• Title/Summary/Keyword: Lighting Performance

Search Result 688, Processing Time 0.032 seconds

Development of Awning System using Light Shelf - Focusing on the light environment and lighting energy reduction performance improvement -

  • Jeong, Jinsoo;Lee, Heangwoo;Seo, Janghoo;Kim, Yongseong
    • KIEAE Journal
    • /
    • v.17 no.3
    • /
    • pp.5-13
    • /
    • 2017
  • Purpose: Various studies have been performed to address the issue of increased energy use by buildings. In particular, research on complex envelopes that combines diverse envelope element techniques is currently in progress in the building sector. The present study aimed to develop an awning system using a light shelf, and to verify its validity through performance evaluation. Method: In the present study, a testbed was established for the performance evaluation of the awning system using a light shelf, and the uniformity ratio and lighting energy consumption were compared and analyzed relative to those with no awning and light shelf installation (Case 1), awning installation (Case 2), and light shelf installation (Case 3). Result: 1) In the present study, an awning system using a light shelf (Case 4) where an opening is made on the awning screen and natural light can be introduced through the light shelf located at the bottom was developed. 2) The optimum standard for Case 4 obtained through the performance evaluation was a 0.6m lighting length and a 2m extension length at a light shelf angle of $30^{\circ}$. 3) Case 4 with the optimum standard had a 5.5% lower uniformity ratio than Case 2, but had a higher uniformity ratio than Case 1 and Case 3. 4) Case 4 with the optimum standard showed 13.3%, 44.6%, and 0%~8.7% lighting energy reductions compared to Case 1, Case 2, and Case 3, respectively. 5) Based on the above results, Case 4 suggested in the present study was found to be effective for indoor light environment improvement and lighting energy reduction.

A Study on Lighting Performance Evaluation of Light-Shelf using Crystal Face (결정면 적용 광선반 채광성능 평가 연구)

  • Lee, Heangwoo;Rogers, Kyle Eric;Seo, Janghoo;Kim, Yongseong
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.27 no.8
    • /
    • pp.395-401
    • /
    • 2015
  • Recently, many research studies have been carried out on the efficiency of light-shelf daylighting systems, especially comparing performance improvements and the limitations of reflective surfaces and their lighting performance. In this study, a crystal face reflective surface is proposed. The objective of the study is to evaluate the lighting performance of a crystal face light-shelf through a performance study. The performance study was carried out in a full scale test-bed in order to calculate the light distribution and energy consumption utilizing the standard indoor illumination as an index. The conclusions of the performance study are as follows. 1) The optimal angle of incidence for daylighting for both the operable flat type light-shelf and the crystal face light-shelf are taken in the natural environment on the dates of the winter and summer solstices, as well as the autumn and spring equinoxes. 2) The application and installation of the crystal face light-shelf can produce a 29.9%~34.3% increase of light distribution within the indoor space. However, the increase of light distribution can also lead to a decrease in the uniformity ratio, a design challenge that should be considered when applying a crystal face light-shelf. 3) It is possible to achieve a 7.98%~13.3% greater reduction in energy consumption when applying a crystal face light-shelf than when applying a flat type light-shelf. The increase in the number of crystal faces should concur with the analysis of the energy reduction. A limitation of the study is that only one predetermined pattern was performance tested for a crystal face light-shelf. In order to carry out further research on crystal face light-shelves, additional performance studies are needed based on alternative patterns and designs.

The Performance of generated Heating Energy from Interior Lighting Fixtures (실내조명의 발열량 예측에 관한 실험 연구)

  • Choi, Jong-seon;Lim, Hong-Soo;Kim, Kyung-Ah;Lee, Keum-hwan;Koo, Jae-Oh;Kim, Gon
    • KIEAE Journal
    • /
    • v.10 no.6
    • /
    • pp.27-32
    • /
    • 2010
  • Approximately 20 percentage of energy consumptions in buildings is consumed as lighting energy. Thus, most of the corporations of lighting fixture have launched low energy products. However, many researchers focused on the only luminous efficacy for energy conservation and used the evaluating tool of study. This can not gauge the precise cooling load related on generated heat of artificial lighting. In order to assess an effect of the temperature variation of lighting resources, the main purpose of this study is to predict the generated heating energy from lighting by measuring the thermal variation in scale model to reduce external noise. Also this paper used MX100 data logger to record at an interval of 1 minute for 60 minutes for the temperature of interior lightings such as incandescent lamp, fluorescent light, halogen lamp and LED lamp. As a result, LED lamp generated the lowest heat. On the other hand, incandescent lamp did the highest.

Influence of Lighting Schedule and Nutrient Density in Broiler Chickens: Effect on Growth Performance, Carcass Traits and Meat Quality

  • Li, Wen-Bin;Guo, Yan-Li;Chen, Ji-Lan;Wang, Rong;He, Yao;Su, Dong-Ge
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.23 no.11
    • /
    • pp.1510-1518
    • /
    • 2010
  • The study was conducted to evaluate the effect of lighting schedule and nutrient density on growth performance, carcass traits and meat quality of broiler chickens. A total of 576 day old Arbor Acre male chickens was used with a $4{\times}2$ factorial arrangement. The four lighting schedules were continuous (23 L:1 D, CL), 20 L:4 D (12 L:2 D:8 L:2 D), 16 L:8 D (12 L:3 D:2 L:3 D: 2 L:2 D) and 12 L:12 D (9 L:3 D:1 L:3 D:1 L:3 D:1 L:3 D) and provided by incandescent bulbs. The two nutrient densities were high (H, starter diet: 13.39 MJ/kg apparent metabolisable energy (AME), 23.00% crude protein (CP); finisher diet: 13.39 MJ AME/kg, 19.70% CP) and low energy and protein level (L, starter diet: 12.03 MJ AME/kg, 20.80% CP; finisher diet: 12.14 MJ AME/kg, 18.30% CP). Houses with dark curtains and solid sidewalls were used. Chickens were randomly allocated to the 8 treatments with each treatment comprising 6 replicates of 12 chickens. Feed and water were available ad libitum. Lighting schedules showed no difference (p>0.05) in growth performance at the end of the experiment. 12 L:12 D significantly reduced (p<0.05) the concentration of malondialdehyde (MDA) compared to 23 L:1 D treatment. Intermittent lighting (IL) schedules produced higher protein content (p<0.001) in breast meat. Birds on high density diets had higher body weight (BW), feed intake (FI) (p<0.001), and feed conversion ratio (FCR) (p<0.001) throughout the experiment with the exception of 36 to 42 d. High nutrient density increased (p<0.05) abdominal fat, decreased (p<0.05) the moisture loss of meat, and reduced percentage of wings and legs. There was a significant lighting schedule${\times}$diet interaction (p<0.001) on FCR for days 8 to 14 and 15 to 21. Results indicated that IL can give similar growth performance in comparison with CL, meanwhile with positive effects on meat quality by increasing protein content and decreasing the concentration of MDA. High nutrient density resulted in greater growth performance.

Lighting Simulation using Relux (Relux를 이용한 조명 시뮬레이션)

  • Hong, Sung-De
    • Journal of The Korean Digital Architecture Interior Association
    • /
    • v.11 no.1
    • /
    • pp.83-90
    • /
    • 2011
  • Lighting simulation is becoming increasingly more important as a method for design and evaluation. There is a wide range of packages that provide the accuracy and the usability in lighting simulation. Relux developed by Relux Informatik AG, Switzerland, Relux offers users innovative and high-performance light planning software with open interfaces and simultaneous access to the latest product data from luminaire and lamp manufacturers. The goals of this report is to explore some of the lighting simulation issues relating to Relux. It is hoped that it will provide some background information that will enable a designer and engineer to make some informed judgements on the potential of the current state-of-the-art in computer prediction of lighting in buildings and how this may be used to assist in building design.

PLC Filter Capacity Improvement and Efficiency Evaluation of Smart Street Lighting System (스마트 가로등 시스템의 전력선통신 필터 성능 개선 및 효율 평가)

  • Kim, Myung-Ho
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.58 no.2
    • /
    • pp.154-157
    • /
    • 2009
  • In order to give handiness to the management of the existing street lighting system which is based on the one way communication and to reduce the maintenance cost, the power line communication filter in the two way communication which is based on the CDMA communication and power line communication was improved and accordingly the stability of the communication performance was improved. Also, the efficiency of existing street lighting system and smart street lighting system was evaluated as Visual studio system. As a result, when the number of street lights is 10,000, the hours of daily work fell 50% and the number of necessary maintenance staff decreased 40%. Compared to the maintenance costs of the existing street lighting system, it could be expected to have the cut costs of almost 100 million won a year on the basis of 60 switch board and 1,200 street lights.

Optical and Performance Characteristics Analysis of LED Light Source (조명용 LED광원의 광학적특성 평가 및 성능 분석)

  • Hwang, Myung-Keun;Shin, Sang-Wuk;Cho, Mee-Ryoung;Lee, Se-Hyun;Lee, Young-Joo;Kim, Jin-Sheon
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2007.05a
    • /
    • pp.170-173
    • /
    • 2007
  • 본 논문에서는 LED광원에서 현재 가장 많이 사용되는 MR과 PAR 타입의 램프를 측정 분석하였다. 최대광도 및 광속의 측정값을 비교 분석하였다. 그러나 MR 16 및 PAR 30의 경우 관련 KS 규격상에 광속에 대한 값을 명기하고 있지 않은데 이것은 램프 뒤쪽에 반사경(다이크로익 미러)이 부착되어 있어 가시광을 일정한 방향으로 집중시키는 투광 개념의 광원이므로 광속 측정의 의미가 필요하지 않아서 인 것으로 생각된다. LED광원의 경우 LED자체의 광 확산이 매우 광범위하고, 반사경의 영향을 적게 받고 있어 사이드 방식으로 측정된 상기의 광속값은 불확도 범위이내에 존재할 것이 확실시되므로 향후 LED관련 규격의 제안시 측정이 요구될 것으로 판단된다.

  • PDF

Research on Development of a dynamic LED lighting system (동적 LED 조명 시스템의 개발에 대한 연구)

  • Choi, Jong-Dae;Kim, Hyo-In;Yun, Geun-Young
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2011.04a
    • /
    • pp.168-173
    • /
    • 2011
  • Recently, from a saving energy and environmental lighting sources point of view, using LED lighting have been increased rapidly. The colors of light was applied to the control of dimmers that is composed of red, green, blue, and white(RGBW) to improve the quality of visual environment. Moreover this study has been processed to develop adjustable dynamic LED lighting system on SPD and definitize the various spectral power distribution and color temperature of light through the control of the four dimmers. It is possible to combine up to $432^4$ kinds of light. Measurement of illuminance of range on working surface was as 7~l,831 lux. Application of visual environment for occupants can be expected according to control of lighting performance.

  • PDF

A Study on the Suggestion of a Lighting Control System Applying General Illumination and Technology of User and Location Awareness (전반조명 기반 사용자 및 위치인식기술 적용 조명제어 시스템 제안 연구)

  • Park, Juil;Lee, Haengwoo;Seo, Janghoo;Kim, Yongseong
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.27 no.10
    • /
    • pp.527-536
    • /
    • 2015
  • Studies for the reduction of lighting energy have been done using technologies such as user and location awareness. However, the focus of current research on location-based lighting control has been on energy reduction, which can lead to other issues including an imbalance in indoor illumination. This study proposes a lighting control system applying general illumination and technology for user and location awareness. The proposed lighting control system reduced lighting energy by 72.1%, 66.5% and 62.3% for 1, 2 and 3 users, respectively, compared to the On/Off lighting control system. This lighting control system causes an increase in lighting energy of 35.8% and 10.9% for 1 and 2 users compared to the lighting control system with user and location awareness, while a reduction of 9.4% was seen for 3 users. This means that the proposed system provides more effective energy reduction for a room with multiple occupants as it is based on the general lighting control scheme. The lighting control system applying general illumination and technology of user and location awareness improved the uniformity factor by 32.0%, 39.4% and 33.4% for 1, 2 and 3 users, respectively.

Comparative Luminance and Correlated Color Temperature of Work-place by a Fluorescent and LED Light Sources (LED광원과 형광광원에 의한 작업면의 휘도 및 색온도 비교)

  • Baik, Seung heon;Jeong, In Young;Kim, Jeong Tai
    • KIEAE Journal
    • /
    • v.8 no.6
    • /
    • pp.21-26
    • /
    • 2008
  • According to the tendency of energy efficiency and environment-friendly chracteristics, demend of High-efficiency lighting using LED(Light Emitting Diode)are being increased actively and applied in various fields. However, In order to adequate application of LED light sources, it is necessary to lighting environment and luminous characteristics of LED light sources. This Study aims to characterize the work-plane lighting environment by LED light sources comparing with fluorescent light sources which are widely used. For the sake of this study, a fluorescent light source and 5 LED light sources were introduced and luminance and correlated color temperature were measured to evaluate luminance contrast. The experimental model is Mock-up which is $4.9m{\times}7.2m$ with a height of 2.9m. The test room was set up partition and desks. Luminance and correlated color temperature were measured work-plane on the desk which was set up local lighting by the Radiant Imaging ProMetric 1400. The optical characteristics data of LED can give a lot of advantages to design LED lighting appliances. Hereafter, the object of research will be conducted to evaluate effects of LED light sources on working performance, survey of visual performance, preference and physiology of subjects.