• Title/Summary/Keyword: Light curing time

검색결과 148건 처리시간 0.025초

대면적 미세 성형공정 원천기술 개발 (Development of Key Technologies for Large Area Forming of Micro Pattern)

  • 최두선;유영은;윤재성;제태진;박시환;이우일;김봉기;정은정;김진상
    • 한국정밀공학회지
    • /
    • 제28권7호
    • /
    • pp.777-782
    • /
    • 2011
  • Micro features on the surface are well-known to have significant effects on optical or mechanical properties such as the optical interference, reflectance at the surface, contact angle, interfacial friction, etc. These surface micro features are increasingly employed to enhance the functionality of the applications in various application areas such as optical components for LCD or solar panel. Diverse surface features have been proposed and some of them are showing excellent efficiency or functionality, especially in optical applications. Most applications employing the micro features need manufacturing process for mass production and the injection molding and roll-to-roll forming, which are typical processes for mass production adopting polymeric materials, may be also preferred for micro patterned plastic product. Since the functionality or efficiency of the surface structures generally depends on the shape and the size of the structure itself or the array of the structures on the surface, it would be very important to replicate the features very precisely as being designed during the molding the micro pattern applications. In this paper, a series of research activities is introduced for roll-to-roll forming of micro patterned film including filling of patterns with UV curable resin, demolding of surface structures from the roll tool, control of surface energy and cure shrinkage of resin and dispose time and intensity of the UV light for curing of UV curable resin.

타액 오염하에서 수복방법에 따른 컴포머의 미세누출에 관한 연구 (A STUDY ON MICROLEAKAGE ACCORDING TO RESTORATION METHOD OF COMPOMER UNDER SALIVA CONTAMINATION)

  • 공석배;유승훈;김종수
    • 대한소아치과학회지
    • /
    • 제34권1호
    • /
    • pp.73-80
    • /
    • 2007
  • 소아 환자의 인접면 우식을 치료할 때 컴포머는 불소를 방출하는 재료로 유용하게 사용될 수 있다. 하지만 구강내 환경은 항상 습윤한 상태로 타액은 컴포머와 치질 사이의 접착을 방해할 수 있다. 수복시에 타액이 게재하게 되면 미세누출이 발생할 가능성이 높아지게 되며 그로 인해서 수복의 실패가 일어날 수 있다. 이에 본 연구에서는 컴포머를 수복할 시에 타액의 영향과 수복 방법에 따른 미세누출 정도를 평가하기 위해서 시행하였다. 컴포머로서 Dyract $AP^{(R)}$(Dentsply, Germany)를 사용하였으며 Dentin bonding agent로는 Prime and $Bond^{(R)}$ NT (Dentsply, Germany)를 사용하였고, 광중합을 위해서 Elipar Trilight (3M ESPE, USA)를 사용하였다. 구강내 환경을 재현하기 위해서 saliva pool을 제작하였다. 소구치 2개를 인접하여 시편을 제작한 후에 2급 와동을 형성하여 수복 환경을 다르게 하여 컴포머를 충전한 후에 500회 thermocycling하였다. 그 후 0.5% methylene blue 용액에 24 시간 동안 담근 후에 실체 현미경을 통해서 교합면과 치은면에서의 미세누출 정도를 측정하였다. Kruskal-Wallis Test와 Mann-Whitney Test를 이용하여 각 군간 유의성을 검정하여 다음과 같은 결과를 얻었다. 1. 교합면에서의 각 군간 통계학적 차이는 없었다(p>0.05). 2. 치은면에서 $Oraseal^{(R)}$을 이용하여 수복한 3군이 타액 오염을 시키지 않은 4군과 통계학적 차이가 없었다(p>0.05). 3. 치은면에서 1군과 2군 사이에는 통계학적 차이가 없었다(p>0.05). 4. 치은면에서 $Oraseal^{(R)}$을 이용하여 수복한 3군이 1, 2군보다 통계학적으로 더 낮은 미세누출 정도를 보였다(p<0.05).

  • PDF

이원중합형 코어 축조용 복합레진의 결합강도에 대한 NaOCI의 영향에 대한 연구 (Influence of Sodium Hypochlorite on Bond Strength of Dual-cured Core Build-up Resin Composite)

  • 이준봉;박종덕;권수미;유미경;이광원
    • 구강회복응용과학지
    • /
    • 제23권4호
    • /
    • pp.283-292
    • /
    • 2007
  • Two-step or one-step bonding systems generally inhibit curing process of dual-cured core build-up resin composite for their adhesive acidity. In addition this dual-cured core build-up resin composite can be applied to dentin of pulp chamber and root at the time that complete the endodontic treatment. The purpose of this investigation was to determine the influence of sodium hypochlorite on rnicrotensile bond strength of dual-cured core build-up resin composite. Extracted human molars were horizontally sectioned with 1mm thickness using low speed diamond saw. After the sectioned specimens were divided into 8 groups, adhesive systems (Clearfil SE-Bond, Prime&Bond NT[2-step, 1-step], Adper Prompt L-Pop) were then applied with or without sodium hypochlorite pretreatment. The treated specimen was filled with dual-cured core build-up resin composite (Luxacore, DMG corp., German). Then light cured for 40 seconds and soaked in $37^{\circ}C$ water bath for 24 hours. After the treated specimen was grinded with 1mm width and measured rnicrotensile bond strength by testing machine. Additionally 8 teeth were prepared for SEM evaluation. The results were as follows. : NaOCl treated groups generally had lower rnicrotensile bond strength but did not show any difference statistically except Adper Prompt L-Pop. When the teeth were treated by NaOCl, though the difference of applied adhesive system, it had no statistically significant difference within the NaOCl treated groups except the relation of between ClearFil SE-Bond adhesive system and Adper Prompt L-Pop adhesive system. In the SEM evaluation, NaOCl treated groups presented relatively long resin tags and incomplete hybrid layer formation generally.

응축형 복합레진 수복시 유동성 레진 이장이 변연부 미세누출에 미치는 영향 (THE EFFECT OF FLOWABLE RESIN LINING ON THE MARGINAL MICROLEAKAGE OF CONDENSABLE RESIN RESTORATION)

  • 문주훈;고근호
    • Restorative Dentistry and Endodontics
    • /
    • 제26권1호
    • /
    • pp.16-22
    • /
    • 2001
  • The purpose of this study was to evaluate the marginal microleakage of condensable composite resin restorations according to flowable resin lining of internal cavity wall. The eighty extracted human molar teeth without caries and/or restorations are used The experimental teeth were randomly assigned into four groups of ten teeth each. Eighty caries-free extracted human molars were used in this study. The conventional class II cavities (box-shaped on mesial and distal surface, faciolingual width : 3mm, gingival wall depth : 1.5mm) were prepared 1mm below cementoenamel junction with a # 701 carbide bur. The teeth were divided into four groups, and then each group were subdivided into A & B group according to flowable resin & compomer lining ; Group 1-A : Tetric Ceram filling, Group 1-B : Tetric Flow lining and Tetric Ceram filling, Group 2-A Ariston pHc filling, Group 2-B : Tetric Flow lining and Ariston pHc filing, Group 3-A SureFil filling, Group 3-B : Dyract Flow lining and SureFil filling, Group 4-A : Pyramid filling, Group 4-B : Aeliteflo lining and Pyramid filling. To simulate as closely as possible the clinical situation during retoration placement, a "restoration template" was fabricated, and the condensable resin was filled using a three-sited light-curing incremental technique. All the materials used were applied according to the manufacturers' instructions. The specimens were stored in the 100% humidity for 7 days prior to thermocycling (100 thermal cycles of 5~55$^{\circ}C$ water with a 30-second dwell time) The specimens were immersed in 2% metyleneblue dye for 24 hours, and then embedded in transparent acrylic resin and sectioned mesiodistally with diamond wheel saw. The degree of marginal leakage was scored under stereomicroscope ($\times$20) and the data were analyzed by Kruskal-Wallis test and Wilcoxon signed ranks test. The results were as follows : 1. In the gingival margins of all the group, microleakage of subgroup B was less than subgroup A. 2. In the group 1, 2, 4, there was significant differences between subgroup A and B (p<0.05), but in the group 3, there was not significant different between group 3-A (SureFil) and group 3-B (Dyract flow/SureFil) (p>0.05). 3. In the subgroup A and B, there was significant different between all group except group 4 of subgroup A. From the results above, it was suggested that the cavity lining of flowable resin and flowable compomer in condensable resin restoration decrease microleakage at gingival margin, and does improve their ability to seal the gingival margin of class II preparation.

  • PDF

광조사 방식이 복합레진의 중합과 누출에 미치는 영향 (THE EFFECT OF IRRADIATION MODES ON POLYMERIZATION AND MICROLEAKAGE OF COMPOSITE RESIN)

  • 박종진;박정원;박성호;박주명;권태경;김성교
    • Restorative Dentistry and Endodontics
    • /
    • 제27권2호
    • /
    • pp.158-174
    • /
    • 2002
  • Filtek$^{TM}$ Z-250(3M Dental Products, St. Paul., MN. USA) 광중합형 복합레진을 대상으로 다양한 광조사 방식이 중합수축, 중합도 및 미세누출에 미치는 영향을 알아보고자 하였다. VIP$^{TM}$(Bisco Dental Products, Schaumburg, IL, USA)를 이용하여 200, 400 및 600mW/$\textrm{cm}^2$의 일정한 광도로 중합시킨 세 군(V2, V4 및 V6군)과 200mW/$\textrm{cm}^2$의 광도로 3초간 중합시키고 5분간 방치 한 후 다시 600mW/$\textrm{cm}^2$의 광도로 중합시키는 pulse-delay 방식을 이용한 군(VPD군) 그리고 Optilux 501$^{TM}$(Demetron/Kerr, Danbury, CT, USA)을 이용하여 C-mode와 R-mode로 중합시킨 두 군(OC군, OR군) 등 모두 6개의 군으로 나누어 실험하였으며, 복합레진의 중합과 누출을 다음의 네 가지 방법으로 측정하였다. 첫째, V2, V4, V6, OC군은 60초간, OR군은 20초간 그리고 VPD군은 두번째 광조사를 60초간 시행하면서 시간에 따른 선형 중합수축을 Linometer(R&B, Daejeon, Korea)로 측정하였다. 둘째, V2, V4, V6, OC군은 각각 5, 10, 20, 40, 60초간 그리고 OR군과 VPD군은 정해진 조건에 따라 중합시킨 2mm 두께 시편의 바닥면에서 시료를 채취한 후 KBr method로 시편을 제작하고, FTIR spectrometer(IFS 120 HR, Broker, Karlsruhe, Germany)로 미반응 잔류단량체의 양을 계측하여 중합도를 측정하였다. 셋째, 두번째 실험과 같은 조건으로 중합시킨 2mm 두께 시편의 광조사면과 바닥면에서 중합 10분 후 미세경도 측정기(FM7, Future-Tech Co., Tokyo, Japan)로 500g의 하중을 10초간 가하여 Knoop Hardness Number(KHN) 값을 측정하였다. 끝으로, 90개의 발거치 치경부에 제5급 와동을 형성하고 V2군은 60초간, V4군은 40초간, V6군은 30초간 그리고 OC, OR, VPD군은 정해진 조건에 따라 중합시킨 후, methylene blue 용액에 침적시키고 종절단하여 법랑질과 상아질 변연의 미세누출 정도를 측정하였다. 중합수축. 중합도 및 미세경도 측정치는 one-way ANO-VA와 Duncan's multiple range test를, 변연누출 정도는 chi-square test를 이용, 통계처리하여 다음의 결과를 얻었다. . 중합수축의 정도는 VIP$^{TM}$(Bisco) 사용군에서 전체 조사광도가 높을수록 큰 경향을 보여 600mW/$\textrm{cm}^2$군에서 가장 크게 나타났고, 그 다음으로 Pulse-delay군, 400mW/$\textrm{cm}^2$군, 200 mW/$\textrm{cm}^2$군 순이었고, Optilux 501$^{TM}$(Demetron/Kerr) 사용군에서는 Continuous 방식이 Ramp 방식 보다 크게 나타났다. . 중합도와 미세경도 값은 공히, 전체 조사광도가 높을수록 높게 나타났으며 , 최종 중합도는 44.77~54.98%의 범위를, 미세경도 값은 34.10~56.30의 범위를 보였다. . 미세누출은 전반적으로 상아질 변연이 법랑질 변연에 비해 많았고, VIP$^{TM}$(Bisco) 사용 군에서는 광도가 높을수록 상아질 변연에서 미세누출이 증가하는 양상을 보였으며, 법랑질 변연에서는 Optilux 501$^{TM}$(Demetron/Kerr)의 Continuous 방식이, 상아질 변연에서는 Ramp 방식이 가장 적은 미세누출을 보였다.

3종 광중합개시제를 함유한 실험용 복합레진의 미세누출도 (MICROLEAKAGE OF THE EXPERIMENTAL COMPOSITE RESIN WITH THREE COMPONENT PHOTOINITIATOR SYSTEMS)

  • 김지훈;신동훈
    • Restorative Dentistry and Endodontics
    • /
    • 제34권4호
    • /
    • pp.333-339
    • /
    • 2009
  • 현행 복합레진에서 가장 많이 사용되고 있는 광중합개시제의 일종인 camphoroquinone은 중합 효과가 적고 황색을 띠기 때문에 다른 개시제에 대한 연구가 이루어져 왔다. 이에 본 연구에서는 새로운 개시제인 OPPI (p-octyloxy-phenyl-phenyl iodonium hexafluoroantimonate)를 기존의 camphoroquinone, amine과 다양한 비율로 혼합한 다음, barium glass를 첨가한 실험용 복합레진을 제조하여 각 수복재의 미세누출도를 비교, 평가하였다. 총 4종의 단량체를 제조하였으며 camphoroquinone, OPPI, amine의 조성 중량비는 다음과 같다: A군 - 0.5%, 0%, 1% / B군 - 2%, 0.2%, 2% / C군 - 0.2%, 1%, 0.2% / D군 - 1%, 1%, 2%. 이후 평균 입자 크기 1 ${\mu}m$의 3.2% silane 처리된 barium glass를 중량비 78%로 섞어 복합레진을 제조하였다. 총 55개의 소구치에 치경부를 중심으로 원형 와동을 (직경; 근원심 폭경의 2/3, 깊이; 1.5 mm) 형성한 다음, 자가부식형 접착시스템인 Hybrid Bond로 처리하고 4종의 복합레진으로 수복하였다. 연마 후 치아를 섭씨 5도와 55도에서 각기 30초씩 담궈 500회의 열순환 처리하였으며 전기화학적 방법으로 전기 전도성을 2회 (열순환 처리 후, 1주 간격으로 식염수를 교환하며 3개월 보관 후) 측정, 비교하였다. 미세누출도는 시간 경과에 따라 커지는 양상을 보였으며, 열순환 처리 직후 4종 복합레진 사이에 차이를 보이지 않았지만, 3개월 보관 후에는 D군이 가장 적었으며 C군이 가장 큰 미세누출을 보였다. 열순환 자극 직후 차이를 보이지 않았지만, 3개월 보관 후 측정치로 미루어 볼 때, OPPI와 전반적인 중합시스템이 고농도로 함유된 복합레진(D군)과 CQ와 아민만을 사용한 전통적인 복합레진(A군)이 중합개시시스템을 저농도로 함유한 복합레진(C군)에 비해 우수한 밀폐효과를 보였다. 이는 시간의 흐름에 따라 접착계면의 퇴화가 일어났거나 일부 성분이 용해가 되어 나온 것으로 보이며 앞으로 이에 대한 더 많은 연구가 필요할 것으로 사료된다.

미래모빌리티를 위한 차세대 경량구조복합재료 검토: 자기강화복합재료의 적용 가능성 (Next Generation Lightweight Structural Composite Materials for Future Mobility Review: Applicability of Self-Reinforced Composites)

  • 김미나;장지운;이혜성;오명준;김성륜
    • Composites Research
    • /
    • 제36권1호
    • /
    • pp.1-15
    • /
    • 2023
  • 미래모빌리티의 발전 기대에 따라 에너지 소비 절감에 대한 수요가 증가하고 있다. 경량구조용소재는 온실가스 배출 감소 및 에너지 효율 향상을 위한 방안으로 알려져 있다. 특히, 섬유강화복합재료(FRP, fiber reinforced polymer composite)는 뛰어난 기계적 특성 및 낮은 무게로 인해 기존 합금을 대체할 수 있는 소재로 주목받는다. 본 논문에서는, 탄소섬유강화복합재료(CFRP, carbon FRP) 및 자기강화복합재료(SRC, self-reinforced composite)의 산업 적용 및 연구 동향을 강화재, 고분자 매트릭스 및 공정에 기반하여 검토하였다. 항공분야에서 주로 활용되는 에폭시 수지 기반 오토클레이브 공법의 높은 공정단가 및 긴 제조시간을 극복하기 위하여, 속경화성 에폭시 수지를 이용한 고압수지이송성형 공정으로 CFRP가 적용된 전기자동차의 양산을 보고하였다. 또한, 탄소섬유복합재료의 재활용 이슈를 해결하기 위한 열가소성 수지 기반 CFRP 및 계면 향상 방안들이 재료 및 공정 측면에서 검토되었다. FRP의 우수한 기계적 특성을 유도하는 주요한 요인으로 알려진 완벽한 매트릭스-강화재 계면을 형성하기 위하여, 고분자 섬유에 동일한 매트릭스를 함침시킨 SRC에 대한 연구들이 보고되고 있다. 다양한 열가소성 고분자에 기초한 SRC의 물리적 및 기계적 특성들을 고분자 배향 및 복합재료 구조 측면에서 검토하였다. 또한, 고연 신 폴리프로필렌 섬유 기반 SRC의 공정창 확장을 위한 공중합체 매트릭스 전략이 논의되었다. 경량구조용소재의 CFRP 및 SRC 적용은 미래모빌리티의 에너지 효율 향상에 대한 잠재적인 선택을 제공할 수 있다.

레진시멘트의 보관 조건이 치열교정용 브라켓의 전단접착강도에 미치는 영향 (Effect of storage condition of resin cement on shear bond strength of the orthodontic bracket)

  • 이슬기;김진우;박세희;이윤;김응현;조경모
    • 구강회복응용과학지
    • /
    • 제38권4호
    • /
    • pp.189-195
    • /
    • 2022
  • 목적: 본 연구의 목적은 치열교정용 레진시멘트의 보관 조건이 치열교정용 브라켓의 접착강도에 미치는 영향을 보고자 함이다. 연구 재료 및 방법: 소의 하악 절치 순면 법랑질에 37% 인산으로 산 부식 후 치열교정용 레진시멘트인 Ortho Connect와 Orthomite를 3개월간 4℃ 냉장 보관 후 즉시 적용, 3개월간 4℃ 냉장 보관 후 24시간 동안 실온 보관하고 적용, 3개월간 24℃ 실온 보관 후 적용하는 세 조건에 따라 각 조건별로 15개의 하악 절치용 치열교정용 금속브라켓을 접착하고 광중합 한 뒤 24시간 후에 만능재료시험기로 전단접착강도를 측정하고 접착 실패 양상을 관찰하였다. 측정한 전단접착강도를 95% 유의수준에서 레진시멘트와 보관 조건에 대해 이원배치분산분석을, 레진시멘트에 보관 조건이 미치는 영향에 대해 일원배치분산분석을 했다. 결과: Ortho Connect는 냉장 보관 후 즉시 사용했을 때 가장 높은 전단접착강도를 보였으며 다른 조건 사이에는 차이가 없었다. Orthomite는 냉장 보관 후 즉시 사용했을 때 가장 낮은 전단접착강도를, 3개월 실온 보관했을 때 가장 높은 전단접착강도를 나타냈으며 이 두 조건 사이에만 유의한 차이가 있었다. 결론: Ortho Connect는 냉장 보관 후 즉시 사용해도 적절한 접착이 가능하지만, Orthomite는 냉장 보관을 한다면 충분한 실온 보관을 하는 것이 접착에 유리할 것으로 사료된다.