• Title/Summary/Keyword: Light filter

Search Result 606, Processing Time 0.025 seconds

Development of Diagnostic Device for the Tooth Crack Using Transmitted Light (투과 광을 이용한 치아 균열 진단기 개발)

  • Yang, Jeong Su;Seo, Hyo-Gi;Lee, Joon-Seok;Choi, Keum Yeon;Cho, Jin-Hyoung
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.29 no.5
    • /
    • pp.317-320
    • /
    • 2016
  • In order to acquire clear images capable of diagnosing cracked tooth by light transmission, the optical properties of LED light source were examined. Based on the results, the prototype which basically consisted of LED light source, bandpass filter and commercial compact camera module was designed and manufactured. The wavelength and optical power of the LED in the prototype were 850 nm and 7 mW/Sr, respectively. In evaluation of the prototype using microscope, the observation of the crack with width of above $17{\mu}m$ was possible. In addition, image analysis to obtain shape information on the observed tooth cracks was carried out.

Bio-inspired Structural Colors of Transparent Substrate based on Light Diffraction and Interference on Microscale and Nanoscale Structures (자연모사기반 나노-마이크로패턴의 광 회절 및 간섭에 의한 투명기판의 구조색 구현)

  • Park, Yong Min;Kim, Byeong Hee;Seo, Young Ho
    • Journal of Industrial Technology
    • /
    • v.39 no.1
    • /
    • pp.33-39
    • /
    • 2019
  • This paper addresses effects of nanoscale structures on structural colors of micropatterned transparent substrate by light diffraction. Structural colors is widely investigated because they present colors without any chemical pigments. Typically structural colors is presented by diffraction of light on a micropatterned surface or by multiple interference of light on a surface containing a periodic or quasi-periodic nano-structures. In this paper, each structural colors induced by quasi-periodic nano-structures, periodic micro-structures, and nano/micro dual structures is measured in order to investigate effects of nanoscale and microscale structures on structural colors in the transparent substrate. Using pre-fabricated pattern mold and hot-embossing process, nanoscale and microscale structures are replicated on the transparent PMMA(Poly methyl methacrylate) substrate. Nanoscale and microscale pattern molds are prepared by anodic oxidation process of aluminum sheet and by reactive ion etching process of silicon wafer, respectively. Structural colors are captured by digital camera, and their optical transmittance spectrum are measured by UV/visible spectrometer. From experimental results, we found that nano-structures provide monotonic colors by multiple interference, and micro-structures induce iridescent colors by diffraction of light. Structural colors is permanent and unchangeable, thus it can be used in various application field such as security, color filter and so on.

Mobile Iris Recognition System Based on the Near Infrared Light Illuminator of Long Wavelength and Band Pass Filter and Performance Evaluations (장파장 근적외선 조명 및 밴드 패스 필터 기반 이동형 홍채 인식 시스템 및 성능 평가)

  • Cho, So-Ra;Nam, Gi-Pyo;Jeong, Dae-Sik;Shin, Kwang-Yong;Park, Kang-Ryoung;Shin, Jae-Ho
    • Journal of Korea Multimedia Society
    • /
    • v.14 no.9
    • /
    • pp.1125-1137
    • /
    • 2011
  • Recently, there have been previous research about the iris recognition in mobile device to increase portability, whose accuracy is affected by the quality of iris image. Iris image is affected by illumination environment during the image acquisition. The existing system has high accuracy in indoor environment. However the accuracy is degraded in outdoor environment, because the gray levels of iris patterns in image are changed, and ghost and eyelash shading regions are produced by the sunlight of various wavelengths into iris region. To overcome these problems, we propose new mobile iris camera system which uses the near-infrared (NIR) light illuminator of 850 nm and band pass filter (BPF) of 850 nm. To measure the performance of the proposed system, we compared it to the existing one with the iris images captured in indoor and outdoor sunlight environments in terms of the equal error rates (EER) based on false acceptance rate (FAR) and false rejection rate (FRR). The experimental result showed that the proposed system had the lower EERs than those of previous system by 0.96% (with frontal light in indoors), 4.94% (with frontal light in outdoor), 9.24% (with side light in outdoor), and 7% (with back light in outdoor), respectively.

Response of Striped Puffer , Fugu xanthopterus to the Colored Lights (색광에 대한 까치복의 반응)

  • 양용림
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.30 no.2
    • /
    • pp.78-85
    • /
    • 1994
  • The author carried out an experiment to find out the response of Striped puffer. Fugu xanthoperus (Temminck et Schlegel) to the color lights. The experimental tank (300L$\times$50W$\times$50Hcm) was set up in a dark room. Six longitudinal sections with 60cm intervals are marked in the tank to observe the location of the fish. Water depth in the tank was kept 50cm level. Light bulbs of 20W at the both ends of the tank projected the light horizontally into the tank. Two different colored filters were selected from four colors of red, blue, yellow, and white, and the were placed in front of the light bulbs to make different colors of light. Light intensity was controlled by use of auxiliary filiters intercepted between the bulb and the filter. The fishes were acclimatized in the dark for 60 minutes before they were employed in the experiment. Upon turning on the light, the number of fish in each section was counted 40 times in 30 second intervals, and the mean of the number of fish in each section was counted 40 times in 30 second intervals, and the mean of the number of fish in each section was given as the gathering rate of the fish. The colors favourited by the fish was found in order of blue, yellow, white and red in the daytime, and blue, white, yellow and red at night. The difference of the average distribution on two different colors of light was 13.12%(4.10-26.55%), and the difference in the daytime(14.79%) was larger than at night (11.45%). Constantly the gathering rate of fish on illumination period was fluctuated with instability. As the gathering rate of fish on illumination period was fluctuated with instability. As the gathering rate on one color of light increased, the gathering rate on the other color of light decreased. The difference of the gathering rate on two different colors of light was comparatively distinct and the difference in the daytime was larger than at night.

  • PDF

An efficient Color Edge Fuzzy Interpolation Method for improving a Chromatic Aberration (색수차 개선을 위한 효율적인 컬러 에지 퍼지 보간 방법)

  • Byun, Oh-Sung
    • Journal of the Korea Society of Computer and Information
    • /
    • v.15 no.10
    • /
    • pp.59-70
    • /
    • 2010
  • Each pixels become got pixel value for color of only one from among colors because of bayer pattern that light receiving device of image sensor which is used in HHP and digital camera writes only one color. Information of the missing pixels could infer perfect color image from using information of neighbor pixels by using CFA(Color Filter Array). In this paper, we derive relation between the average of the data from the light receiving device of image sensor and each color channel data. And by using this relation, a new efficient edge color fuzzy method for color interpolation is proposed. Also, missing luminance signal channel interpolation was fuzzy interpolation along any edges direction for reducing color noise and interpolating efficiently it. And in this paper, the proposed method has been proved improving average 2.4dB than the conventional method by using PSNR. Also, resolution of the image of the proposed method was similar to the original image by visual images, we has been verified to be decreased a chromatic aberration than image of conventional algorithms with simulation result.

STUDY ON THE CRITICAL MAINTENANCE PERIOD OF MILLIPORE FILTER MEMBRANE IN RATS (백서에서 Millipore filter membrane의 임계유지기간에 대한 연구)

  • Kim, Mi-Suk;Yeo, Hwan-Ho;Kim, Su-Gwan;Lim, Sung-Chul
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.28 no.4
    • /
    • pp.274-279
    • /
    • 2002
  • The purpose of this study is to evaluate the critical maintenance period of absorbable membrane for guided bone regeneration. Fortynine Sprague-Dawley rats weighing about 300g were divided into seven groups. An 8 mm circular full-thickness defect in calvarial bone was made and then cellular acetate porous filter (Millipore $filter^{(R)}$.) was placed on the calvarial bone defect. The filter was removed at 2, 3, 4, 5, 6, 8 and 11 weeks after placement. Rats were sacrificed at 12 weeks the placement of cellular acetate porous filter. The specimens were stained with Hematoxylin-Eosin and observed under light microscope. The amount of regenerated bone was measured from both margin of calvarial bone defect (unit : mm). The results were as follows. Bone regeneration of each experimental group was increased gradually and the bond defect was almost completely filled with new bone in 5-, 6-, 8-, and 11-week experimental group. Histologic findings showed mild inflammatory response and granulation tissue formation without apparent adverse effects on the healing process. In 11-week experimental group, the bone defect was completely filled with new bone containing abundant osteoid which was oriented to the dural side and contribute to bony thickening. We suggest that non-absorbable membrane and bioabsorbable membrane presumably should remain intact for longer than 5 weeks to be effective.

Channels Packed with Porous Media to Improve Water Quality for Irrigation Reservoirs (관개용 저수지 수질개선을 위한 접촉산화수로)

  • Park, Byung-Heun;Jang, Jung-Ryul;Kim, Young-Kyeong;Lee, Kwang-Sik;Kwun, Soon-Kuk
    • Korean Journal of Environmental Agriculture
    • /
    • v.19 no.2
    • /
    • pp.122-127
    • /
    • 2000
  • A stream purification system was applied to the upper reaches of the Masan Reservoir to improve the water quality. This system consisted of two channels which were constructed on both sides of the stream, one side packed with crushed gravels and the other with plastic filter media. The system operated under low pollutant concentrations and high hydraulic loadings during a dry season to avoid clogging of the filter media. Removal rate and efficiency of chemical oxygen demand (COD) in the channel packed with crushed gravel were $14.8g/m^3/d$ and 11.5%, and for the channel with plastic filter media, $50.1g/m^3/d$ and 13.5%, respectively. Removal efficiencies of total phosphorus (T-P) were 6.6% (gravel) and 10.0% (plastic media). These results indicated plastic filter media having relatively high specific surface areas were more efficient than crushed gravels in removing pollutants. However, due to low influent water quality during dry season, the removal efficiencies were low. The proportion of nitrate nitrogen to total nitrogen (T-N) of the inflow was high but, as the system operated under aerobic condition, nitrate nitrogen could not denitrified. Accordingly, total nitrogen was not attenuated with this system. To improve the reservoir water quality effectively, this system should be able to treat the storm runoff containing higher pollutant loadings. When the filter materials are clogged by the storm runoff instead of backwashing, it would be more efficient to replace them, Therefore, the use of natural materials which are light, easily obtaining and replaceable, and have high specific surface areas is recommended.

  • PDF

Characteristics of a Filter Module Adsorption for Fine Dust Removal on Road (도로 미세먼지 저감을 위한 필터 모듈의 흡착 특성)

  • Lee, Jai Yeop;Kim, Ilho
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.39 no.1
    • /
    • pp.19-25
    • /
    • 2017
  • In this study, a electrostatic filter which could be applicable to road environment was developed and evaluated in adsorption capacity. The evaluation were performance for removal by particle size and adsorption amount by pressure using ASERAE 52.1 and 52.2. The range of size for removal test was $0.3{\mu}m{\sim}10.0{\mu}m$ which had 12 steps. The filter showed 91.3% removal efficiency from $2.5{\mu}m$ and under the size, average 53.5% proportional to decreasing size value. The weight removal was 96.7% from 22.6 mmaq, initial pressure to 35 mmaq, end pressure with $715.9g/m^2$, the adsorption amount. The shape of isotherm was expressed as Langmuir's one. After washing saturated filter with dust to end pressure, the initial pressure and adsorption amount of the filter showed a light drop with no removal efficiency decline.

Optical waveguide structure design of Non-dispersive Infrared (NDIR) CO2 gas sensor for high-sensitivity (이산화탄소 검출을 위한 고감도 비분산 적외선 가스센서의 광도파관 구조 설계)

  • Yoon, Jiyoung;Lee, Junyeop;Do, Namgon;Jung, Daewoon
    • Journal of Sensor Science and Technology
    • /
    • v.30 no.5
    • /
    • pp.331-336
    • /
    • 2021
  • The Non-dispersive Infrared (NDIR) gas sensor has high selectivity, measurement reliability, and long lifespan. Thus, even though the NDIR gas sensor is expensive, it is still widely used for carbon dioxide (CO2) detection. In this study, to reduce the cost of the NDIR CO2 gas sensor, we proposed the new optical waveguide structure design based on ready-made gas pipes that can improve the sensitivity by increasing the initial light intensity. The new optical waveguide design is a structure in which a part of the optical waveguide filter is inclined to increase the transmittance of the filter, and a parabolic mirror is installed at the rear end of the filter to focus the infrared rays passing through the filter to the detector. In order to examine the output characteristics of the new optical waveguide structure design, optical simulation was performed for two types of IR-source. As a result, the new optical waveguide structure can improve the sensitivity of the NDIR CO2 gas sensor by making the infrared rays perpendicular to the filter, increasing the filter transmittance.

A Study on Methodology to Improve the Power Factor of the High Power LED Module (고출력 LED 모듈 역률 개선 방법 연구)

  • Lho, Young Hwan
    • Journal of IKEEE
    • /
    • v.18 no.3
    • /
    • pp.335-340
    • /
    • 2014
  • Recently, LED (Light Emitting Diode) becomes to be useful to apply for the lightening sources in electric systems and the lightening equipment since the power is less consumed with high efficiency, and the size and the weight of LED are small and light, respectively. The LED is controlled with constant current and SMPS (Switching Mode Power Supply). It is necessary for the LED manufacturer to secure the fundamental technology of designing LED chip, and to study the methodology to improve the power factor (PF) and to design the operational circuit for the development of LED to reduce the power loss in the application of LED lightening. The direct AC (Alternating Current) LED driving circuit, HV9910, is widely used in the industry field. In this paper, it is to evaluate the improved methodology for the power factor and efficiency through simulations when PFC (Power Factor Correction) and Noise Filter are added to HV9910.