• Title/Summary/Keyword: Lighting Maintenance

Search Result 119, Processing Time 0.026 seconds

A Study of Optical Characteristics for Maintenance Factors on Roadway Lighting Design (도로조명 설계에서 보수율에 따른 광학적 특성 연구)

  • Hwang, Myung-Keun
    • Proceedings of the KIEE Conference
    • /
    • 2000.07c
    • /
    • pp.2153-2155
    • /
    • 2000
  • The not an organization a branch stream the maintenance factor class on a class and the roadway type for roadway lighting design, the facted an insufficiency maintenance factor to apply our the country conditions. The consideration of maintenance factors is not being fully applied for roadway lighting design in Korea. This paper consider optical characteristics and maintenance factors as well as LID of Luminaires in designing roadway lighting. Consideration of maintenance factors that are neme specified according to LDD(Luminaire Dirt Depreciation), LLD(Lamp Lumen Depreciation), AADT(Average Annual Daily Traffic) based on IESNA regulation. The analyzed optical characteristics are applied for stagger and cross roadway types with maintenance factors in the range of 0.51$\sim$1.00 and equipment factor of 0.9.

  • PDF

A Study on the Calculation of Maintenance Factor(MF) of Tunnel Lighting in Expressway Considering the Actual Installation and Maintenance Conditions (실제 설치 및 유지보수 조건을 고려한 고속도로 터널조명 보수율 산정 연구)

  • Lee, Min-Wook;Park, Kwang-Yong;Kim, Pil-Young;Park, Yong-Jin;Kim, Hoon
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.27 no.3
    • /
    • pp.7-15
    • /
    • 2013
  • In lighting design, the calculation of maintenance factor is performed by calculation considering light source, characteristics of luminaire and environmental factors. The method to calculate the current maintenance factor applied to tunnel lighting design takes into consideration only pollution factors in tunnels. In addition, the calculation method should be change in response to changes of tunnel conditions and used light sources. In this study, the calculated factor of the maintenance factor in tunnel is determine by four calculation factors generally applied to the calculation of maintenance factor. This study examined the method of calculating the maintenance factor of tunnel lighting that can be applied according to the installation conditions in designing tunnel lighting by applying the actual installation data of luminaire.

Feasibility Analysis for Introducing ESCO Program of LED Luminaire Replacements in Schools

  • Shin, Hyunman;Jang, Woojin
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.30 no.1
    • /
    • pp.8-13
    • /
    • 2016
  • Public institutions should replace their luminaires with LED lighting by 2020 to save energy. Because the LED lighting installation rate in schools has not yet reached the legal goal, the ESCO program feasibility was investigated. The amount of electricity used, electric rates, times of use in classrooms and fluorescent lighting maintenance costs etc., as well as the elements of lighting maintenance were analyzed. In the case of schools, the lamp usage time was so short that the ESCO projects with only energy savings were impossible. In order to execute the ESCO projects, the maintenance cost savings by replacing an existing luminaire should be considered and the introduction of the relatively cheaper tube type LED lamp than the flat type LED luminaire was required.

The Economics Evaluation of Lighting System Considering Maintenance Factor (보수율을 고려한 조명시스템의 경제성 평가)

  • Sim, Sang-Man;Kim, Gi-Hoon;Hwang, Nam-keuk;Kim, Hoon
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.15 no.5
    • /
    • pp.1-7
    • /
    • 2001
  • Factors which affect largely the economics of lighting system, are initial installation costs, maintenance costs, energy costs as so on. In these costs, maintenance cost, lamp replacement labor cost, luminaire cleaning cost et al. so the economics of lighting system are evaluated different by maintenance planning. It is important to evaluate which lighting system would be economically advantageous in a initial design. In this study, the importance of maintenance factor is verified by the evaluations of the economics of lighting systems while maintenance factor is varied composition factors in ZCM which is used to calculate the average illuminance.

  • PDF

PLC Filter Capacity Improvement and Efficiency Evaluation of Smart Street Lighting System (스마트 가로등 시스템의 전력선통신 필터 성능 개선 및 효율 평가)

  • Kim, Myung-Ho
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.58 no.2
    • /
    • pp.154-157
    • /
    • 2009
  • In order to give handiness to the management of the existing street lighting system which is based on the one way communication and to reduce the maintenance cost, the power line communication filter in the two way communication which is based on the CDMA communication and power line communication was improved and accordingly the stability of the communication performance was improved. Also, the efficiency of existing street lighting system and smart street lighting system was evaluated as Visual studio system. As a result, when the number of street lights is 10,000, the hours of daily work fell 50% and the number of necessary maintenance staff decreased 40%. Compared to the maintenance costs of the existing street lighting system, it could be expected to have the cut costs of almost 100 million won a year on the basis of 60 switch board and 1,200 street lights.

A Study on Maintenance Planning for Efficient Urban Lighting in Wonju-si (원주시의 효율적인 도시조명을 위한 관리 계획에 관한 연구)

  • Lee, Yeon-So;Woo, Soo-Jin;Choi, Key-Soo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.4
    • /
    • pp.7-15
    • /
    • 2011
  • Based on the master plan, this study classified Wonju-si into five major regions and 19 areas by analyzing its night characteristics and deduced problems by analyzing quantitative light distribution of major points at the regions and areas through the measurement of illuminance and luminance and by surveying people's awareness. To develop eco-friendly night environment image of Wonju, Woju's identify was to be created by the planning for the 19 area and improvements for each type. Additionally, detailed items for maintenance were suggested by classifying them into illuminance, color temperature, luminance, lighting display, lighting time, light distribution type, and so forth.

Proposal of Lighting Power Density for Road Lighting (도로종류에 따른 조명전력 허용기준([W/m2]) 제안)

  • Lee, Sang-Jin;Lee, Min-Wook;Kim, Hoon
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.12
    • /
    • pp.42-47
    • /
    • 2011
  • The design of road lighting is aiming illuminance and luminance requirements for road lighting. In the process, various factors associated with luminaires such as luminous efficacy, light distribution, mounting height, spacing and maintenance factor are considered. However, there has been no restriction on lighting power density. In this study, lighting power density has been comparatively analyzed through a study of related data and a result of measurements on domestic roads. And, it has been analyzed by simulation results for road in which lighting conditions are variable. In terms of the limitation on power density for road lighting, road lighting can be designed using high efficacy lighting systems for energy saving.

Study on Optimized Manual Development and Optimum Lighting System within Luminance-based Tunnel (휘도기반 터널내 운전자 적정조명시스템 개발 연구)

  • Lee, Mi-Ae;Kim, Yeon-Hwa;Han, Seung-Hun;Kim, Ji-Heon
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.29 no.4
    • /
    • pp.18-29
    • /
    • 2015
  • The purposes of this research and development are as follows: first, to provide pleasant driving environments inside tunnels; second, to improve the current illumination environments lacking in diffusion luminance meters to meet tunnel lighting standards; and, third, to reduce the consumption of tunnel lighting energy accounting for approximately 65% of tunnel maintenance costs because of inadequate visual environments and tunnel operations. Further details are listed below. Firstly, an image luminance meter for tunnels that can implement the L20-method which is a tunnel luminance method that follows the international standards of CIE88, which was developed in order to improve and change the existing illumination-based tunnel lighting operation system to a luminance-based system. (The margin of error of below 5% according to the results of a test by an authorized agency and field test). Secondly, early illumination control is possible since the lighting control system that can be operated based on luminance enables interlocking control of the inside and outside of a tunnel using ethernet communication. Thirdly, guidelines for field application of the system are proposed. In addition, the luminance inducers of tunnels are found and the reflexibility of each facility that may reduce luminance of the boundaries is also proposed. Fourthly, as a result of a test bed, power consumption of luminance-based lighting operations decreased by 15.6% compared to illumination-based operations. Applying the feedback controls and maintenance factors of internal/external luminance meters, it reduced by 36.4%. Therefore, we became able to provide a luminance-based lighting operation system that complies with tunnel lighting design standards and provides a visual environment for drivers.

The Design cnd Manufacture on the Trial Manufacture of an Automatic Escalator System for the Maintenance Conservative Technology Advancement of the Solar Cell and Street Light (태양집광판과 가로등의 유지보순 기술 향상을 위한 자동 승하강장치 시작품 설계 제작)

  • Lee, Jae-Yong;Byun, Chang-Soo;Song, Hyun-Jig
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.6
    • /
    • pp.61-69
    • /
    • 2008
  • In this paper, an automatic escalator system is manufactured for concentrate lighting efficiency and maintenance improvement technology of street light used a solar condenser. It can be linked with street light used a solar condenser, improved concentrate lighting efficiency by regulating concentrate light angle of a solar condenser. It can be remove and attach to solar condenser and street light. By developing street light used a solar condenser with an automatic escalator system, the lighting efficiency of street light and the concentrate lighting efficiency of solar condenser are High. The maintenance fee of street light significantly reduce and traffic congestion during working hours of street light is prevent.

Design of a Remote Lighting Control System Using Time Division Multiplex Transmission (시분할 다중 전송방식을 이용한 원격 조명제어 설계)

  • 정성재;김일환
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2000.10a
    • /
    • pp.33-33
    • /
    • 2000
  • In this paper a new distributive control system for BA(Building Automation ) lighting control used on general microprocessors is presented. For optimal lighting control and saving energy, The system have to control the group and pattern lighting control as well as individual light control at one time. Tn this paper, This functions are accomplished with low-cost and simple microprocessor. A plurality of modulated light control terminals are connected to the central control unit through a pair of power line. This power line provide both power and signal to the each terminal and the data is transmitted through cyclic time division multiplex transmission. With this structure a low-cost distributive control system for lighting applications has been achieved, allowing energy and maintenance saving and reliability increase of the light control system.

  • PDF