• Title/Summary/Keyword: Lighting facilities

Search Result 199, Processing Time 0.031 seconds

A study on present status and improvement of protection relay system in subway station for stable power supply (지하철 역사의 안정적 전원공급을 위한 보호시스템 검토)

  • Na, Jong-Woo;Jo, Won-Kang;Park, Dong-Seon;Yoo, Yeon-Seong;Moon, Hwa-Soo
    • Proceedings of the KSR Conference
    • /
    • 2008.06a
    • /
    • pp.433-444
    • /
    • 2008
  • Nowadays, subway station has provided not only transportation but living spaces for everyday activities. Therefore, a variety of facilities have been installed for a safety of citizens such as fire-fighting equipment, platform screen doors and giving high level of benefits such as air-conditioning and heating equipment, escalators, lighting apparatus. In order to operate these facilities appropriately, it is needless to say that electric power supply must be reliable. Many protection relays have been installed to protect electric apparatus and power system, nevertheless it..s study has been insufficient in the concrete. From this paper, through analyzing of protection relay system of electric room operated in line 2 of Seoul metro, we can help to improve stable power supply system of subway station.

  • PDF

A Study on the Environmental Design of the classroom in Elementary Schools with Particular Reference to Natural Lighting and Sound Insulation Performance (채광 및 차음성능을 고려한 초등학교 교실의 환경계획적 연구)

  • Son, Chang-Hwan;Choi, Young-Jun;Lee, Kyung-Hoi
    • Journal of the Korean Institute of Educational Facilities
    • /
    • v.4 no.2
    • /
    • pp.13-20
    • /
    • 1997
  • The total evaluation of educational environment is needed with the rapid growth of the number of students. Especially it is very important to evaluate the physical environment of the classroom in elementary schools where the students spend their whole school life. This study aims to evaluate the daylighting and sound insulation performance of the classroom in elementary school, considering factors such as ceiling height and Wi/Wa (Window/Wall) ratio and then to plan the classroom. Analytic results of the daylighting and sound insulation performance show that the optimum Wi/Wa ratio is $35{\sim}45%$. Reduction of the ceiling height from 3.3m has little influence on the distribution of the indoor daylight factor and sound insulation performance

  • PDF

Harmonics Measurement and Analysis on Industrial load Facilities (산업용 부하설비의 고조파 측정 및 분석)

  • Han, Wun-Dong;Ji, Pyeong-Shik
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.9 no.2
    • /
    • pp.133-139
    • /
    • 2006
  • Harmonics happened due to nonlinear systems such as UPS, SCR controlled motors, and fluorescent lighting in distribute power system is very important subject to optimal operation and control of power system. Harmonics sometimes make incorrect operation of protective relaying system under normal condition on power system. In this study, total harmonics distortion(THD) of power were measured and analyzed by the field test on electrical facilities which were installed at the rural industrial complex in Chungbuk province. In addition, the deprivation of power factor by harmonics and the content of THD which is measured at neutral line was researched.

  • PDF

Automated Maintenance Inspection System for Unmanned Surveillance Equipment (무인감시설비를 위한 유지보수 자동화 점검 시스템)

  • Chae, Min-Uk;Lee, Choong Ho
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.22 no.1
    • /
    • pp.1-6
    • /
    • 2021
  • Recently, unmanned facilities have been introduced and operated in a way that reduces the cost and development of IT technology. Although unmanned facilities have advantages in terms of efficiency and economy, they have disadvantages such as failure of unmanned facilities and malfunctions, causing damage to facilities caused by intruders, and information leakage. In addition, it is necessary to visit the person in charge at all times to inspect the unmanned facilities, resulting in management costs. In this paper, we designed a system that checks the status of unmanned surveillance facilities in real time to check and automatically recover problems such as malfunctions, and to notify managers of situations by text messages in real time. The system to be designed consists of an integrated network video server (NVR) that receives and determines information on the operation status of the main equipment such as video, sound, and lighting, and a real-time text message using an SMS server.

A Study on the Guideline of Toilets Design for Elementary Lower-Grade Students - Based on the Survey for Elementary Schools under Seoul Gangseo District Office of Education - (초등학교 저학년 화장실 공간디자인 개선에 관한 연구 - 서울강서교육지원청 관할 초등학교 사례조사를 바탕으로 -)

  • Yoon, Hyun-Young;Jeong, Yoo-Na
    • Korean Institute of Interior Design Journal
    • /
    • v.22 no.1
    • /
    • pp.307-317
    • /
    • 2013
  • Elementary school's physical environment is critical to lower grade students. Among the many physical conditions, Toilet, which belongs to health and sanitation category is very important to those who start school for the first time. The purpose of this study is for suggesting the guidelines of toilet design reflecting psychological and behavioral aspects of lower grade students. The research was executed as follows. Firstly, focused survey groups were carefully chosen. Five elementary schools were selected, being all open after 2005 under Seoul Gangseo District Office of Education. Secondly, field study was executed to find out toilet usage, during the period between April to June 2012, by visiting schools to see basic facilities, taking pictures and making actual measurement in each toilets. The architectural analysis was focused on location, moving line, actual size and space zoning, while the interior analysis being on finishing materials and the design of sanitary equipments. And the design elements such as color, lighting fixture, art works or signage were analysed, too. Finally, questionnaire survey was done to find out preferences of lower grade students. As a result, the guidelines of toilet design can be divided into two main parts, Physical and Psychological. For the Physical part, it is necessary for related facilities to be concentrated in order to give easy access. In addition, good ventilation, better lighting and to install sanitary equipments ergonomically are required. Furthermore, safe and clean maintenance should be considered. Psychologically, the design should be directed for making lower grade students come to toilets with comfort and more pleasantly.

Causal Analysis of Education Function Space Parameters of University Dormitory (대학기숙사 교육기능공간의 매개변수를 통한 인과분석)

  • Park, Hang-Ja;Park, Sung-Jin;No, Young-Ran
    • Journal of the Korean housing association
    • /
    • v.21 no.4
    • /
    • pp.23-31
    • /
    • 2010
  • This study aims to examine the educational function space of university dormitories at local universities with corridor centered structure in Honam area regions based on direct and indirect parameters on the whole satisfaction of users in residential environment factors and personal characteristics. First, according to relations among parameters, educational and cultural activities of four major activities within the dormitory had indirect influences on social activities, eating and sleeping activities had no direct influence on other activities. And social activity had direct influence on the general satisfaction as an important parameter and educational and cultural activities had indirect influence on the whole satisfaction through social activities. Detailed results show that, in the first educational activities directly affecting the lighting and air conditioning facilities (0.22), safety (0.326), Territoriality (0.327), the space density (-0.167), directions (-0.166) and yeohyang having personal characteristics and the safety of the second cultural activities (0.183), Territoriality (0.361), Aesthetics (-0.13) and the personal characteristics Sex (-0.179), the direct effect, third, and erosion has a direct impact on activity The flexibility of the space factor (-0.128) and Territoriality (0.38) and the personal characteristics grade (0.172), respectively. Fourth in social activities directly affecting the pathfinding (-0.104), and parameter, education (0.388) and cultural activities (0.445), and some of the factors affecting the indirect lighting and air conditioning facilities, safety, and Territoriality, the space density, directions, grade, they could influence through educational activities to be analyzed. That is, territoriality in educational function space is the important factor that users react very sensitively in educational, eating and sleeping activities and educational function space must secure area and division considering personal and public use as the space accommodating activity which is lacking in unit residential space. Accordingly, the safety of educational function space in university dormitory is considered as the fundamental safety matter on the fire prevention, hygiene and cleanness for users in the satisfaction of educational and cultural activities.

Dynamic Traffic Information Provision and Dismissal Strategy for Before and After Traffic Incident (교통사고 전후 동적 정보 제공 및 해제 전략)

  • Jeon, Gyo-Seok;Kim, Tae-Wan;Lee, Hyun-Mi;Jang, Jeong-Ah
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.16 no.5
    • /
    • pp.867-878
    • /
    • 2021
  • Recently, there has been active research on smart street lamps that can collect real-time traffic data and provide traffic information by attaching images and radars to road lighting facilities. Smart street light technology can detect, identify, and provide dense information compared to existing technologies. In order to effectively utilize the smart streetlight as a high-resolution information delivery medium, a branch-type operation strategy that is different from the existing centralized operation strategy is required. This study presents dynamic information delivery strategies, release strategies, and their criteria for various purposes in a spatial range, separated by the context before and after the occurrence of smart street lights-based accidents. Through this, it is expected that smart road lighting facilities can be used more effectively.

Quality Assessment of Performance in the University Foodservice by Students Living in Incheon (인천지역 대학생에 의한 대학급식소의 급식서비스에 대한 품질 평가)

  • 노정옥;우경자;한복진
    • Journal of the East Asian Society of Dietary Life
    • /
    • v.14 no.3
    • /
    • pp.294-301
    • /
    • 2004
  • This study was conducted to investigate the quality assessment of performance of the university foodservice. Self administered questionnaires were collected from 305 students living in Incheon. Statistical data analysis was completed using a SPSS v. 10.0 program. The results were summarized as follows: 61.4% of male students and 48.1% of female students responded to have lunch regularly. Only 23.4% of male students and 14.1% of female students used the university foodservice daily. Reasons for the irregularity of lunch were responded as “lecture”, “eating when I want” and “appointment with friends”, etc. The quantity, temperature, nutritional value, appearance, hygiene, taste and freshness of foods and price of menus were evaluated as appropriate but using seasonal foods, number of side-dishes, etc. as unsatisfactory. Service speed, cloth hygiene, neatness and kindness of employee were evaluated as appropriate. For the facilities of foodservice, counter location, menu board and lighting facilities were evaluated as appropriate but heating facilities, disposition of tables and chairs of dining hall were as unsatisfactory. Sanitation of floors and walls of dining hall, restroom and utensils, etc. was evaluated as low.

  • PDF

A Study on the Renovation of Ordinary Classroom into Computer Laboratory (보통교실(普通敎室)을 개조(改造)한 컴퓨터실(室) 계획(計劃)에 관한 연구(硏究))

  • Joo, Young-Ju
    • Journal of the Korean Institute of Educational Facilities
    • /
    • v.1 no.1
    • /
    • pp.21-32
    • /
    • 1994
  • It is time to put our top priority on the computer education to cope with rapid chage in technology and expansion of information. With 6th educational reform plan, from 1995 computer courses will be offered as elective subjects in the most of middle schools. However, detail planning for training of computer courses will be offered as elective subjects in the most of middle schools. However, detail planning for training of computer teachers and providing facilicles for computer education hasn't been adequately prepared yet, This will bring about confusion in computer education. The purpose of this study is to propose how to renovate the ordinary classroom into computer classroom. Followings are the suggestions for the educational specification for the renovated computer classroom for middle school in the urban area. 1) Purpose of computer classroom, 2) Size of computer classroom, 3) Curriculum design and class hour, 4) Facilities, 5) Environments, 6) Equipment and media(lighting and electric system, acoustical treatment, cooling/heating and ventilation system), 7) Activity area(Teacher workstation, Student workstation, Support area, Display surface). For the promotion of computer education, the legal, financial and administrative supports by concerned authorities should be established ahead of discussing the contents of computer education.

  • PDF

Characteristics of Energy Consumption in an Office Building located in Seoul (사무소건물의 용도 및 측정기간에 따른 에너지 소비 특성)

  • Park Byung-Yoon;Chung Kwang-Seop
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.17 no.1
    • /
    • pp.82-87
    • /
    • 2005
  • The purpose of this study is to suggest the characteristics and actual state of energy consumption by the analysis of energy consumption data in an office building. This study examines and analyzes daily and monthly energy consumption of an office building located in Seoul, Korea regarding type of load and business classification within a building. The results are as follows. 1) Energy consumption of office building for each type of load show similar consumption patterns, regardless of seasons such as cooling period and heating period. 2) Out of all annual energy consumption, consumption for lighting took about $43\;\%,$ general electric Power about $23\;\%,$ emergency power $25\;\%,$ computer center $5\;\%$ and cooling power $4\;\%,$ showing that the consumption for lighting was highest, and the percentage of energy consumption for cooling power for operation of cooling facilities took the lowest percentage. 3) Annual gas consumption used for heating and hot water supply were $38,\;36\;\%$ for officetel and office respectively, and $26\;\%$ for arcade. 4) Electricity consumptions used for cooling power for each use of building, office and officetel recorded in July and August of cooling seasons. Even though it shows different patterns for each month, energy consumption showed unique pattern throughout the cooling seasons.