• 제목/요약/키워드: Light curing composite resin

검색결과 186건 처리시간 0.026초

수복용복합레진의 표면처리방법에 따른 표면중합률 및 변색정도의 변화와 그 상관관계에 대한 연구 (THE CHANGE IN SURFACE CONVERSION AND DISCOLORATION IN DENTAL RESTORATIVE COMPOSITE RESIN UNDER DIFFERENT POLISHING METHODS; THE CORRELATION BETWEEN SURFACE CONVERSION AND SURFACE DISCOLORATION)

  • 박성호;노병덕;김모란;안현정
    • Restorative Dentistry and Endodontics
    • /
    • 제25권3호
    • /
    • pp.482-486
    • /
    • 2000
  • The purpose of the present study was first, to evaluate the relationship between composite surface conversion and surface discoloration, second, to know if there was difference in surface discoloration between celluloid-strip-finished composite surface and polished surface. In addition, the discoloration of composite surface was also evaluated with visual inspection or digital camera with high resolution monitor, Z100, Tetric Ceram, Spectrum, and Aelitfil were used. The composite surfaces were celluloid-strip finished (group 1), polished (group 2), celluloid-strip finished under nitrogen gas purging (group 3) or only light cured without finishing or polishing under nitrogen gas purging (group 4). The microhardness of each samples were also measured in each group. The samples of each group were also divided into 4 subgroup whether they were immediately placed in disclosing solution (0.2% Elythrosin, pH 7.0) (subgroup1), 1 day after light curing(subgroup 2), 3day after light curing(subgroup 3) or 7 day after light curing(subgroup 4). The computer controlled spectrophotometer was used to determine CIELAB coordinates ($L^*$, $a^*$, $b^*$). The amounts of color difference were compared. The results were as follows; 1. There was no difference in discoloration between celluloid strip finished composite surface and polished surface. 2. The samples discolored more when they were placed in disclosing solution immediately after polymerization than other groups. 3. When the samples were light cured under nitrogen gas purging and without polishing process, they discolored more than other groups even though they showed higher micro hardness. 4. With visual inspection or digital camera, only a limited information was available in detecting composite surface discoloration.

  • PDF

와동 형태와 충전 방법에 따른 Class V 복합 레진 수복치의 유한요소법적 응력 분석 (FINITE ELEMENT STRESS ANALYSIS OF CLASS V COMPOSITE RESIN RESTORATION SUBJECTED TO CAVITY FORMS AND PLACEMENT METHODS)

  • 손윤희;조병훈;엄정문
    • Restorative Dentistry and Endodontics
    • /
    • 제25권1호
    • /
    • pp.91-108
    • /
    • 2000
  • Most of cervical abrasion and erosion lesions show gingival margin where the cavosurface angle is on cementum or dentin. Composite resin restoration of cervical lesion shrink toward enamel margin due to polymerization contraction. This shrinkage has clinical problem such as microleakage and secondary caries. Several methods to diminish contraction stress of composite resin restoration, such as modifying cavity form and building up restorations in several increments have been attempted. The purpose of this study was to compare polymerization contraction stress of composite resin in Class V cavity subjected to cavity forms and placement methods. In this study, finite element model of 5 types of Class V cavity was developed on computer tomogram of maxillary central incisor. The types are : 1) Box cavity 2) Box cavity with incisal bevel 3) V shape cavity 4) V shape cavity with incisal bevel 5) Saucer shape cavity. The placement methods are 1) Incisal first oblique incremental curing 2) Bulk curing. An FEM based program for light activated polymerization is not available. For simulation of curing dynamics, time dependent transient thermal conduction analysis was conducted on each cavity and each placement method. For simulation of polymerization shrinkage, thermal stress analysis was performed with each cavity and each placement method. The time-temperature dependent volume shrinkage rate, elastic modulus, and Poisson's ratio were determined in thermal conduction data. The results were as follows : 1. With all five Class V cavifies, the highest Von Mises stress at the composite-tooth interface occurred at gingival margin. 2. With box cavity, V shape cavity and saucer cavity, Von Mises stress at gingival margin of V shape cavity was lower than the others. And that of box cavity was lower than that of saucer cavity. 3. Preparing bevel at incisal cavosurface margin decreased the rate of stress development in early polymerization stage. 4. Preparing bevel at incisal cavosurface margin of V shape cavity increased the Von Mises stress at gingival margin, but decreased at incisal margin. 5. At incisal margin, stress development by bulk curing method was rapid at early stage. Stress development by first increment of incremental curing method was also rapid but lower than that by bulk curing method, however after second increment curing final stress was the same for two placement methods. 6. At gingival margin, stress development by incremental curing method was suddenly rapid at early stage of second increment curing, but final stress was the same for two placement methods.

  • PDF

Errors in light-emitting diodes positioning when curing bulk fill and incremental composites: impact on properties after aging

  • Abdulrahman A. Balhaddad;Isadora M. Garcia;Haifa Maktabi;Maria Salem Ibrahim;Qoot Alkhubaizi;Howard Strassler;Fabricio M. Collares;Mary Anne S. Melo
    • Restorative Dentistry and Endodontics
    • /
    • 제46권4호
    • /
    • pp.51.1-51.13
    • /
    • 2021
  • Objectives: This study aimed to evaluate the effect of improper positioning single-peak and multi-peak lights on color change, microhardness of bottom and top, and surface topography of bulk fill and incremental composites after artificial aging for 1 year. Materials and Methods: Bulk fill and incremental composites were cured using multi-peak and single-peak light-emitting diode (LED) following 4 clinical conditions: (1) optimal condition (no angulation or tip displacement), (2) tip-displacement (2 mm), (3) slight tip angulation (α = 20°) and (4) moderate tip angulation (α = 35°). After 1-year of water aging, the specimens were analyzed for color changes (ΔE), Vickers hardness, surface topography (Ra, Rt, and Rv), and scanning electron microscopy. Results: For samples cured by single-peak LED, the improper positioning significantly increases the color change compared to the optimal position regardless of the type of composite (p < 0.001). For multi-peak LED, the type of resin composite and the curing condition displayed a significant effect on ΔE (p < 0.001). For both LEDs, the Vickers hardness and bottom/top ratio of Vickers hardness were affected by the type of composite and the curing condition (p < 0.01). Conclusions: The bulk fill composite presented greater resistance to wear, higher color stability, and better microhardness than the incremental composite when subjected to improper curing. The multi-peak LED improves curing under improper conditions compared to single-peak LED. Prevention of errors when curing composites requires the attention of all personnel involved in the patient's care once the clinical relevance of the appropriate polymerization reflects on reliable long-term outcomes.

가시광선과 아르곤 레이저로 복합레진 중합시 미세누출에 관한 비교 연구 (MICROLEAKAGE OF COMPOSITE RESINS POLYMERIZED WITH ARGON LASER AND VISIBLE LIGHT)

  • 장기택;정태련;김종철
    • 대한소아치과학회지
    • /
    • 제23권4호
    • /
    • pp.899-905
    • /
    • 1996
  • For the purpose of evaluation of microleakage of class V resin restoration, 64 extracted bovine teeth were filled with two kinds of light curing composite resins(Z-100, Clearfil) and polymerized with 40 seconds of visible light and with 10 seconds of argon laser. After 1000 thermocycling($5^{\circ}C/55^{\circ}C$), specimens were placed in 1 % methylen blue dye solution for 72 hours in $37^{\circ}C$ water bath. The specimens were sectioned at center of filling body and the degree of dye penetration was observed with a stereomicroscope. The following results were obtained, 1. Differences of the microleakage of resin restorations polymerized with 10 seconds of argon laser and 40 seconds of visible light were statistically insignificant. 2. There was more microleakage in Z-100 than clearfil and there was a statistical significancy (p<0.05).

  • PDF

아르곤 레이저에 의한 복합레진의 중합시 물성 변화에 관한 연구 (A STUDY OF PHYSICAL PROPERTIES OF COMPOSITE RESIN POLYMERIZATION WITH ARGON LASER)

  • 김덕;민병순;최호영;박상진;최기운
    • Restorative Dentistry and Endodontics
    • /
    • 제23권1호
    • /
    • pp.1-19
    • /
    • 1998
  • After polymerizing composite resin with argon laser and visible light, four test, to be concretely, measurement of compressive strength using Instron testing machine, surface microhardness using Rockwell hardness tester, quantitative analysis of residual monomer using HPLC and analysis of degree of conversion using FTIR, were accomplished. Test groups were a sort of specimen with 3mm diameter, 4mm thickness for measuring compressive strength, two sort of specimen with 7mm diameter, 2mm and 3mm thickness for measuring surface microhardness, quantitative analysing of residual monomer after curing and measuring the degree of conversion, each were divided by six groups according to the condition of light exposure. In case of argon laser, in 1.0W and 0.5W output, the exposure time for specimen were 5 sec, 10 sec respectiyely. In case of visible light, the exposure time for specimen were 20 sec, 40 sec respectively. The test were accomplished and following results were obtained. 1. Compressive strength of composite resin was the highest in the group of 1 W output, exposing for 10 sec with argon laser, followed by the group of 0.5W, exposing for 10 sec with argon laser, the group of exposing for 40 sec with visible light. But there were statistically no significant difference between these three groups(p>0.05). 2. Surface microhardness of composite resin wasn't significantly affected by light curing conditions. 3. BIS-GMA within residual monomer was least detected in the group of exposing for 40 sec. TEGDMA was least detected in the group of 1 W output, exposing for 10 sec with argon laseboth 2mm and 3mm thickness specimen. 4. The degree of conversion of all groups in the 2mm thickness specimen were more than 50%, similar to each other but in the group of 1W, exposing 10 sec with argon laser the degree of conversion was highest in the 3mm thickness specimen. 5. Argon laser could make composite resin to has similar properties with 25% lesser exposure time than visible light.

  • PDF

광중합형 복합레진 충전 건강보험 급여화에 대한 보호자의 인식과 만족도 (Awareness & satisfaction of caregivers on the health insurance coverage of light-curable composite resin restoration)

  • 유슬아;이수영
    • 한국치위생학회지
    • /
    • 제21권1호
    • /
    • pp.89-98
    • /
    • 2021
  • Objectives: The purpose of this study was to investigate the perception and satisfaction of caregivers and parents after being covered by health insurance for light-curing composite resin fillings, and to contribute to the settlement of the expansion and coverage of health insurance. Methods: A survey was conducted on caregivers who visited two dental institutions in the Gyeonggi-do area, and parents who joined internet cafes (online communities) in the Gyeonggi-do area from June 2 to September 2, 2020. 225 responses were collected eventually, and 212 valid responses were used as analysis data. Results: 67.0% of the study subjects were aware of the permanent teeth resin fillings being covered by health insurance and the satisfaction was relatively high (91.5%). There was a statistically significant difference in the perception of permanent tooth resin filling benefits according to the child's oral condition (p=0.025) and the parents' own interest in oral health (p=0.039). Conclusions: Based on the results of this study, it is necessary to increase the accessibility to the initial treatment for dental care of children through active promotion of detailed items of permanent teeth resin fillings.

고체 amine 광개시제에 따른 치과용 복합수지의 중합효율 (Photopolymerization efficiency of dental resin composites with solid amine photoinitiators)

  • 선금주
    • 대한치과기공학회지
    • /
    • 제28권1호
    • /
    • pp.43-52
    • /
    • 2006
  • Three t-amines, 4-(dimethylamino)benzoic acid (ABA), 4-(dimethylamino)benzaldehyde (MBA), 4-(dimethylamino)benzophenone (MBP), were investigated as new visible light photoinitiators for a dental resin composite of UDMA in order to improve photopolymerization effect. Three t-amines mixed with three photosensiizers, CQ, PD and DA, respectively. And the photopolymerization effect of photoinitiators were compared with that of 4-(dimethylamino)ethyl methacrylate (AEM), the most widely used photoinitiator. The photopolymerization efficiency of UDMA containing the photoinitiator increased with irradiation time. The increase was in the order: MBP

  • PDF

A COMPARATIVE STUDY BETWEEN DEGREE OF CONVERSION AND FLEXURAL STRENGTH OF COMPOSITE RESINS

  • Lee Seong-Hee;Pae Ahran;Kim Sung-Hun
    • 대한치과보철학회지
    • /
    • 제44권3호
    • /
    • pp.333-342
    • /
    • 2006
  • Statement of problem. Although many studies have been carried out to investigate the correlation between the degree of conversion and the flexural strength of composite resins, there is minimal information in the literature attempting to compare degree of conversion, flexural strength and their correlation between restorative composite resins and flowable composite resins. Purpose. The purposes of this study were to measure the degree of conversion and flexural strength of composite resins with different rheological behavior and to correlate the two properties. Materials and methods. Four restorative (Vit-1-escence, Z-250, Tetric ceram, Esthet-X) and four flowable (Aeliteflo, Admiraflow, Permaflo, Revolution) light-curing composite resins were investigated. The degree of conversion(DC) was analyzed with Fourier transfer infra-red spectroscopy(FTIR) spectrum by a potassium bromide(KBr) pellet transmission method. The spectrum of the unpolymerized specimen had been measured before the specimen was irradiated for 60s with a visible light curing unit. The Poiymerized specimen was scanned for its in spectrum. The flexural strength(FS) was measured with 3-point bending test according to ISO 4049 after storage in water at $37^{\circ}C$ for 24 hours. The data were statistically analyzed by an independent sample t-test and one-way ANOVA at the significance level of 0.05. The dependence of flexural strength on the degree of conversion was also analyzed by regression analysis. Results. Mean DC and FS values ranged from 43% to 61% and from 84.7MPa to 156.7MPa respectively. DC values of the flowable composite resins were significantly higher than those of restorative composite resins (P < 0.05). The FS values of restorative composite resins were greater than those of flowable composite resins. No statistically significant correlation was observed between the DC and the FS tested in any of the composites. The dependence of FS on DC in restorative or flowable composite resins was not significant. Conclusion. It can be concluded that radical polymerization of the organic matrix is not a major factor in determining flexural strength of the commercially available composite resins.

광원의 종류에 따른 복합레진의 중합거동 및 중합률에 관한 연구 (THE POLYMERIZATION RATE AND THE DEGREE OF CONVERSION OF COMPOSITE RESINS BY DIFFERENT LIGHT SOURCES)

  • 류주희;이인복;유현미;김미자;석창인;권혁춘
    • Restorative Dentistry and Endodontics
    • /
    • 제29권4호
    • /
    • pp.386-398
    • /
    • 2004
  • Objectives: The purpose of this study was to observe the reaction kinetics and the degree of polymerization of composite resins when cured by different light sources and to evaluate the effectiveness of the blue Light Emitting Diode Light Curing Units (LED LCUs) compared with conventional halogen LCUs. Materials and Methods: First, thermal analysis was performed by a differential scanning calorimeter (DSC). The LED LCU (Elipar Freelight, $320{\;}mW/\textrm{cm}^2$) and the conventional halogen LCU (XL3000, $400{\;}mV/\textrm{cm}^2$) were used in this study for curing three composite resins (SureFil, Z-250 and AEliteFLO). Second. the degree of conversion was obtained in the composite resins cured according to the above curing mode with a FTIR. Third, the measurements of depth of cure were carried out in accordance with ISO 4049 standards. Statistical analysis was performed by two-way ANOVA test at 95% levels of confidence and Duncan's procedure for multiple comparisons. Results: The heat of cure was not statistically different among the LCUs (p > 0.05). The composites cured by the LED (Exp) LCUs were statistically more slowly polymerized than by the halogen LCU and the LED (Std) LCU (p < 0.05). The composite resin groups cured by the LED (Exp) LCUs had significantly greater degree of conversion value than by the halogen LCU and the LED (Std) LCU (p =0.0002). The composite resin groups cured by the LED (Std) LCUs showed significantly greater depth of cure value than by the halogen LCU and the LED (Exp) LCU (p < 0.05).

수종의 이장재가 복합레진의 중합수축에 미치는 영향 (EFFECT OF VARIOUS LINERS ON THE POLYMERIZATION SHRINKAGE OF COMPOSITE RESIN)

  • 최지원;이상호;이난영
    • 대한소아치과학회지
    • /
    • 제33권4호
    • /
    • pp.606-614
    • /
    • 2006
  • 이 연구의 목적은 이장재의 종류에 따른 광중합형 복합레진 충전 후 중합수축을 비교함으로써 중합수축 감소를 보이는 좀 더 우수한 재료의 조합을 모색하고자 시행되었다. 이장재로는 유동형 레진, 컴포머, 광중합 글래스아이오노머를 사용하였고 수축응력을 측정하기 위해 스트레인 게이지를 사용하였다. 표본은 광원의 종류, 이장재의 종류에 따라 8개의 군으로 나눠졌다. 스트레인 게이지를 아크릴릭 링에 부착하고 strainmeter에 연결한 후 각 군에 따라 이장재 적용 후 광중합 하고 이장재 중합 후 750초간 수축응력을 측정하였다. 결과는 Repeated measures ANOVA와 Tukey test를 이용해 통계학적으로 분석하였다. 이상의 실험을 통해 얻은 결과는 다음과 같다. 1. 이장재를 사용하지 않은 군보다 이장재를 사용한 군의 중합수축이 적었으나 Ionosit을 사용한 군에서는 유의한 차이는 없었다(p>0.05). 2, Tetric flow 또는 Vitrebond를 이장재로 사용하는 것이 Ionosit을 사용하는 것보다 중합 수축이 적었다(p<0.05). 3. Tetric flow 이장재를 한 군은 광원에 따른 수축력의 차이가 적었고 Vitrebond와 Ionosit 이장재를 한 군은 할로겐 광원보다 LED 광원에서 수축응력이 컸으나 유의한 차이는 없었다(p>0.05).

  • PDF