• Title/Summary/Keyword: Lighting Color

Search Result 617, Processing Time 0.029 seconds

A STUDY ON THE ILLUMINATION OF DENTAL CLINIC (치과 진료실의 조명에 관한 실태 조사연구)

  • Choi Jong-In;Kim Yu-Lee;Dong Jin-Keun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.44 no.4
    • /
    • pp.374-382
    • /
    • 2006
  • Purpose: This study was designed to investigate the present conditions of illumination techniques in dental clinics in order to contribute improvement of operating environment. This study also aimed exploring qualitative and quantitative luminous intensity required for color temperature in dental clinic illumination, which was a critical part of esthetic dentistry. Materials and methods: A total of forty-eight local dental clinics were selected for sampling a) luminous intensity, and b) color temperature. The author measured the luminous intensity and the color temperature with lux meter and color meter respectively between 12pm and 2pm. The dental unit chair placed in the general operation positions were kept the distance 60 cm then all dental units were measured three times and averaged. The author measured the luminous intensity and color temperature with both common dental operating light and then without operating light in different office environments. The study was conducted under three conditions: 1 artificial illumination in clear day light 2. artificial illumination in cloudy day light, and 3. artificial illumination alone. Results : The results obtained were as follows. 1. The average luminous intensity in dental clinic lighting was 425 lux which was not sufficient to produce the optimal shade of the patient's teeth. Furthermore, the average luminous intensity even in full operating lighting was 9532 lux which fell short of the required level of 10,000 lux. 2. The average color temperature of all dental clinics surveyed was 5169 K which met the optimal range. However, only 33.3% fell in the correct region between 5,000-5,500 K as 25% were over 5,500 K and 41.6% were below 5,000 K. As a result, 66.7% were under insufficient color temperature conditions. 3. The dental unit chair placed next to a window, hence exposure to natural lighting, had significantly higher luminous intensity and color temperature compared to the dental unit chair which didn't have a window or natural lighting. 4. The data analysis revealed that only 6.3% of the dental clinic were met the standard of the average luminous intensity and color temperature.

Legibility Change of Commercial Vehicles Equipped with the Rear Lighting System (화물자동차 보조 후미등화장치 설치에 따른 운전자 시인성 변화)

  • Cho, Seung Jin;Lee, Chang Hee;Kum, Ki Jung
    • International Journal of Highway Engineering
    • /
    • v.15 no.5
    • /
    • pp.111-122
    • /
    • 2013
  • PURPOSES : The purpose of this system (Rear Lighting System) is to provide illumination for the driver to operate the commercial vehicle safely after dark in highway, to increase the conspicuity of the vehicle, and especially be suggesting the finest observable improvement method, depending on color and pattern of rear lighting system of truck for midnight highway traffic. METHODS : Rear lightning system as an improving way for forward commercial vehicles lighting the securing sight from human factors and the surrounding environment in midnight driving. For this one, basic materials were collected from the data analysis about many types of problems, and filed investigation for establishing Driving Simulator. also taking statistic test to human volunteers after finding recognizable distance of them. RESULTS : As a result, color with the highest visuality is amber followed by green-red-blue as in order for all road types. Especially almost no difference is found between red and green, also when the light is turn off, recognizable distances is wide difference compared to turn on the light. One more thing about study per pattern, upper and entire lighting have similar recognizable distances, but under lighting shows short distance with difficulty securing sight from medians. And straight section shows similar recognizable distances. By finding visuality improvement method depending on color and pattern of supplement taillight, it is expected to suggest quantitative judgement standard for introducing regulation and improvement of supplement taillight. CONCLUSIONS : Night time vehicle conspicuity to the rear is provided by rear position lamps. this study is showed that the color of light ramp is not important to be safe driving, most important is to turn on the light, recognizable distances is big different compared to turn off the rear light, so when the drivng dark in highway, have to turn on the light for reducing risk.

Changes in Electroencephalographic Results and Heart Rate Variability after Exposure to Green Landscape Photographs Correlated with Color Temperature and Illumination Level

  • Lee, Min Jung;Oh, Wook
    • Journal of People, Plants, and Environment
    • /
    • v.24 no.6
    • /
    • pp.639-649
    • /
    • 2021
  • Background and objective: Various images from visual display terminals (VDTs) as well as living lighting are important parts of our daily life; thus, properly controlling the lighting environment - that is, illuminance, color temperature and good images from VDTs - can have a substantial effect on improving the mental health and work efficiency in everyday life. We examined electroencephalography (EEG) and heart rate variability (HRV) responses to various lighting conditions in 25 university students as they viewed images of a green landscape or traffic congestion. Methods: EEG was performed in darkness and when the room was illuminated with 10 different light-emitting diode (LED) color temperatures, while the EEG and HRV responses to green landscape or traffic congestion image stimuli were measured in darkness and during room illumination with three different LED color temperatures. Results: We found a significant difference between darkness and high LED illumination (400 lx) at 7 (CZ, F4, FZ, O1, O2, OZ, and T6) of 30 channels, while the alpha wave activity increased during darkness. In the second experiment, the green landscape image stimuli in the 30 lx-2600 K lighting condition elicited theta wave activity on the EEG, whereas the traffic congestion image stimuli under high LED illumination elicited high beta and gamma wave activities. Moreover, the subjects exhibited better stress coping ability and heart rate stability in response to green landscape image stimuli under illuminated conditions, according to their HRV. Conclusion: These results suggest that lower color temperatures and illumination levels alleviate tension, and that viewing green landscape image stimuli at low illumination, or in darkness, is effective for reducing stress. Conversely, high illumination levels and color temperatures are likely to increase tension and stress in response to traffic congestion image stimuli.

Sensitivity Lighting System Based on multimodal (멀티모달 기반의 감성 조명 시스템)

  • Kwon, Sun-Min;Jung, In-Bum
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.16 no.4
    • /
    • pp.721-729
    • /
    • 2012
  • In this paper, human sensibility is measured on multi-modal environment and a sensitivity lighting system is implemented according to driven emotional indexes. We use LED lighting because it supports ecological circumstance, high efficiency, and long lifetime. In particular, the LED lighting provides various color schemes even in single lighting bulb. To cognize the human sensibility, we use the image information and the arousal state information, which are composed of multi-modal basis and calculates emotional indexes. In experiments, as the LED lighting color vision varies according to users' emotional index, we show that it provides human friendly lighting system compared to the existing systems.

A Study on the Luminous Environments of Architectural Building for Improvement of Night-Scape in Coastal Resort - Focused on the Gyengpo Park - (해안 휴양지의 야간경관 개선을 위한 건축물의 조명환경 연구 - 경포도립공원을 중심으로 -)

  • Cho, Won-Seok;Kim, Heung-Gee
    • Journal of the Korean Institute of Rural Architecture
    • /
    • v.10 no.3
    • /
    • pp.27-34
    • /
    • 2008
  • Recently, the outdoor lighting of architectural Facade has increased for the improvement of night-scape in urban and coastal resort. The purpose of this research is to analyze lighting characteristics; Luminance, Illuminance, Color Temperature, Chromaticity in Gyengpo Park of Eastern famous coastal resort. The result of this paper is as follows: 1) The Luminance ratio was measured that compare to the 1:10 criterion(IESNA) was in excess to the most building except "K". Because of these condition, Luminance environments was injurious to visual health the overuse of the outdoor lighting or glare to the eyes. 2) The level of vertical Illuminance value was insufficient 33.3% among the cases of survey with 4Lux standard of CIE. 3) The kinds of outdoor lighting of BLDG were increased lighting emitting diode(LED), metal halide(MH) instead of reduction trend of neon, fluorescent light, halogen. As the crisis of Energy resources we will be investigate adapt method of outdoor lighting, which design is based on economical efficiency by the use of optimum lighting.

  • PDF

Study on Human Physiological Responses to Emotional Lighting System using LED Flat Lighting (LED 면조명을 이용한 감성조명시스템의 인체 생리학적 반응에 관한 연구)

  • Kim, Kyung-Tae;Oh, Seung-Yong;Yu, Mi;Yu, Chang-Ho;Kwon, Tae-Kyu
    • Science of Emotion and Sensibility
    • /
    • v.17 no.3
    • /
    • pp.29-38
    • /
    • 2014
  • The purpose of this study was to verify human physiological responses to emotional lighting system using LED (light emitting diode) flat lighting. Subjects were ten males in their twenties without medical history to eyes. Colors of LED lighting are red, orange, yellow, green, blue, purple and colorless (white). They were stimulated by LED lighting for 5 minutes. We measured body temperature, heart rate variability (HRV) and electroencephalogram (EEG) before and after color stimulus. In case of EEG analysis, relative power ${\alpha}$ wave ratio decreased in the groups of colorless, red and orange color light. Also, sympathetic nerve was more activated than parasympathetic nerve and the body temperature was increased in the groups of colorless, red, orange, yellow color light. On the other hand, relative power ${\alpha}$ wave ratio increased and parasympathetic nerve was more activated than sympathetic nerve and the body temperature was decreased in the groups of green, blue and purple color light. The results imply that the LED color lighting system in the realistic experiment environment. In the future, studies with compounded both colors and modes according to situation or auditory as nature sound or olfactory as aroma will be required.

Effect of Different Lighting Sources on Behavior and Growth of Weanling Pigs

  • Glatz, P.C.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.14 no.2
    • /
    • pp.280-287
    • /
    • 2001
  • These studies aimed to determine how lighting might be used to improve feed intake and reduce aggressive behavior in newly weaned pigs. To examine whether this objective could be achieved an experiment was conducted to compare performance, behavior and body condition of weaners over 17-45 days, provided similar lighting quality (i.e. color temperature, color rendering index and lighting distribution) after weaning that piglets experienced prior to weaning. Triphosphor (TP) lighting to simulate daylight was provided during the day while at night, Pascal red (PR) lighting was provided to simulate the night-light piglets previously had received from infrared heating lamps. This treatment was compared to weaners provided conventional cool-white fluorescent light during the day only. Weaners on treatment lighting from 17-45 days of age showed no improvement in body weight or feed conversion at 24, 31, 38 and 45 days compared to the controls. There was, however, a significant improvement (p<0.05) in feed intake in the first week of weaning for weaners provided TP/PR lighting. Over the first 3 days of weaning, pigs on TP/PR lighting showed an increase (p<0.05) in the incidence of ear chewing but reduced (p<0.05) levels of nosing the abdomen of other pigs and reduced (p<0.05) occurrences of being stood on by other pigs. Females exhibited more (p<0.05) mounting and nosing behaviors and rubbing the heads of other pigs than males. On the other hand, males engaged in more (p<0.05) fighting, nipping, ear chewing and standing on other pigs compared to females. Pigs provided PR lighting on the first night of weaning engaged in higher (p<0.05) incidences of nosing and tail sucking behaviors, more (p<0.05) head thrusting, fighting and ear chewing compared to control pigs. The body condition of weaners provided the TP/PR lighting treatment was significantly poorer (p<0.05) compared to weaners on control lighting. In conclusion there was no improvement in production performance of weaners provided new technology lighting apart from the improvement in feed intake in the first week weaners were exposed to the TP/PR lighting.

Effects of Current Modulation Conditions on the Chromaticity of Phosphor Converted (PC) White LEDs

  • Kim, Seungtaek;Kim, Jongseok;Kim, Hyungtae;Kim, Yong-Kweon
    • Journal of the Optical Society of Korea
    • /
    • v.16 no.4
    • /
    • pp.449-456
    • /
    • 2012
  • For two well-known modulation methods, stepwise current modulation (SCM) and pulse width modulation (PWM), the effects of driving current modulation conditions on chromaticity were experimentally investigated in a white LED lighting system. For the experimental implementation of both SCM and PWM, a white LED lighting was fabricated using phosphor converted (PC) white light emitting diodes (LEDs) and a driving circuit module was developed. By using them, the variations of illuminance, color coordinates, and spectrum were evaluated under various forward current conditions. Through the analysis in color coordinates, yellow shift in SCM and blue shift in PWM were observed on chromaticity diagrams with increasing average driving current. In addition, in order to analyze color deviation quantitatively, color distance before and after current increase, and the correlated color temperature (CCT) were calculated. As a result, for the white LED lighting in both modulation conditions, the maximum difference in the calculated CCT was obtained close to 1000 K. It means that careful consideration is required to be taken in the design of illumination systems to avoid serious problems such industrial accidents.

Basic Research on Lighting Design for Learning Effect (학습효과 증진을 위한 조명설계에 대한 기초연구)

  • Lee, Boong-Joo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.4
    • /
    • pp.518-524
    • /
    • 2020
  • This study conducted basic research on an LED lighting design to improve the learning effect from brain wave analysis. The ideal environments of mathematics, language, and creative region can be different. Inside the space where the lighting environment can be experienced directly, the test subject consisted of common elements. Other lighting was blocked completely in controlled lighting conditions. The brain waves were analyzed according to the change in color temperature and illumination. The analyzer used was fabricated by EMOTIV Company. In the variable RGB LED light, the color of the light was measured, and the brain wave of each subject was determined. LED lights have variable color temperature (3000 [K], 4500 [K]. 250 [lux], 70% -350 [lux], 100% -500 [lux]). As research results, the highest concentration in a mathematics study was in the general condition of a high color temperature, in which the optimal condition was a 6000[K] color temperature and 350[lux] illumination. The optimal condition for a language study was a 4500[K] color temperature and 500[lux] illumination, and that of the creative study was 3000[K] color temperature and 500[lux] illumination. Overall, the possibility of emotional ability and concentrated learning efficiency can be improved by the LED lighting design with the color temperature and illumination.