사무소를 위한 조명설계 자료의 개발과 검증 (조명에너지와 냉방부하를 중심으로) (Verification and Development of Lighting Design Data for Office in Korea (Focused on the Evaluation of Lighting Energy and Cooling Load))

  • 김은희;서승직
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.1043-1048
    • /
    • 2006
  • This paper aimed to verify and develop lighting design data for offices in Korea. It focused on a Korean standard office value relative to lighting density and the evaluation of lighting energy and cooling load. When planning indoor lighting design, we generally utilize the lighting density value which is set $14W/m^2$ by the ASHRAE/IES standard office value. However, the value is not appropriate to apply in Korea where higher efficiency lamps are more popular than others. For calculation of a proper lighting density of Korea, we analysed distribution curves of luminous intensity(2-lamp fluorescent lighting fixture with Parabolic) and derived the new lighting density $12.64W/m^2$ as Korea standard office value. In the simulation using this value, it was shown that lighting energy and cooling load could be reduced.

  • PDF

사무소 건물의 외피요소가 냉난방 및 조명에너지 소비에 미치는 영향에 관한 연구 (A Study on the Effect of Envelope Factors on Cooling, Heating and Lighting Energy Consumption in Office Building)

  • 손장희;양인호
    • 조명전기설비학회논문지
    • /
    • 제26권2호
    • /
    • pp.8-17
    • /
    • 2012
  • The objective of this study is to perform an analysis of the heat(heating and cooling) and lighting energy consumption according to the window area ratio and the application of horizontal louver, which is external shading device installed for the purpose of energy savings in office buildings. For this, a building was chosen as a typical example, and the heat and lighting energy consumption was calculated by using the daylight and building energy analysis simulation. The results showed that the total energy consumption, when the lighting control was applied, was reduced by an average of 11.49[%] compared to when there was no lighting control. The smaller the glazing ratio is, the less the total energy consumption is. Also, the application of the horizontal louver increases the total energy consumption under the same condition of glazing ratio.

조명발열 배기시스템의 배기위치에 따른 배기열량 실험연구 (A Study of Exhaust Air Flow for Cooling Load Reduction from Interior Lighting)

  • 오병길;정민호;원종서;이훈
    • 설비공학논문집
    • /
    • 제25권1호
    • /
    • pp.1-6
    • /
    • 2013
  • This study aims to reduce cooling energy by grasping kinds of heating load in building in order to decrease cooling energy in summer and eliminate efficiently heating load. Lighting heating value was confirmed through examination and experiment concerning lighting heating and reducible exhaustion value was extracted lighting apparatus. The optimal exhaust system by air conditioning type was suggested for applying lighting heat exhaust system and the method contributing to promotion supplying low energy architecture was suggested by predicting reduced cooling load.

Comparative study on the effect of cooling & heating loads by lighting energy of various light sources in an office building

  • Hong, Won Pyo
    • 조명전기설비학회논문지
    • /
    • 제30권3호
    • /
    • pp.94-105
    • /
    • 2016
  • The objective of the work was to evaluate the impact of lighting energy to cooling and heating consumption in medium scale office building, when currently installed fluorescent lights were replaced with various LED lighting fixtures. This evaluation comes from an integrated approach combining the proper indoor lighting environment and the thermal aspects of cooling & heating consumption in office building. These simulations were performed by coupling an appropriate luminaire analysis for energy consumption and a dynamic thermal simulation software (TRNSYS). To analyze comparative study of effects on the heating, cooling loads, and energy consumption of an LED lamp application, 2 types of LED lamp with low light power watt(LPW) 24W and high LPW 7.5W and a fluorescent lights(FL) with 37W are used respectively. Integrated building energy consumption decreased up to 3.2% when fluorescent lamps were replaced with LEDs. Thus, the high LPW of LED(7.5W) replaced with the same number of FL shows an effective energy saving and cost- effective luminary.

채광시스템과 인공조명설비의 통합기술 및 성능평가연구 (Predicted Performance of the Integrated Artificial Lighting System in Relation to Daylight Levels)

  • 김곤;김정태
    • 한국태양에너지학회 논문집
    • /
    • 제22권3호
    • /
    • pp.47-56
    • /
    • 2002
  • The office is an excellent candidate for implementing daylighting techniques because of the relatively high electric lighting power densities and long daytime use pattern. The quantity of light available for a space can be translated in term of the amount of energy savings through a process of a building energy simulation. To get significant energy savings in general illumination, the electric lighting system must be incorporated with a daylight - activated dimmer control. A prototype configuration of an office interior has been established and the integration between the building envelope and lighting and HVAC systems is evaluated based on computer modeling of a lighting control facility. First of all, an energy-efficient luminaire system is designed for both a totally open-plan office interior and a partitioned office. A lighting design and analysis program, Lumen-Micro 2000 predicts the optimal layout of a conventional fluorescent lighting fixture to meet the designed lighting level and calculates unit power density, which translates the demanded amount of electric lighting energy. A dimming control system integrated with the contribution of daylighting has been applied to the operating of the artificial lighting. Annual cooling load due to lighting and the projecting saving amount of cooling load due to daylighting under overcast diffuse sky are evaluated by a computer software, ENER-Win. In brief, the results from building energy simulation with measured daylight illumination levels and the performance of lighting control system indicate that daylighting can save over 70 percent of the required energy for general illumination in the perimeter zones through the year. A 25 % of electric energy for cooling may be saved by dimming and turning off the luminaires in the perimeter zones.

실내조명의 발열량 예측에 관한 실험 연구 (The Performance of generated Heating Energy from Interior Lighting Fixtures)

  • 최종선;임홍수;김경아;이금환;구재오;김곤
    • KIEAE Journal
    • /
    • 제10권6호
    • /
    • pp.27-32
    • /
    • 2010
  • Approximately 20 percentage of energy consumptions in buildings is consumed as lighting energy. Thus, most of the corporations of lighting fixture have launched low energy products. However, many researchers focused on the only luminous efficacy for energy conservation and used the evaluating tool of study. This can not gauge the precise cooling load related on generated heat of artificial lighting. In order to assess an effect of the temperature variation of lighting resources, the main purpose of this study is to predict the generated heating energy from lighting by measuring the thermal variation in scale model to reduce external noise. Also this paper used MX100 data logger to record at an interval of 1 minute for 60 minutes for the temperature of interior lightings such as incandescent lamp, fluorescent light, halogen lamp and LED lamp. As a result, LED lamp generated the lowest heat. On the other hand, incandescent lamp did the highest.

사무소건물의 용도 및 측정기간에 따른 에너지 소비 특성 (Characteristics of Energy Consumption in an Office Building located in Seoul)

  • 박병윤;정광섭
    • 설비공학논문집
    • /
    • 제17권1호
    • /
    • pp.82-87
    • /
    • 2005
  • The purpose of this study is to suggest the characteristics and actual state of energy consumption by the analysis of energy consumption data in an office building. This study examines and analyzes daily and monthly energy consumption of an office building located in Seoul, Korea regarding type of load and business classification within a building. The results are as follows. 1) Energy consumption of office building for each type of load show similar consumption patterns, regardless of seasons such as cooling period and heating period. 2) Out of all annual energy consumption, consumption for lighting took about $43\;\%,$ general electric Power about $23\;\%,$ emergency power $25\;\%,$ computer center $5\;\%$ and cooling power $4\;\%,$ showing that the consumption for lighting was highest, and the percentage of energy consumption for cooling power for operation of cooling facilities took the lowest percentage. 3) Annual gas consumption used for heating and hot water supply were $38,\;36\;\%$ for officetel and office respectively, and $26\;\%$ for arcade. 4) Electricity consumptions used for cooling power for each use of building, office and officetel recorded in July and August of cooling seasons. Even though it shows different patterns for each month, energy consumption showed unique pattern throughout the cooling seasons.

투광형 박막 BIPV 창호 적용에 따른 냉난방 및 조명 부하 저감에 관한 연구 (A Study on Analysis for Energy Demand of the Heating, Cooling and Lighting in Office Building with Transparent Thin-film a-Si BIPV Window)

  • 윤종호;안영섭;박장우;김빛나
    • KIEAE Journal
    • /
    • 제13권3호
    • /
    • pp.91-96
    • /
    • 2013
  • The purpose of this study was to analyze the annual energy demand including heating, cooling and lighting according to kind of windows with transparent thin-film a-Si Building Integrated Photovoltaic(a-Si BIPV) for office building. The analysis results of the annual energy demand indicated that the a-si BIPV window was reduced by 8.4% than the clear gazing window. The base model A was combinate with a-Si BIPV window area of 67% and clear window area of 33% among the total exterior area. The model B is to be applied with low-e clear glass instead of clear glass of the base model A. The model B was reduced to annual energy demand of 1% more than the model A. Therefore, By using a-si BIPV solar module, the cooling energy demand can be reduced by 53%(3.4MWh) and the heating energy demand can be increase by 58%(2.4MWh) than clear glazing window in office building. Also, Model C applied to the high efficient lighting device to the model B was reduced to annual energy demand of 14.4% more than the Model D applied to the high efficient lighting device to the model A. The Model E applied with daylight dimming control system to the Model C was reduced to annual energy demand of 5.9% more than Model C.

창호의 투과율과 블라인드 슬랫각도에 따른 빛환경 및 에너지성능 비교 연구 (Comparative Studies on Lighting Environment and Energy Performance depending on the Transmittance of Window and Slat Angle of Blind)

  • 심세라;윤종호;신우철
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2011년도 추계학술발표대회 논문집
    • /
    • pp.256-263
    • /
    • 2011
  • Recently, curtain wall structure is constructed according to increasing high rise building. Glass is usually used in opening of curtain wall structure and window area ratio is finally increased. Excessive Daylighting and solar radiation by large window area ratio cause discomfort glare and add to cooling load in the case of office that is heavy on lighting and cooling. Therefore, this study suggests to use low transmittance window for solve those problems. Indoor lighting environment and building energy performance were analyzed by increasing transmittance from 10% to 90% and comparing fixed venetian blind. Consequently, the range of transmittance that is possible to daylighting and prevent discomfort glare. Secondary energy consumption is efficient in the case that transmittance is the range of from 20% to 50%, primary energy consumption is nice on from 20% to 40%. If those result put together, the range of window transmittance from 30% to 50% is proper in the office in lighting environment and energy consumption aspects.

  • PDF

동적열해석프로그램을 이용한 대형할인매장의 에너지 소비 특성 분석 (The Energy Performance Analysis of Large Scale Store Using Dynamic Thermal Analysis Simulation Program)

  • 김병수;홍원표
    • 한국태양에너지학회 논문집
    • /
    • 제30권6호
    • /
    • pp.44-49
    • /
    • 2010
  • The purpose of this study is to analyze the situation of energy consumption and its characteristics in large scale store. The related survey is carried out in large scale store to investigate the energy consumption and energy use trend of heating, cooling, hot water, lighting, ventilation, equipments and others. The area of large scale discount store is about $65000m^2$, located in Daejeon. For Annual Energy Analysis of building, We surveyed used energy for 1 year and simulated using a building energy simulation(TRNSYS 16). The results of this study are as follows. 1)The amount of annual total energy consumption are 18615.244MWh/yr(286.4KWh/$m^2yr$), The rate of heating, cooling and base energy(for hot water, lighting, ventilation, equipments, cooking and others) is 3054MWh/yr(47kWh/$m^2yr$), 5660.09MWh/yr(87.08kWh/$m^2yr$), 9900.47MWh/yr(152.31KWh/$m^2yr$) respectively. The total used energy is higher than others building in Korea. Especially, The energy consumption of large scale store is very depends on operating period and pattern such as space temperature, occupancy, lighting system, equipments operating schedule and etc.