• Title/Summary/Keyword: Light Sensitivity

Search Result 614, Processing Time 0.026 seconds

Characteristics of the photoinduced anisotropy(PA) in Ag/AsGeSeS multilayer thin films (Ag/AsGeSeS 다층박막의 광유기 이방성(PA) 특성)

  • Park, Jong-Hwa;Na, Sun-Woong;Yeo, Cheol-Ho;Park, Jeong-Il;Lee, Young-Jong;Chung, Hong-Bay
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.11b
    • /
    • pp.362-365
    • /
    • 2001
  • The chalcogenide glasses of thin films have the superior property of photoinduced anisotrophy(PA). In this study, we observed the linear dichroism(D) using the irradiation with polarized He-Ne laser light, in the $Ag/As_{40}Ge_{10}Se_{15}S_{35}$ multi-layer. Mutilayer structures formed by alternating metal(Ag) a chalcogenide$(As_{40}Ge_{10}Se_{15}S_{35})$. Such multilayer structures have a greater sensitivity to illumination am larger dichroism in comparison the conventional double layer structure. Also new phenomena are discovered. These results will be show a capability of new method that suggested more improvement of photoinduced anisotropy property.

  • PDF

Compressive rheology of aggregated particulate suspensions

  • Gladman Brendan;Usher Shane P.;Scales Peter J.
    • Korea-Australia Rheology Journal
    • /
    • v.18 no.4
    • /
    • pp.191-197
    • /
    • 2006
  • The measurement of the compressional rheological parameters for an aggregated particulate suspension is described. The parameters include the compressive yield stress and hindered settling function, describing the extent and rate of dewatering respectively. The variation of these parameters with shear rate and time of shear is also considered in the light of their sensitivity to low shear rates, with particular reference to the case of flocculated particulate suspensions. The latter is seen to be important in the future development of a comprehensive understanding of compressive rheology of aggregated particulate suspensions in industrial applications such as thickening, filtration and centrifugation.

Development of a Biological Reaction and Measurement Control System for Rapid Detection of the Insecticide Imidacloprid Residues (살충제 Imidacloprid 잔류물의 신속한 측정을 위한 생물반응 및 계측제어 시스템 개발)

  • Lim J. K.;Cho H. K.
    • Journal of Biosystems Engineering
    • /
    • v.30 no.2 s.109
    • /
    • pp.114-120
    • /
    • 2005
  • In this study, a biological reaction and measurement control system was developed to rapidly measure the insecticide imidacloprid residues in agricultural products. The biological reaction part of the system was designed to include micro-pumps and valves for fluid transport, and a polystyrene covet as a reaction chamber. The measurement control part of the system consisted of a photodiode with a light-emitting diode for optical density measurement, and a control microcomputer to implement assay. Signal output was read as the rate of change in optical density at 645 nm. The sensitivity of the system was 2.2 ng/mL ($IC_50$). The system could execute a measurement cycle in about 19 minutes. Research will be continued to develop an automatic sampler fur imidacloprid residues from agricultural products.

CHARACTERISTICS AND PERFORMANCE OF A FAST CCD CAMERA: DALSTA IM30P

  • SEO YOUNG-MIN;PARK KI-WOONG;CHAE JONGCRUL
    • Journal of The Korean Astronomical Society
    • /
    • v.37 no.4
    • /
    • pp.185-191
    • /
    • 2004
  • We have been developing a solar observing system based on a fast CCD camera 1M30P made by the DALSA company. Here we examine and present the characteristics and performance of the camera. For this we have analyzed a number of images of a flat wall illuminated by a constant light source. As a result we found that in the default operating mode 1) the mean bias level is 49 ADU/pix, 2) the mean dark current is about 8 ADU /s/pix, 3) the readout noise is 1.3 ADU, and 4) the gain is about 42 electrons/ ADU. The CCD detector is found to have a linearity with a deviation smaller than $6\%$, and a uniform sensitivity better than $1\%$. These parameters will be used as basic inputs in the analysis of data to be taken by the camera.

Ultra Violet (UV) Sensor based on Oxide Ceramic Materials (산화물 세라믹 재료 기반 자외선 센서)

  • Yu, Hak Ki
    • Ceramist
    • /
    • v.22 no.1
    • /
    • pp.27-35
    • /
    • 2019
  • Research on ultraviolet (UV) light detection has attracted considerable attention from scientific researchers in related fields. It can be said that it is a very important time to accurately monitor the UV irradiation amount according to the wavelength region in real time. The oxide is very diverse in its kind and has the advantage of being able to efficiently control the band gap through band gap engineering. In addition, it is very stable in response to heat and atmospheric oxygen when UV is absorbed. Also, there is a known method that can effectively manufacture oxide nanoparticles and nanorods through various synthesis methods, and researches for improving the sensitivity of UV sensors have been carried out using this method. In this paper, we introduce the materials that can be used as UV sensors among various wide band oxide materials, and review the results of researches of various UV sensors using nano materials.

The photoinduced birefringence of chalcogenide thin film by the Ag Polarized-Photodoping (Ag 편광-광도핑에 의한 칼코게나이드 박막의 광유기 복굴절)

  • Jang, Sun-Joo;Park, Hwa-Jong;Yeo, Cheol-Ho;Lee, Young-Jong;Chung, Hong-Bay
    • Proceedings of the KIEE Conference
    • /
    • 2000.11c
    • /
    • pp.419-421
    • /
    • 2000
  • In this study, we observed the photoinduced birefringence of Ag polarized-photodoping in chalcogenide thin film and the double-layer of Ag doped chalcogenide thin film using the irradiation with the polarized He-Ne laser light. The photoinduced birefringence of Ag polarized-photodoping results in increasing the sensitivity of linearly anisotropy intensity and birefringence(${\Delta}n$). The Ag polarized-photodoping shows improvement of the photoinduced anisotropy property, in polarized photodoping of the chalcogenide thin film. It will offer lots of information for the photodoping mechanism and analysis of chalcogenide thin film.

  • PDF

Complex Conjugate Resolved Retinal Imaging by One-micrometer Spectral Domain Optical Coherence Tomography Using an Electro-optical Phase Modulator

  • Fabritius, Tapio E.J.;Makita, Shuichi;Yamanari, Masahiro;Myllyla, Risto A.;Yasuno, Yoshiaki
    • Journal of the Optical Society of Korea
    • /
    • v.15 no.2
    • /
    • pp.111-117
    • /
    • 2011
  • Full-range spectral domain optical coherence tomography (SD-OCT) with a 1-${\mu}m$ band light source is shown here. The phase of the reference beam is continuously stepped while the probing beam scans the sample laterally (B-scan). The two dimensional spectral interferogram obtained is processed by a Fourier transform method to obtain a complex spectrum leading to a full-range OCT image. A detailed mathematical explanation of the complex conjugate resolving method utilized is provided. The system's measurement speed was 7.96 kHz, the measured axial resolution was $9.6{\mu}m$ in air and the maximum sensitivity 99.4 dB. To demonstrate the effect of mirror image elimination, In vivo human eye pathology was measured.

LINEAR PROGRAMMING OPTIMIZATION OF NUCLEAR ENERGY STRATEGY WITH SODIUM-COOLED FAST REACTORS

  • Lee, Je-Whan;Jeong, Yong-Hoon;Chang, Yoon-Il;Chang, Soon-Heung
    • Nuclear Engineering and Technology
    • /
    • v.43 no.4
    • /
    • pp.383-390
    • /
    • 2011
  • Nuclear power has become an essential part of electricity generation to meet the continuous growth of electricity demand. A Sodium-cooled Fast Reactor (SFR) was developed to extend uranium resource utilization under a growing nuclear energy scenario while concomitantly providing a nuclear waste management solution. Key questions in this scenario are when to introduce SFRs and how many reactors should be introduced. In this study, a methodology using Linear Programming is employed in order to quantify an optimized growth pattern of a nuclear energy system comprising light water reactors and SFRs. The optimization involves tradeoffs between SFR capital cost premiums and the total system U3O8 price premiums. Optimum nuclear growth patterns for several scenarios are presented, as well as sensitivity analyses of important input parameters.

The Uncertainty Analysis of a Liquid Metal Reactor for Burning Minor Actinides from Light Water Reactors

  • Park, Hangbok
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1998.05a
    • /
    • pp.118-123
    • /
    • 1998
  • The neurotics analysis of a liquid metal reactor fur burning minor actinides has shown that uncertainties in the nuclear data of several key minor actinide isotopes can introduce large uncertainties in the predicted performance of the core. A comprehensive sensitivity and uncertainty analysis was performed on a 1200 MWth actinide burner designed for a low burnup reactivity swing, negative doppler coefficient, and low sodium void worth. Sensitivities were generated using depletion perturbaton methods for the equilibrium cycle of the reactor and covariance data was taken ENDF-B/V and other published sources. The relative uncertainties in the burnup swing, doppler coefficient, and void worth were conservatively estimated to be 180%, 91%, and 46%, respectively.

  • PDF

Replication of label-free biosensor with nano grating structures (나노 그래이팅 구조를 갖는 비표지식 바이오센서 성형에 관한 연구)

  • Cho, E.H.;Kim, B.W.;Choi, S.W.;Kim, K.H.;Sung, G.Y.;Kang, S.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2009.05a
    • /
    • pp.290-293
    • /
    • 2009
  • This paper presents the development of a disposable label-free biosensor for bio molecular interaction analysis. Label-free biosensors have advantages of high performance in sensitivity and short detection time. Among various label-free systems, we introduced biosensor with nano grating structures based on white light source and spectrometer. And to develop high efficiency label-free biosensor, we suggest replicating processes satisfying required specification. We also report a system set-up to evaluate the characteristics of phenomenon shown in this biosensor system.

  • PDF