• Title/Summary/Keyword: Lighting and Cooling Energy

Search Result 89, Processing Time 0.03 seconds

Evaluation of Lateral Load Resistance and Heating/Cooling/Lighting Energy Performance of a Post-disaster Refugees Housing Using Lightweight composite Panels (경량 복합패널을 활용한 구호주거의 횡하중 저항성능 및 냉난방조명 에너지성능 평가)

  • Hwang, Moon-Young;Lee, Byung-Yun;Kang, Su-Min;Kim, Sung-Tae
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.3
    • /
    • pp.252-262
    • /
    • 2019
  • Following the earthquake in Gyeongju (2016) and Pohang (2017), South Korea is no longer a safe place for earthquakes. Accordingly, the need for shelters suitable for disaster environments is increasing. In this study, a lightweight composite panel was used to produce post-disaster housing for refugees to compensate for the disadvantages of existing evacuation facilities. For this purpose, an evaluation of structural performance and thermal environment for post-disaster housing for refugees composed of lightweight composite panels was performed. To assess the structural performance, a lateral loading test was conducted on a system made of lightweight composite panels. The specimens consisted of two types, which differed according to the bonding method, as a variable. In addition, the seismic and wind loads were calculated in accordance with KBC 2016 and compared with the experimental results. Regarding the energy performance, optimization of south-facing window planning and window-wall ratio and solar heat gain coefficient were analyzed to minimize heating, cooling, and lighting energy. As a result, the specimens composed of lightweight composite panels will perform sufficiently safely for lateral loads and the optimized window planning will lead to a low-energy operation.

An application of LT method for Design-decisions to improve energy performance of non-domestic buildings during the early stage of Remodeling Process (비주거용 건물의 리모델링 계획 시 에너지 성능 향상을 위한 LT method의 적용 방법에 관한 연구)

  • Leigh, Seung-Bok;Byun, So-Hyung
    • KIEAE Journal
    • /
    • v.3 no.4
    • /
    • pp.3-14
    • /
    • 2003
  • Remodeling for an aged building is emerging as a potential alternative towards the future of the building industry. It is a more effective method than the new construction in environmental friendly view. Most of remodeling were aimed at the improvement of the function of the deteriorated finishing materials. But, at the early stage of remodeling process, energy performance of a building can be improved by adopting passive design solutions such as daylighting and natural ventilation. The purpose of this study is to explain the passive design strategy in remodeling process and to suggest a application of LT method. LT method is an energy-design tool which responds to parameters available early in design development. It provides an output of annual primary energy for lighting, heating, cooling and ventilation in non-domestic buildings. LT method basically uses the concept of passive zone and non-passive zones and should be used to evaluate the energy performance of a number of options and to make comparisons. In this paper, the process of LT method is introduced and investigated an applicability in our office building.

A Study on the Evaluation Method for Professional ESCO (전문 ESCO 지정제 평가방안 연구)

  • Lim, Ki Choo
    • Journal of Energy Engineering
    • /
    • v.22 no.2
    • /
    • pp.90-95
    • /
    • 2013
  • The paper is aimed at evaluation method for technology-focused professional ESCO. We set up some premise about the evaluation indicators, there are such as the financial soundness, energy savings performance excellence, customer satisfaction, source technology vendor's participation, and guaranteed savings contract. The evaluation indicators consist of the evaluation of expertise (40points), management state (15points), customer satisfaction (20points), technical skills (25points), and detailed indicators were determined. We can apply technology categories such as lighting, cogeneration, process improvement, waste heat recovery, cooling & heating equipments.

Annual Intensities (2016-2017) Analysis of Energy Use and CO2 Emission by End Use based on Measurements of Sample Apartment Units (표본건물 계측에 의한 공동주택 세대에서의 용도별 에너지사용량 및 CO2 배출량 연간 원단위 (2016 - 2017) 분석)

  • Jin, Hye-Sun;Lim, Han-Young;Lee, Soo-Jin;Kim, Sung-Im;Lim, Jae-Han;Song, Seung-Yeong
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.34 no.7
    • /
    • pp.43-52
    • /
    • 2018
  • In this study, annual site and primary energy use intensities (EUIs) and CO2 emission intensities (CEIs) per area by end use were estimated based on the measurement data from June 2016 to May 2017 of 50 sample apartment units in Seoul. In addition, estimated site EUIs by end use were compared to the U.S. Residential Energy Consumption Survey (RECS) 2009 data. Site EUIs by end use were found to be in the order of heating > electric appliance > domestic hot water > cooking > lighting > cooling > air movement. In the case of primary EUIs and CEIs by end use, electric appliance was found to be the largest. As results of comparison with the RECS 2009 data, it was found that site EUIs were very similar for heating, domestic hot water and electric appliance, etc., but slightly different for cooling. The number of sample apartment units will continue to increase until 2020 (total number of samples 200) and intensities data by end use will be continuously updated through continuous collection of measurement data.

Interior heating effect in an office building according to heat properties of light fixture (업무용 건축물의 실내 조명기구 특성에 따른 발열 효과에 관한 연구)

  • Lee, Yoon-Jin;Ahn, Byung-Lip;Kim, Jong-Hun;Jeong, Hak-Geun;Jang, Cheol-Yong;Kim, Tae-Yeon
    • KIEAE Journal
    • /
    • v.15 no.2
    • /
    • pp.117-122
    • /
    • 2015
  • Purpose: Generally, 30% of the total energy consumption in office building is used for artificial indoor lightings, and almost 75-85% of electric power in fluorescent and Light-Emitting Diode (LED) lightings can be dissipated as a form of heat into indoor environment. The heat generated by indoor lightings can cause the increase of cooling load in office buildings. Thus, it its important to consider indoor lightings as a heat and light source, simultaneously. Method: In this study, we installed two kinds of indoor lightings including fluorescent and LED lightings and measured surface temperature of both indoor lightings. In addition, we obtained ambient temperature of indoor space and finally calculated total heat dissipated from plenum area and surface of lightings. Result: Total indoor heat gain was 87.17Wh and 201.36Wh in cases of six 40W-LED lightings and 64W-fluorescent lightings, respectively.

Recent Progress in Air-Conditioning and Refrigeration Research : A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2016 (설비공학 분야의 최근 연구 동향 : 2016년 학회지 논문에 대한 종합적 고찰)

  • Lee, Dae-Young;Kim, Sa Ryang;Kim, Hyun-Jung;Kim, Dong-Seon;Park, Jun-Seok;Ihm, Pyeong Chan
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.29 no.6
    • /
    • pp.327-340
    • /
    • 2017
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2016. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) The research works on the thermal and fluid engineering have been reviewed as groups of flow, heat and mass transfer, the reduction of pollutant exhaust gas, cooling and heating, the renewable energy system and the flow around buildings. CFD schemes were used more for all research areas. (2) Research works on heat transfer area have been reviewed in the categories of heat transfer characteristics, pool boiling and condensing heat transfer and industrial heat exchangers. Researches on heat transfer characteristics included the results of the long-term performance variation of the plate-type enthalpy exchange element made of paper, design optimization of an extruded-type cooling structure for reducing the weight of LED street lights, and hot plate welding of thermoplastic elastomer packing. In the area of pool boiling and condensing, the heat transfer characteristics of a finned-tube heat exchanger in a PCM (phase change material) thermal energy storage system, influence of flow boiling heat transfer on fouling phenomenon in nanofluids, and PCM at the simultaneous charging and discharging condition were studied. In the area of industrial heat exchangers, one-dimensional flow network model and porous-media model, and R245fa in a plate-shell heat exchanger were studied. (3) Various studies were published in the categories of refrigeration cycle, alternative refrigeration/energy system, system control. In the refrigeration cycle category, subjects include mobile cold storage heat exchanger, compressor reliability, indirect refrigeration system with $CO_2$ as secondary fluid, heat pump for fuel-cell vehicle, heat recovery from hybrid drier and heat exchangers with two-port and flat tubes. In the alternative refrigeration/energy system category, subjects include membrane module for dehumidification refrigeration, desiccant-assisted low-temperature drying, regenerative evaporative cooler and ejector-assisted multi-stage evaporation. In the system control category, subjects include multi-refrigeration system control, emergency cooling of data center and variable-speed compressor control. (4) In building mechanical system research fields, fifteenth studies were reported for achieving effective design of the mechanical systems, and also for maximizing the energy efficiency of buildings. The topics of the studies included energy performance, HVAC system, ventilation, renewable energies, etc. Proposed designs, performance tests using numerical methods and experiments provide useful information and key data which could be help for improving the energy efficiency of the buildings. (5) The field of architectural environment was mostly focused on indoor environment and building energy. The main researches of indoor environment were related to the analyses of indoor thermal environments controlled by portable cooler, the effects of outdoor wind pressure in airflow at high-rise buildings, window air tightness related to the filling piece shapes, stack effect in core type's office building and the development of a movable drawer-type light shelf with adjustable depth of the reflector. The subjects of building energy were worked on the energy consumption analysis in office building, the prediction of exit air temperature of horizontal geothermal heat exchanger, LS-SVM based modeling of hot water supply load for district heating system, the energy saving effect of ERV system using night purge control method and the effect of strengthened insulation level to the building heating and cooling load.

An Energy Performance Evaluation of UFAD System under the Various Conditions of Thermal Load (실내 부하조건에 따른 바닥공조 시스템의 에너지 성능 평가)

  • Yoon, Seong-Hoon;Jang, Hyang-In;Kim, Kyung-Ah;Yu, Ki-Hyung;Suh, Seung-Jik
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.25 no.1
    • /
    • pp.14-19
    • /
    • 2013
  • The present study has been conducted for evaluating and comparing the performance of the underfloor air distribution system(UFAD) and the ceiling based air distribution system(CBAD) under cooling condition. Simulations and experiments were carried out for verifying the model by TRNSYS program about UFAD and CBAD. The results of simulation for various conditions of thermal load are summarized as followings. UFAD had an advantage for making thermal comfort because of lower temperature of the floor surface. Moreover, UFAD showed lower fan power about 30~50% than CBAD under the same conditions of thermal load. The energy saving rates of UFAD were increased to 17.7% in proportion to the thermal load on unoccupied zone(lighting). Ultimately, additional investigations should be done for analyzing optimized operating conditions of UFAD with considering the thermal performance of building envelop and the thermal load.

Experiment on measures of heat collection for passive solar water wall systems that provide heat storage and natural lighting control (축열과 채광조절을 겸한 자연형 태양열 수벽시스템의 집열방식별 성능실험)

  • Oh, Young-hoon;Choi, Ji-eun;Lee, Chul-sung;Yoon, Jong-ho
    • KIEAE Journal
    • /
    • v.16 no.4
    • /
    • pp.63-69
    • /
    • 2016
  • Purpose: This preliminary study investigated a potential of the water wall systems that provide heat storage and natural lighting control simultaneously. Method: In order for transparency of the water wall to be controlled, the study first proposed two measures: to adjust transparency of the water wall; to control transparency of water wall surface. The performance of two measures then was verified and compared by experiments. In addition, a trade-off between heat collect and heat storage resulting from using additive for adjusting transparency was investigated. Result: The experiment showed that the two measures are similar in performance. The investigation of trade-off relation showed the additive should have the same heat storage as the water to prevent decrease in thermal performance of the water wall. As an economical measure to control transparency of the water wall, this study suggested a measure of secondary heat transfer systems using shading device that first absorbs solar radiation and then transfers heat to the water wall. The experiment show that performance of the proposed measure is similar to controlling transparency of water wall surface. In conclusion, it is expected that the performance of the water wall can be economically maximized by using the proposed mean in terms of heating, cooling and lighting energy saving.

A Study on the Life Cycle Cost Analysis of the See-through a-si Building Integrated Photovoltaic System (투광형 비정질 BIPV 시스템의 LCC 평가에 관한 연구)

  • Lee, Han-Myoung;Oh, Min-Seok;Kim, Hway-Suh
    • Journal of the Korean Solar Energy Society
    • /
    • v.29 no.1
    • /
    • pp.1-10
    • /
    • 2009
  • This study was carried out to evaluate the Life Cycle Cost(LCC) of three types of RTPV(Building Integrated Photovoltaic) systems-Glass plus Granite. Crystalline BIPV and See through Amorphous BIPV-which were vertically installed to generate the same power output(76 kW level). Initial investment costs. cost. savings and maintenance costs had been predicted during the period of analysing the LCC of three types of BIPV(Building Integrated Photovoltaic) systems installed for the purpose of evaluating the LCC. In case of cost savings, it had been analyzed by measuring the amount of electric power generated, reduction in lighting load and heat & cooling loads through simulation. From this analysis, it was predicted that the See-through amorphous BIPV offering cost saving advantages demonstrated the economical efficiency similar to the Class plus Granite when it is backed by more than 20 years of durability.

Renovation of Closed School Using Sustainable Method - From Closed School to Artist Studio Complex - (환경친화적인 리노베이션 기법을 적용한 폐교의 재활용 - 폐교를 이용한 복합 예술작업공간 설계 -)

  • Hong, Seung-Shin;Rieh, Sun-Young
    • Journal of the Korean Institute of Educational Facilities
    • /
    • v.9 no.4
    • /
    • pp.95-102
    • /
    • 2002
  • The purpose of this study is to renovate a closed school to a artist studio complex applying sustainable principles and methods. Through the case study, the principle and methods of sustainable renovation is investigated and following strategies are extracted as a frame of renovation. First, atrium space with thermal mass using existing wall is proposed as a public gathering space. Second, light shelves for effective lighting and shading device for protecting and allowing sun light is proposed to renovate existing classroom. Third, double skin system is proposed with reflection pool to activate heating and ventilation for passive solar as well as passive cooling. Finally, simulation programs such as energy-10 and Form-Z is used to confirm the validity of the sustainable design.