• Title/Summary/Keyword: Lightning impulse test

Search Result 112, Processing Time 0.029 seconds

A Study on the Compensation Method in the Measuring System for Chopped Lightning Impulse (충격전압 재단과 측정을 위한 보상회로에 관한 연구)

  • Kim, Ik-Soo;Kim, Young-Bae;Kim, Jin-Gi;Kim, Min-Kyu
    • Proceedings of the KIEE Conference
    • /
    • 1996.07c
    • /
    • pp.1895-1897
    • /
    • 1996
  • Lightning impulse voltage is essential to evaluate the insulation performance of electric power apparatus. Recently international standard (IEC-60) on high voltage measurement techniques are being revised. In the draft of this standard, a new calibration method is introduced and the accuracy of most industrial measuring systems is maintained by means of comparison test against the reference measuring systems. Comparison tests of dividers for chopped lightning impulse measurement were rallied out by KERI. The 700kV shielded resisitive divider with and without compensation element were done comparison test with 300kV PTB divider which have the similar charateristics as that were circulated among the laboratories. This paper reports on the calculation results of response charateristics obtained by EMTP and the comparison test results with chopped lightning impulse voltages from 150kV to 250kV. It is demonstrated that KERI are capable of realizing the idea in the revision of the IEC standand, that is, to establish traceability.

  • PDF

Development of Standard Resistor Divider for Full Lightning Impulse Voltage (전파 뇌충격전압 측정용 표준 저항분압기의 개발)

  • Kim, Ik-Soo;Moon, In-Wook;Kim, Min-Kyu;Kim, Yung-Bae;Kim, Jin-Gi;Lee, Hyeong-Ho
    • Proceedings of the KIEE Conference
    • /
    • 1994.07b
    • /
    • pp.1633-1635
    • /
    • 1994
  • This paper presents the development technology of standard resistor divider for full lightning impulse voltage. The ability of high voltage bulk power equipment to withstand lighting stroke is usually evaluated by means of full lightning impulse voltage. Lightning impulse voltage test has been essential to evaluate the insulation performance of electrical power apparatus. Recently International standard (IEC 60) on high voltage measurement techniques is being revised and requests a formal traceability of high voltage measurements. Therefore, general interest for this area has grown considerably during last years, and several international intercomparisions have been completed already worldwide, i.e. Europe, Japan, America etc.. In this viewpoint, we have also investigated the standard resistor divider with shield, which satisfies the IEC recommendation.

  • PDF

Effects of Lightning Surges on the Life of ZnO Varistors (뇌서지가 ZnO바리스터에 미치는 영향)

  • Lee, Bong;Lee, Su-Bong;Kang, Sung-Man;Lee, Bok-Hee
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.55 no.5
    • /
    • pp.257-262
    • /
    • 2006
  • To evaluate the change in protective levels of zinc oxide (ZnO) varistors after the surge absorption, this paper investigated the effects of the number of injection and amplitude of lightning surges on the life of ZnO varistors for low voltages. Leakage currents flowing through ZnO varistors subjected to the $8/20{\mu}s$ impulse currents under 60 Hz AC voltages were measured. The surge simulator system ECAT that can generate $8/20{\mu}s$ impulse currents with a peak short-circuit of 5 $[kA_p]$ was used. The ZnO varistor leakage current increases with exposure to impulse current, and the number of injection of $8/20{\mu}s$ impulse currents to breakdown was inversely proportional to the amplitude of the test current. Behaviors of ZnO varistor leakage currents were strongly dependent on the number of injection and amplitude of $8/20{\mu}s$ impulse currents. ZnO varistors degrade gradually when subjected to impulse current, and the resistive leakage current flowing through ZnO varistors subjected to the $8/20{\mu}s$ impulse currents under 60 Hz AC voltages was significantly increased after a certain number of injection that is dependent on the amplitude of the test impulse current. As a result, the life of ZnO varistors mainly depends on the amplitude and occurrence frequency of lightning surges.

Series-Gap Characteristics of Polymeric Arrester for Transmission Line (송전선로용 폴리머 피뢰기의 직렬공극 특성)

  • Cho, Han-Goo;Yoo, Dae-Hoon;Lee, Young-Sun;Kim, Jong-Che
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.06a
    • /
    • pp.491-492
    • /
    • 2008
  • This paper describes the series-gap characteristics of transmission line arrester with switching and lightning impulse flashover test. The transmission line arrester exhibited external gap because it is must not flashover with switching impulse on the other hand it is must flashover with lightning impulse. In accordance, minimum and maximum length of series-gap was determinated with these tests. As gap length is increased flashover voltage was increased in the range of 315.4 kV~496.3 kV and negative polarity exhibited a high voltage. As a result, It was thought tat the series-gap length of transmission line arrester exhibited in the range of 580 mm~1100 mm.

  • PDF

Change of the Microstructure of ZnO Arrester block by Lightning Surge Current and Ageing test (뇌서지전류와 Ageing에 의한 산화아연형 피뢰기 소자의 미세구조변화)

  • Lee, Bok-Hee;Kang, Sung-Man
    • Proceedings of the KIEE Conference
    • /
    • 2000.07c
    • /
    • pp.1877-1879
    • /
    • 2000
  • This paper deals with the change of the micro-structure of ZnO associated with lightning surge current and ageing test. In this work, a surge current generator which can produce 8/20 [${\mu}s$], 6 [kA] impulse current is designed and fabricated to simulate the lightning impulse current. The residual voltage and leakage current flowing to ZnO blocks are observed. Also a compensation circuit was used in resistive current measurement. The micro-structures of ZnO arrester block were significantly changed by lightning surge current and accelerated temperature ageing test.

  • PDF

HY 1600kV/70kA Impulse Voltage/Current Test Facility (한양대학교 1600kV/70kA 충격 전압/전류 시험설비 구축)

  • Chang, Yong-Moo;Kim, Cheol-Ho;Hwang, Ryul;Lee, Bang-Wook;Koo, Ja-Yoon
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.11a
    • /
    • pp.229-229
    • /
    • 2009
  • This Impulse Voltage and Current Test System is designed for performing of impulse voltage tests with Lightning impulse voltage 1.2/50(LI) up to 1520kV peak value and switching impulse voltages 250/2500(SI) up to 1120kV peak valu acc. to IEC 60060-1, and furthermore for impulse current test, e.g. testing of arrester sections($U_{res}$=95kV)with current impulses 4/10 and 8/20 up to 70kA peak value.

  • PDF

Solid Core Suspension Disc Insulators Preventing Puncture Caused by Steep Front Surge Voltage

  • Sangkasaad, Samruay
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • v.3C no.5
    • /
    • pp.165-170
    • /
    • 2003
  • This paper presents development of solid core suspension disc insulators (cap and cap suspension disc insulator) for replacing cap and pin suspension disc insulators in overhead transmission and distribution lines which expose to lightning discharges. By this means the punctured problem caused by steep front surge voltage created by lightning discharge on the lines can be solved. The solid core suspension insulator was designed and constructed based on the dimensions of conventional suspension disc insulators (cap and pin insulators). The insulators are made of alumina porcelain. The electrical and mechanical characteristics of the solid core suspension insulators were carried out. The puncture test was performed in the air by applying steep front impulse voltage with amplitude about 2.5 per unit of 50% flashover (CFO) of the insulator unit at negative standard lightning impulse $1.2/50\;\mu\textrm{s}$ with steepness up to $9200\;kV/\mu\textrm{s}$. The testing results show that solid core suspension disc insulators are not punctured eventhough the steepness of the steep front impulse voltage was increased up to $9200\;kV/\mu\textrm{s}$.

Design Circuit Parameter Estimation of Impulse Generator and its application to 10/350${\mu}s$ Lightning Impulse Current Generator (임펄스 발생기의 회로 설계 파라미터 예측계산과 10/350${\mu}s$ 뇌임펄스 전류발생기 적용)

  • Lee, Jae-Bok;Shenderey, S. V.;Chang, Sug-Hun;Myung, Sung-Ho;Cho, Yuen-Gue
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.10
    • /
    • pp.1822-1828
    • /
    • 2008
  • This paper presents design parameter calculation methodology and its realization to construction for the 10/350${\mu}s$ lightning impulse current generator(ICG) modelled as double exponential function waveform with characteristic parameters ${\alpha},{\beta}$. Matlab internal function, "fzero" was applied to find ${\lambda}={\alpha}/{\beta}$ which is solution of nonlinear equation linearly related with two wave parameter $T_1$ and $T_2$. The calculation results for 10/350${\mu}s$ lightning impulse current show very good accuracy with error less 0.03%. Two type of 10/350${\mu}s$ ICGs based on the calculated design circuit parameters were fabricated by considering the load variation. One is applicable to the MOV based Surge protective device(SPD) for less 15 kA and the other is to test small resistive devices such as spark gap arrester and bonding device with maximum current capability 30 kA. The tested waveforms show error within 10% in comparison with the designed estimation and the waveform tolerance recommended in the IEC 61643-1 and IEC 60060-1.

Degradation properties of ZnO surge arrester due to lightning impulse current (뇌임펄스 전류에 의한 ZnO 배전용 피뢰기의 열화특성)

  • Lee, Seung-Ju;Lee, Bok-Hee;Lee, Su-Bong;Kim, Dong-Soung;Shin, Hee-Kyung;Jung, Dong-Cheol
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.1305-1306
    • /
    • 2008
  • In this work, in order to investigate the effect of lightning impulse currents on ZnO surge arrester. and the deterioration characteristics of ZnO surge arrester, 8/20 [${\mu}s$], 2.5 [kA] impulse currents were applied to the ZnO surge arrester under test. The leakage currents of ZnO surge arrester were measured and ZnO element was analyzed by X-ray photoelectron spectroscopy. As a result, the resistive leakage current of ZnO surge arrester was increased with the injection number of lightning impulse currents.

  • PDF

Analysis of Malfunction Characteristics of High Sensitivity Type Earth Leakage Circuit Breaker for 30[A] due to Lightning Impulse Voltages (뇌임펄스전압에 대한 30[A]용 고감도형 누전 차단기의 오동작에 대한 특성의 해석)

  • 이복희;이승칠;김찬오
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.11 no.6
    • /
    • pp.96-103
    • /
    • 1997
  • This paper deals with the malfunction characteristics of the earth leakage circuit breakers(ELBs) applied by a lightning impulse voltage. In the cases of the regulation of KS C 4613 and the simulated circuits with surge protection devices, the dead operation characteristics of the ELBs against lightning impulse voltages were experimentally investigated and discussed. As a result, all the specimens(ELBs) used in this work have a cutoff performance of the lightning impulse voltage when the differential mode surges were injected at the input terminals of the ELBs owing to a surge absorber installed at the power source side of amplification circuit. Four kinds of the specimens have brought about malfunction in the condition of the lightning impulse dead operation test defined in KS C 4613, and the malfunction voltages are relatively high and are about 5-6.5[kV]. In the case of the simulated test circuit with surge protection devicesthree kinds of the ELBs have led to malfunction. Also the voltage level causing the malfunction of the ELBs is decreased by operation of surge protection devices, and it ranges from 3 to 5(kV).

  • PDF