• Title/Summary/Keyword: Light transmittance

Search Result 745, Processing Time 0.03 seconds

Evaluation of Transmittance Characteristics of Contact Lenses (콘택트렌즈의 광투과율 특성 평가)

  • Yu, Dong-Sik;Moon, Byeong-Yeon;Kim, Do-Hyung;Paik, Sun-Mok
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.12 no.2
    • /
    • pp.37-45
    • /
    • 2007
  • We have measured the spectral transmittances of UV blocking soft contact lenses, regular soft contact lenses and regular RGP lenses using the method suggested in ANSI Z80.20 standard. In order to evaluate visible light transmitting and UV blocking characteristics, we have calculated transmittances by integrating over the specific spectral ranges, i.e., visible light, UVA, UVB and UVC. We found that mean transmittances of visible light for all three categories were over 90.0 % which could be considered as within acceptable range for a contact lens. The transmittance of the UVA and UVB radiation for the UV blocking soft lenses except some cases was within UVR (Ultraviolet radiation) transmittance standard. The UV blocking ability of regular soft and RGP lenses was poor as rather expected. These results will be expected to assist clinical opticians and practitioners in utilizing the transmittance characteristics about the contact lens.

  • PDF

OPTICAL EFFECTS OF NONMETALLIC POST AND CORE SYSTEMS ON ALL-CERAMIC CROWNS (비금속 포스트 코어가 전부도재관에 미치는 광학적인 영향)

  • Kim Sung-Won;Cho In-Ho;Lim Ju-Hwan;Lim Heon-Song
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.40 no.5
    • /
    • pp.493-506
    • /
    • 2002
  • Recently as the esthetic concerns about dental prosthesis have been increased, the nonmetallic post and core systems have been introduced clinically to improve the color and the low optical transmittance of conventional casting metal post and core systems. The purpose of this study was to compare and analyze the optical transmittance and the shade changes of all-ceramic crowns with two nonmetallic post and core systems. The experimental groups were classified as follows : Total 27 specimens(9 samples in each group) were evaluated. Group I : Natural teeth as a control group Group II : CosmoPost and $Empress^{(R)}$ core (Ivoclar-Vivadent, Liechtenstein) Group III : $LIGHT-POST^{TM}$ and $LIGHT-CORE^{TM}$ (Bisco, U.S.A.) In all group, all-ceramic crowns were fabricated with the same shade of IPS $Empress^{(R)}$ II (Ivoclar-Vivadent, Liechtenstein) after abutment preparation, and then two kinds of spectrophotometers, UV 3101 PC (Shimadzu, Japan) and CM 503i (Minolta Co. Ltd. Japan), were used to measure the optical transmittance and the color value. The following results were obtained : 1. The optical transmittance of each group without all-ceramic crowns, was siginificantly decreased in order of Group III, I and II (p<0.05). 2. The optical transmittance of each group with all-ceramic crowns cemented, were siginificantly decreased in order of Group I, II and III (p<0.05). 3. In comparison with the shade of all-ceramic crowns, there were no significant differences between groups regardless of the cementation. 4. In comparison with the shade changes in each group after the cementation of all-ceramic crowns, there were no significant differences between groups. From the above results, it is thought that the selection among materials used in this study doesn't influence greatly the esthetic restoration, because the differences of optical transmittance were so small that those were clinically insignificant.

A Study of the Optimal Process Conditions of AZO:H2 Thin Film for Maximization of the Transmittance of a Blue GaN Light-Emitting Diode with a Wavelength of 470 nm

  • Hwang, Seung-Taek;Park, Choon-Bae;Hoang, Geun-C.
    • Transactions on Electrical and Electronic Materials
    • /
    • v.11 no.6
    • /
    • pp.279-284
    • /
    • 2010
  • This study has been carried out to determine the optimal process conditions of $AZO:H_2$ thin films for the maximization of the transmittance of a blue GaN light-emitting diode (LED) with a wavelength of 470 nm. The Al-doped zinc oxide $(AZO):H_2$ thin films were deposited on a sapphire substrate by radio-frequency magnetron sputtering system with varying substrate temperatures, working pressures and annealing temperatures temperature, working pressure and annealing imposed on a AZO (2wt% $Al_2O_3$) ceramic target. The effect of these variables was investigated in order to improve the light extraction efficiency of the LED. As a result, the (002)-oriented peak was found in all the $AZO:H_2$ thin films. The lowest resistivity and the best transmittance at a wavelength of 470 nm was found to be $4.774\;{\times}\;10^{-4}\;{\Omega}cm$ and 92% at a substrate temperature of $500^{\circ}C$, working pressure of 7 mTorr and annealing temperature of $400^{\circ}C$. The transmittance of the $AZO:H_2$ thin film for the Blue GaN LED was improved by approximately 13% relative to that of a ITO thin film (T = 79%).

Characteristics of Transmittance Spectrum of Korean Red Ginseng Using VIS/NIR (가시광선 및 근적외선을 이용한 홍삼의 투과스펙트럼 특성)

  • 손재룡;이강진;최규홍;김기영;강석원;최동수;장익주
    • Journal of Biosystems Engineering
    • /
    • v.29 no.4
    • /
    • pp.329-334
    • /
    • 2004
  • This study was conducted to investigate the characteristics of transmittance spectrum of Korean red ginseng using VIS/NIR spectroscopy. The results of this study were as follows; Light intensity affected the characteristics of the spectrum. For over 40% light intensity, the first and second peaks appeared at 700nm and 1,100nm, respectively. For the 20% light intensity, the first and second peaks appeared at 800nm and 1,100nm, respectively. Thus, the typical color characteristics of halogen lamp were similar to each other if over 40% of maximum light intensity power, otherwise it was not. Transmittance spectrum showed different characteristics at different portions of red ginseng. Normal red ginseng showed strong intensity at the first peak around 700nmbecause of reddish internal tissue. However, an internal white core red ginseng showed weak peak-intensity due to whitish internal tissue. There was no significant difference in the second peak at 800nm for the different internal qualities. Third peak at 900nm showed somewhat difference by internal qualities but it was difficult to find significant trend. To separate the differences of the internal qualities, intensity differences between peaks were used. It was possible to classify normal red ginseng by the differences of "peak 1 -peak 2" and "peak 1 - peak 3". In addition, shift of the first and the third peaks in the spectrum could separate normal red ginseng from others.ginseng from others.

Design and performance study of fabry-perot filter based on DBR for a non-dispersive infrared carbon dioxide sensor (비분산적외선 CO2 센서를 위한 DBR기반의 패브리 페로-필터 설계 및 성능 연구)

  • Do, Nam Gon;Lee, Junyeop;Jung, Dong Geon;Kong, Seong Ho;Jung, Daewoong
    • Journal of Sensor Science and Technology
    • /
    • v.30 no.4
    • /
    • pp.250-254
    • /
    • 2021
  • A highly sensitive and selective non-dispersive infrared (NDIR) carbon dioxide gas sensor requires achieving high transmittance and narrow full width at half maximum (FWHM), which depends on the interface of the optical filter for precise measurement of carbon dioxide concentration. This paper presents the design, simulation, and fabrication of a Fabry-Perot filter based on a distributed Bragg reflector (DBR) for a low-cost NDIR carbon dioxide sensor. The Fabry-Perot filter consists of upper and lower DBR pairs, which comprise multilayered stacks of alternating high- and low-index thin films, and a cavity layer for the resonance of incident light. As the number of DBR pairs inside the reflector increases, the FWHM of the transmitted light becomes narrower, but the transmittance of light decreases substantially. Therefore, it is essential to analyze the relationship between the FWHM and transmittance according to the number of DBR pairs. The DBR is made of silicon and silicon dioxide by RF magnetron sputtering on a glass wafer. After the optimal conditions based on simulation results were realized, the DBR exhibited a light transmittance of 38.5% at 4.26 ㎛ and an FWHM of 158 nm. The improved results substantiate the advantages of the low-cost and minimized process compared to expensive commercial filters.

A Study on Fabrication and Characteristics of Large Area Liquid-Crystal Cell for Smart-Window (스마트윈도우용 대면적 액정셀 제작과 특성에 대한 연구)

  • Lee, Seung-Woo
    • Proceedings of the KIPE Conference
    • /
    • 2019.11a
    • /
    • pp.166-167
    • /
    • 2019
  • Smart windows are used as windows and doors to determine cooling and heating efficiency in the construction field. It's characteristics can increase the energy saving efficiency. In addition, the function of the smart window that can control the light transmittance transmitted from the external environment of the building to the building according to the needs of the user is attracting attention. In this study, a liquid crystal cell capable of controlling light transmittance of 297 × 210 ㎟ was fabricated by using a liquid crystal device as an optical shutter. Analysis of transmittance change according to driving voltage and driving stability according to thermal environment, We confirmed the applicability of building exterior materials as smart windows.

  • PDF

Wear Debris Concentration Measurement by Laser Beam Attenuation (광감쇄를 이용한 마모입자의 농도 측정)

  • 강기호;손정영;전형욱;윤의성;안효석
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 1990.11a
    • /
    • pp.58-62
    • /
    • 1990
  • The size and concentration of wear debris in lubricating oil often reveal the operating condition of the rotating machinery. To evaluate the possible application of light attenuation measurement for the estimation of wear debris concentration in the lubricating oil, the light transmittance through the lubricating oil cell contaminated with various concentrations of diatomite particles was measured, the attenuation coefficient was estimated from the transmittance measurement and the coefficients were compared with those obtained from the scattering theory. The comparision showed good agreements between them. It is also noted that the experimentally determined attenuation coefficient showed almost linear relation with particle weight concentrations for the concentrations within the range of 2000 ppm. For the case of 0 ppm weight concentration of diatomite particles in the lubricating oil cell, the thickness of the cell required to give $100 \mu W$ light attenuation is 7.75 mm. This result indicates that the light attenuation method will be one of the possible candidates of machine failure diagnostic sensors for the estimation of wear debris concentration in the lubricating oil.

  • PDF

Wear Debris Coacentration Measurement by Laser Beam Attenuation (광감쇄를 이용한 마모입자의 농도 측정)

  • 강기호;손정영;전형욱;윤의성;안효석
    • Tribology and Lubricants
    • /
    • v.6 no.2
    • /
    • pp.94-98
    • /
    • 1990
  • The size and concentration of wear debris in lubricating oil often reveal the operating condition of the rotating machinery. To evaluate the possible application of light attenuation measurement for the estimation of wear debris concentration in the lubricating oil, the light transmittance through the lubricating oil cell contaminated with various concentrations of diatomire particles was measured, the attenuation coefficient was estimated from the transmittance measurement and the coefficients were compared with those obtained from the scattering theory. The comparision showed good agreements between them. It is also noted that the experimentally determined attenuation coefficient showed almost linear relation with particle weight coucentrations for the concentrations within the range of 2000 ppm. For the case of 0 ppm weight concentration of diatomire particles in the lubricating oil cell, the thickness of the cell required to give $100 \muW$ light attenuation is 7.75 mm. This result indicates that the light attenuation method will be one of the possible candidates of machine failure diagnostic sensors for the estimation of wear debris concentration in the lubricating oil.

Fabrication and characterization of plastic fiber optic temperature sensor using TSCM (TSCM을 이용한 플라스틱 광섬유 온도센서의 제작 및 특성평가)

  • Lee, Bong-Soo;Heo, Hye-Young;Cho, Dong-Hyun;Kim, Sin;Cho, Hyo-Sung
    • Journal of Sensor Science and Technology
    • /
    • v.14 no.3
    • /
    • pp.180-185
    • /
    • 2005
  • In this study, a plastic fiber-optic temperature sensor is fabricated using TSCM(thermo sensitive clouding material) which changes its light transmittance with temperature and the characteristics of this sensor are evaluated. The fabricated fiber optic temperature sensor is the reflector type using a Y-coupler. The optimum light source and reflector are decided by measuring the amount of reflected light through TSCM. Also, the optimum distance from the end of sensor to the surface of reflector is determined. Then the relationship between the amount of measured reflected light and the temperature of TSCM is found.

A Study on Improvement of the Transmittance in the Fringe-Field Switching (FFS) Mode

  • Lee, J.Y.;Ryu, J.W.;Lee, S.H.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2006.08a
    • /
    • pp.621-624
    • /
    • 2006
  • Pixel structure of the fringe-field switching (FFS) mode to improve transmittance has been studied. New FFS structures related to the electrode structure at the edges of pixel, and the pixel electrode width and distance between electrodes was optimized. The former improves transmittance by minimizing the region of disclination lines. The latter improves it by increasing light efficiency above center of electrodes and also response time.

  • PDF