• 제목/요약/키워드: Lighting Density

검색결과 90건 처리시간 0.026초

채널레터형 광고조명의 빛공해 관리를 위한 조명방식 개선효과 분석 및 단위면적당 소비전력(W/㎡) 제한 방법 제안 (Analyze the Results of Lighting Type Change and Rroposal of Power Density per Unit Area for Light Pollution Control of Channel-letter Type Advertisement Lighting)

  • 유성식;김현지;김훈
    • 전기학회논문지
    • /
    • 제67권6호
    • /
    • pp.759-766
    • /
    • 2018
  • Although the Act on the Prevention of Light Pollution Due to Artificial Lighting has been enforced since 2013, the area of advertisement lighting has made slow progress in solving the problems of light pollution. This paper first investigated institutional problems by analyzing domestic laws and regulations relating to the light pollution of advertisement lighting, and investigated and analyzed methods for reducing light pollution that were applied in overseas countries. Then, problems of light pollution were analyzed by conducting a research on the actual status of advertisement lightings installed in South Korea and applying various methods for reducing light pollution, and advertisement lighting using LED was recommended. As a method for reducing light pollution that can be applied to the process of manufacturing channel letter-type advertisement lights, power consumption per unit area ($W/m^2$) was proposed, and $100W/m^2$ was recommended as a value currently suitable for South Korea.

Regulating Natural Lighting and Ventilation of Residential Buildings in Hong Kong Policy Implications for High-rise, High-density Housing Environments in South Korea

  • Seo, Bokyong;Kim, Sung-Hwa;Lee, Jae-Hoon
    • Architectural research
    • /
    • 제16권3호
    • /
    • pp.81-92
    • /
    • 2014
  • This study discusses the features of the lighting and ventilation regulations for residential buildings in Hong Kong. Given the compact built environment and public concerns about the environmental quality of housing, various lighting and ventilation regulations have been enacted in Hong Kong. The application of building regulations on the micro scale and incentive systems on the macro scale are present, and the governments' calls for more active participation of the private sector and use of the building environmental assessment tools were also noted. Unlike South Korea, however, Hong Kong was found to adopt more performance-based standards, consider the external factors of the lighting and ventilation conditions together with the indoor elements, and provide specific design guidelines. Notwithstanding the different climatic conditions and socio-political contexts of Hong Kong and South Korea, these findings provide some policy implications for the South Korean government in its efforts to achieve a healthy environment for high-rise, high-density housing. It is suggested that the South Korean government adopt more on-site measurement methods to reflect the environmental conditions accurately and broaden the scope and scale of the implementation of the lighting and ventilation regulations with more specific, practical planning and design guidelines.

Inductively Coupled Plasma 광원 시스템의 Ne:Xe 혼합가스의 전자온도 및 전자밀도 특성 (Electronic Temperature and Density of Mixed Gases in Inductively Coupled Plasma Lighting System (Ne:Xe))

  • 최용성;구할본;이진;임종열;이경섭
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2006년도 추계학술대회 논문집 광주전남지부
    • /
    • pp.91-95
    • /
    • 2006
  • In whole world consciousness of environment maintenance have increased very quickly for the end of the 20th century. To use and disuse toxic substances have been controled at the field of industry. Also the field of lighting source belong to environmental control. And in the future the control will be strong. In radiational mechanism of fluorescence lamp mercury is the worst environmental problem. In radiational mechanism of fluorescence lamp mercury is the worst environmental problem root. In the mercury free lighting source system the Xe gas lamp is one type. And the Ne:Xe mixing gas lamp improvements firing voltage of Xe gas lamp. Purpose and subject of this study are understand, efficiency, ideal of Ne:Xe plasma which mercury free lamp. Before ICP was designed, basic parameters of plasma, which are electron temperature and electron density, were measured and calculated by langmuir probe data. Property of electron temperature and electron density were confirmed by changing ratio of Ne:Xe.

  • PDF

Influence of Lighting Schedule and Nutrient Density in Broiler Chickens: Effect on Growth Performance, Carcass Traits and Meat Quality

  • Li, Wen-Bin;Guo, Yan-Li;Chen, Ji-Lan;Wang, Rong;He, Yao;Su, Dong-Ge
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제23권11호
    • /
    • pp.1510-1518
    • /
    • 2010
  • The study was conducted to evaluate the effect of lighting schedule and nutrient density on growth performance, carcass traits and meat quality of broiler chickens. A total of 576 day old Arbor Acre male chickens was used with a $4{\times}2$ factorial arrangement. The four lighting schedules were continuous (23 L:1 D, CL), 20 L:4 D (12 L:2 D:8 L:2 D), 16 L:8 D (12 L:3 D:2 L:3 D: 2 L:2 D) and 12 L:12 D (9 L:3 D:1 L:3 D:1 L:3 D:1 L:3 D) and provided by incandescent bulbs. The two nutrient densities were high (H, starter diet: 13.39 MJ/kg apparent metabolisable energy (AME), 23.00% crude protein (CP); finisher diet: 13.39 MJ AME/kg, 19.70% CP) and low energy and protein level (L, starter diet: 12.03 MJ AME/kg, 20.80% CP; finisher diet: 12.14 MJ AME/kg, 18.30% CP). Houses with dark curtains and solid sidewalls were used. Chickens were randomly allocated to the 8 treatments with each treatment comprising 6 replicates of 12 chickens. Feed and water were available ad libitum. Lighting schedules showed no difference (p>0.05) in growth performance at the end of the experiment. 12 L:12 D significantly reduced (p<0.05) the concentration of malondialdehyde (MDA) compared to 23 L:1 D treatment. Intermittent lighting (IL) schedules produced higher protein content (p<0.001) in breast meat. Birds on high density diets had higher body weight (BW), feed intake (FI) (p<0.001), and feed conversion ratio (FCR) (p<0.001) throughout the experiment with the exception of 36 to 42 d. High nutrient density increased (p<0.05) abdominal fat, decreased (p<0.05) the moisture loss of meat, and reduced percentage of wings and legs. There was a significant lighting schedule${\times}$diet interaction (p<0.001) on FCR for days 8 to 14 and 15 to 21. Results indicated that IL can give similar growth performance in comparison with CL, meanwhile with positive effects on meat quality by increasing protein content and decreasing the concentration of MDA. High nutrient density resulted in greater growth performance.

제논 (Xe) 평판형 플라즈마 광원의 전기적 및 광학적 특성 연구 (The Electrical and Optical Properties of Xe Flat Plasma Light Source)

  • 최용성;문종대;이경섭;이상헌
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2006년도 영호남 합동 학술대회 및 춘계학술대회 논문집 센서 박막 기술교육
    • /
    • pp.86-90
    • /
    • 2006
  • Discharge of the flat lamp lighting source research are requested very much. For improving brightness, life time, efficiency of flat lamp, plasma diagnosis of the f1at lamp lighting source to understand property of lighting source is very important. Distance of discharge electrode is 5.5mm and width is 16.5mm, we have measured electron temperature and electron density measured with single Langmuir probe in flat lamp. We have tested the discharge from 100 Torr to 300 Torr pressure. The pulse is rectangular pulse with frequency 20kHz and duty ratio 20%. In result, electron temperature decreases and electron density increase as increase the gas pressure and electron temperature decreases and electron density increase as increase the voltage.

  • PDF

식물공장을 위한 인공광 회전형 스마트 조명 제어시스템 개발 (Development of the Rotational Smart Lighting Control System Using Artificial Light for Plant Factory)

  • 이원섭;김성관
    • 한국산학기술학회논문지
    • /
    • 제13권4호
    • /
    • pp.1474-1479
    • /
    • 2012
  • 회전형 스마트 조명 제어시스템은 작물 재식판에 위치한 작물들에게 필요한 광을 회전하며 공급하는 시스템이다. 기존 식물공장은 무수히 많이 설치되는 LED와 형광등과 같은 조명장치에 따라 고가의 초기 조명 시스템 설치비용이 발생 된다. 이에 본 논문은 비교적 적은 양으로 설치된 조명장치를 회전시키는 시스템을 개발하였으며, 식물이 생장하는데 필요한 광량과 광속, 광양자속 밀도(PPFD)를 계산하였다. 조명 시뮬레이션 프로그램 Relux와 시제품을 이용한 실험을 통하여 조명 모듈의 각도 변화와 블레이드의 회전속도 변화에 따른 측정 영역에서의 광량의 차이를 비교하고 분석하였다.

유도결합형 제논 플라즈마의 전자온도, 밀도 특성 (Properties of Electron Temperature and Density in Inductively Coupled Plasma of Xenon)

  • 허인성;양종경;이종찬;박대희
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2005년도 춘계학술대회 논문집
    • /
    • pp.41-45
    • /
    • 2005
  • In this paper, parameters of electron temperature and density for the mercury-free lighting-source were measured to diagnosis and analyze in Xe based inductively coupled plasma(ICP). In results at several dependences of 20~100 mTorr Xenon pressure, 50~200W RF power and horizontal distribution were especially mentioned. When Xe pressure was 20mTorr and RF power was 200W, the electron temperature and density were respectively 3.58eV and $3.56{\times}10^{12}cm^{-3}$. The key parameters of Xe based ICP depended on Xe pressure more than RF power that could be verified. A high electron temperature and low electron density with a suitable Xe pressure are indispensible parameters for Xe based ICP lighting-source.

  • PDF

유도결합형 제논 플라즈마의 전자온도, 전자밀도 특성 (Properties of Electron Temperature and Electron Density in Inductively Coupled Xenon Plasma)

  • 허인성;최기승;이종찬;박대희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 C
    • /
    • pp.2418-2420
    • /
    • 2005
  • In this paper, parameters of electron temperature and density for the mercury-free lighting-source were measured to diagnosis and analyze in Xe based inductively coupled plasma(ICP). In results at several dependences of $20{\sim}100mTorr$ Xenon pressure, $50{\sim}200W$ RF power and horizontal distribution were especially mentioned. When Xe pressure was 20mTorr and RF power was 200W, the electron temperature and density were respectively 3.58eV and $3.56{\times}10^{12}cm^{-3}$. The key parameters of Xe based ICP depended on Xe pressure more than RF power that could be verified. A high electron temperature and low electron density with a suitable Xe pressure are indispensible parameters for Xe based ICP lighting-source.

  • PDF

채광시스템과 인공조명설비의 통합기술 및 성능평가연구 (Predicted Performance of the Integrated Artificial Lighting System in Relation to Daylight Levels)

  • 김곤;김정태
    • 한국태양에너지학회 논문집
    • /
    • 제22권3호
    • /
    • pp.47-56
    • /
    • 2002
  • The office is an excellent candidate for implementing daylighting techniques because of the relatively high electric lighting power densities and long daytime use pattern. The quantity of light available for a space can be translated in term of the amount of energy savings through a process of a building energy simulation. To get significant energy savings in general illumination, the electric lighting system must be incorporated with a daylight - activated dimmer control. A prototype configuration of an office interior has been established and the integration between the building envelope and lighting and HVAC systems is evaluated based on computer modeling of a lighting control facility. First of all, an energy-efficient luminaire system is designed for both a totally open-plan office interior and a partitioned office. A lighting design and analysis program, Lumen-Micro 2000 predicts the optimal layout of a conventional fluorescent lighting fixture to meet the designed lighting level and calculates unit power density, which translates the demanded amount of electric lighting energy. A dimming control system integrated with the contribution of daylighting has been applied to the operating of the artificial lighting. Annual cooling load due to lighting and the projecting saving amount of cooling load due to daylighting under overcast diffuse sky are evaluated by a computer software, ENER-Win. In brief, the results from building energy simulation with measured daylight illumination levels and the performance of lighting control system indicate that daylighting can save over 70 percent of the required energy for general illumination in the perimeter zones through the year. A 25 % of electric energy for cooling may be saved by dimming and turning off the luminaires in the perimeter zones.

ICP 광원 시스템의 Ne:Xe Ne:Ar 혼합가스의 전자온도 및 전자밀도의 특성 연구 (The Electron temperature and Density properties of Mixing gas in ICP Lighting system(Ne:Xe, Ne:Ar))

  • 최기승;이종찬;최용성;박대희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 C
    • /
    • pp.2424-2426
    • /
    • 2005
  • In whole world consciousness of environment maintenance have increased very quickly for he end of the 20th century. To use and disuse toxic substances have been controled at the field of industry. Also the field of lighting source belong to environmental control. And in the future the control will be strong. In radiational mechanism of fluorescence lamp mercury is the worst environmental problem. In radiational mechanism of fluorescence lamp mercury is the worst environmental problem root. In the mercury free lighting source system the Xe gas lamp is one type. And the Ne:Xe and Ne:Ar mixing gas lamp improvements firing voltage of Xe gas lamp. Purpose and subject of this study are understand, efficiency, ideal of Ne:Xe and Ne:Ar plasma which mercury free lamp. Before ICP was designed, basic parameters of plasma, which are electron temperature and electron density, were measured and calculated by langmuir probe data. Property of electron temperature and electron density were confirmed by changing ratio of Ne:Xe and Ne:Ar.

  • PDF