC and SLI breakdown voltages. Under AC voltages the breakdown voltages of each mixture were linearly increased according to the quantity of $SF_6$. However under SLI voltages the breakdown voltages of each mixture were similar.

  • PDF

Failure Prediction of Metal Oxide Varistor Using Nonlinear Surge Look-up Table Based on Experimental Data

  • Kim, Young Sun
    • Transactions on Electrical and Electronic Materials
    • /
    • v.16 no.6
    • /
    • pp.317-322
    • /
    • 2015
  • The metal oxide varistor (MOV) is a major component of the surge protection devices (SPDs) currently in use. The device is judged to be faulty when fatigue caused by the continuous inflow of lightning accumulates and reaches the damage limit. In many cases, induced lightning resulting from lightning strikes flows in to the device several times per second in succession. Therefore, the frequency or the rate at which the SPD is actually exposed to stress, called a surge, is outside the range of human perception. For this reason, the protective device should be replaced if it actually approaches the end of its life even though it is not faulty at present, currently no basis exists for making the judgment of remaining lifetime. Up to now, the life of an MOV has been predicted solely based on the number of inflow surges, irrespective of the magnitude of the surge current or the amount of energy that has flowed through the device. In this study, nonlinear data that shows the damage to an MOV depending on the count of surge and the amount of input current were collected through a high-voltage test. Then, a failure prediction algorithm was proposed by preparing a look-up table using the results of the test. The proposed method was experimentally verified using an impulse surge generator

A Study On the Impulse Response Behavior of Ground Rods in Power Distribution System (22.9kV-Y 다중접지 배전계통 접지극의 임펄스 응답 특성 실증연구)

  • Kang, Moon-Ho;Jang, Sang-Ok;Park, Sang-Man;Ha, Dong-Hyuk;Lee, Heung-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2003.07c
    • /
    • pp.1858-1860
    • /
    • 2003
  • Ground rods as the discharge path are commonly installed to ensure the safety of human beings and facilities from the surge. Accordingly, proper grounding resistance are specified by the grounding types, and the specified resistance are also required to install the lightning protective facilities. it is needed to analyze the difference between these two resistance through the field test. Therefore, in this paper, the impulse response behavior of the ground rods is analyzed by constructing the test facilities and by testing the ground rods in multi-ground power distribution systems. The impulse responses were analyzed, in transient state, by testing the concrete poles as well since the grounding wires are installed in the concrete poles.

  • PDF

Analysis of Lightning Current Distribution for Reducing the Conductive EMI in a Structure (도전성 EMI 저감을 위한 구조체의 뇌격전류 분류율 분석)

  • Cho, Sung-Chul;Lee, Tae-Hyung;Eom, Ju-Hong;Lee, Bok-Hee
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.1630-1631
    • /
    • 2011
  • Lightning current distribution in a building directly hit was studied by using a scaled steel frame structure model. As the test current source, impulse current with the rise time of 10 ${\mu}s$ and sinusoidal current with the frequency of 30 kHz were used to confirm the validity of test results. The current distributions at both horizontal and vertical pillars were measured by using CT. From the test results, the reduction effect for the conductive EMI was verified and a design method reducing the conductive EMI was proposed.

  • PDF

Development of Components and Installation Techniques of Air-termination System on the Metal Roof in Apartments (공동주택 금속기와지붕 수뢰시스템의 자재 및 시공기법 개발)

  • Lee, Ki-Hong
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.10
    • /
    • pp.109-115
    • /
    • 2011
  • Apartments covered with a metal roof made from galvalume steel are prevailing due to their economic and technical advantages. The metal roof, however, has disadvantages in terms of the installation of air-termination system on it because of the slip thickness of the metal roof. In this paper, the impacts of the lightning current to a metal roof were verified experimentally with a short lightning impulse current (10/350[${\mu}s$]). Also, we developed various supporters of air-termination conductor for the metal roof and verified their excellent workability and economical strength through field application test.

Effects of Length of Down Conductor on Transient Ground Impedance (인하도선 길이에 따른 과도접지임피던스 특성)

  • Lee, B.H.;Jeong, D.C.;Lee, S.B.;Lee, T.H.;Jung, H.U.;Lee, K.S.;Lee, S.C.
    • Proceedings of the KIEE Conference
    • /
    • 2005.07c
    • /
    • pp.2235-2237
    • /
    • 2005
  • This paper presents the transient impedance behaviors of grounding systems to lightning impulse current. The potential rise and effective impulse ground impedance of the test grounding electrodes were measured as a function of the rise time of impulse currents and lengths of down conductor. The transient ground impedances strongly depend on the configuration and size of grounding electrodes, the impulse current shapes and lengths of down conductor, and the inductance of reduce of grounding electrode inductance is an important factor to improve the transient ground impedance.

  • PDF

Dead Operation Characteristics of Earth Leakage Circuit Breaker Caused by Impulse Voltages (임펄스전압에 대한 누전차단기의 부동작 특성)

  • Lee, Bok-Hee;Chang, Sug-Hun;Lee, Seung-Chil
    • Proceedings of the KIEE Conference
    • /
    • 1997.07e
    • /
    • pp.1715-1717
    • /
    • 1997
  • This paper deals with the dead operation characteristics of the earth leakage circuit breaker(ELB) caused by impulse voltages. The surge protective devices for electronic circuit and AC power lines are becoming more widely used. It is possible to give rise to the malfunction of ELB due to the operation of surge protective devices, and the interruption of AC power lines brings about several disadvantages such as low reliability of electronic and informational systems, economical loss, and etc. The dead operation characteristics of the ELB from impulse voltages were measured under the conditions of KS C 4613 and the test circuit with a varistor. As a result, the peak current value of the zero-phase sequence circuit of the ELB is increased as the surge voltage and stray capacitance increase. All of the ELBs used in this work were satisfied with the lightning impulse dead operation test condition defined in KS C 4613. However one specimen only did not cause dead operation in the condition of the test circuit with a varistor. There is high possibility that a large portion of the ELBs connected with the AC power lines having the surge protective devices bring about the dead operation.

  • PDF

Ionization Behaviors in Various Soils Subjected to Impulse Currents (임펄스전류에 의한 토양의 종류별 이온화 특성)

  • Lee, Bok-Hee;Kim, Hoe-Gu;Park, Geon-Hun;Baek, Young-Hwan
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.12
    • /
    • pp.87-94
    • /
    • 2008
  • This parer presents the soil ionization phenomena and parameters associated to characterize the transient performances of grounding system under lightning impulse Currents. Ionization properties in occurring some soil media were experimentally investigated. The cylindrical test cell was employed in order to facilitate the analysis of soil breakdown field intensity and ionized radius. The soil breakdown field intensity, dependence of impedance on the amplitude of impulse current, V-I curves and transient impedances were discussed based on the voltage and current oscillograms. It was found that the ionization process and dynamic behaviors were strongly dependent on the types of soil and two current peaks were not observed in highly water-saturated soils. The results presented in this paper will provide useful information on the improvement of transient performance of a grounding system subjected to lightning impulse Current considering the soil ionization.

A experimental study on the improvement of lightning impulse voltage waveforms (뇌임펄스전압파형의 개선에 관한 실험적 고찰)

  • Lee, J.G.;Kim, M.K.;Jeong, J.Y.;Kim, I.S.;Choi, I.S.;Moon, I.W.;Kang, Y.S.
    • Proceedings of the KIEE Conference
    • /
    • 2004.07c
    • /
    • pp.1854-1856
    • /
    • 2004
  • In this paper, there have been brief review about the important consideration in laboratory planning and designing 4.2MV impulse voltage generator(IVG), which enable to test and evaluate the UHV dielectric performance of power electric apparatus up to 765kV-class. To improve and reinforce the test ability of the IVG and itself against test object being tested by KERI hereafter, wide investigation and an analysis for a solution, especially overshoot compensation method. With the special consideration about those matters in settling down the 4.2MV IVG have been described with the experimental approaching.

  • PDF