• 제목/요약/키워드: Light curing time

검색결과 148건 처리시간 0.307초

A COMPARATIVE STUDY ON THE ANTICARIOGENECITY OF ENAMEL SURFACE ADJACENT TO GLASS IONOMER AND RESIN RESTORATION POLYMERIZED BY VISIBLE LIGHT AND ARGON LASER (가시광선과 아르곤 레이저에 의해 중합된 글라스 아이오노머와 레진 수복물 주변 법랑질의 항우식 효과에 관한 비교 연구)

  • Yoo, Byung-Kyu;Kim, Jong-Soo;Kim, Yong-Kee
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • 제25권1호
    • /
    • pp.62-75
    • /
    • 1998
  • The main purpose of this study was to compare the anticariogenecity of glass ionomer restorative material polymerized by argon laser versus visible light, The results from the present study can be summarized as follows; 1. Under the polarized light microscope, the specimens of laser-cured group showed the shallower lesion body than that of visible-light cured group, both in the stage of lesion initiation and progression. 2. Glass ionomer material cured by visible light showed shallower body of lesion than that of composite resin cured by argon laser at the stage of lesion progression(p<0.05). It was suggested fluoride released from the glass ionomer might have the additive anticariogenic effect. 3. Statistical difference between groups on depth of lesion body was evident after lesion progression (p<0.05). It was suggested that anticariogenic effect by argon laser was more effective at the stage of lesion progression than the lesion initiation. 4. The increment of lesion body during progression was highest in group IV (p<0.05). 5. Based upon the above-mentioned results of this study, it can be concluded that the advantage of anticariogenic effect and short curing time of argon laser in glass ionomer polymerization should be considered in children and adolescents whose caries activity is relatively higher.

  • PDF

The influence of nanofillers on the properties of ethanol-solvated and non-solvated dental adhesives

  • da Cruz, Leonardo Bairrada Tavares;Oliveira, Marcelo Tavares;Saraceni, Cintia Helena Coury;Lima, Adriano Fonseca
    • Restorative Dentistry and Endodontics
    • /
    • 제44권3호
    • /
    • pp.28.1-28.10
    • /
    • 2019
  • Objectives: The aim of this study was to evaluate the influence of different concentrations of nanofillers on the chemical and physical properties of ethanol-solvated and non-solvated dental adhesives. Materials and Methods: Eight experimental adhesives were prepared with different nanofiller concentrations (0, 1, 2, and 4 wt%) and 2 solvent concentrations (0% and 10% ethanol). Several properties of the experimental adhesives were evaluated, such as water sorption and solubility (n = 5, 20 seconds light activation), real-time degree of conversion (DC; n = 3, 20 and 40 seconds light activation), and stability of cohesive strength at 6 months (CS; n = 20, 20 seconds light activation) using the microtensile test. A light-emitting diode (Bluephase 20i, Ivoclar Vivadent) with an average light emittance of $1,200mW/cm^2$ was used. Results: The presence of solvent reduced the DC after 20 seconds of curing, but increased the final DC, water sorption, and solubility of the adhesives. Storage in water reduced the strength of the adhesives. The addition of 1 wt% and 2 wt% nanofillers increased the polymerization rate of the adhesives. Conclusions: The presence of nanofillers and ethanol improved the final DC, although the DC of the solvated adhesives at 20 seconds was lower than that of the non-solvated adhesives. The presence of ethanol reduced the strength of the adhesives and increased their water sorption and solubility. However, nanofillers did not affect the water sorption and strength of the tested adhesives.

HARDNESS OF COMPOSITE RESIN CURED BY HIGH INTENSITY HALOGEN LIGHT (고강도 할로겐광으로 중합한 복합레진 수복재의 경도)

  • Park, Jong-Seok;Lee, Kwang-Hee;Kim, Dae-Eup;Kim, Seong-Hyeong;Ahn, Ho-Young
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • 제28권3호
    • /
    • pp.471-479
    • /
    • 2001
  • The purpose of this study was to compare the effect of the high intensity halogen light $(850\sim1000mW/cm^2)$ with that of the conventional halogen light $(400mW/cm^2)$ on the hardness of composite resin. Three resin composites (Z-100, 3M, U.S.A. : Tetric Ceram, Vivadent, Liechtenstein; SureFil, Dentsply, U.S.A.) were filed in the stainless steel moulds which were 4mm in diameter and 2, 3, 4, and 5mm in depth, respectively. They were cured under the four different modes : (1) conventional mode, 40 seconds at $400mW/cm^2$; (2) 'ramp' mode, 10 seconds at 100 to $1000mW/cm^2$ plus 10 seconds at $1000mW/cm^2$; (3) 'boost' mode, 10 seconds at $1000mW/cm^2$; and (4) 'standard' mode, 20 seconds at $850mW/cm^2$. The surface hardnesses of the top and the bottom of the resin samples were measured with a microhardness tester (MXT70, Matsuzawa, Japan). The top surface hardness was not significantly different among the curing modes. The bottom surface hardness was generally the highest in the conventional mode and the lowest in the high intensity boost mode. There was no significant difference in the bottom surface hardness between the conventional mode and the high intensity standard mode in 2mm depth. The results suggest that the curing time of the high intensity halogen light $(850mW/cm^2)$ should be at least 20 seconds to produce the equal level of the bottom surface hardness of 2mm resin composite as compared to the hardness produced by the conventional halogen light $(400mW/cm^2)$.

  • PDF

Curing behavior of Photo-Curable Materials by Photo-Shrinkage Test (광원 경화형 소재의 수축률평가를 통한 광경화 거동 평가)

  • Park, Ji-Won;Bae, Kyung-Yul;Kim, Pan-Seok;Lim, Dong-Hyuk;Kim, Hyun-Joong;Cho, Jin-Ku;Kim, Baek-Jin;Lee, Sang-Hyeup
    • Journal of Adhesion and Interface
    • /
    • 제11권2호
    • /
    • pp.57-62
    • /
    • 2010
  • Photo-curable material can be crosslinked among molecules by light source such as UV and visible light materials. Material properties are controlled by crosslink reaction. Shrinkage is occured during the curing reaction of material structure. Phenomenon of shrinkage stress occurs inside the product and reduce the stability of the product causes problems. Heat shrink the evaluation of the phenomenon has been formalized. But the evaluation of photo shrink is not enough. In this experiment, real-time contract with shrinkage tester phenomena and analysis degree of shrinkage of the material differences. According to the research, experimental results and theoretical analysis of the results were big differences. Shrinkage, especially for a number of different functional groups that were very different theory. These differences are occurred by the molecular structure different and not enough reaction.

Study on the Formation of Residual Layer Thickness by Changing Magnitude and Period of UV Imprinting Pressure (UV임프린트 공정에서 임프린팅 가압력 및 가압시간에 따른 레진 잔막 두께형성에 대한 실험연구)

  • Shin, Dong-Hyuk;Jang, Si-Youl
    • Tribology and Lubricants
    • /
    • 제26권5호
    • /
    • pp.297-302
    • /
    • 2010
  • This study is focused on the resin layer formation of UV imprinting process by changing imprinting pressure and period. The mold shape is made for the process of window open over the pattern transfer area and the imprinting period is assigned as the time just before the UV light curing. The residual layer is measured by changing the imprinting period and pressure magnitude, and the measured data of residual layer provides useful information for the design of the process conditions of imprinting processes.

Effect of Curing Sheet Conbined with Bubble Sheet and Heat generating Materias under Light Source on Surface Temperature of Cement Mortar (광발열소재와 버블시트를 조합한 양생시트가 모르타르의 표면온도 이력에 미치는 영향)

  • Kim, Su-Hoo;Hu, Win-Yao;Beak, Sung-Jin;Han, Jun-Hui;Kim, Jong;Han, Min-Cheol
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 한국건축시공학회 2022년도 봄 학술논문 발표대회
    • /
    • pp.160-161
    • /
    • 2022
  • This study is to investigate the temperature history over time of the cement mortar to confirm the bubble sheet insulation effect using the heat generat sheet. As a result of the experiment, it was confirmed that the heating effect was 6℃ higher on average than other types of sheets when the heating sheet is attached on the bottom of the double layered bubble sheet. For future research, it is planned to verify the heating performance by using the heating sheet under the same environmental conditions as the heating performance will be verified.

  • PDF

A Hardening and Strength Properties of Magnesium Phosphate Mortars for Rapid Repair Materials (급속 보수용 마그네슘 인산염 모르타르의 경화 및 강도특성)

  • Oh, Hongseob;Lee, Inhee
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • 제23권3호
    • /
    • pp.103-110
    • /
    • 2019
  • Damage to the pavement system due to various causes will be required rapid repair work for reopening the vehicle traffic. The magnesium oxide phosphate composite(MPC) has a short curing time and is capable of early compressive strength development, is suitable for rapid repair materials. The aim of this study was to evaluate the hardening and compressive strength characteristics of MPC according to the water-binder (W / B) ratio and magnesium-phosphate(M / P) ratio in order to develop repair materials consisted with light burned magnesia and potassium dihydrogen phosphate. In order to ensure the workability in the field application, the difference of mechanical properties according to standard sand and ordinary sand and performance of retards were evaluated. The mix proportion with W/B ratio was about 35% and the M/P ratio was about 1.0 ~ 1.2 has a superior perfomance with strength and hardening condition. Especially, the strength of composite at only 1 day curing with W/B ratio of 0.35 and the M/P ratio of 1.2 was shown the higher than 25.0 MPa. Boric acid as a retarder was found to be suitable for ensuring the working time, and the purity of magnesium oxide was about 90 ~ 95%, which is effective for ensuring curing time and strength.

Anti-Fogging, Photocatalytic and Self-Cleaning Properties of TiO2-Transparent Coating

  • Mavengere, Shielah;Kim, Jung-Sik
    • Korean Journal of Materials Research
    • /
    • 제31권1호
    • /
    • pp.8-15
    • /
    • 2021
  • Transparent, photocatalytic, and self-cleaning TiO2 thin film is developed by TiO2 sol-gel coating on glass and polycarbonate (PC) substrates. Acetyl acetone (AcAc) suppresses the precipitation of TiO2 by forming a yellowish (complex) transparent sol-gel. XPS analysis confirms the presence of Ti2p and O1s in the thin films on glass and PC substrates. The TiO2-sol is prepared by stabilizing titanium (IV) isopropoxide (TTIP) with diethylamine and methyl alcohol. The addition of AcAcsilane coupling solution to the TiO2-sol instantaneously turns to yellowish color owing to the complexing of titanium with AcAc. The AcAc solution substantially improves the photocatalytic property of the TiO2 coating layer in MB solutions. The coated TiO2 film exhibits super hydrophilicity without and with light irradiation. The TiO2 thin film stabilized by adding 8.7 wt% AcAc shows the highest photo-degradation for methylene blue (MB) solution under UV light irradiation. Also, the optimum photocatalytic activity is obtained for the 8.7 wt% AcAc-stabilized TiO2 coating layer calcined at 450 ℃. The thin-films on glass exhibit fast self-cleaning from oleic acid contamination within 45 min of UV-light irradiation. The appropriate curing time at 140 ℃ improves the anti-fogging and thermal stability of the TiO2 film coated on PC substrate. The watermark-free PC substrate is particularly beneficial to combat fogging problems of transparent substrates.

REAL-TIME MEASUREMENT OF DENTINAL TUBULAR FLUID FLOW DURING AND AFTER AMALGAM AND COMPOSITE RESTORATIONS (아말감과 복합레진의 수복 과정과 수복 후 발생하는 상아세관액 흐름의 실시간 측정)

  • Kim, Sun-Young;Cho, Byeong-Hoon;Baek, Seung-Ho;Lim, Bum-Sun;Lee, In-Bog
    • Restorative Dentistry and Endodontics
    • /
    • 제34권6호
    • /
    • pp.467-476
    • /
    • 2009
  • The aim of this study was to measure the dentinal tubular fluid flow (DFF) during and after amalgam and composite restorations. A newly designed fluid flow measurement instrument was made. A third molar cut at 3 mm apical from the CEJ was connected to the flow measuring device under a hydrostatic pressure of 15 $cmH_2O$. Class I cavity was prepared and restored with either amalgam (Copalite varnish and Bestaloy) or composite (Z-250 with ScotchBond MultiPurpose: MP, Single Bond 2: SB, Clearfil SE Bond: CE and Easy Bond: EB as bonding systems). The DFF was measured from the intact tooth state through restoration procedures to 30 minutes after restoration, and re-measured at 3 and 7days after restoration. Inward fluid flow (IF) during cavity preparation was followed by outward flow (OF) after preparation, In amalgam restoration, the OF changed to IF during amalgam filling and slight OF followed after finishing. In composite restoration, application CE and EB showed a continuous OF and air-dry increased rapidly the OF until light-curing, whereas in MP and SB, rinse and dry caused IF and OF, respectively. Application of hydrophobic bonding resin in MP and CE caused a decrease in flow rate or even slight IF. Light-curing of adhesive and composite showed an abrupt IF. There was no statistically significant difference in the reduction of DFF among the materials at 30 min. 3 and 7 days after restoration (p > 0.05).

A Study on the Alternative Method for Weathering Test of Military Coated Fabrics (군용 도포직물의 내후성시험 대체에 대한 연구)

  • Son, Chanyoung
    • Journal of Korean Society for Quality Management
    • /
    • 제44권3호
    • /
    • pp.509-526
    • /
    • 2016
  • Purpose: We would like to find the alternative method for the weathering test on rubber coated fabrics and adhesive-coated fabrics for the military products, KS M 0706 (Sunshine carbon arc) to KS M ISO 4892-2 (Xenon arc). Methods: We measured the tensile strength of adhesive-coated fabrics and adhesive products treated with sunshine carbon arc and xenon arc during 100, 150 and 200 hours, respectively. All of the results were treated with statistical test, ANOVA method. We also validate the surface modifications caused by treatment method and time by using FT-IR ATR and, SEM. Results: In case of the thick adhesive-coated fabrics (app. 1 mm), there was no distinctive difference on tensile strength by treatment method and time. In case of the thin mask hood (app. 0.22 mm) and TENT (app. 0.5 mm), there was distinctive difference on tensile strength. Especially, carbon arc showed a huge lowering properties. We could validate the curing from light and moisture, and the functional group change from cross-linking and oxidation using FT-IR ATR. In case of IBS, there was a surface cracks on SEM images. In case of mask hood, there was no distinctive differences, except for a particle falling from decreased affinity between rubber and particles caused by carbon arc. Conclusion: We concluded that there was no problems for changing xenon arc weathering test with same treatment time on IBS, KM7, K21 and adhesive products. In case of TENT and mask hood, there was a difference in tensile strength in accordance with the change of the treated time and method.